Installation Instructions H Series

Similar documents
Linear Power Supplies Data Sheet

VP ELECTRONIQUE MASSY - Tel

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals.

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

Linear Power Supplies Data Sheet

60 Watt Medical (MWLT)

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

PFE-S SERIES Single Output AC-DC Power Module UL / EN60950 Low Voltage Directive CSA C22.2 No Features Model naming method

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

INSTALLATION MANUAL ULTRAFLEX POWER SUPPLY. UF2500 Series

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

12-15VDC (12V±5%) 24-28VDC (24V±5%)

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

The APR YE meets UL/CSA and all international safety requirements. It is SELV. Min Typ Max 90

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

500Watts Medical Single Output

Cool. NFF Series. CoolX600 NFF Series. NFF Series; No Fan Featured

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

ECF40 Series. 40 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0.

AC-DC POWER SUPPLY UNIVERSAL INPUT, DESK TOP, WATTS MEDICAL APPLICATIONS MUI310-A Series

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

SPECIFICATIONS: PSAK650

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

275 Watt Medical Ultra low profile

Series AME60-MJZ 60 Watt AC-DC / DC-DC Converter

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

Features. Applications and Benefits TRC ELECTRONICS, INC

Typical Input current at 1.15A 0.65A 60 Watt 24VDC / 2.5A. 1.84A 1.0A 120 Watt 24VDC / 5.0A

Standards VDE: EN60950; UL1950; C-UL: CSA C22.2 No.234; IEC950; VDE0805

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

Snaptec Australia Pty. Ltd.

INSTALLATION MANUAL ULTRAFLEX POWER SUPPLY. UF1500 Series

CompactPCI SYSTEM POWER SUPPLIES. CPCI SERIES 150 to 350 Watts, Ac Input with PFC DPCI SERIES 150 to 350 Watts, 48 Vdc Input FEATURES:

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Safety Standards. Model Number:

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

Switch Mode Power Supply S8VT 120/240/480/960 W Models

Series AMEPR60C-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

GLX40 GLX50 UL EN GLX60 GLX110-B GLX110-C GLX200 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX250-CEF GLX250-CF

Standards VDE: EN60950; UL1950; C-UL: CSA C22.2 No.234; IEC950; VDE0805

Power Supplies GLX40 GLX50 GLX60 GLX110-B GLX110-C GLX120 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX200 GLX250-CEF GLX250-CF

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

Section 4 Ground-Fault Protection Devices

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

Input Voltage Range AC Input. Input Frequency Range. Output Power natural convection. Operating Temperature Range. Model Selection

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

PRODUCT SPECIFICATION File:SSA Model : SSA Rev:A2 Date: Nov. 29, 2010

Laboratory Switch Mode Power Supply Series. Instruction Manual

PSC-AC. PSC AC-series W 1 to 3 Outputs. AC-DC Power supply. Input Voltage ranges. Single output ratings. 2-3 outputs ratings

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

Gelo LED Driver 100W, Single output RGLD100-24

12-15VDC (12V±5%) 24-28VDC (24V±5%)

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

Constant Voltage Mode

Series MPM-815H 150W PFC MEDICAL ATX POWER SUPPLY

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

PRODUCT SPECIFICATION File: EA-A0601HE-12 Model: SSA-0601HE-12 Date: Apr. 17, 2015

Over voltage protection: Output shutdown (V1 only) Weight: 730g

CINT W Triple Output Industrial Series

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

EMH Series. 250 W & 350 W Forced-cooled. Industry Standard 3 x 5 x 1.43 Format. IT & Medical (BF) Approvals. 80 V VAC Operation

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Series Watt DC Power Supplies

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC)

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Voltage Current Front-mounting bracket

Basic Characteristics Data

Series AMEPR30D-AZ up to 2A AC-DC LED driver

PS2328 Integrated Power. System

Universal Power Supplies

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

Switching Power Supply

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

SWT SERIES. Features. Model naming method SWT Applications. Conformity to RoHS Directive. Product Line up. Triple Output 30W - 100W SWT A-273

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

Transcription:

Installation Instructions H Series ** Important Note Before connecting AC power to the H Series, please verify that the power transformer is correctly terminated as detailed section 6. Failure to do so could damage the power supply. Installation 1) Power Supply Terminals To meet safety requirements, the power supply terminals must not be used as the external terminations of any equipment. The wiring of any primary circuitry should be routed in such a way that it does not touch any secondary (output) components. 2) Service Personnel This product must only be installed in a restricted access location, accessible to authorized competent personnel only. Some surfaces of the power supply may be hot, and must not be touched when the product is in operation. 3) Earthing For protective earthing, please ensure a secure connection of the Frame Ground terminal to the ground terminal of the equipment as the protective earth connection. Screws and washers used must be of a suitable material as defined by the relevant agency specifications. 4) Cooling The power supply must be installed where the unit is allowed free air convection. Forced air-cooling will enhance reliability. 5) Remote sensing Some models have remote sensing to compensate for load cable drops. The H Series units come wired for local sense from the factory. Remove the wire jumpers and install remote sense wiring if load regulation is critical. Remote sense wiring to the end load should ideally be twisted together and routed separately from load cables or other noisy wiring. 6) Input connection The AC power is wired directly to the primary of the main power transformer. One or two jumpers will also needed on that transformer. Connect the AC Line & Neutral and jumper(s) as follows:

AC INPUT & JUMPER INFORMATION For use at: 100VAC 120VAC 220VAC 230/240VAC Jumper(s) 1-3, 2-4 1 3, 2-4 2-3 2-3 Apply L & N to: 1-5 1 4 1-5 1-4 7) AC fuse An external fuse (see ratings table) should be installed. Use a 125VAC or higher rated fuse for 100-120VAC operation, and a 250VAC fuse for 220-240VAC operation. Fuse type should be anti-surge. 8) External Overvoltage Protectors (OVP12 module) In general most 5V output H Series power supplies come with internal Over Voltage Protection. If OVP is required on other voltage outputs, then an external OVP module should be fitted as follows: The OVP module is user adjustable from approximately 6.2V to 34V. The maximum current rating of the OVP12 module is 12A peak, 8A continuous. The recommended trigger voltages are Nominal Output Voltage 5V 12V 15V 24V Dual +/-12V Dual +/-15V Suggested Trip Point 6.2 +/-0.4V 14V 17V 27V 27V 33V The above table indicates Lambda s recommended level set point for different output voltages. Where +/- outputs exist with a common terminal, a single OVP module located across the + and terminals will provide functional OVP for both individual outputs. The OVP module comes complete with mounting hardware and hookup leads. To connect the OVP to your supply, see your power supply s user s manual for recommended placement or Lambda s website www.lambda.com for the power supply outline drawing. See example below

Solder the black lead to the lead of the supply and the white lead to the + output of the supply. Double check to be sure that the + output of the supply is connected to the + lead of the OVP module and the output is connected to the lead. Rotate the potentiometer (R1) on the OVP module completely clockwise. Without having your load connected to the supply, apply power to the supply and adjust the output voltage on the supply, to the level at which you wish the OVP to trigger. Slowly adjust R1 on the OVP module counterclockwise to the point at which the output of the supply drops suddenly. The OVP trip level is now set. Remove input power to the power supply and back the voltage adjust potentiometer slightly. Re-energize the supply and adjust the output voltage to the nominal voltage rating. The OVP trip level is now set. You may wish to set the OVP potentiometer in place with an electrical grade varnish such as glyptol. Your load is now protected against an overvoltage condition that could destroy the load. Should you experience a situation where the OVP triggers, remove input power! Check for any failures. If the input fuse to the power supply is blown, it is a good indication that there is a failure to the power supply itself. If you find that there is no failure, re-energize the supply. If the supply voltage returns to nominal, the power supply and OVP will be ready for another OVP situation. This is called a nuisance trip. It is not uncommon and does not indicate a failure of the OVP module. Instead, it has done its job and protected your circuit. Nuisance tripping is generally caused by voltage spikes created by the load. If it continually occurs, check your load for noise generating conditions and correct them.

Under all conditions, removal of input power is necessary to reset the OVP. 9) CE Marking The CE Marking on the product is applied to show conformance to the requirements outlined in the European Union s Low Voltage Directive [72/73/EEC] are amended by the CE Marking Directive [93/68/EEC] in that is compliant with EN60950.

H Series Selector Guide Output Voltage (V) Output Current (A) Max Output Power (W) Model Case Size AC Input Fusing 50 o C 60 o C 70 o C 110V 230V Single Output Models 5 3 2.1 1.2 15 HSB 5-3-OVP A 0.5A 0.25A 5 6 4.2 2.4 30 HSC5-6-OVP B 1.5A 0.5A 5 9 6.3 3.6 45 HSN5-9-OVP C 1.5A 0.75A 5 12 8.4 4.8 60 HSD-5-12-OVP I 2.0A 1.0A 12 1.7 1.2 0.7 20.4 HSB-12-1.7 A 0.5A 0.25A 12 3.4 2.4 1.4 40.8 HSC-12-3.4 B 1.5A 0.5A 12 5.1 3.6 2 61.2 HSN-12-5.1 C 1.5A 0.75A 15 1.5 1.1 0.6 22.5 HSB-15-1.5 A 0.5A 0.25A 15 3 2.1 1.2 45 HSC-15-3 B 1.5A 0.5A 15 4.5 3.2 1.8 67.5 HSN-15-4.5 C 1.5A 0.75A 15 6 4.2 2.4 90 HSD-15-6 I 2.0A 1.0A 24 1.2 0.8 0.5 28.8 HSB-24-1.2 A 0.5A 0.25A 24 2.4 1.7 1 57.6 HSC-24-2.4 B 1.5A 0.5A 24 3.6 2.5 1.4 86.4 HSN-24-3.6 C 1.5A 0.75A 24 4.8 3.4 1.9 115.2 HSD-24-4.8 I 2.0A 1.0A 28 1 0.7 0.4 28 HSB-28-1.0 A 0.5A 0.25A 28 2 1.4 0.8 56 HSC-28-2.0 B 1.5A 0.5A 28 3 2.1 1.2 84 HSN-28-3.0 C 1.5A 0.75A 28 4 2.8 1.6 112 HSD-28-4.0 I 2.0A 1.0A Dual Output Models 0.8 1.0/0.8 0.7/0.56 0.4/0.32 24 HDA-12-15 H 1.0A 0.5A -0.8 1.0/0.8 0.7/0.56 0.4/0.32 0.8 1.8/1.5 1.26/1.05 0.72/0.6 40 HDB-12-15 D 1.0A 0.5A -0.8 1.8/1.5 1.26/1.05 0.72/0.6 12* 3.4 2.4 1.4 80 HDC12 I 2.0A 1.0A 12* 3.4 2.4 1.4 15* 3 2.1 1.2 80 HDC15 I 2.0A 1.0A 15* 3 2.1 1.2 Triple Output Models 5* 3 2.1 1.2 40 HTC1 F 1.0A 0.5A 0.8 1.0/0.8 0.7/0.56 0.4/0.32-0.8 1.0/0.8 0.7/0.56 0.4/0.32 5* 6 4.2 2.8 70 HTD1 G 2.0A 1.0A 0.8 1.7/1.5 1.2/1.05 0.68/0.6-0.8 1.7/1.5 1.2/1.05 0.68/0.6 OVP Option N/A 12 OVP12 * Isolated outputs

AC Input 100/120/220/230/240VAC 47-63Hz (Derate 10% for 50Hz operation) EMI FCC Class B, VDE0871 Level B Leakage Current < 50uA Output Voltage Adjustment ± 5% all outputs (except channels 2 & 3 on triple models) Line Regulation ± 0.05 % for 10% line change Load Regulation ± 0.05 % for 50% load change Output Ripple <3mV peak to peak Transient Response 50us for 50% load changes for outputs rated up to 6A 100µS for units rated 6A & over. Temperature Coefficient ± 0.01% per C Operating Temperature Range 0 C ~ +50 C, derate 3%/ C above 50 C up to 70 C Storage Temperature Range -55 C ~ +85 C Operating Humidity 5 ~ 95% RH (non-condensing) Cooling Natural Convection Over Voltage Protection Standard on 5V outputs set at 6.2V ±0.4V Optional OVP circuit available - OVP12 Over Current Protection Foldback with automatic recovery Efficiency (Typical) 5V models 45%, 12/15V models 55%, 24V models 60% Remote Sensing All single output models, HDC12 & HDC15 and channel 1 on triple output models. Warranty 2 years Agency Approvals UL1950, CSA950, EN60950, CE Mark Vibration MIL STD 810C, Method 514 Shock Dielectric Withstand Voltage MIL STD 810C, Method 516 3750VAC Input-Output 1250 VAC Input-Safety ground 500VAC Output-Safety ground