Sentry Metered,, and High Density 30 Receptacle 208VAC, 3-Phase 30A Products The shift to 3-Phase power in North American data centers has driven demand for PDUs with increased flexibility. Mixed C13 / C19 receptacles allow more options for powering both 1U devices as well as blade servers. With these needs in mind Server Technology has launched a new family of 30 receptacle products to help power your facility. Metered - The C-30V product family includes local LED input current monitoring, allowing network engineers to utilize the CDU s True RMS Power Monitor to precisely measure the current draw (in amps). As new servers and devices are added to the - The CS-30V and CL-30V add IP monitoring to the CDU. Use the network interface to provide power temperature and humidity levels via Web browser, or receive SNMP-based alarms and email alerts when conditions exceed defined thresholds. Connect the Expansion CDU (CL) to a Master unit (CS) for power monitoring of separate power circuits from a single IP address. Network Link to an Temperature & expansion CDU Humidity CDU s combine remote configuration and management with power distribution and environmental monitoring. Reboot a single server with one command. The CW-30V and CX-30V products provide (24) managed IEC C13 along with (6) managed C19 outlets. Network Outlet Control Link to an expansion CDU Temperature & Humidity
Models North America Intelligence Model Numbers Input Input Plug Metered C-30VDD354C2 Metered C-30VDE354C2 Metered C-30VYL354C2 Metered C-30VYM354C2 CS-30VDD354C2 (Master) CL-30VDD354C2 (Expansion) CS-30VDE354C2 (Master) CL-30VDE354C2 (Expansion) CS-30VYL354C2 (Master) CL-30VYL354C2 (Expansion) CS-30VYM354C2 (Master) CL-30VYM354C2 (Expansion) CW-30VDD354C2 (Master) CX-30VDD354C2 (Expansion) CW-30VDE354C2 (Master) CX-30VDE354C2 (Expansion) CW-30VYL354C2 (Master) CX-30VYL354C2 (Expansion) CW-30VYM354C2-012 (Master) CX-30VYM354C2-012 (Expansion) Specifica ons Input Digital True RMS input current measurement Power Cord: Top Entry Output Type: (24) IEC 60320/C13 and (6) IEC 60320/C19 Receptacles Voltage: 208V, 2Ph Display (3) Input current LED corresponding to each phase Protec on 20A Fuse with tool-less retrac on, meets UL 60950-1 requirements (Bussman SC-20 fuses) 3 Branches with (8) IEC 60320/C13 & (2) IEC 60320/C19 Outlets per Branch
Dimensions and Weights Model Dimensions (LxWxD) Shipping Dimensions (LxWxD) Shipping Weight All & Products: Interface and Protocol Support Master PDU 10-100 Mbps Ethernet (RJ-45 connector) RS-232 serial (RJ-45 connector) (2) temperature/humidity sensor inputs (RJ-11) Link port (RJ-12) Web browser and serial interface HTTP/HTTPS, SSLv3/TLSv1, SSHv2, Telnet SNMPv2 and v3 (TRAPS, GET, SET) IPv4 and IPv6 LDAPv3/LDAPS, TACACS+, RADIUS Expansion PDU Link port (RJ-12) & / Products: Temperature/Humidity Sensors (2) Combina on temperature/humidity sensor inputs per Master PDU Environmental Requirements Opera ng Storage Temperature 32 to 122 F (0 to 50 C) -40 to 185 F (-40 to 85 C) Rela ve Humidity 8% to 90% non-condensing 8% to 90% non-condensing Eleva on (above MSL) 0 to 10,000 (0 to 3047 m) 0 to 50,000 (0 to 15239 m) Cer fica ons North America ctuvus Mark to UL 60950-1: 2007 and CAN/CSA 22.2 No. 60950-1-07 FCC Class A, Part 15 EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A Warranty 2 years Accessories 76.0 x 1.75 x 2.25 in. (193.0 x 4.4 x 5.7 cm) 83 x 10 x 5 in. (211 x 26 x 13 cm) 24 lb. (10.8 kg) Descrip on Temperature/Humidity Sensor Environmental Monitor Control Unit Part Number EMTH-1-1 EMCU-1-1
Locking Power Cord Op ons UL Rated Plug Plug Type* Connector Length, (m) Part Number C14 Straight C13 1.5 (0.45) CAB-S1413-CA C14 Straight C13 3.0 (0.91) CAB-S1413-FA C14 Straight C13 6.0 (1.82) CAB-S1413-NA C20 Straight C19 1.5 (0.45) CAB-S2019-CA C20 Straight C19 3.0 (0.91) CAB-S2019-FA C20 Straight C19 6.0 (1.82) CAB-S2019-NA C14 Straight C19 6.0 (1.82) CAB-S1419-NA C20 Straight C13 6.0 (1.82) CAB-S2013-NA C14 Le Angle C13 1.0 (0.30) CAB-1506A C14 Le Angle C13 1.5 (0.45) CAB-L1413-CA C14 Le Angle C13 2.0 (0.61) CAB-L1413-DA C14 Le Angle C13 4.0 (1.21) CAB-1506G C20 Le Angle C13 3.0 (0.91) CAB-L2013-FA * Note: the bend of the angled cords is referenced with the ground pin at the top HEADQUARTERS - NORTH AMERICA Server Technology, Inc. 1040 Sandhill Drive Reno, NV 89521 United States 1.775.284.2000 Tel 1.775.284.2065 Fax sales@servertech.com www.servertech.com www.servertechblog.com U.K. Office Western Europe, Middle East and Africa Fountain Court 2 Victoria Square Victoria Street St. Albans AL1 3TF United Kingdom +44 (0) 1727 884676 Tel +44 (0) 1727 220815 Fax Central Europe, Eastern Europe and Russia Niederlassung Deutschland Server Technology LLC 42119 Wuppertal Germany Tel: + 49 202 693917 x 0 Fax: + 49 202 693917-10 Mobile: + 49 152 22 76 76 22 Singapore Office APAC 37th Floor Singapore Land Tower 50 Raffles Place Singapore 048623 Phone: +65 9739.0396 Fax: +65 6234.4574 Server Technology, Inc. Rev A 1/2013 version. Information in this document is subject to change without notice. PDUs Direct trademark of PDUs Direct. Printed in US.