E Serial Controller

Similar documents
ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

GFK-2415A March Type of sensor connection

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

TABLE OF CONTENTS. Communication Functions

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

PRODUCT SPECIFICATION

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

MGate 4101-MB-PBS Series

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

PRODUCT SPECIFICATION

GT- IRDM-9603 Product description Rev. 2 17/06/2014

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

General Operating, Maintenance and Installation Manual

General Specifications. P2-SCM Serial Communications

EQUIPMENT INSTALLATION MANUAL. for the ARINC ALTITUDE ALERTER INTERFACE P/N

P3-SCM. General Specifications

BOARD LEVEL PRODUCTS OEM GPIB<->RS-232 INTERFACE BOARD GPIB

Select a Data Communication Interface

solartron digital readout model no. DR600 DR700 installation manual

ICN Mini Link/External. User s Guide. 1733N Model A Mini Link/EXT (Version 1) 1732N Model A ICN Interface Board (Version 1)

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

Saturn Reader User Manual

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

Enhanced Mini-Chansim Model VCS-232

Manual Industry Interfaces

F1000 User's Manual. (Version: V1.01)

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E

T1K MODBUS Base Controller Specifications

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals.

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

RocketPort Plus Hardware Installation

Table 8 shows the pin configuration and function of a standard computer-to-printer parallel cable. Table 8 Parallel Cable Pin Configuration

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

TTX400-3U-1S Watt, 3U, 1 Slot, 24VDC Input, CompactPCI Power Supply. CompactPCI POWER SUPPLY

RTU560 Remote Terminal Unit Connections and Settings

1 to 16-port RS-232, RS-422/485, and RS-232/422/485 USB-to-serial converters. Features and Benefits. Certifications

ORDERING INFORMATION SEE PAGE 6

RIBBON CABLE CONNECTORS

JUPITER-MM. DC/DC Power Supply PC/104 Module. User Manual V1.3

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

MGate 5105-MB-EIP Series

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION


MEC-COM-M134. User s Manual

Carbon Monoxide Sensor - ModBus

Vorne Industries. 87/415 Rate Monitor Display User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

TN-5308 Quick Installation Guide

Power Supplies GLX40 GLX50 GLX60 GLX110-B GLX110-C GLX120 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX200 GLX250-CEF GLX250-CF

^2 Accessory 8DCE ^1 USER MANUAL. ^3 CE Certified PC Board/Terminal Block. ^4 3Ax xUxx. ^5 October 27, 2003

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Features: Analog to Digital: 12 bit resolution TTL outputs, RS-232 tolerant inputs 4.096V reference (1mV/count) 115K max speed

EQUIPMENT INSTALLATION MANUAL. for the GDC66 FUEL QUANTITY ADAPTER UNIT P/N Rev B

Industrial Power Supplies

RIBBON CABLE CONNECTORS

Miniature Asynchronous 4-Wire High Speed Modems

BOARD LEVEL PRODUCTS GPIB<->RS-422/RS-485 INTERFACE BOARD

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

ZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem

USB-TTL-5 PRODUCT IS A COMBINATION OF PRODUCTS USB AND TTL-232-5P BOTH DATASHEETS ARE INCLUDED IN THIS PDF FILE

Military (Airborne, ground-fix, shipboard), Ruggedized, Telecom, Industrial

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

RTU560 Connections and Settings DIN Rail RTU 560CIG10

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

Koppelmodul (HART--Modem) für SIMATIC PDM Interface (HART modem) for SIMATIC PDM

Junos WebApp Secure 5.0 Hardware Guide

EZ864 UMTS Terminal Telit Cellular GSM Engine

Models: LD9000 Series. Customer Displays. 2 by 20 character display USER MANUAL

Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

SyncLink USB Serial Adapter

Industrial Power Supplies

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

Single Phase Systems-North American PC125/PC420 Series

ZM24x Quick-Connect Industrial Modem. User s Manual

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

MODEL: PS60FS12 / PS60FS15 PS60HS12 / PS60HS15

Instruction Sheet Board Style Low Water Cutoff

CONTROL MICROSYSTEMS and 5601A Input/Output (I/O) Module. Hardware Manual

H-series (Rectifier Module)


BeagleBone Black USB Expansion RS232 Module Cape Coolgear, Inc. Version 1.1 September 2017 Model Number:

Safety Standards. Model Number: Unit Weight:

USB Connectivity. USB Connectivity

ATX-3000 Product Specification Enhance Electronics Co.,LTD

GLX40 GLX50 UL EN GLX60 GLX110-B GLX110-C GLX200 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX250-CEF GLX250-CF

USB-2527 Specifications

EQUIPMENT INSTALLATION MANUAL. for the GDC59 CONVERTER P/N

Moxa TCC-100 Series Hardware Installation Guide

Sender Receiver Sender

PanelView Plus/VersaView CE Terminals and Display Modules

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

Transcription:

SmartSet Technical Reference Manual Addendum for the E281-2310 Controller 1 E281-2310 Serial Controller The following figure shows the mounting dimensions, jumper locations, and connections for the IntelliTouch E281-2310 serial controller: Figure 1. E281-2310 Serial Controller The following table lists the jumper settings for the E281-2310 controller: Reserved Reserved Emulation Mode None E281A-4002 Reserved (From Top) J0 - N J1 - N J2 - N J2 - Y J3 - N E281-2310 Emulation Modes If you are using driver software that does not directly support the SmartSet serial protocol (E281-23xx, E271-22xx), the controller can be set up through jumper J2 for hardware compatibility with the IntelliTouch E281A-4002 controller. DOC # SW000027-B (Preliminary) August 13, 1998

SmartSet Technical Reference Manual Addendum for the E281-2310 Controller 2 Serial Controller Installation This section assumes you are integrating the E281-2310 serial controller board into your system as a component. The following information gives you mounting dimensions, touchscreen connections, power connections and requirements, and data output connections. It is your responsibility to determine how best to mount the controller and data connector in the display or separate enclosure, and provide a power supply. Mounting the Controller and Connecting Chassis Ground The mounting dimensions for the E281-2310 controller are shown in Figure 1, page 1. Remember that the cable headers will increase the space required. The mounting holes fit common 0.156 inch plastic snap-in standoffs. A chassis ground connection is required through one of the plated through mounting holes (PTH) or P4 pin 8 to provide adequate shielding for the touchscreen cable. Conductive mounting hardware can provide a chassis ground connection for the controller. Serial Controller Connections Power Connections The E281-2310 controller operates on a single voltage, positive with respect to ground. See page 10 for power requirements. Connect a power cable harness to P4 on the controller, a 2x5 header with pins on 0.100" centers. Use a ribbon cable with an IDC connector or crimp-to-wire pin receptacles. An acceptable plug can be selected from Molex series 70450, Amp AMPMODU Mod. IV product line, or Berg mini-latch housing with Mini-PV pins. Connect a power supply to the harness and then to AC. 9 7 5 3 1 X 10 8 6 4 2 Figure 2. P4 Power Supply Connector Pin Positions, End View

SmartSet Technical Reference Manual Addendum for the E281-2310 Controller 3 P4 Pins Signal Function 1 +Pwr Supply voltage positive 2 PwrCom Supply voltage negative (tied to pin 4) 3 N/C 4 PwrCom Supply voltage negative (tied to pin 2) 5 LED Remote External LED driver 6 Key 7 N/C 8 Chassis Frame ground connection 9 -Reset Open collector input: open = normal operation; short to PwrCom = hardware reset. 10 N/C CAUTION Observe polarity when connecting the power leads to the power supply. Reversing polarity may damage the controller. Serial Connections The E281-2310 controller operates at standard RS232C levels. The serial port connector, P2, is a 2x5 header with pins on 0.100" centers. It is configured so a ribbon cable and commonly available insulation displacement connectors (IDCs) may be used. 9 7 5 3 1 X 10 8 6 4 2 Figure 3. P2 Serial Connector Pin Positions, End View

SmartSet Technical Reference Manual Addendum for the E281-2310 Controller 4 P2 Pins DB25 DB9 Host Signal 1 8 1 DCD (N/C) 2 6 6 DSR 3 3 2 RXD 4 4 7 RTS 5 2 3 TXD 6 5 8 CTS 7 20 4 DTR 8 22 9 RI (N/C) 9 7 5 GND 10 Key The controller only requires a 2-wire connection, controller Transmit Data (P2 pin 3) and Signal Ground (P2 pin 9). For two-way communications, the controller Receive Data (P2 pin 5) should also be connected to the host Transmit Data pin. Data Set Ready (DSR) and Clear to Send (CTS) may be used by the host to verify controller connections and operation. DSR is asserted when power is applied to the controller and CTS is asserted when the controller's power-on sequence is complete. Data Terminal Ready (DTR) and Request to Send (RTS) can also be connected for full hardware handshaking. Elo driver software typically requires two-way communication (unless ELODEV s -p- flag is used), and all four handshaking lines. If you are installing the controller inside a display, we recommend that you make a cable that connects P2 to a DB9 female connector mounted on the back of the display, or use Elo's serial cable P/N 012138. (Male connectors are used on TouchMonitors with external controllers.) The shell of this connector should be tied to chassis ground. Use an additional cable from the back of the display to your serial port. Elo can provide suitable adapters and cabling. See the IntelliTouch Product Manual for details. Touchscreen Connections A round multi-conductor cable terminated in a 2x6 female connector is attached to the IntelliTouch touchscreen. One of the following cabling options normally applies: If the controller will be located inside the display, the touchscreen cable connects directly to the 2x6 header at P3 on the controller (see Figure 1, page 1).

SmartSet Technical Reference Manual Addendum for the E281-2310 Controller 5 If the controller will be external to the display, the touchscreen cable should be terminated at the back of the display with a DB9 male connector. Use Elo's IC1 adapter cable (P/N 012226). Then connect a cable from the DB9 male connector to the controller using Elo's cable P/N 002863-6-2 with the Elo 002861-2-12 adapter. Unlike the serial cable, the touchscreen cables have a special construction. Use only Elo Touchscreen cables and adapters. 2 4 6 8 10 12 X X 1 3 5 7 9 11 Figure 4. P3 Touchscreen Connector Pin Positions, End View Diagnostic LEDs The E281-2310 controller has one green diagnostic LED. Following power on, the controller performs a short self-test, where the LED stays lit. After the self-test, the LED flashes once per second, indicating normal operation. The self-test results are displayed by most Elo driver software. During normal operation, the LED also indicates controller/host communication is in progress. When the touchscreen is touched, the LED should light continuously, then return to the normal flash rate. If the host does not remove the packet from the controller, the LED will stay lit. The LED will also stay lit without a touch if the touchscreen or cabling is disconnected or not functioning. If the LED flashes about two times per second, a warning error condition is indicated, such as improper communication from the host. Suspect an invalid command sequence from the host. Remote LED Capability The microprocessor pin that drives the status LED is connected to pin 5 of the P4 power supply connector. This signal from the microprocessor may also be used to drive an external indicator such as another LED. To operate an external LED, connect the LED anode to a +5 Vdc power supply and the cathode to pin 5 of the P4 connector. (Nominal current through the LED will be 3 ma the LED will be comparatively dim.)

SmartSet Technical Reference Manual Addendum for the E281-2310 Controller 6 COMMAND REFERENCE The following changes/additions are to Command Descriptions found in the SmartSet Touchscreen Controller Family Technical Reference Manual: page 82 '0' 30h No Warning '9' 39h Reserved 'H' 48h Reserved 'I' 49h Reserved 'J' 4ah Reserved 'L' 4ch Operation failed 'M' 4dh Measurement warning 'N' 4eh Measurement error page 83 page 84 page 87 Untouch factory default value is 2 for the E281-2310 controller. DMask Bit Description 7 Touchscreen Drive test incomplete 5 Touchscreen Drive test failed DMask2 - byte 2 Bit Description 7 Microprocessor logic failure 6 Internal RAM read/write test failure 5 External RAM read/write test failure 4 PROM checksum failure 3 DAC hardware test failure 2-0 Touchscreen drive test results 000 No failure 001 X-axis failure 010 Y-axis failure 011 X receive channel failure 100 Y receive channel failure 101 X transmit channel failure 110 Y transmit channel failure 111 General failure (touchscreen may not be connected)

SmartSet Technical Reference Manual Addendum for the E281-2310 Controller 7 page 88-89 The following combinations of the TouchFlag and Format number are supported: Touch Flag Format 0 0 0 4 0 6 1 0 1 4 1 6 page 90 Set or 0 1 2&3 4 5 6 7 Response: F Type Rep Ofs MinLen MaxLen The Rep word specifies the maximum number of times (1-65535) that a repeating coordinate value is permitted to be measured by the controller. If the number of times that a coordinate repeats in X, Y, and Z exceeds this value, then the controller relearns the touchscreen waveform. This parameter determines the tolerance of contaminants on the touchscreen. The factory default value is 2432, which is about 25 seconds. The Ofs byte specifies the amount (0-255) of surface wave energy absorption that is recognized as a touch. A small value increases touch sensitivity. A large value increases noise rejection. The factory default value is 2. The MinLen byte specifies the minimum width of a touch (0-255). As with the previous argument, a small value increases the sensitivity and a large value increases noise rejection. The factory default is 2. The MaxLen byte specifies the maximum width of a touch (0-255). This parameter controls the rejection of multiple touches and splattered contaminants. The factory default is 22. page 91 page 92

SmartSet Technical Reference Manual Addendum for the E281-2310 Controller 8 page 93 Features byte: Bit 7 is 1 - Z-axis available. page 95 X1 is a bitmap specifying which option jumpers are installed: X1 Bit Position Description 0 J0 installed 1 J1 installed 2 J2 installed 3 J3 installed X2 is a bitmap specifying whether cross-connected jumpers are installed: X2 Bit position Description 0 jumper connects J0 to J1 1 jumper connects J1 to J2 2 jumper connects J2 to J3 page 97 page 98 page 99 Mode1: Bit Description 6 Reserved (0) 7 1 - Z-axis Enable Mode2: All bits reserved (0). page 102 page 104 page 108 page 109 page 110 page 112 Hard Reset Command: If the host cannot monitor -CTS, approximately 5 seconds should be allowed for the reset procedure to take place. Set or query commands are not supported. Touch packets are generated automatically.

SmartSet Technical Reference Manual Addendum for the E281-2310 Controller 9 Status bits: Bit Description 6 Reserved (0) 7 If 1, the Z coordinate is measured, not simulated at the maximum value.

SmartSet Technical Reference Manual Addendum for the E281-2310 Controller 10 E281-2310 SPECIFICATIONS Electrical Supply Voltage and Current +5 Vdc, nominal (+4.75 to +5.25 Vdc). 140 ma, typical at +5 Vdc. Average power dissipation is 0.7 W, typical. Supply must be capable of sourcing 200 ma, minimum, and have a rise time of less than 100 ms. Conformance to this specification is yet to be determined. Total noise and ripple requirement must be less than 100 mv (p-p) for frequencies below 1 MHz, and less than 5 mv (p-p) for frequencies above 1 MHz. Interface EIA 232D (Serial RS-232), DCE configuration. 8 Data Bits, 1 Stop Bit, No Parity, Half Duplex. Hardware handshaking: DTR/DSR, RTS/CTS. Acknowledgments for command set and query. Baud Rate 9600 only. Operating Modes Binary in SmartSet or E281A-4002 protocols, jumper selectable. Initial/Stream/Untouch/Z-axis Enable Modes. Touch Resolution Approximately 4095x4095, size independent, 255 levels of Z (pressure). Conversion Time Approximately 10.4 ms per coordinate report. Reliability MTBF greater than 60,000 hours per MIL-HDBK-217E Notice 1 update part count calculation. Conformance to this specification is yet to be determined.

SmartSet Technical Reference Manual Addendum for the E281-2310 Controller 11 Reliability is enhanced by Elo's standard manufacturing practice of submitting all controllers to a 10-hour burn-in at 50 C with 50% power on/off cycle. Environmental Temperature Operating: 0 C to 65 C. Storage: -25 C to 85 C. Conformance to this specification is yet to be determined. Humidity Operating: Storage: 10% to 90% RH, non-condensing. Same. Conformance to this specification is yet to be determined. Altitude 10,000 feet. Conformance to this specification is yet to be determined. Shock and Vibration National Safe Transit Association Project 1A Test Procedure. Conformance to this specification is yet to be determined. ESD Per IEC 801-2(E): 1991. Conformance to this specification is yet to be determined. Flammability The printed circuit board substrate is rated 94V0. All plastic components also rated 94V0.

SmartSet Technical Reference Manual Addendum for the E281-2310 Controller 12 Physical Characteristics Construction Four-layer surface-mount design with internal ground plane for EMI suppression. Dimensions See Figure 1, page 1. Total height including shield less than 0.75". Mounting Hole Dimensions See Figure 1, page 1. Two mounting holes are plated through-holes (PTH) for chassis ground connection. Connectors and Pin Definitions The connector configuration permits the controller to be placed in-line between the touchscreen and serial I/O attachments. Serial Input/Output Connector 2x5 0.025" post latching header on 0.100" centers. Acceptable mating insulation displacement connectors (IDC): Berg series 71600, 71602, 66900, 66902, Molex series 40312, Amp series 746285 and 746288. When the mating IDC receptacle is cabled to an IDC DB9 connector, the interface assumes a DCE configuration. Touchscreen Connector 2x6 0.025" square post friction lock header on 0.100" centers. Mates with Berg Mini-Latch receptacle on the IntelliTouch touchscreen cable. The withdrawal force exceeds 3.9 lb. Power Connector 2x5 0.025" square post friction lock header on 0.100" centers. Acceptable mating receptacle connectors: Molex series 70450, Amp AMPMODU Mod. IV product line, or Berg mini-latch housing with Mini-PV pins.

SmartSet Technical Reference Manual Addendum for the E281-2310 Controller 13 Agency Approvals Elo TouchSystems controller board model E281-2310 is a UL Recognized Component, CCN NWGQ2, per UL 1950, Safety of Information Technology Equipment Including Electrical Business Equipment. Recognition information is contained in File E162681. Elo TouchSystems controller board model E281-2310 is a UL Recognized Component for use in Canada, CCN NWGQ8, per UL 1950, Safety of Information Technology Equipment Including Electrical Business Equipment Certified for Canada. Recognition information is contained in File E162681. The E281-2310 has been tested to verify compliance with FCC Class B commercial limits. Test results are on file. Conformance to these or to more stringent limits may require special attention to system grounding and shielding, and it may be necessary to apply ferrite suppressor beads to cables.