Communication Gateway COM 500. Product Guide

Similar documents
Communication Gateway COM 610. Product Guide

SMS 510, CAP 505 LON Gateways Configuration Configuration Guide

SREDU Double Connection Option Card for Lon Star Coupler RER 111

SYS 500 Installation 1MRS MEN. Notice 1. Notice 2. Notice 3. Trademarks

Relay configuration and setting tool package

Relay Product Engineering Tools

MicroSCADA Pro COM 500 *4.1. User s Guide

Substation automation products. MicroSCADA Pro for substation automation

LON bus communication devices 1MRS MBG Page 1 Issued: April 1999 Status: New Data subject to change without notice

COM600 Station Automation Series External OPC Client Access 3.1. User's Guide

LNT 505 Installation and Commissioning Manual

Relay setting toolbox

RER 123 Bus Connection Module. Technical Description

COM600 Station Automation Series MNS is Connectivity (OPC) 3.2. User's Guide

Power Products. Protection and Control IED Manager PCM600 Product Guide

Grid Automation Products. MicroSCADA Pro Substation automation applications.

MicroSCADA Pro Substation automation applications.

REM 543 Machine Terminal. User s Guide for Modbus Configurations

Station Automation COM Logic Processor User's Manual

SPA-ZC 200/SPA-ZC 202 IEC /SPA-gateway Modules. Installation Manual

Protection and Control IED Manager PCM600 Product Guide

LON bus LonWorks Network in Protection and Control Systems. User s manual and Technical description

EuroGateway. IEC Substation Automation System Communication Gateway

Connectivity Packages. User's Guide - ANSI Version

MV Process Application Library LIB 510. Product Guide

Power Products. Station Automation COM600 Product Guide

Protection and Control IED Manager PCM600 Product Guide

CONTENTS... 2 COMTROLL SAS. SURVEILLANCE AND AUTOMATION SYSTEM...

Data communication and reporting unit

Grid Automation Controller COM600 How it fits into the Smart Grid?

Communicate IT Software module DR-COM. Buyer s Guide

The System for Power Automation

CAP 505 Relay Product Engineering Tools Installation and Commissioning Guide

Arctic family of wireless communication products Secure wireless connectivity

Power Products. Station Automation COM600 Product Guide

!',' *!2(6!'!'!0!! - (''!- 2(6!

Relion 630 series. Load-shedding controller PML630 High performing load-shedding solution for industrial and utility power networks

Data communication and reporting unit

MicroSCADA Pro SYS Connecting LONWORKS Devices

M2M Gateway ARM600 Product Guide

MicroSCADA Pro SYS 600C 1.93 User's Guide

SPA-ZC 302. Profibus-DPV1/SPA Gateway. Product Guide. spa-zc302_rightco300

MINER-S Station Controller. Substation Automation

Wireless Gateway ARG600 Product Guide

Lab Determining Data Storage Capacity

I/A Series HARDWARE Product Specifications

Installation Instructions for Medisoft 15 Network Professional

Pow-R-Command System Overview

EC-BOS-8 Multi-protocol Web Building Controller

MicroSCADA Pro SYS 600 *9.1

Supervisory Controllers

Terminal tool box CAP 540*1.2

EC-BOS-8 Multi-protocol Web Building Controller

Anybus Communicator for LonWorksLWTool

IDM DATA ACQUISITION SYSTEM

Ethernet Adapter. Modbus/TCP Brigde. Installation and Commissioning Manual

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

High Impedance Protection Relay SPAE010, SPAE011. Product Guide

1. SALESLOGIX SYSTEM REQUIREMENTS

MicroSCADA Status Codes

INDeX Technical Update

SPA-ZC 17. Bus connection module SPA-ZC 17. User s manual and Technical description. Tx SC Rx BB BM MB MM SPA / RS 485 POWER SLAVE 1 MASTER 0

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

CAP581. Configuration Tool for COM581. p Operating Instructions. 1MRB Uen Edition July 2005

Client Server Protocol Implementation

/ sicam SICAM CMIC The smart cube for your distribution network Answers for infrastructure and cities.

StoneGate FW/VPN. Hardware Requirements for Version 5.2.0

Jehanpour Ranjkesh, Integrator Partner Seminar 2012 Station level product news Automation Controller COM600

IP67 IP20. Controllers Open Flexible Compact SPEEDWAY. Programmable. Fieldbus Couplers. Programmable. Fieldbus Controllers

IDS SAS. Station Automation System for Complex Applications

SCADAPack Smart RTU

Metasys Installation and Platform Requirements

Directional or Non-Directional Earth-Fault Relay REJ 527. Product Guide

ROCON RPC 116. SUBSTATION AUTOMATION Central unit for substation automation

Scout-S Station Controller

DECS 2.0. Danfoss Energy Control System. Data sheet. Description DECS 2.0

CAP 505. User s Guide

INDUSTRIAL PC MOUNTED IN PANEL

DECS 2.0 Danfoss Energy Control System

Station Automation COM HMI Configuration Manual

Netcon 500. The Cyber Secure RTU Gateway

SCADAPack ES. Smart RTU

Integrated Access Control Alarm Management System

SM100. On-Line Switchgear Condition Monitoring

IBM PC Options Compatibility Matrix

This Datasheet is for the IC693PBM200. Profibus DP Master Module.

PANEL-MOUNTED INDUSTRIAL PC. ports (Ethernet, USB, serials, parallel, peripherals commonly utilized in the industrial

EN7000 & Anybus Communicator EIP/MODBUS-RTU user guide 1

////// SUBSTATIONS. Control command and local Scada

DISCONTINUED MODEL Replaced with Model MSRPAC-2005

Earth-fault Relay SPAJ 110 C. Product Guide

Blackout 101. Dr. B. Don Russell Texas A&M University. Dr. Bruce Wollenberg University of Minnesota. Mr. John McDonald KEMA, Inc.

WAGO-I/O-IPC. PC Performance in the Field

Grid Automation packaged solutions Optimal automation of medium voltage grids

Real-Time Automation Controllers (RTACs) Economical, multifunctional, compact real-time automation control

Protect IT MNS Motor Management INSUM. Dual Redundancy Guide Version 2.3 ABB

TCP. Control and Protection Terminal Data sheet

High impedance protection relay

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

StoneGate IPS. Hardware Requirements for Version 5.2.0

Transcription:

Communication Gateway COM 500 Product Guide

Communication Gateway COM 500 1MRS750446-MBG Issued: May 1999 Status: Updated Version: B/16.11.2001 Data subject to change without notice Features Communication gateway Interface to a wide range of substation communication buses Interface to a wide range of SCADA communication protocols Interface to MicroSCADA Part of ABB s Distribution Automation system Application COM 500 is a communication server which provides communication gateway functions for mapping signals between process devices and up to four higher-level systems. The higher-level system here is called the Network Control Centre (NCC). It is the system to which COM 500 sends information for monitoring and controlling the process of the customer and from which COM 500 receives process control commands. COM 500 also handles system co-ordination tasks, such as dynamic assignment of control command authorization and communication supervision. COM 500 supports a variety of protocols for connection to higher-level systems. It is typically connected to a network via a telecontrol protocol, e.g. IEC 60870-5-101, DNP 3.0 or Modbus RTU. Different protocols, such as SPA, LON and IEC 60870-5-103 can be used to connect process devices to COM 500. Design The COM 500 is used in commercial PCs running the Windows NT operating system. Scalability in respect of hardware is accomplished by selecting the computer according to the performance requirements. Hardware scalability is also supported in respect of the number of communication interfaces available. In small configurations the computer COM ports can be used. Extensions are made by adding communication boards to the computer and by distributing the communication interfaces to communication front-ends on a local area network. COM 500 is based on MicroSCADA technology. It can be integrated into the SYS 500 system server to obtain cost savings in compact system solutions. As an option the COM 500 may be provided with an human system interface (HSI) for monitoring and fault diagnostics of the communication between the COM 500 communication gateway and higher-level systems. The HSI also provides the user interface needed for signal engineering and communication diagnostics. The COM 500 COMTool is used for signal engineering, making the cross-reference between down-stream and up-stream communication. Up to 32 COM lines (by using additional COM boards) and up to four LON lines can be connected to one COM 500 gateway unit. Hardware requirements COM 500 requires at least: A 300 MHz Pentium processor. Multiprocessor computers may also be used. 128 MB RAM, less memory may result in degraded performance. About 100 MB hard disk space for the application. The total hard disk space recommended is at least 1 GB. Any SCSI or IDE controller supported by Windows NT may be used Options: A CD-ROM drive is recommended to be used for the installation of Windows NT and the COM 500 software. A 3.5 /1.44 MB floppy drive or a 4/8 GB DAT tape drive is recommended for system backup purposes. Any Ethernet adapter supported by Windows NT may be used for connecting the base system computer to the LAN. For time synchronization, a PC 31/32 radio clock board from Meinberg Funkuhren, Germany, may be installed in the PC. The board 3

Communication Gateway COM 500 1MRS750446-MBG contains a radio receiver for the Frankfurt DCF-77 77 khz radio transmitter. Optionally, the PC 32 board can be connected to a GPS receiver with a serial cable. An alternative to time synchronization is also offered by the LON Clock card in the LON Star Coupler RER 111. Technical data Protocols supported by COM 500 are shown in Table 1. The master protocols are used in process communication and slave protocols are used in higher-level communication. CPI is also listed, though it is not actually a protocol but rather an interface that can be used for implementing new protocols in the Micro- SCADA environment. If a protocol that is not listed needs to be used, it is possible to program the protocol conversion using the CPI. The programming languag is C. Table 1: Protocols supported by COM 500: Protocol SPA LON LAG 1.4 t IEC 60870-5-103 IEC 60870-5-101 IEC 60870-5-101 ANSI X3.28 - AB (ABB) RP570 RP570 DNP 3.00 CPI /Slave Slave Slave Slave and Slave Microsoft is a registered trademark of Microsoft Corporation. Windows and Windows NT are trademarks of Microsoft Corporation. Intel and Pentium are registered trademarks of Intel Corporation. Echelon, LON, LonTalk and Neuron are registered trademarks of Echelon Corporation. LONWORKS and LONMARK are trademarks of Echelon Corporation. All other product names are trademarks, registered trademarks, or service marks of their respective owners. 4

ABB Oy Distribution Automation P.O. Box 699 FI-65101 Vaasa, FINLAND Tel +358 10 22 11 Fax +358 10 224 1094 www.abb.com/substationautomation