Server Technology Technical Data Sheet

Similar documents
CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. Available in Basic, Metered, and Smart PDU models.

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)

CS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)

Sentry Metered, Smart, and Switched High Density 30 Receptacle 208VAC, 3-Phase 30A Products

Models. Specifications

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)

C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) Key Features

Fail-Safe Power Redundancy

How do I... If you manage a datacenter, we have a solution for you.

Server Technology Inc.

How do I... Sentry Power Manager Rack-Level Data Center Power Monitoring & Management. If you manage a datacenter, we have a solution for you.

Density in the Data Center

More outlets. More flexibility. Highest quality.

Introducing Server Technology s PRO1 Rack Power Distribution Unit

Server Technology White Paper

MODEL NUMBER: B IP2

Server Technology Inc.

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA

Data Center Power: Managing for Energy Efficiency and Cost Savings

MODEL NUMBER: B IP4

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA

MODEL NUMBER: B IP2-K

GigaVUE-2404 // Data Sheet

Sentry Power Manager (SPM) Software Security

Sentry Power Manager (SPM): Hub and Node Feature Part Numbers SPM-Hub and SPM-Node

SYSTIUM MODEL 526EX UATX

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

Zero Touch Provisioning (ZTP)

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

POWER. DA12-M Series. 12 Watts. Data Sheet. Total Power: 12 Watts Input Voltage: Vac # of Outputs: Single. Special Features

Power Distribution Units for Data Centers

ECO PDU. Features. PE5220sA

OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES

Polar PDUs POWER MANAGEMENT

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial

Electrical Specifications. Input Input range Vac Frequency. 90% typical at full load, nominal line. FCC Subpart J EN55022 Class B

Switched, Outlet Level Monitoring

PDU Inspired by Your Data Center. W IEC PDU Series

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

24-Port Gigabit Ethernet Switch w/ 12 Outlet PDU, 2 SFP and 8 PoE+ Ports, 120W

BACnet Router Start-up Guide

TRC-190 User s Manual

G GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number

Electrical Specifications

LED Driver. LED Driver. LED Driver

TRC-190 User s Manual

Solutions Guide for Cisco UCS B and C Series Servers

TESLA 1U GPU COMPUTING SYSTEMS

Electrical Specifications. Input Input range: Vac Hz, single phase AC. 92% typical at high line 50% load. FCC Subpart J EN55022 Class A

LightRules Network Infrastructure

controller data sheet JACE 8000 PRODUCT DEFINITION HARDWARE SPECIFICATIONS

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial

ECO PDU PE7108/PE7208

CONNECTRIX MDS-9250I SWITCH

BACnet Router Start-up Guide

VCL-TP, Teleprotection Equipment

CISCO Switch Catalyst 6500 Series Datasheet

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, WEBCARDLX Network Interface, LCD, USB, 8 Outlets

Electrical Specifications. Input Input range: (1200 W) (1000 W) Hz, single phase AC. > 91% typical at high line 50% load

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

ECO PDU PE5108/PE5208

CISCO AC/DC POWER SOLUTION FOR USE WITH CISCO OPTICAL PLATFORMS

Airmux-400, Airmux-5000 Optional Accessories

SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 3U Rack/Tower, Extended Run, WEBCARDLX Network Interface, LCD, USB, DB9

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules

Rack Power Distribution Unit AP7530, AP7540

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU

How do I... If you manage a datacenter, we have a solution for you. Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU.

FieldServer EZ Gateway Modbus to BACnet Start-up Guide FS-EZX-MOD-BAC

SmartOnline 208/240 & 120V 20kVA 18kW, Double-Conversion UPS, N+1, 14U, Network Card Slot, USB, DB9, Bypass Switch

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial

SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules

SmartOnline 20kVA On-Line Double-Conversion UPS, N+1, 14U Rack/Tower, 208/120V or 240/120V NEMA & C19 outlets

xin 4, xio 4x4 and xout 4

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Bel Power Solutions AC Power Distribution Unit (PDU) is used to distribute AC voltage in IT Racks following the Open Rack specification.

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

2301E ST Steam Turbine Control for Small Generator Applications

Citrix CloudBridge CB User Manual

Cisco Redundant Power System 2300

Temperature Alert. LAN-based Temperature and Humidity Data Logger

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial

Tsig TSG3200 Data Sheet

Hubport USB HUB Installation Guide Models: Hubport/4 Hubport/7 Hubport/14 /c Models: Hubport/4c Hubport/7c Hubport/4c DC Hubport/7c DC

RCOBN PH6TL21-D Power Monitoring, Outlet Level. Part Number

TZ 170 Quick Start Guide

Xcellis Workflow Extender (R520) Site Planning Guide

Managed Rack PDU MPH2 More efficient Simpler Better

KPW-T2P25. PoE Splitter. Industrial IEEE 802.3at High Power. User s Manual -1- DOC

USB Port USB 2.0 Hub Controller PRODUCT FEATURES. Data Brief

LTC 8600 Series Allegiant Matrix/Control Systems - Modular

Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY

SmartOnline 120V 1kVA 900W Double- Conversion UPS, 2U, Extended Run, Network Card Options, LCD display, USB, DB9 Serial

Internet Office 120V 750VA 450W Standby UPS, Ultra-Compact Desktop, USB

Who Needs Remote Power Management for Power Distribution, Power Measurement and Power Control of 48 VDC Equipment?

Dialogic DSI Signaling Gateway Based on Dialogic DSI SS7G3x Signaling Servers

IFS MCR-R15 Media Converter Rack User Manual

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, SNMPWEBCARD Option, LCD Display, USB, DB9 Serial

Switched econnect PDU

Transcription:

Technical Data Sheet -48VDC Switched Rack PDU 48DCWB-04-4X125-E0NB: 24kW (4) 125A Inputs and (4)125A Max Outputs Sep 2016 Version 1.0 This Intelligent PDU and Remote Power Manager minimizes the impact of locked-up routers, servers and other network devices on business-critical networks. CLECs, ILECs, ISPs and enterprises use this PDU to manage equipment in remote sites, co-location facilities and network operation centers. This PDU eliminates the need to dispatch a field service technician for manual intervention when devices lock-up. Using this PDU, the network operations center can quickly restart locked-up remote network servers to ensure that the network is fully operational around the clock.

Features and Specifications Disconnect Rated Circuit Protection Each output is protected by a fuse or circuit breaker and is rated for hot disconnect. Output Current Monitoring Network monitoring provides access to current draw at each output and alerts when high usage risks a tripped circuit. Output Control Cycle power to individual outputs or groups of outputs to reboot devices or to power off unused terminals. North America Master PDU Link PDU Inputs Outputs Input Voltage Rated Power 48DCWB-04-4X125-E0NB 48DCXB-04-4X125-E0NB (4) 125A Inputs (4) Switched Outputs -40 to -60 VDC 24kW @ -48VDC 125A Max Inputs Connector: 4 pair of 1/4-20 Stainless Steel Lugs Rating: 125A each -48VDC Outputs Connector: 4 pair of 1/4-20 Stainless Steel Lugs Rating: 125A maximum each -48VDC Circuit Protection All fuses are sold separately. Fuses and their values must be specified at time of order TPC (High Current) 10A P/N FUSE-TPC-10 15A P/N FUSE-TPC-15 20A P/N FUSE-TPC-20 25A P/N FUSE-TPC-25 30A P/N FUSE-TPC-30 40A P/N FUSE-TPC-40 50A P/N FUSE-TPC-50 60A P/N FUSE-TPC-60 75A P/N FUSE-TPC-75 100A P/N FUSE-TPC-100 125A P/N FUSE-TPC-125

Physical/Environmental Dimensions: 2.5U - 4.4" (112 mm) tall x 17.0" (432 mm) wide x 16" (407 mm) deep Weight: 30.3 lbs (13.27 kg) Shipping Dimensions: 19.7 x 19.7" x 6.5 (50.1 cm x 50.1cm x 16.5 cm) Weight: 35 lbs (15.9 kg) Operating Environment: 32 F to 104 F / 0 C to 40 C 8%RH to 90%RH non-condensing 6,500ft/2000m elevation Storage Environment: -40 F to 185 F / -40 C to 85 C 8%RH to 90%RH non-condensing 50,000ft/15km elevation Communications and Security 10/100 Mbps Ethernet (RJ-45 connector), RS-232 serial (RJ-45 connector) Two (2) temperature/humidity sensor inputs (4P4C), Link port (RJ-12) {also on Link CDU} Web-browser GUI and command-line-interface (CLI): HTTP/HTTPS, TLSv1, SSHv2, Telnet, SNMPv2c and v3 (GET, SET, Traps), IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP Certifications ctuvus Mark to UL 60950-1:2007 and CAN/CSA 22.2 No. 60950-1-07 + A1:2011 TUV T-Mark to EN 60950-1:2006 + A11 + A1 + A12 EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A FCC Class A, Part 15 CE Mark NEBS Level 3 Compliance / Switched PDU GR-1089-Core: Sections 1-4, 7, 9, & 10 GR-63-Core: Sections 4.1, 4.2, 4.3, 4.4, 4.5, & 4.7 ETSI EN 300 019-2-1 v2.1.2: 2000-09 ETSI EN 300 019-2-2 v2.1.2: 1999-09 ETSI EN 300 019-2-3 v2.2.2: 2003-04 ETSI EN 300 132-2 V2.2.2: 2007-10 Optional Accessories EMTH-1-1 Combination Temperature/Humidity Probe, 10ft (3m) SPM (Sentry Power Manager): - Monitor and manage multiple PDUs from a single point - Monitor and manage alarm conditions - Create reports and trends on stored data - Analyze power usage per phase - Optional appliance or virtual version - VMware Ready²

8 SERVER TECHNOLOGY, INC PROPRIETARY INFORMATION THIS DOCUMENT IS THE SOLE PROPERTY OF SERVER TECHNOLOGY, INC. THE RELEASE OF DATA CONTAINED IN THIS DOCUMENT AND THE REPRODUCTION OF THIS DOCUMENT, IN WHOLE OR IN PART, WITHOUT THE WRITTEN PERMISSION OF SERVER TECHNOLOGY, INC IS PROHIBITED. 7 RoHS COMPLIANT 6 5 4 3 REVISION HISTORY ZONE REV DESCRIPTION DATE APPROVED - 1 INITIAL DESIGN 6/26/2015 MAR/VB 2 1 THESE COMMODITIES, TECHNOLOGY OR SOFTWARE WERE EXPORTED FROM THE UNITED STATES IN ACCORDANCE WITH THE EXPORT ADMINISTRATION REGULATIONS. DIVERSION CONTRARY TO U.S. LAW IS PROHIBITED. D D NOTES: 1. DIMENSIONS ARE IN MILLIMETERS AND [ ] BRACKETS ARE IN INCHES. 406.40 [16.00] C 431.80 [17.00] C 22.22 [0.87] B B 469.00 [18.46] 455.80 [17.94] A 110.98 [4.37] 76.20 [3.00] 44.45 [1.75] SERVER TECHNOLOGY, INC. TOLERANCES UNLESS OTHERWISE SPECIFIED (UNLESS OTHERWISE SPECIFIED) * INTERPRET DRAWING IAW ASME Y14.100-2000 LINEAR DIMENSIONS: * DIMENSIONING & TOLERANCING IAW ASME Y14.5M-2007.X = ±.500 * REMOVE ALL BURRS AND SHARP EDGES.2 R MAX.XX = ±.300 * DIMENSIONS ARE IN MILLIMETERS 1040 Sandhill Drive Reno, NV 89521.XXX = ±.130 * DIMENSIONAL LIMITS APPLY AFTER PLATING/COATING. DO NOT SCALE DRAWING DRAWING TITLE: ANGULAR DIMENSIONS: THIRD ANGLE PROJECTION X = ± 1 A OUTLINE DRAWING, ENA-48125-3G X.X = ±.5 A X.XX = ±.25 SYMBOLS MATERIAL: 8 DETAIL A SCALE 1 / 2 "CX" EXPANSION VERSION 7 6 5 4 Q # = CRITICAL DIM. S = COSMETIC SURFACE FINISH: 3 SIZE CAGE CODE DWG NO. REV B 049V0 412-48125-3 1 SCALE: NONE 1 OF 1 SHEET 2 1

Additional Information available at the time of purchase. See the Support Options on the website, or contact your local representative for more information. Patents: Information on patents is available on the website at: www.servertech.com/products/patents PRO2, HDOT, PIPS, POPS, CDU, Sentry,, the ST Eye logo, and the globe logo are U.S. registered trademarks of, Inc. Power Pivot, EZip, and StartUp Stick are trademarks of Server Technology, Inc. Information in this document is current as of time of publishing. Contact your representative for the most up-to-date information. 2016, Inc. ¹ Cisco EnergyWise is a U.S. registered trademark of Cisco Technology, Inc. ² VMware and VMware Ready is a registered trademark or trademark of VMware, Inc. in the United States and/or other jurisdictions. HEADQUARTERS - NORTH AMERICA, Inc. 1040 Sandhill Drive Reno, NV 89521 United States 1.775.284.2000 Tel 1.775.284.2065 Fax sales@servertech.com www.servertech.com www.servertechblog.com Western Europe, Middle East and Africa Fountain Court 2 Victoria Square Victoria Street St. Albans AL1 3TF United Kingdom +44 (0) 1727 884676 Tel +44 (0) 1727 220815 Fax Central Europe, Eastern Europe and Russia Niederlassung Deutschland LLC 42119 Wuppertal Germany Tel: + 49 202 693917 x 0 Fax: + 49 202 693917-10 APAC Room 2301, 23/F, Future Plaza 111-113 How Ming Street, Kwun Tong, Hong Kong Direct line: +852 3916 2048 Fax Line: +852 3916 2002