-C5RS-LC RS232 EXTENDER

Similar documents
ST-C5VRS-600 VIDEO AND RS232 EXTENDER Installation and Operation Manual

XTENDEX Series ST-C5USBD FOOT DVI and USB Extender via CAT5e/6 Installation and Operation Manual

USB-C5 USB-C5-CE USB EXTENDER Installation and User Guide

PRIMUX Series. PRIMUX-RDSW PRIMUX Redundancy Switch Installation and Operation Manual

EXTENDERS Installation and Operation Manual

ST-C6USBH-300 ST-C6USBHU-300 ST-C6USBH-IR-300 ST-C6USBHU-IR FOOT USB, HDMI AND IR EXTENDER Installation and Operation Manual

ETH-4X1-G / 2X1-G / 2X1

ST-C5VA-WL500 WALL MOUNT VGA VIDEO AND STEREO AUDIO EXTENDER

VOPEX Series VOPEX-C5VA-xC1000 Video/Audio Splitter/Extender Installation and Operation Manual

EXTENDERS Installation and Operation Manual

Wiring and Configuration Instruction

ST-2FODVI-LC DVI Extender via Fiber Optic Cable Installation and Operation Manual

XTENDEX Series. ST-IPHD-LC HDMI Over IP Extender Installation and Operation Manual

ENVIROMUX-DCLM-6 DC Voltage and Current Monitor

NTI. KEEMUX Series. KEEMUX-P2 (2-Port PS/2 KVM Switch) INSTALLATION / USER GUIDE R NETWORK TECHNOLOGIES INCORPORATED

ST-IPHD-L/R-2GOPOE HDMI Over Gigabit IP Extender with Power over Ethernet (POE) Installation and Operation Manual

Mounting ears as received from NTI. Rear View of ENVIROMUX-S5VDC

E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation and Operation Manual

NTI. KEEMUX-P4-LC (4-Port PS/2 KVM Switch) INSTALLATION / USER GUIDE R NETWORK TECHNOLOGIES INCORPORATED

ENVIROMUX Series Installation Instruction For:

EXTENDERS Installation and Operation Manual

VOPEX Series. VOPEX-2/4KVIM-A VOPEX PS/2 KEYBOARD, MONITOR, and MOUSE SPLITTER Installation and Operation Manual

ST-C6USBH(E)-HDBT 328 FOOT HDMI USB KVM Extender over HDBaseT Installation and Operation Manual

VEEMUX Series. SM-4X4-DVI SM-8X8-DVI DVI Video Matrix Switch Installation and Operation Manual

RS-232 Connector Pin Assignments

Bluetooth RS-232 Dongle. User s Manual BTS-100

Appendix A Cable Pinouts

Cable Pinouts. SRP I/O Module

Industrial 1-Port Coax/UTP Long Reach PoE+ 4-Port. 10/100TX PoE Extender LRP-104CET. User s Manual

SoundwebTM. Installation Guide

USB-SUN USB TO SUN ADAPTER Installation Manual

VOPEX NTI. PS/2 KEYBOARD, MONITOR & MOUSE SPLITTER Installation and Operation Manual. VOPEX Series NETWORK TECHNOLOGIES INCORPORATED

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

VMI. Technical Documentation. 600 Industrial Drive, New Bern, N.C (tel / fax /

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

SOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch

General Operating, Maintenance and Installation Manual

24-Port Gigabit Ethernet Switches

SER-4485-SI-M USER S MANUAL

RS-232 to RS-422/485 Converter with 3KV Isolation Protection

MGate 4101-MB-PBS Series

HI-RES VGA USB KVM EXTENDERS

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

DL-HDM44A-H2 Quick Install Guide

Product Manual. USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

Micro-Switch/ port 10/100Mbps. Desktop Fast Ethernet Switch. (Auto MDI/MDIX) FEP T- 3 USER S MANUAL

4K HDR HDBaseT Extender B-560-EXT INSTALLATION MANUAL

8-Port 10/100TX 802.3at PoE + 2-Port 10/100TX Desktop Switch FSD-1008HP. User s Manual

Installation and Operation Manual

Features and Benefits. Certifications

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

HDBaseT EXTENDER B-520-EXT-230-RS-W INSTALLATION MANUAL

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

PRIMUX CAT5 KVM System Quick Start Guide

1275 Danner Dr Aurora, OH KEEMUX-USBV-2U (2-Port USB KVM Switch) NTI NETWORK TECHNOLOGIES INCORPORATED

NPort 5400 Series Quick Installation Guide

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

HDBaseT EXTENDER B-520-TX-230-IR B-520-TX-330-IR INSTALLATION MANUAL

USB 2.0 RG2304GE-LAN. 4-Port USB 2.0 Gigabit Ethernet LAN Extender System. User Guide

MESR Port Industrial Modbus Gateway. Specifications Power. MESR424_r000_2913ds

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

DGH A3000 Configuration Guide For use with DGH Modules

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date:

515RTAAIC Interface Converter

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

DL-HD2100 Quick Install Guide

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

TRP-C06H User s Manual

8-Port 10/100TX 802.3at PoE + 1-Port 10/100/1000T + 1-Port 100/1000X SFP Desktop Switch FGSD-1011HP. User s Manual

DL-FHD2 Quick Install Guide

KFC-200. Installation Guide

DT Desktop Series

4170 POS System Installation Guide

USB 2.0 RG port USB m Cat 5e Extender System. User Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

Weight ounces Panel Fasteners... Four holes to accept four 16x32 machine screws NEMA Rating... NEMA 1

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

Moxa TCC-100 Series User s Guide

USB 3.1 CAT6A/7 EXTENDER

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

Quick Start Guide Elinx ESW100 Series. 5 and 8 port Unmanaged Ethernet Switch

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at


IPC194. ipconv Protocol Converter

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

Moxa TCC-100 Series Hardware Installation Guide

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

INDUSTRIAL POE SWITCH

F1000 User's Manual. (Version: V1.01)

T1K MODBUS Base Controller Specifications

CTS-iCPE Gateway Controller User s Manual Version: Revision B1

Installation and Operation Manual. Ethernet Interface for SIMREX Radio Modems. SIMREX P/N: MAN.UBRIDGE Rev. B APRIL 2005

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

USB Raven Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide

Transcription:

XTENDEX Series ST-C5RS-LC RS232 EXTENDER Installation and Operation Manual ST-C5RS-LC RS232 Extender Man249 Rev. 10/30/17

TRADEMARK XTENDEX is a registered trademark of Network Technologies Inc in the U.S. and other countries. COPYRIGHT Copyright 2003-2017 by Network Technologies Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written consent of Network Technologies Inc, 1275 Danner Drive, Aurora, Ohio 44202. CHANGES The material in this guide is for information only and is subject to change without notice. Network Technologies Inc reserves the right to make changes in the product design without reservation and without notification to its users. Note: Shielded CAT 5,5e, or 6 cable must be used to connect to LOCAL and REMOTE units in order to meet CE emission and immunity requirements. Note: CATx connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products should not be run underground, outdoors or between buildings. WARNING: Outdoor or underground runs of CATX cable could be dangerous and will void the warranty. WARNING: The CATx connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products must be wired straight through (pin 1 to pin 1, pin 2 to pin 2, etc.) The use of a CROSSOVER CABLE will damage the extender and void your warranty. i

TABLE OF CONTENTS Introduction... 1 Materials... 1 Features and Functions... 2 Limitations... 3 Preparation for Installation... 3 Installation... 4 Cable Connections... 4 Plug-in and Boot Up... 5 DIN Rail Mounting... 6 Technical Specifications... 7 Interconnection Cable Wiring Method... 7 Warranty Information... 8 TABLE OF FIGURES Figure 1- Connect Local extender to CPU... 4 Figure 2- Connect the Remote extender to the device... 4 Figure 3- Connect CATx cable... 5 Figure 4- Connect optional power supply... 5 Figure 5- View looking into RJ45 female... 7 ii

INTRODUCTION The XTENDEX RS232 Extender extends one RS232 serial device up to 3,935 feet (1,200 meters) over a single CAT5e/6/7 cable. Features Include: Full duplex data communication. Compatible with all RS232 protocols. Sends RS232 data at 921.6 kbps up to 328 feet (100 meters) and 115.2 kbps up to 3,935 feet (1,200 meters). Supports Plug-n-Play specifications. Pure hardware design, no software or drivers required. DIN-rail mountable Ideal for many applications, including: o Extending serial touch screen monitors. o Transferring data or files between computers. Power Supports self-powered devices. Powered by attached devices though DB9 serial cable. If additional power is required, a 9-30VDC power supply can be wired to the screw terminal pair (sold separately). Regulatory Approvals CE, FCC, RoHS MATERIALS Materials supplied with ST-C5RS-LC: NTI XTENDEX RS232 Extender- Master and Slave Unit 2- DIN Rail mounting clips with screws One 6-inch DB9 male-to-male null modem serial cable Note: Shielded CAT5e,6 or 7 cable must be used to connect to LOCAL and REMOTE units in order to meet CE emission requirements. Contact your nearest NTI distributor or NTI directly for all of your KVM needs at 800-RGB-TECH (800-742-8324) in US & Canada or 330-562-7070 (Worldwide) or at our website at http://www.networktechinc.com and we will be happy to be of assistance. 1

FEATURES AND FUNCTIONS 7 6 1 2 (ON SIDE) 4 3 5 1. Green Tx LED- flashes when data is being transferred 2. Yellow Rx LED- flashes when data is being received 3. CAT5- RJ45 female- for connecting the CAT5e/6/7 cable 4. Terminal Block- for connecting 9-30VDC power supply if required (optional- sold separately) 5. RS232 Connector- 9D female- for connecting to the RS232 port on the CPU (Master Unit) or serial device (Slave Unit) 6. PWR- connection jack for an AC adapter (3.5x1.3mm DC Plug)- another alternate power connection method 7. LED- Illuminates red when power has been supplied to the extender 2

LIMITATIONS Hot-plugging of devices is supported provided devices were originally connected at power-up. The extender supports all baud rates up to 115,200 baud up to 3,935 feet (1,200 meters) or 921,600 baud up to 328 feet (100 meters) and the attached CPU must be configured accordingly. PREPARATION FOR INSTALLATION Locations should be chosen for the serially-controlled device and CPU that also has space to connect the Master and Slave Units within the distance provided by the cables. The CATX cables must be run to the locations where the Master and Slave Units will be connected. Be careful to route the cables away from any sources of magnetic fields or electrical interference that might reduce the quality of the video signal (i.e. AC motors, welding equipment, etc.). All cables should be installed in such a way that they do not cause stress on their connections to the equipment. Extended lengths of cable hanging from a connection may interfere with the quality of that connection. Secure cables as needed to minimize this. Properly shut down and disconnect the power from the CPU and serial device to be separated. If other equipment is involved whose connections are being interrupted, be sure to refer to the instruction manuals for that equipment for proper disconnection and re-connection procedures before proceeding. Master and Slave units should be grounded through either a serial device or CPU that uses a 3-prong power cord. If only one unit is grounded, shielded CAT5 cable should be used. Note: CATX connection cable used between NTI XTENDEX Series Master and Slave or any XTENDEX Series products should not be run underground, outdoors or between buildings. WARNING: Outdoor or underground runs of CATX cable could be dangerous and will void the warranty. 3

INSTALLATION Cable Connections 1. Connect a DINT-xx cable (9DB male to 9DB female wired straight through, pin-to-pin) cable between the DB9 connector on the Master (see label on back of extender) and the serial port on the back of the CPU (or other serial controlling device). Figure 1- Connect Local extender to CPU 2. Connect the supplied 6 inch 9DB male to 9DB male null serial cable between the Slave (see label on back of extender) and your self-powered serially-controlled device. Figure 2- Connect the Remote extender to the device 4

3. Connect a CAT5e/6/7 cable between the Master and Slave units. For devices controlled by up to 115,200 baud rate, this cable can be up to 3935 feet in length (1200 meters). For devices controlled by higher baud rates (up to 921,600), this cable can be up to 328 feet in length (100 meters). Figure 3- Connect CATx cable WARNING: The CATx connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products must be wired straight through (pin 1 to pin 1, pin 2 to pin 2, etc.) The use of a CROSSOVER CABLE will damage the extender and void your warranty. Plug-in and Boot Up 1. Power up the CPU and extended device. The red power LED on each extender should illuminate. Try sending communication between the CPU and the serially-controlled device. The CPU and device should each react as if they were directly connected to each other. Note: The yellow ( Tx ) and green ( Rx ) LEDs on each RJ45 connector will flash anytime data traffic is passing between the Master and Slave, indicating proper CATx cable connection and communication. If insufficient power is provided by the connection to the CPU or the serial device, the red power LED will not illuminate. In this case, an external power supply (9-30VDC) will need to be connected (sold separately- contact NTI). Figure 4- Connect optional power supply 5

DIN Rail Mounting The extenders can be easily DIN rail mounted with the provided DIN rail mounting clips. the two holes on the back of the extender (screws are provided). Connect the clip to the extender using Spring clips Install screws to secure clip to extender Then set the extender on the rail against the spring clips side first, apply a small amount of pressure and rotate the extender up to lock the rail into the top of the clip. (See images below.) Release the extender to fully engage the clip on the rail. Rear View Front View 6

TECHNICAL SPECIFICATIONS RS232 Connectors RS232 Baud Rate RS232 Compatibility Communication Mode RS232 protocols supported 9DB female 115,200 to 3935 feet (1200 meters) 921,600 to 328 feet (100 meters) RXD,TXD,RTS,CTS Full Duplex Data All Interconnect Cable CAT5e/6/7 straight through cable for EIA/TIA 568 B wiring terminated w/ male RJ45 connectors Remote and Local Unit Power device powered through 9DB cable Optional: 9-30VDC adapter (if needed) Power Consumption 40mA / 360mW Operating Temperature -30 C to 75 C Operating humidity 5-95% Non-Condensing Dimensions WxDxH (In.) (Local or Remote) 1.63x3.13x0.88 Drivers required none Regulatory Approvals CE,FCC,RoHS WARNING: The CATx connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products must be wired straight through (pin 1 to pin 1, pin 2 to pin 2, etc.) The use of a CROSSOVER CABLE will damage the extender and void your warranty. INTERCONNECTION CABLE WIRING METHOD The connection cable between the Remote and Local is terminated with RJ45 connectors and must be wired according to the EIA/TIA 568 B industry standard. Wiring is as per the table and drawing below. Pair 3 Pin Wire Color Pair Function 1 White/Orange 2 T 2 Orange 2 R 3 White/Green 3 T 4 Blue 1 R 5 White/Blue 1 T 6 Green 3 R 7 White/Brown 4 T 8 Brown 4 R Pair 2 Pair 1 Pair 4 T 1 + R 2 - T 3 + R 4 - T 5 + R 6 - T 7 + R 8-9DB Female on Extender Figure 5- View looking into RJ45 female Pin Function 1 N/U 2 TXD 3 RXD 4 N/U 5 GND 6 N/U 7 CTS 8 RTS 9 N/U N/U = Not Used 7

9DB Male to 9DB Male Null Serial Cable Pin Assignments 9DBM Signal 9DBM Signal 1 --- Not connected 1 --- 2 TXD 3 RXD Connected to 3 RXD 2 TXD 4 ---- Not connected 4 ---- 5 GND Connected to 5 GND 6 --- Not Connected 6 ---- 7 CTS 8 RTS Connected to 8 RTS 7 CTS 9 --- Not Connected --- ---- 6 Inch Cable (Supplied) WARRANTY INFORMATION The warranty period on this product (parts and labor) is two (2) years from the date of purchase. Please contact Network Technologies Inc at (800) 742-8324 (800-RGB-TECH) or (330) 562-7070 or visit our website at http://www.networktechinc.com for information regarding repairs and/or returns. A return authorization number is required for all repairs/returns. Note: CATx connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products should not be run underground, outdoors or between buildings. WARNING: Outdoor or underground runs of CATx cable could be dangerous and will void the warranty. WARNING: The CATx connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products must be wired straight through (pin 1 to pin 1, pin 2 to pin 2, etc.) The use of a CROSSOVER CABLE will damage the extender and void your warranty. Manual 249 Rev. 10/30/17 8