Transceiver Hub with Integral Camera Power

Similar documents
Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Isolated Camera Power

Passive UTP Transceiver Hub Installation Guide

Rack Mount Power Supplies

AL168 Series Multi-Output Power Supplies

PoE Managed Midspan Solution for Standard Network Infrastructure

DC Outdoor Power Supply/Chargers

OWNER S MANUAL SINGLE CAT5E/6 3D EXTENDER B-320-1CAT-HDIR

OWNER S MANUAL SINGLE CAT5E/6 3D EXTENDER B-200-1CAT-HDIR. Receiver

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

1 Overview. 2 Specifications. Product Installation Document

Installation and Operation Manual CX452 with CHM22/CXM22

CLFE(X)UTP INSTALLATION AND OPERATION MANUAL

CLFE(X)COAX INSTALLATION AND OPERATION MANUAL

E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation and Operation Manual

TVA2.1 2-Channel Digital Amplifier Installation Manual

HDBaseT EXTENDER B-520-TX-230-IR B-520-TX-330-IR INSTALLATION MANUAL

Installation Instructions CX254 Card Cage Power Injector

4K HDR HDBaseT Extender B-560-EXT INSTALLATION MANUAL

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

5 B&W Rear View System Camera

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

U-150 Integrated Amplifier User s guide

Cantata m100 Amplifier

OWNER S MANUAL CD-2 V 1.3

Monochrome Camera. Features. User manual

OWNER S MANUAL GEQ 131/ 131LF GEQ 215/ 215LF GEQ 231. Single Channel 31 Band Graphic Equalizer. 2 Channel 15 Band Graphic Equalizer

MPF-1, Mains Power Filter User Manual

Installation Manual. 12 Volt Power Supplies. 18-Port. 9-Port RET18PT RET9PT

HDBaseT EXTENDER B-520-EXT-230-RS-W INSTALLATION MANUAL

INSTALLATION MANUAL. HDMI 1x4 Splitter B-230-HDSPLTR-1x4. B-230-HDSPLTR-1x4 HDMI OUT 4 HDMI OUT 3 HDMI OUT 2 HDMI OUT 1 HDMI OUT 4 HDMI IN

INSTALLATION MANUAL. HDMI 1x8 Splitter B-230-HDSPLTR-1x8 B-230-HDSPLTR-1X8

PS8 - II. Professional Power Sequencer. User s Manual

Installation Guide. Rev

VE8012A/VE8012AR DUAL NETWORKED STATION PORT

AVR Manual. Isolate. Restore. Inspire! Audio / Video Power Isolation Units with Automatic Voltage Regulation. 19 Pro Series Rack Mount (RM) Faceplate

Roth BAR 2LX High-Power Soundbar with Wireless Subwoofer. Turn it up. Roth BAR2 LX Manual UK VJ.indd 1 19/06/ :07

Neets Switching Relay - 2. Installation manual

OWNER S MANUAL >> BINARY HD MATRIX SWITCHER B-100-HDMATRIX-4X4 / B-100-HDMATRIX-8X8

Expandable Power Systems

Accessory Packages for the Allegiant

iconverter 2-Module Power Chassis

Quick Start Guide. C-100 Series Switches

Kogan Bluetooth Karaoke System with Dual Microphones KAKAR2MICA

HDMI 1x2 Splitter B-230-HDSPLTR-1x2 INSTALLATION MANUAL HDMI OUT 2 HDMI OUT 1 B-230-HDSPLTR-1X2 POWER HDMI IN

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

DLHD2100 Owners Manual

Isobar 12-Outlet Network Server Surge Protector, 15 ft. Cord, 3840 Joules, Diagnostic LEDs, 1U Rack-Mount, Metal Housing

DMX Tool Splitter 1 to 5 User Manual

WIRELESS BLUETOOTH BOOMBOX

ITEM NO: SP-001, SP-001P, SP-001VP, SP-001VPD, SP-002, SP-002VP, SP-002VPD, SP-003, SP-004, SP-004VPD, SP-005, SP-006, SP-016C, SP-016T

USB CASSETTE PLAYER MODEL NO. : GE USER MANUAL -

Quick Guide. ENC-H Video Encoder XX

Installation/ Operation Manual

DVAA Series Disk Array for DVR1 Series Digital Video Recorder

Monochrome Cameras LTC 0140 LTC 0142 LTC Eng. Philips Communication & Security Systems

FC-29W 9 UN-UNIVERSAL Dome Housing. Installation Instructions

Model 160. Model 186. Model 247. Surge Protective Devices. Installation & Operation Manual. Model 160. Model 186. Model 247 (EDCO RM-CX06-16R)

ebridge200b - Managed Two Port Transceiver Board

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

VMI. Technical Documentation. 600 Industrial Drive, New Bern, N.C (tel / fax /

SOUNDSTICKS WIRELESS. Setup Guide. Downloaded from

HMXAT200 Series System Controller

MP SERIES PROFESSIONAL POWER AMPLIFIER

MODEL GE4138 DIGITAL CD/MP3/USB/SD ENCODING WITH PLL AM/FM ALARM CLOCK STEREO RADIO - USER MANUAL -

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN

BCM2 Series Branch Circuit Monitors Quick Setup Guide

Digital Color Cameras

Passive CCTV Hub Plus (500134) Installation Guide

PS-20. Power Supply. User Manual Rev F

Roth BAR 2LX High-Power Soundbar with Wireless Subwoofer. Turn it up.

SUBWOOFER SYSTEM YST-MSW10

Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11

Surge Protection for Surveillance Systems

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

Installing the Cisco 2524 and Cisco 2525 Routers

RS232 Control Box. Table of contents

C-300 Preamplifier User s guide

Industrial 1-Port Coax/UTP Long Reach PoE+ 4-Port. 10/100TX PoE Extender LRP-104CET. User s Manual

Installing and Configuring Rialto Analytic Appliances

HDMI MATRIX SWITCHER B-120-HDMATRIX-4x4/8x8 CONFIGURATION UTILITY MANUAL

OPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B

TS-VGA OWNERS MANUAL. TS-VGA_manual_en_v1

CPD SERIES OPERATING MANUAL AND USER GUIDE. Professional Power Amplifier.

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

Protect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11

THANK YOU! CR120H. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club!

+Cam Quick Start Guide

THANK YOU FOR CHOOSING ORANGE

Outdoor Housing PIH-5063/5064/5067 INSTRUCTION MANUAL

INSTRUCTION MANUAL. Security Camera. Indoor/Outdoor Color Camera w/ Night Vision. Version 1.0. now you can see. Model# VU5

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

SYSTEM CONTROLLER TB-CN2R1 (2 AXIS STANDARD) TB-CN3R1 (3 AXIS STANDARD) TB-CN3R1W (3 AXIS WEB) Instruction Manual. Rev 2.0 TB-CN2R1 (2 AXIS STANDARD)

On-Line CardioTheater Instruction Manual for Amplifier Models 800 and 1600 (wired)

Transcription:

Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubWay8CD HubWay16CD - UL Listed eight (8) Channel Passive UTP - UL Listed sixteen (16) Channel Passive UTP Transceiver Hub with Integral Transceiver Hub with Integral HubWay82CD HubWay162CD - UL Listed eight (8) Channel Passive UTP - UL Listed sixteen (16) Channel Passive UTP Transceiver Hub with Integral Transceiver Hub with Integral - Includes eight (8) UL Listed Accessory - Includes sixteen (16) UL Listed Accessory HubWayAv Balun/s HubWayAv Balun/s HubWay83CD HubWay163CD - UL Listed eight (8) Channel Passive UTP - UL Listed sixteen (16) Channel Passive UTP Transceiver Hub with Integral Transceiver Hub with Integral - Includes eight (8) UL Listed Accessory - Includes sixteen (16) UL Listed Accessory HubWayDv Balun/s HubWayDv Balun/s Rev. 032108 More than just power. TM

Overview: Altronix HubWay8CD/16CD Passive UTP Transceiver Hub w/integral transmits UTP video, RS422/RS485 data and power over a single CAT-5 or higher structured cable. Unit provides 8 or 16 camera channels in a space saving 1U EIA 19 rack mount chassis which may be rack, wall or shelf mounted. transmission range is up to 750 ft. max. per channel. Units are compatible with AC and/or DC fixed or PTZ cameras when utilizing Altronix HubWayAv, HubWayDv or HubWay Dvi Balun/s. In addition, the unit features individually selectable or PTC protected outputs with surge suppression. An optional HubSat4D Passive UTP Transceiver Hub with Integral can be used as an accessory module to transmit video from up to 4 cameras over a single CAT-5 or higher structured cable back to the HubWay8CD/16CD. In addition, the HubSat4D provides power to these cameras locally to eliminate the possibility of voltage drop associated with long cable runs. HubWay8CD/82CD/83CD Input: 115VAC 60Hz, 1.5 amp. : Eight (8) channels of video over twisted pair up to a distance of 750 ft. per channel. Eight (8) 75 ohm video outputs. : Unit provides up to 1 amp max. per channel not to exceed a total of 5 amp (150VA) maximum current. Agency Listings: UL Listed for Commercial CCTV Equipment (UL 2044). CUL Listed - CSA Standard C22.2 No.1-04, Audio, and Similar Equipment. : RS422/RS485 data inputs. : Individually selectable or power outputs with position. PTC protected outputs are rated @ 1 amp per channel. Surge suppression. Visual Indicators: AC input power indicator. Features: Additional Models: HubWay82CD HubWay8CD with eight (8) UL Listed Accessory HubWayAv Balun/s for s. HubWay83CD HubWay8CD with eight (8) UL Listed Accessory HubWayDv Balun/s for 12VDC s. HubWay Specifications: Common Specifications: HubWay16CD/162CD/163CD Input: 115VAC 60Hz, 3 amp. : Sixteen (16) channels of video over twisted pair up to a distance of 750 ft. per channel. Sixteen (16) 75 ohm video outputs. : Unit provides up to 1 amp max. per channel not to exceed a total of 10 amp (300VA) maximum current. Illuminated master power disconnect circuit breaker with manual reset. IEC 320-3-wire grounded line cord (detachable). Unit can be rack, wall or shelf mounted. 1U rack mount chassis for use in standard EIA 19 rack. Accessories: Balun/s: - HubWayAv - for use with cameras. - HubWayDv - for use with 12VDC cameras. - HubWayDvi - for use with non-isolated 12VDC cameras. Optional HubSat4D allows transmission of up to four (4) video signals over a single CAT-5 or higher structured cable. HubWay162CD HubWay16CD with sixteen (16) UL Listed Accessory HubWayAv Balun/s for s. HubWay163CD HubWay16CD with sixteen (16) UL Listed Accessory HubWayDv Balun/s for 12VDC s. WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to all local codes. - 2 - HubWay Passive Unit

Installation Instructions: 1. Attach mounting brackets to HubWay unit for rack or wall mount installation (Figs. 6-7, pg. 8). Affix rubber pads to HubWay for shelf installation (Fig. 8, pg. 8). 2. Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least 3 from any video monitors). 3. Set illuminated master power disconnect circuit breaker to the () position (Fig. 5, pg. 7). 4. Plug the grounded AC line cord (included) into the IEC 320 connector of the HubWay8CD/HubWay16CD unit (Fig. 1g, pg. 4). Insert the plug end of the line cord into a grounded AC receptacle. 5. Set voltage output selector switch of each camera channel for or (Fig. 1d, pg. 4). 6. Connect the BNC video outputs for HubWay8CD/16CD Channels 1-8 (Channels 1-16) to the corresponding video inputs on the head end equipment (DVR) (Fig. 1f, pg. 4). 7. Connect the RS422/RS485 output of the head end equipment (DVR) to the one (1) or both data input terminal blocks of the HubWay8CD or HubWay16CD unit (polarity must be observed) (Fig. 1e, pg. 4). Note: The input terminals of the HubWay8CD or HubWay16CD must be wired in parallel for proper operation. When using fixed cameras disregard this step. 8. Connect Balun/ at camera 1 to the HubWay8CD or HubWay16CD unit utilizing CAT-5 or higher structured cable. Plug the RJ45 connector at one end of the structured cable into the RJ45 jack marked [Channel 1] of the HubWay8CD/16CD (Fig. 1a, pg. 4). Plug the RJ45 connector at the opposite end of the structured cable into the RJ45 jack of the Balun/ located at camera 1. For cameras use Altronix model HubWayAv Balun/ (Figs. 2a, 2b, pg. 5). For 12VDC cameras use Altronix model HubWayDv Balun/ (Figs. 2c, 2d, pg. 5). For non-isolated 12VDC cameras use Altronix model HubWayDvi Balun/ (Figs. 2c, 2d, pg. 5). Repeat steps 6-9 for each additional camera (Channels 2-8 or Channels 2-16). Note: When a particular camera exceeds the maximum distance for power transmission, a local external power source is required. Optionally, an Altronix HubSat4D Passive UTP Transceiver Hub with Integral may be utilized (Fig. 4a, pg. 6). The combined total cable distance must not exceed 750 ft. for video transmission between the HubWay8/16 and each camera routed through the HubSat4D. 9. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5, pg. 7) and measure the output voltage at the power output of each Balun/ (Figs. 2b, 2d, pg. 5) before powering each camera to insure proper operation and avoid possible damage. HubWayAv - Terminals marked [AC POWER] (Figs. 2a, 2b, pg. 5). HubWayDv/HubWayDvi - Terminals marked [ 12VDC +] (Figs. 2c, 2d, pg. 5). 10. Set illuminated master power disconnect circuit breaker to the () position to make the final connections (Fig. 5, pg. 7). 11. Connect the power outputs of the HubWayAv, HubWayDv or HubWayDvi Balun/s to the power inputs of the cameras (Figs. 2a-2d, pg. 5). Polarity must be observed. 12. Connect the terminals marked [+ DATA --] of the HubWayAv or HubWayDv Balun/s to the data terminals of the cameras for PTZ control (Figs. 2a-2d, pg. 5). Polarity must be observed. When using fixed cameras disregard this step. 13. Connect the BNC connectors of the HubWayAv, HubWayDv or HubWayDvi Balun/s to the BNC video outputs of the cameras (Figs. 2a-2d, pg. 5). 14. Upon completion of wiring set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5, pg. 7). 15. The power LEDs (Red) located on the front of the HubWay8CD/16CD will illuminate when AC power is present (Fig. 1c, pg. 4). Note: If any of these LEDs are not illuminated either a voltage output selector switch is in the position or the PTC is tripped for that channel. To reset the PTC: 1. Set the voltage output selector switch for that corresponding channel to the position. Switch must remain in the position for approximately 2 minutes in order for the PTC to reset. 2. Eliminate the trouble condition (short circuit or overload). 3. Set the voltage output selector switch for or (Fig. 1d, pg. 4). 16. AC LEDs (Green) of the HubWayAv or DC LEDs (Red) of the HubWayDv/HubWayDvi Balun/s will illuminate indicating power is present at the cameras (Fig. 2b, 2d, pg. 5). HubWay Passiive Unit - 3 -

Fig. 1 1e - : Removable terminal blocks for RS422/ RS485 input from head end 1b - Channels 1-4, Channels 5-8, Channels 9-12 & Channels 13-16: equipment (DVR) for PTZ control. CAT-5 or higher structured cable from optional HubSat4D enables video transmission from up to four (4) cameras. Top View input from Head End Equipment (DVR). + -- 1d - Output voltage switches: Selects // for each output. 1c - LED(s) 1-16: indicators. 1a - Channels 1-8 (HubWay8CD) or Channels 1-16 (HubWay16CD): CAT-5 or higher structured cable to /Balun s at cameras 1-8 or 1-16. When using an optional HubSat4D any of the outputs can be utilized for the data transmission to PTZ s. Front RESET 13 14 15 16 CH 13-16 1 2 3 4 CH 1-4 5 6 7 8 CH 5-8 9 10 11 12 CH 9-12 + DATA - 9-16 + DATA - 1-8 Rear 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 AC POWER 1g - IEC 320 Connector: 115VAC 60Hz (grounded line cord included). 1f - BNC Connector: outputs to head end equipment (DVR). - 4 - HubWay Passive Unit

Altronix Model Number Fig. 2 HubWayAv, HubWayDv and HubWayDvi Balun/s: Input Voltage from HubWay unit Output Voltage to camera Type HubWayAv */ */ cameras Green HubWayDv */ 12VDC 12VDC cameras Red HubWayDvi */ 12VDC electronically isolated 12VDC cameras without isolation Red *Based on camera load and structured cable length. LED Fig. 2a VIDEO HubWayAv VIDEO BALUN/COMBINER CAT5 AC + DATA-- POWER Fig. 2c VIDEO HubWayDv VIDEO BALUN/COMBINER CAT5 + DATA-- -- 12VDC+ * Also Available as: HubWayDvi Balun/ for non-isolated 12VDC cameras RJ45 Jack Wire Connectors RJ45 Jack Wire Connectors Fig. 2b Fig. 2d To BNC Connector of Structured Cable from HubWay8CD or HubWay16CD Green LED AC to -- to + To BNC Connector of Structured Cable from HubWay8CD or HubWay16CD Red LED + 12VDC -- to -- to + HubWayAv passes AC voltage from pins 4, 5, 7, 8 to terminals marked [AC ] (Fig. 3, pg. 5). HubWayDv/HubWayDvi converts AC voltage to DC voltage from pins 4, 5, 7, 8 to terminals marked [-- 12VDC +] (Fig. 3, pg. 5). Fig. 3 - CAT-5 Structured Cable Wiring Color Codes and PIN Configurations 1 - White/Orange [VIDEO +] 2 - Orange [VIDEO -- ] 3 - White/Green [DATA +] 4 - Blue [AC 1] 5 - White/Blue [AC 2] 6 - Green [DATA -- ] 7 - White/Brown [AC 2] 8 - Brown [AC 1] HubWay Passiive Unit - 5 -

Typical Applications: Fig. 4 Head End Equipment (DVR) RS485 Monitor Rear 8 7 6 5 4 3 2 1 AC POWER 1 2 3 4 CH 1-4 5 6 7 8 CH 5-8 + DATA - 1-8 Front CAT-5 CAT-5 Four (4) signals on a single CAT-5 (CAT-5) CAT-5 Max. video 750 ft. Fixed HubWayAv Balun Fixed HubWayDv/Dvi Balun HubWayDv/Dvi PTZ Balun HubWayAv Balun PTZ PTZ HubWayAv Balun Outdoor PTZ Outdoor NEMA Rated Supply HubWayAv or HubWayDv/Dvi Balun Fixed CAT-5 HubWayDv/Dvi Balun / Provided by HubSat4D 115VAC Input, 50/60Hz Fig. 4a - Optional hookup utilizing HubSat4D. (Coax) Fixed 115VAC Input, 50/60Hz - 6 - HubWay Passive Unit

1U EIA 19 Rack Mount Chassis Mechanical Drawing & Dimensions: 1.625 H x 19.125 W x 8.5 D REAR 1.625" 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 AC POWER TOP & BOTTOM 17.625" 8.5" FRONT 1 2 3 4 CH 1-4 CH 5-8 5 6 7 8 9 10 11 12 CH 9-12 13 14 15 16 CH 13-16 + DATA -- 1-8 + DATA -- 9-16 19.125".75" (ON) Fig. 5 Illuminated master power disconnect circuit breaker: position Circuit breaker tripped Switch not illuminated. RESET (ON) position Switch illuminated. The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the products enclosure that may be of sufficient magnitude to constitute an electric shock. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel. HubWay Passiive Unit - 7 -

Mounting Options: Rack Mount Installation 1- Remove and discard factory installed screws from both sides of rack chassis (Fig. 6a). 2- Install mounting brackets (A) on the left and right side of rack chassis using the four (4) flat head screws (B) (included) (Fig. 6b). 3- Place unit into desired EIA 19 rack position and secure with mounting screws (not included) (Fig. 6c). Fig. 6 Fig. 6a Fig. 6b Fig. 6c Top Top Top Front Left B Front Left Front Left Remove A Wall Mount Installation 1- Install mounting brackets (A) on the left and right side of rack chassis using four (4) flat head screws (B) (included) (Fig. 7a). 2- Place unit at desired location and secure with mounting screws (not included) (Fig. 7b). Fig. 7 Caution: It is necessary to Fig. 7a Fig. 7b make sure mounting screws are securely fastened to a beam when installing the unit vertically. B A Dotted lines indicate studs behind sheetrock. Shelf Installation 1- Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 8). 2- Place unit in desired location. Fig. 8 Altronix is not responsible for any typographical errors. C Left Side Rubber Pad Mounting Hardware (Included): A B C Two (2) mounting brackets Six (6) flat head screws for mounting brackets. Four (4) rubber pads. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 website: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A. IIHubWay8CD/HubWay16CD A14I MEMBER - 8 - HubWay Passive Unit