F port channel trunk from MDS 9148 (NPV) to MDS 9509 (NPIV) Configuration Example

Similar documents
Tech Note on Priority Transmit B2B Credits in MDS Switches

Configuring Cisco Unified FEX Nexus 2348UPQ with Fiber Channel Interfaces

Configuring Interface Buffers

Configuring PortChannels

Configuring FCoE NPV. Information About FCoE NPV. This chapter contains the following sections:

Cisco Nexus 9000 Series NX-OS FC NPV Configuration Guide, Release 9.x

Configuring Fibre Channel Interfaces

Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example

Congestion Avoidance. Finding Feature Information

Cisco MDS 9000 Family NX-OS Licensing Guide, Release 6.x

Large SAN Design Best Practices Using Cisco MDS 9700 and MDS 9500 Multilayer Directors

FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch

Cisco MDS 9000 Series NX-OS Interfaces Configuration Guide

Troubleshooting Zones and Zone Sets

Configuring SAN Port Channel

DCNX5K: Configuring Cisco Nexus 5000 Switches

Configuring IP Storage

MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1)

Troubleshooting N-Port Virtualization

Managing Modules. About Modules. Send documentation comments to CHAPTER

Configuring the Fibre Channel Gateway

Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

MDS 9000 Core with Brocade 3900/12000 Edge Topology

Cisco MDS NX-OS Release 6.2Configuration Limits 2

Configuring a Dual Fabric SAN Environment

Cisco MDS 9000 Family Blade Switch Solutions Guide

This table describes the supervisor module options for switches in the Cisco MDS 9000 Family.

UCS Direct Attached Storage and FC Zoning Configuration Example

Advanced Services Module Commands

FCoE Cookbook for HP Virtual Connect

MDS to MDS Basic Configuration with FCIP

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

Inter-VSAN Routing Configuration

DC Compute SAN. Carlos Lopez CCIE SAN, DC #21063 David Kester CCIE SAN #19555 Ed Mazurek CCIE SNA/IP, SAN #6448

1. Slow port emulation with R_RDY delay of us (1.5 seconds) 2. Port-monitor - slow port emulation with R_RDY delay of us (1.

CCIE Data Center Storage Networking. Fibre Channel Switching Configuration. Nexus 5500UP FC Initialization Allocate interfaces as type FC

Configuring SPAN. Configuring SPAN. SPAN Sources. This chapter includes the following sections: Configuring SPAN, page 1

IBM To Resell Cisco Systems MDS 9000 Multilayer Switch and Director Family of Intelligent Storage Networking Products

Designing SAN Using Cisco MDS 9000 Series Fabric Switches

Designing and Deploying a Cisco Unified Computing System SAN Using Cisco MDS 9000 Family Switches

N-Port Virtualization in the Data Center

Send documentation comments to You must enable FCIP before attempting to configure it on the switch.

Storage Networking Cisco MDS 9148 Beta Testing

Fibre Channel Traffic Issues with MXP MR 10DME C Linecards

On the Cisco Nexus 5548 Switch, Fibre Channel ports and VSAN ports cannot be configured as ingress source ports in a SPAN session.

Configuring Microsoft Windows XP iscsi Host to MDS/IPS 8

Configuring VSANs and Interfaces

Cisco MDS 9000 Family NX-OS High Availability and Redundancy Configuration Guide

IVR Zones and Zonesets

Managing FLOGI, Name Server, FDMI, and RSCN Databases

Configuring Enhanced Virtual Port Channels

UCS Engineering Details for the SAN Administrator

AVANTUS TRAINING PTE LTD

On-Demand Port Activation Licensing

Getting Started. Enabling SSH

Scheduling Maintenance Jobs

VLAN Configuration via CLI on 300/500 Series Managed Switches

Configuring FCoE NPV. FCoE NPV Overview. FCoE NPV Benefits

Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.0(1a)

Configuring Port Channels

Contents. FCoE commands 1

IP Phone 7940/7960 Fails to BootProtocol Application Invalid

Intermixing Best Practices

Cisco Nexus B22HP. Design and Deployment Guide. September, For further information, questions and comments please contact

Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.0(4c)

Cisco Data Center/Storage Certification

"Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary

Monitoring and Alerting in Cisco MDS Fabric

P Commands. Send documentation comments to CHAPTER

UCS-ABC. Cisco Unified Computing System Accelerated Boot Camp. Length: 5 Days. Format: Lecture/Lab. Course Version: 5.0. Product Version: 2.

This guide presents the instructions and other information concerning the lab activities for this course.

Configuring Layer 3 Interfaces

Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide

Cisco SME CLI Commands

Power Systems SAN Multipath Configuration Using NPIV v1.2

Cisco MDS Port 10-Gbps Fibre Channel over Ethernet Module


Configuring sflow. Information About sflow. sflow Agent. This chapter contains the following sections:

Configuring Fabric Congestion Control and QoS

Contents. FCoE commands 0

zseries FICON and FCP Fabrics -

Interoperability Limitations

Flash Devices in the Cisco MDS 9000 Supervisor Module. External CompactFlash in the Cisco MDS 9000 Supervisor Module.

Deploying IP Storage Solutions with the Cisco MDS 9000

Fibre Channel Performance: Congestion, Slow Drain, and Over Utilization, Oh My! Live Webcast February 6, :00 am PT

Configuring IPv4. Finding Feature Information. This chapter contains the following sections:

Cisco MDS NX-OS Release Compatibility Matrix for Storage Service Interface Images

Dell Networking MXL / PowerEdge I/O Aggregator with Cisco Nexus 5000 series NPV mode and Cisco MDS 9100 fabric switch Config Sheets

Cisco Nexus 5600 Series NX-OS SAN Switching Configuration Guide, Release 7.x

vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide

LAN Ports and Port Channels

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024 and 8024F. Dell Networking Solutions Engineering March 2012

Advanced Storage Area Network Design

Configuring Fabric Configuration Server

Understand Source MAC Address Field in Spanning-Tree PDUs on Nexus Series Switches

ITBraindumps. Latest IT Braindumps study guide

Cisco MDS 9000 NX-OS Software Release 5.0(1)

Troubleshooting Cisco Data Center Unified Fabric

Using the Cisco NX-OS Setup Utility

MDS 9020 Switch Interoperability

Transcription:

F port channel trunk from MDS 9148 (NPV) to MDS 9509 (NPIV) Configuration Example Document ID: 117781 Contributed by Edward Mazurek, Cisco TAC Engineer. Sep 05, 2014 Contents Introduction Prerequisites Requirements Components Used Configure MDS 9509 That Runs NX OS Sofware Release 6.2(9) MDS 9148 That Runs NX OS Sofware Release 6.2(9) Network Diagram F port channel trunk from MDS 9148(NPV) to MDS 9509(NPIV) Topology Verify MDS 9509 MDS 9148 Troubleshoot VSAN(s) Remain in Initializing EPP Failure Messages Seen Introduction This document describes how to configure an F port channel trunk from a Multilayer Data Switch (MDS) 9500 that runs with feature N_Port ID Virtualization (NPIV) to an MDS 9148 that runs feature N_Port Virtualization (NPV). F port channel trunks allow for the fabric logins from the NPV switch to be virtualized over the port channel. This provides non disruptive redundancy should individual member links fail. The individual links by default are in rate mode shared, but can be rate mode dedicated as well. Prerequisites Requirements Cisco recommends that you have knowledge of these topics: N_Port Virtualization Fibre Channel Components Used The information in this document is based on these software and hardware versions:

MDS 9509 that runs NX OS Software Release 6.2(9) Slot 2 DS X9148 48 port 1/2/4 Gbps FC Module Slot 4 DS X9124 24 port 1/2/4 Gbps FC Module MDS 9148 that runs NX OS Software Release 6.2(9) This document relies on these features: Feature NPV and NPIV were added in SAN OS Sofware Release 3.3 Feature fport channel trunk was added NX OS Software Release 4.1(3) The information in this document was created from the devices in a specific lab environment. All of the devices used in this document started with a cleared (default) configuration. If your network is live, make sure that you understand the potential impact of any command. Configure Note: Use the Command Lookup Tool (registered customers only) in order to obtain more information on the commands used in this section. Notes: All interfaces should be in the same Virtual Storage Area Network (VSAN). This example uses VSAN 1. It is a best practice to distribute the member interfaces onto different linecards. "" is optional. By default, Trunking F (TF) port interfaces can run in rate mode shared if desired. If the bandwidth on the port group is available, they can be configured with the command. You can enter the show port resources module x command in order to see the port groups and available bandwidth on each. MDS 9509 That Runs NX OS Sofware Release 6.2(9) feature fport channel trunk feature npiv interface port channel 1 channel mode active switchport mode F switchport trunk allowed vsan 1 switchport trunk allowed vsan add 20 interface fc2/2 switchport mode F interface fc4/8 switchport mode F MDS 9148 That Runs NX OS Sofware Release 6.2(9) Notes: All ports on a 9148 are dedicated (full rate mode) so no configuration is necessary on the 9148 in order to

ensure dedicated. In fact, the "" command is added automatically and cannot be changed. "feature fport channel trunk" does not need to be configured on MDS NPV switches. A change to NPV mode erases the current configuration and reboots the switch in NPV mode. feature npv interface port channel 1 channel mode active switchport mode NP switchport trunk allowed vsan 1 switchport trunk allowed vsan add 20 switchport trunk mode on interface fc1/2 switchport mode NP switchport trunk mode on port license acquire interface fc1/14 switchport mode NP switchport trunk mode on port license acquire Network Diagram F port channel trunk from MDS 9148(NPV) to MDS 9509(NPIV) Topology MDS 9509 module information: mds9509# show mod Mod Ports Module Type Model Status

2 48 1/2/4 Gbps FC Module DS X9148 ok 4 24 1/2/4 Gbps FC Module DS X9124 ok 5 0 Supervisor/Fabric 2 DS X9530 SF2 K9 active * 6 0 Supervisor/Fabric 2 DS X9530 SF2 K9 ha standby MDS 9148 module information: mds9148# show mod Mod Ports Module Type Model Status 1 48 1/2/4/8 Gbps FC/Supervisor 3 DS C9148 K9 SUP active * Verify Use this section to confirm that your configuration works properly. The Output Interpreter Tool (registered customers only) supports certain show commands. Use the Output Interpreter Tool in order to view an analysis of show command output. MDS 9509 This command indicates port channel 1 has two operational ports. mds9509# show port channel summary Interface Total Ports Oper Ports First Oper Port port channel 1 2 2 fc4/8 This command shows the port channel and all of the member interfaces. The First Operational Port (FOP) is indicated with an asterisk: mds9509(config if)# show port channel data port channel1 Administrative channel mode is active Operational channel mode is active Last membership update succeeded First operational port is fc4/8 2 ports in total, 2 ports up Ports: fc2/2 [up] fc4/8 [up] * This command shows the port channel 1 interface is in state "trunking" which is the desired state. Note: VSANs 1 and 20 are both up which indicates there are ports in both VSANs that are UP on the 9148. mds9509# show int po1 port channel 1 is trunking Hardware is Fibre Channel Port WWN is 24:01:00:0d:ec:20:ba:00 Admin port mode is F, trunk mode is on Port mode is TF Speed is 8 Gbps 5 minutes input rate 112 bits/sec, 14 bytes/sec, 0 frames/sec

5 minutes output rate 152 bits/sec, 19 bytes/sec, 0 frames/sec 25798 frames input, 1399932 bytes 0 discards, 0 errors 0 CRC, 0 unknown class 0 too long, 0 too short 23082 frames output, 1013152 bytes 0 discards, 0 errors 18 input OLS, 14 LRR, 29 NOS, 0 loop inits 17 output OLS, 0 LRR, 21 NOS, 0 loop inits Member[1] : fc4/2 Member[2] : fc4/8 Interface last changed at Thu Mar 6 06:27:36 2014 This command shows the two member interfaces also in state "trunking". mds9509# show interface fc2/2, fc4/8 fc2/2 is trunking Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN) Port WWN is 20:42:00:0d:ec:20:ba:00 Admin port mode is F, trunk mode is on Port mode is TF Speed is 4 Gbps Rate mode is dedicated Transmit B2B Credit is 32 Receive B2B Credit is 16 Receive data field Size is 2112 Beacon is turned off admin fec state is down oper fec state is down Belongs to port channel1 5 minutes input rate 0 bits/sec,0 bytes/sec, 0 frames/sec 5 minutes output rate 0 bits/sec,0 bytes/sec, 0 frames/sec 31 frames input,4476 bytes 0 invalid CRC/FCS,0 unknown class 0 too long,0 too short 30 frames output,4224 bytes 3 input OLS,3 LRR,7 NOS,0 loop inits 5 output OLS,0 LRR, 4 NOS, 0 loop inits 16 receive B2B credit remaining 32 transmit B2B credit remaining 32 low priority transmit B2B credit remaining Last clearing of "show interface" counters :never fc4/8 is trunking Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN) Port WWN is 20:c8:00:0d:ec:20:ba:00 Admin port mode is F, trunk mode is on Port mode is TF Speed is 4 Gbps Rate mode is dedicated Transmit B2B Credit is 32 Receive B2B Credit is 16 Receive data field Size is 2112 Beacon is turned off admin fec state is down oper fec state is down

Belongs to port channel1 5 minutes input rate 8 bits/sec,1 bytes/sec, 0 frames/sec 5 minutes output rate 8 bits/sec,1 bytes/sec, 0 frames/sec 45855 frames input,1934340 bytes 0 invalid CRC/FCS,0 unknown class 0 too long,0 too short 23018 frames output,1115304 bytes 8 input OLS,5 LRR,8 NOS,0 loop inits 7 output OLS,0 LRR, 6 NOS, 0 loop inits 16 receive B2B credit remaining 32 transmit B2B credit remaining 32 low priority transmit B2B credit remaining Last clearing of "show interface" counters 2w 1d MDS 9148 This command indicates port channel 1 has two operational ports. mds9148# show port channel summary Interface Total Ports Oper Ports First Oper Port port channel 1 2 2 fc1/2 This command shows the port channel 1 interface is in state "trunking" which is the desired state. Note: VSANs 1 and 20 are both up which indicates there are ports in both VSANs that are UP on the 9148. mds9148# show int po1 port channel 1 is trunking Hardware is Fibre Channel Port WWN is 24:01:00:0d:ec:fc:40:c0 Admin port mode is NP, trunk mode is on Port mode is TNP Speed is 8 Gbps 5 minutes input rate 32 bits/sec,4 bytes/sec, 0 frames/sec 5 minutes output rate 32 bits/sec,4 bytes/sec, 0 frames/sec 688 frames input,91096 bytes 0 invalid CRC/FCS,0 unknown class 0 too long,0 too short 661 frames output,89080 bytes 3 discards,0 errors 14 input OLS,0 LRR,0 NOS,0 loop inits 32 output OLS,29 LRR, 14 NOS, 0 loop inits Member[1] : fc1/2 Member[2] : fc1/14 Interface last changed at Thu Mar 6 18:48:57 2014

Troubleshoot This section provides information you can use to troubleshoot your configuration. If the port channel does not come up, review this information: A port can be configured as a member of a static PortChannel only if these configurations are the same in the port and the PortChannel: Speed Mode Rate mode Port VSAN Trunking mode Allowed VSAN list or VF ID list Configure the port not in a port channel and verify it comes up. Refer to Configuring Port Channels for more information. VSAN(s) Remain in Initializing VSANs show as initializing when there are no interfaces FLOGI'd in to that VSAN on the MDS 9148. Once the VSAN is up on the port channel, if the last remaining port in the VSAN on the MDS 9148 goes down the VSAN remains up. EPP Failure Messages Seen Ensure trunk protocol (EPP) is enabled. It should never be turned off: rtp san 34 15 9509(config)# show trunk protocol Trunk Protocol is enabled If trunk protocol is disabled then turn it back on: mds9509(config)# show trunk protocol Trunk Protocol is disabled mds9509(config)# trunk protocol mds9509(config)# mds9509(config)# show trunk protocol Trunk Protocol is enabled Updated: Sep 05, 2014 Document ID: 117781