SmartSwarm 341 Quick Start Guide

Similar documents
SmartSwarm 351 Quick Start Guide

MANAGED ETHERNET SWITCHES

MANAGED ETHERNET SWITCHES

WIRELESS SENSING PLATFORM FOR IoT. Intelligence at the

Expansion Port SWITCH USER MANUAL

Wireless. solutions. The Right Connection for. Make the Right Connection for Industrial Wireless Solutions

Expansion Port RS232 USER MANUAL

Expansion Port RS485/RS422 USER MANUAL

intelligent transportation systems superior solutions with smart technology

Expansion Port CNT USER MANUAL

EDGE router ER75i. Content of package : Modem ER75i Power supply Antenna Crossover UTP cable Installation CD with instruction and drivers

Expansion port ETH USER S GUIDE

Class I. The Right Connection for

General Product Line Card

Expansion Port RS485/RS422

Panoramic Power Installation and configuration guide

Expansion port WIFI OBSAH. USER S GUIDE

Wzzard Intelligent Sensing Platform. Design and Development Kit Guide

/ Expansion port MBUSD OBSAH USERS GUIDE

LTE Industrial Router ICR-1601 USER MANUAL

LTE Industrial Router. LR77 v2 Libratum USER MANUAL

GSM-R Router. RR75i v2 USER S MANUAL

Quick Start M!DGE / MG102 Wireless Router 6/13/2017

HSPA+ Industrial Router. UR5i v2 Libratum USER S MANUAL

LTE Industrial Router. LR77 v2 Libratum USER MANUAL

Quick Start M!DGE / MG102 Wireless Router 11/16/2011

+SMART CELLULAR ROUTERS & GATEWAYS

CAPABILITIES BROCHURE

CDMA Industrial Router. CR10 v2 USER S MANUAL

JT4100P LTE Outdoor CPE Administrator User Manual V1.0

Giga-MiniMc TX & RX USER MANUAL

Energy Monitoring Dashboard. User Manual

NetComm NTC-5000 CallDirect Series HSPA Cellular Routers Quick Start Guide

WRM 247+ QUICK GUIDE

Advantech IoT Sensing Devices Bringing Edge Intelligence to Big Data

+SMART CELLULAR ROUTERS & GATEWAYS

/

LTE Industrial Router. SmartStart SL304 USER MANUAL

Remote Pump Station Management Solution

Panoramic Power Installation and configuration guide

SysLINK 1000/1500 Family Quick Start Guide

Figure Error! No text of specified style in document.-1: M3-EXT-PM1

SysLINK 500 Family Quick Start Guide

Ethernet Interface Module

LTE Industrial Router. LR77 v2 USER MANUAL

Chapter1. Interface Introduction

AM4000D Outdoor CPE User Manual

NetComm Commercial. NetComm NTC-6000 CallDirect Series HSPA Cellular Routers Quick Start Guide

WebNMS IoT Cloud Gate Deployment Guide

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

Getting started with

CHAPTER 7 ADVANCED ADMINISTRATION PC

T1/E1 Channelized Gigabit Router

Industrial router XR5i USER S MANUAL.

Industrial router XR5i USER S MANUAL

Dome Camera. Hardware Manual Z81, Z /01/08

Cisco Universal Small Cell G Module

Moxa Remote Connect Gateway User s Manual

Cradlepoint ARC CBA850

Energy Monitoring Dashboard. User Manual

Installation and Configuration Quick Guide R2000. Industrial Dual SIM Cellular VPN Router (2 Eth + 2 SIM) Package Contents

Quick Start Guide. GV-Video Server

UR51 Industrial Cellular Router

I/O ETHERNET CONTROLLER ELAN1

LTE Industrial Router. SmartStart SL302 USER MANUAL

Quick Start Guide NTC-40 Series - M2M WiFi Router

Hardware manual. 1. Overview 2. Technical characteristics 3. Connections. ( Portal (../portal/portal.html)

PCAN-Gateway Quick Start Guide

WSDA User Guide

Wzzard Sensing Platform Network Planning and Installation. Application Note

Instructions Industrial 4G Router R700 - firmware version B Quick and easy setup of the Industrial 4G Router type R700

User Manual. AC ac Wireless Access Point/Router. Model WAC124. NETGEAR, Inc.

MGate 5111 Quick Installation Guide

M2M Router User Manual (Extract)

5.1 Configure each Sensor Pin Rename Set Rules Export Data Switching Nodes... 25

F5 WANJet 200. Quick Start Guide. Quick Start Overview

Quick Start Guide. W-118 Access Point. Arista Networks. DOC

UR72 & UR75 Industrial Cellular Router

GREENBOX EV. User Guide. Revision 1.3

Installing the Linksys app on your Android device via the Google Play Store and Google Play Website

FIBARO SINGLE SWITCH

The Cosy 131 User Guide USER MANUAL

Installation and Configuration Quick Guide

RAD XD and RAD XD-WM a/b/g Transceiver with Serial Link Quick Start Guide

Quick Start Guide. Version: 1.0. (For future update, please visit DrayTek web site) Date: Dec. 13, 2013

D-Link (Europe) Ltd. 4 th Floor Merit House Edgware Road London HA7 1DP U.K. Tel: Fax:

WRT4000 Series Cellular Wireless Routers

MGate 5118 Quick Installation Guide

Document Version: 1.0. LG308 LoRaWAN Gateway User Manual. LoRaWAN Gateway User Manual ---Update: / 30

Orbi Outdoor Satellite User Manual

Installation and Configuration Quick Guide. R3000 Lite. Industrial Dual SIM Cellular VPN Router (1 Eth + 1 RS RS USB Host)

Quick Start Guide Elinx ESW500 Series. Managed Din Rail Ethernet Switch

The StrideLinx Remote Access Solution comprises the StrideLinx router, web-based platform, and VPN client.

Quick Installation Guide

Quick Start Guide. GV-Video Server

IFS NS3552-8P-2S and NS3550-2T-8S Quick Installation Guide

Cradlepoint AER1600/AER1650

Installation and Configuration Quick Guide R3000. Industrial Dual SIM Cellular VPN Router 2 Eth + 1 RS RS USB Host.

ETM350C & ETM450C User Manual

wattch TOOLBOX-ETH-GPRS EWATTCH Toolbox User Guide CONNECTED SOLUTIONS FOR ENERGY CONTROL

Transcription:

SmartSwarm 341 Quick Start Guide 1. Introduction QUICK START GUIDE The SmartSwarm 341 IIoT gateway provides on-site management, aggregation, filtering and business logic for data recovered from a network of connected WZZARD wireless mesh nodes. It provides a Node-RED graphical user applications programming environment which can process data from multiple sources to produce a real-time data feed from the local asset into IIoT applications such as dashboarding, analytics or predictive maintenance, as well as providing local dashboarding and direct communications via email etc.! Safety Use the device in compliance with national and international law and in compliance with any special or additional restrictions regulating use of the Advantech B+B SmartWorx device in specific applications and environments. Use only the original accessories as provided by Advantech B+B SmartWorx. Using unapproved accessories can result in device damage, warranty termination, and/or violation of legal regulations. Unauthorized device or accessory modification can result in device damage, warranty termination, and/or violation of legal regulations. Do not open the device. When connecting the device to a power supply do not exceed the defined voltage. Do not expose the device to extreme ambient conditions. Protect the device against dust, moisture, and high temperature. We declare that the SmartSwarm 341 (except for versions SG300) is in compliance with the essential requirements and other relevant provisions of directive 1999/5/EC. SmartSwarm 341 versions SG300 are in compliance with the essential requirements and other relevant provisions of directive 2014/30/EU and 2014/35/EU. The Declaration of Conformity is available on the company website or from technical support, on request. Advantech B+B Smartworx, 2017 1

Product Disposal The WEEE (Waste Electrical and Electronic Equipment: 2002/96/EC) directive has been introduced to ensure that electrical/electronic products are recycled using the best available recovery techniques to minimize the impact on the environment. This product contains high quality materials and components which can be recycled. At the end of its life this product MUST NOT be mixed with other commercial waste for disposal. Check with the terms and conditions of your supplier for disposal information. 2. Connect Antennas Connect a 2.4GHz antenna to the connector marked WZZARD. If required, and if you have a cellular enabled version of the SmartSwarm 341, connect the main cellular antennas to the device by screwing them into the ANT and DIV connectors. 3. Install SIM Card If you intend to use this device to communicate over a cellular network, place an activated data-provisioned SIM card into the SIM1 card reader.! 2 NOTE: SIM2 is not currently supported.

4. Connect Power The device requires between +10 to +60 VDC power. 4W typical; 11 W peak. 5. Connect Ethernet An Ethernet cable may be connected to the ETH0, and/or ETH1, connectors on the front panel. By default, the Ethernet ports are configured as follows: PORT PURPOSE DEFAULT SETTING ETH0 ETH1 LAN port (default) Connect your laptop or PC to get a local web-server for device configuration and diagnostics. WAN port (default) Connect this port to your WAN to allow the device to obtain access to the remote device management service, SmartWorx Hub, over Ethernet. DHCP Server IP Address: 192.168.1.1 NetMask: 255.255.255.0 DHCP Client: The device will automatically obtain an IP address from your DHCP server. 6. Configuration By default, the device will make a secure connection to the cloud-hosted device management service: SmartWorx Hub. https://hub.bb-smartworx.com This will automatically happen if there is an outbound WAN connection available via ETH1, with a route to the public Internet. ALTERNATIVELY, you may want to use cellular. This requires a valid SIM card in SIM Slot 1. In order to configure the cellular connection, connect your laptop or PC directly into ETH0, then point your web browser at 192.168.1.1. You will be prompted to sign in: the default password is 5mart5warm. We recommend that you change this default password after you login for the first time. 3

Enter the APN name and optional credentials, as required by your SIM card provider / network operator. The WAN LED will turn ON (yellow) when the cellular connection has been successfully established. 4

6.1 Mesh with Wzzard Sensor Nodes By default, the mesh Network ID is set to 1981, and the Join Key is left blank. This corresponds to the default settings used in the WZZARD wireless sensor nodes: If everything is left in default configuration, then a new Wzzard node simply needs to be powered up in order for it to find and join the mesh network.! NOTE if multiple gateways are used in the same area, configured with the same Network ID and join key, then new Wzzard nodes will connect to the first gateway they find. If you have more than one Gateway, please ensure all your Gateways are using different Network IDs, and configure your WZZARD sensor nodes accordingly. Please refer to your WZZARD documentation for information on how to configure the WZZARD sensor nodes. 6.2 Node-RED The SmartSwarm 341 runs a Node-RED programming environment by default. In order to access this environment from your web-browser, you will need to open TCP port 1880 within the Node-RED containerised-application firewall. 5

Now, to access the Node-RED programming environment, point your browser at: 192.168.1.1:1880 Note that port 1880 has been opened on all interfaces. So you may alternatively access Node-RED via ETH1, using the WAN IP Address that has been assigned to ETH1. 6.3 Getting Data from Wzzard into Node-RED From the Node-RED Palette, select the wzzard input Node, and drag it onto the editor canvas. Double-click on it to configure it. By default, the Port will be 1883. Do not change this. In the Topic field, enter: BB/+/data, then click DONE. This will subscribe to all Data that is being published by all of the WZZARD sensor nodes that are available on the current WZZARD MESH network. 6

From the Node-RED Palette, select the debug output node, and drag it onto the editor canvas. Join up the wzzard node to the debug node. Deploy this Node-RED Flow. You should see that the wzzard node is now connected. Turn on Debug output. Now, you can verify that you are receiving Data from your WZZARD sensor nodes in the debug panel in the side-bar. 7

6.4 Push Config-Data to Wzzard from Node-RED It is possible to use the Node-RED environment to push configuration data out to the WZZARD sensor nodes.! If you choose to use this option, you will need to know the WZZARD Topic Space and Data Formats required. Please refer to your WZZARD documentation. For example: If you wish to change the Publish Interval of one of your WZZARD sensor nodes, select the inject input node, and the wzzard output node, and drag them both onto the Canvas. Edit the inject node: select JSON as the payload type and enter the string { pi :30 } to configure a 30 second Publish Interval. Enter BB/WZZARD_BTLE_ID/set/sys into the Topic field: Replace the text WZZARD_ BTLE_ID with the actual 12 character BTLE ID of the WZZARD sensor node you want to set. 8

Edit the wzzard output node. Confirm port 1883, and Update. Deploy this Flow. Now, when you push the inject input button on the inject node in the flow, the Publish Interval for your WZZARD sensor node will be changed to 30 seconds. You can confirm, using the debug output node, as before. 6.5 Getting Data from ADAM/WISE into Node-RED SmartSwarm 341 can interact with ADAM 6000 and WISE 4000 series I/O modules using their REST interface. As an example, the following describes how to set up simple interaction with a WISE 4000 series device. NOTE that the command structure for ADAM differs to that for WISE, and the URL and payload details below will not work with an ADAM device. Refer to the WISE/ADAM manual for a full description of the available command methods and data formats. 9

From the Node-RED pallete, drag down an inject node and http request node and link them together. The inject node should be configured to repeat at the interval you wish to recover data. The Payload content is not important as it is just providing a trigger. The http request node should be configured for a GET method, and the URL should be set to the IP address and REST query needed to extract the relevent data. For example: 192.168.100.104/ai_value/slot_0/ recovers all AI data from a unit at 192.168.100.104 192.168.100.104/ai_value/slot_0/ch_0 recovers just AI 0 data 192.168.100.104/di_value/slot_0/ recovers all DI data from a unit at 192.168.100.104 192.168.100.104/di_value/slot_0/ch_0 recovers just DI 0 data Basic authentication should be selected with username = root and Password = 00000000 to match the defaults for the ADAM/WISE unit. 7. Remote Configuration Using SmartWorx Hub The USR LED will turn on (yellow) when the device successfully makes a secure connection with SmartWorx Hub (https://hub.bb-smartworx.com). The SmartSwarm 341 can be configured remotely via the SmartWorx Hub cloud-hosted device management service. To access this service, go to: https://hub.bb-smartworx.com If this is your first time accessing this service, you will need a SmartWorx Hub account. Contact your device supplier to arrange this. If you have an account, please login to claim and manage your devices. 10

In order to verify the installation, please check that the device is shown as line in SmartWorx Hub: 8. Factory Defaults The unit may be reset to Factory Defaults at any time by pressing the Reset button on the back-panel of the device for more than 10 seconds. 9. Additional Documents The User Manual for the SmartSwarm 341 can be found on the company web site: http://advantech-bb.com/product-technology/iot-and-network-edge-platforms/ smartswarm 11

10. LEDs LED COLOR STATE DESCRIPTION PWR USR Green Yellow No power Device is booting Blinking Device is in normal operating mode Fast Blinking Device is updating firmware. Do not power off The device does not have a working session established with SmartWorx Hub The device has a working secure session established with SmartWorx Hub PoE n/a n/a Not Used Wzzard Status DAT SIM WAN IN0 IN1 Out ETH0 ETH1 ETH0 ETH1 Yellow Red Green Yellow Green Green Yellow Green Yellow Blinking Blinking Blinking The Wzzard App on the Gateway is either not installed or not running. The Wzzard App is installed and running. There is communication in progress on the DUST mesh network There is no communication on the cellular interface at this moment There is communication in progress on the cellular interface Reset button pressed or the device is booting Ready for operation. SIM 1 is enabled There is no cellular connection between the Gateway and the cellular service provider A cellular connection has been successfully established between the Gateway and the cellular service provider A cellular connection has been successfully established between the Gateway and the cellular service provider The default state Binary input no. 0 is active (user defined) Binary input no. 1 is active (user defined) The default state Binary output is active (user defined) 10 Mb/s 100 Mb/s The network cable is not connected Network cable is connected Data transmission in progress Worldwide Headquarters ADVANTECH No.1, Alley20, Lane26, Rueiguang Road Neihu District, Taipei 11491 Taiwan, R.O.C Phone: 0800-777-111 www.advantech.com European Headquarters Oranmore, Co. Galway, Ireland Phone: +353 91 792444 Fax: +353 91 792445 esales@advantech-bb.com Corporate Headquarters 707 Dayton Road Ottawa, IL 61350 USA Phone: 1-815-433-5100 Fax: 1-815-433-5109 orders@advantech-bb.com www.advantech-bb.com Middle East, UAE, Africa AG Silver Tower, JLT, P.O. Box 48777 Dubai, UAE Mobile: +971 50 943 65 62 mdeast-afrsales@advantech-bb.com Czech Republic Product Group Sokolská 71 562 04 Ústí nad Orlicí, Czech Republic Phone: +420 465 521 020 Fax: +420 464 647 299 cellularsales@advantech-bb.com Latin America, Carribean Phone: 1-727-797-0300 Cell: 1-727-480-5920 latamsales@advantech-bb.com OEM & Product Modification Phone: 815-433-5222 Fax: 815-433-5104 Attn: Custom Dept. custom@advantech-bb.com Custom Quote Request Form: www.advantech-bb.com/custom