FEATURES Pressure chamber with clamping platform Sealed outlet for ¼ microphone Pneumatic excitation of small diaphragms

Similar documents
A10 Micro Speaker Clamping A10. Micro Speaker Clamping FEATURES

B-Field Scanner Software

KLIPPEL Analyzer System Price-List

KLIPPEL Analyzer System Price-List

Directivity of Speaker Arrays AN 70

Multiplexer FEATURES. Applicable in R&D and end-ofline. Required for testing of multichannel

Directivity Measurement with Turntables AN54

Spider and Surround Separation AN 2

Instruction Manual. G.R.A.S. 1/2, 1/4, and 1/8 CCP Flush-mount microphone sets. LI May 2015

Importing Polytec data into SCN AN 68

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

The 5.8mm diameter ROM-2235L-HD-R is designed for extreme fidelity in a compact housing with true 20 Hz to 20 khz performance.

Orbis MU 21. Digital Delegate Microphone Unit with Loudspeaker Order #

Model VDL 115 Vacuum drying chambers for flammable solvents

Supplementary instructions. VEGADIS adapter. For connection of an external display and adjustment unit or a slave sensor. Document ID: 45250

SX100A. Features. Typical Applications. Description

System Description. FINO Semiautomatic Stencil Printer Version 1.1 July 11 th Modification protocol Version

PRELIMINARY. CR Series. Ceiling Rack Systems with AmbiTILT Equipment Loading

Noise and vibration tester

SX15GD2. Features. Typical Applications. Description

¼ MEASUREMENT MICROPHONE EMX-7150

SX01DN. Features. Typical Applications. Description

K1B004TLH cam switch - 1 pole A - screw mounting

POSITIONING DEVICES AND ACCESSORIES FOR ANECHOIC CHAMBERS, OATS AND SHIELDED ROOMS

Cable Entry Systems for Potentially Explosive Atmospheres

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176

X=2000 Z=2000 X=2000 Z=1600. E0/E150 in µm L/ L/ L/ L/ L/ L/400. R0 in µm

K1D012ULH cam changeover switch - 2-pole A - screw mounting

Stereo - Amplifier. User s Manual

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

Floormaster DVQA, quarter-cylindrical terminals

CT AUTOMATIC WINDING MACHINE

FEA/BEA interface for SCN AN 55

-42±3dB (0dB=1V/Pa at 1 KHz) 2.0V 2.2KΩ MADE BY CHECKED BY APPROVED BY. Revision level Description of changes Changed date

Bulletin 871D Cylinder Position Inductive Style

Model VD 23 Vacuum drying chambers for non-flammable solvents

(step index fiber) Brass sheathing: -30 C +200 C. Stainless steel sheathing:

3SM102EZT13C MEMS Microphone

Measurement of Static Insertion Loss of Flexible Ducting

LSP 500 PRO. Wireless Integrated Professional Audio System FEATURES ARCHITECT S SPECIFICATION

Immunity: EN capacity 75 µl Capillaries. 1,5 x 75 mm. Rotor and Lid as evaluation disc incl. Cat.-No. capillaries per rotor

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

Dual Fiber SWIR Laser Doppler Vibrometer

LACOSTE & ROMBERG AIR-SEA GRAVITY METER VIBRATION TESTS

smartsms-net Networked Smart Sound Masking System Flexibility, simplicity and unrivaled sound masking quality

Instruction Manual. GRAS 45CA Headphone/Hearing-protector Test Fixture. 45CA-1 to 45CA-10

analysette 3 particle size analysis quality control sieving for your lab Vibratory Sieve Shaker Microprocessor controlled

Pl atinum Series Condenser Microphone OSM

DATA SHEET. L1210/65/68 Tray loaders incorporating VAM1202/12 mechanism for 2x Speed. Philips Optical Storage. Philips Components

K1F006ALH cam switch - 6-pole A - screw mounting

More Precision. optocontrol // Optical precision micrometers

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

ZB4BV013 white pilot light head Ø22 plain lens for integral LED

Modular system for ACO Bath gullies Easyflow

Measurement microphone. MI series

Inductive Cylinder Position Sensors

CypLite Fiber Laser Cutting Head User Manual

Homag Single-Sided Softforming Machine, Model KLO 79/1/E12/S3

Furnace Camera System Operator s Manual. Version

RACON short-travel keyswitches

POSITION MONITOR USERS MANUAL POM-M2 / POM-M3. Content

Lighting Controls and Connectivity DALI sensors. MSensor G3 SFI 30 PIR 10DPI WH Multi-sensor

The VoiceArrest System

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS HV-STYLVENT. Wall or window extract fans. Elegant design harmonising with any environment

Tykoflex cold method. A safe, simple and proven cold method TYKOFLEX COLD METHOD

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS. Wall or window extract fans HV-STYLVENT. Elegant design harmonising with any environment

MIGRATION OF CENTER OF GRAVITY ON THE 40 INCH DIAMETER TANK WITH STIFFENING RINGS

3SM122HZB1VA MEMS Microphone

PNEUMATIC CRIMPER PC 12-8B OPERATING MANUAL

MP54 SOUND for AC track power by

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment)

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

Sit-Stand Monitor Arm

panasonic.net/id/pidsx/global Up to 16 I/O devices can be connected at once using MIL connectors

FOR GENELEC LOUDSPEAKERS

CS-1 Active Full Range Integrated Commercial Audiovisual System

Mark like a Professional. Table marking system NetMarker

Waterproof Electrical Junction Box Kits Technical Data Sheet

BMFL WashBeam W OSRAM Lok-it! HTI 1700/PS lm, m, m 5-45

Application Series Page. Electronic Indicators 900, 901, 903 E.2 E.3. Dial Indicators 450, 451, 458 E.4 E.5. Transducer Probes 971 E.

The Synthesis and Improvement of a Force Balanced, Sealed Double Passive Radiator Bass Box for a Low Profile Home Speaker System

SCREENIT A30 A wooden frame filled with A-classed noise absorbing material, pinable and with foam laminated fabric. 40 mm thick.

APS4 Inductive Proximity Sensors

ABRT Series Air-Bearing Direct-Drive Rotary Stage

These devices require adequately trained and experienced operating personnel.

ZB4BV03 green pilot light head Ø22 with plain lens for BA9s bulb

net4more IP connected lighting system net4more sensors net4more Sensor 5DPI 14 un:c Multi-sensor for net4more system

VEHICLE SPECIFIC PARTS BUSES. Buses. School & Transit PAGE 585

Instruction Manual. 44AA Mouth Simulator according to ITU-T Rec. P51 with built-in power amplifier 44AB Mouth Simulator according to ITU-T Rec.

ZB4BW963 blue flush illuminated pushbutton head Ø22 spring return for integral LED

FULLY AUTOMATED 2 MICROPLATE ANALYZER

Cable entry systems for potentially explosive atmospheres

More Precision. optocontrol // Optical precision micrometers

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Optical encoding film disc mini board with integrated infrared photo sensor and LED operating indicator round, 5-pin output socket (180, DIN 41524)

TL Laser Systems for Tool Measurement

UULA FOCALSPEC 3D LINE CONFOCAL SCANNER DID THEY TELL YOU THAT NO-ONE CAN MEASURE IT? WE CAN.

Achat 206 passive full-range speaker. user manual

Transcription:

MSPM Bench Accessory of the KLIPPEL R&D and QC SYSTEM ( Document Revision 1.1) FEATURES Pressure chamber with clamping platform Sealed outlet for ¼ microphone Pneumatic excitation of small diaphragms APPLICATION Passive excitation of microspeaker, headphone, tweeter and microphone suspension parts Determine linear and nonlinear membrane parameters using the MSPM Lite/Pro Perform 3D scans of a bare membrane without motor, using SCN DESCRIPTION The MSPM-Bench (Micro Suspension Part Measurement) is designed for the measurement of the suspension parameters of small suspension parts (micro-speakers, headphones, tweeters, microphones). The MSPM Bench is a small pressure chamber designed to produce high sound pressures. It is used to pneumatically excite a clamped small diaphragm passively to monitor its vibration behavior. A sealed outlet is used for a microphone to measure the sound pressure in the chamber directly. Article number #2500-601 CONTENT 1 Components of MSPM Bench... 2 2 Preparing a Measurement... 4 3 Using different laser stands... 5 4 Limits... 6

MSPM Bench 1 Components of MSPM Bench 1 Components of MSPM Bench 1.1 MSPM Bench Set MSPM Bench MSPM Bench Inlay Loudspeaker Hardware for the measurement of small suspension parts (micro-speakers, headphones, tweeters and microphones). Inlay for the pressure chamber to reduce the air volume and to increase the possible sound pressure Loudspeaker to actively drive the pressure chamber 1.2 Additional Components required Microphone Laser Stands A 1/4" microphone is required for sound pressure measurement in the pressure chamber. Recommended Product: MIC 40PP-S1 The MSPM Bench is designed to work with one of the following laser positioning devices 3D Scanner (Scanning Vibrometer System SCN) (Art. #:2510-001) LST Bench (Art. #: 2500-310) + Translation Stage Pro Driver Stand (Art. #:2211-002) + Translation Stage 1.3 Measurement DUTs DUTS The size of the supported diaphragms depends on the clamping adapter. Using the standard clamping, diaphragms with a diameter up to 45mm; using the extended clamping, diaphragms up to 70mm can be mounted on the MSPM Bench. The Diaphragm should be clamped or glued sealed into a stiff panel. Any material (plastic, metal, epoxy, etc. may be used) Panel may be up to 3mm thick. KLIPPEL R&D System Page 2 of 6

MSPM Bench 1 Components of MSPM Bench The outer dimension of the panel should be between 50mm and 70mm. A ring with inner diameter of 45mm is used to press the panel on a sealing ring. The outer dimension of the panel should be between 75mm and 80mm. A ring with inner diameter of 70mm is used to press the panel on a sealing ring. KLIPPEL R&D System Page 3 of 6

MSPM Bench 2 Preparing a Measurement 2 Preparing a Measurement Unscrew clamping ring Unscrew the clamping ring from the enclosure. Place the DUT on the platform. Fix the DUT Fix the DUT between the two mounting parts using the 4 screws. Prepare the Sensors Insert and connect the microphone. Close the outlet. Connect the driving speaker. Place the MSPM bench on one of the Laser positioning devices. Direct the laser beam to the center of the membrane. Potentially a white dot is needed on the membrane for proper reflection. Adjust the laser position so that the laser is in its center position. KLIPPEL R&D System Page 4 of 6

MSPM Bench 3 Using different laser stands 3 Using different laser stands Pro Driver Stand Clamp the MSPM Bench on the screws between the platforms or on the lower platform into the Pro Driver Stand. LST Bench Place the MSPM Bench on the LST Box and close the fast clamps of the MSPM-Bench Laser Scanner Place the MSPM Bench on the Laser Platform and connect the driving speaker with the speaker clamps. Adjust the laser using the motor controller. Mount the MPSM bench to the turntable, using the included M10 screws. KLIPPEL R&D System Page 5 of 6

MSPM Bench 4 Limits 4 Limits Parameter Conditions Min Typ Max Unit DUT Mounting plate Dimensions 50 60 80 mm Thickness 3 mm Diaphragm Diameter 70 mm Resonance frequency 100 2500 Hz MSPM CLAMPING SET Operation Maximum Sound Pressure in Chamber continuous (<40s) 156 dbspl Short term (<5s) 160 dbspl Input voltage continuous (<40s) 12 V Short term (<5s) 19 V Dimensions width 250 mm height 150 mm weight 4,5 Kg Find explanations for symbols at: http://www.klippel.de/know-how/literature.html Last updated: August 18, 2017 KLIPPEL R&D System Page 6 of 6