MODEL: GR8-EM. Communication Adaptor GR8 Series

Similar documents
MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R2K-1 SEN TRONIC AG. R2K Series

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

MODEL: R1M-GH. PC Recorders R1M Series

MODEL: WL40EW2F. Wireless I/O WL40F Series

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

MODEL: DL8. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.) Web Data Logger DL8

R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White.

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)

MODEL: IT40SW2. Tower Light Series. [2] LAMP 1 COLOR (1st layer from the top) R: Red Y: Amber G: Green B: Blue W: White

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: M2EXM. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: 47LYV. Digital Panel Meters 47 Series

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

MODEL: 43AL1. Digital Panel Meters 43 Series

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

PWR. Power Module Slots

MODEL: MD7TC. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable)

DAL4 REPEATER MODEL. (SIN-NET, M-Bus use) MODEL & SUFFIX CODE SELECTION DAL4 TRANSMISSION ORDERING INFORMATION RELATED PRODUCTS GENERAL SPECIFICATIONS

MIC-2 MKII, Multi-instrument DATA SHEET

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

MED102A. Industrial Serial to Single-mode Fiber Converter

R3-GE1 BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP)

MODEL: 40DN. Digital Panel Meters 40 Series

Communication Controller CC-Link/CPL Converter CMC10A

R1M-J3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL RTD & POTENTIOMETER INPUT MODULE MODEL. (8 points)

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Industrial 2-port RS422/485 Modbus Gateway

R6-NE1 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP, for 32-point analog signals)

Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1

Any device, including routers and hosts, is running an implementation of IP address Host

MODEL: R3-NL1. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

MODEL: 43DV2. Digital Panel Meters 43 Series

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

MODEL: R3-NL2. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

Network Instrumentation Modules NX Digital Output Modules NX-DY1/DY2

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Web-enabled DAQ System

NPN/PNP DISCRETE HIGH SPEED INPUT & NPN TRANSISTOR OUTPUT MODULE

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Energy Management BUS Adapter Type VMU-B 01

Power Serial Device Server

ProtoConvert Modbus RTU / Modbus TCP/IP / BACnet MSTP / BACnet IP / SNMP - Telnet (Lighting Controller) PG

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

Industrial 1-port RS422/485 Modbus Gateway

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

RS232C/RS485 Data can be easily monitored by LAN

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

ETHERNET/MFC 010 Technical Datasheet

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

MIC-2 Multi-instrument DATA SHEET

Designed for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections.

Stride Industrial Ethernet Switches

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

Warranty. Warning. Copyright. Contact Us

Energy Management BUS Adapter Type VMU-B

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

Mini Energy Web Server

RS-232 / RS-422 / RS-485 over Fast Ethernet Media Converter

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

WEB-ENABLED REMOTE TERMINAL UNIT Model: DL8 USERS MANUAL

tsh-700 Series User Manual

VMU-MC and VMU-OC. Pulse concentrator. Benefits. Description

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

Industrial Serial Device Server

ROCKETLINX ES8508 ES8508 ES8508F ES8508-XT ES8508F-XT QUICK INSTALLATION GUIDE

ZLAN5443A. User Manual

Manual and Protocol Description

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Momentum 171 CCC Processor with Ethernet Communication Port

Overview. Table of contents

Transcription:

Communication Adaptor GR8 Series Ethernet/RS-485 Adaptor (Modbus use) Functions & Features Bidirectional protocol converter for Modbus/TCP (Ethernet) and Modbus RTU (RS-485) Fast response time thanks to the Cache function Available the type designed to connect to DL8 and R8 series modules 2 (.0) 3 (2.8) 5 (4.53) mm (inch) MODEL: GR8 EM []-R ORDERING INFORMATION Code number: GR8 EM-[]-R Specify a code from below for []. (e.g. GR8-EM-D-R) [] INSTALLATION S: Single Use D: Coupled with DL8 * The internal bus of DL8 is not connected although coupled with DL8. Ethernet: RJ-45 connector Housing material: Flame-resistant resin (black) Isolation: Ethernet to RS-485 to power supply to FE DIP SW Setting: Selection of IP Address and Maintenance/Normal mode Configurator (IP Address and baud rate) Settings from Web browser (provided by user) Compatible terminal, browser Windows PC (Windows, 8.): Internet Explorer Firefox 3 Chrome 40 Smart Phone, Tablet PC (ios 8.3, Android 4.) Safari 8 Chrome 40 Status indicator LED: RUN, ERR, RD, SD, LINK, LK00 Modbus RTU Supported Commands Read Coil Status (0) Read Input Status (02) Read Holding Registers (03) Read Input Registers (04) Force Single Coil (05) Preset Single Register (0) Diagnostics (08) Fetch Comm. Event Counter () Fetch Comm. Event Log (2) Force Multiple Coils (5) Preset Multiple Registers () Report Slave ID () Cache Commands Following commands are valid for Cache function. Read Coil Status (0) Read Input Status (02) Read Holding Registers (03) Read Input Registers (04) (Up to 00 queries) POWER INPUT DC Power R: 24 V DC (Operational voltage range 24 V ±0 %, ripple 0 %p-p max.) GENERAL SPECIFICATIONS Connection Power input: Euro type connector terminal Applicable wire size: 0.2-2.5 mm 2 Stripped length: mm RS-485: Tension clamp (Front Twin connection) Applicable wire size: 0.2 -.5 mm 2 Stripped length: 0 mm GR8-EM SPECIFICATIONS ES-82 Rev. Page /

Ethernet, Modbus/TCP Standard: IEEE 802.3u Transmission type: 0BASE-T, 00BASE-TX Transmission speed: 0 / 00M bps (Auto Negotiation) Protocol: TCP/IP Number of connections: 8 Transmission media: 0BASE-T (STP cable; Category 5) 00BASE-TX (STP cable; Category 5e) Maximum segment length: 00 meters Communication configuration: with Web browser IP address: 92.8.0. (factory default setting) Subnet mask Default gateway Port No.: 502 (factory default setting) User name, password Modbus exception response Connection time out STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 000--4 EMS EN 000--2 RoHS Directive EN 5058 RS-485, Modbus-RTU Protocol: Modbus RTU Configuration: Bus type multi-drop Standard: Conforms to TIA/EIA-485-A Communication: Half-duplex, asynchronous, no procedure Transmission media: Shielded twisted-pair cable (CPEV-S 0.9 dia.) Communication configuration: with Web browser Baud rate: 2.4, 4.8, 9., 9.2, 38.4(*), 5., 5.2 kbps Parity bit: None, Odd(*), Even Stop bit: (*), 2 Read response timeout: 000 msec.(*), 0-0 000 msec. Write response timeout: 000 msec.(*), 0-0 000 msec. Cache function: Enabled(*), disabled Inter-frame interval: 0 msec.(*), 0-500 msec. (*)Factory default setting Terminating resistor: Built-in 0 Ω (DIP Switch, default: enabled) INSTALLATION Power consumption DC: Approx..5 W 24 V DC Operating temperature: -0 to +55 C (4 to 3 F) Operating humidity: 0 to 90 %RH (non-condensing) Mounting: DIN rail Weight: 20 g (0.2 lb) PERFORMANCE Insulation resistance: 00 MΩ with 500 V DC Dielectric strength: 500 V AC @ minute (Ethernet to RS- 485 to power to FE) GR8-EM SPECIFICATIONS ES-82 Rev. Page 2/

BASIC CONFIGURATIONS COUPLED WITH DL8 Make sure to install the unit coupled with DL8 at the end of all the other modules. With the unit installed between DL8 and I/O modules, I/O modules after the unit can not perform internal communication or the power can not be supplied to these I/O modules. Web-enabled Remote Terminal Unit Ethernet/RS-485 Adaptor I/O Modules DL8 GR8 EM Protective Cover HOW TO INSTALL Confirm that the locking clamps of the unit are set. Insert the unit straight in perpendicularly to the rail such that the grooves of the unit and the module on the immediate left engage each other. (A & B in the below figure) A B SINGLE USE HOW TO INSTALL A) Hang the upper hook at the rear side of unit on the DIN rail. Push in the lower in keeping pressing the unit to the DIN rail. B) To remove the unit, push down the DIN rail adaptor using a minus screwdriver. Pull out the lower part of the unit. Remove the upper part from the DIN rail. Note: When the unit is mounted on a DIN rail attached on the wall surface in vertical direction, use of an attachment plate to prevent the module from sliding down is recommended. GR8-EM SPECIFICATIONS ES-82 Rev. Page 3/

EXTERNAL VIEW FRONT VIEW Status Indicator LED RIGHT SIDE VIEW Function Setting DIP SW SW 2 3 4 5 8 ON Connector for RS-485 Communication RJ-45 Connector for Ethernet Terminating Resistor Setting SW Connector for Power Supply STATUS INDICATOR LED LED Color Light Module Status DIP SW SETTING IP Address SW- Mode Function OFF (*) Normal mode Set with configurator ON Factory default mode When starting up with the SW ON, the unit temporarily operates by the factory default settings of network configuration, user ID and password. The stored settings, however, are maintained and the unit returns to the original settings upon restarting at normal mode. When network settings are changed during factory default mode, the changed settings are stored. Maintenance mode SW-2 Mode Function OFF (*) Normal mode Normal operation ON Maintenance mode Stop output (Modbus function 05, 0, 5, are disabled) GR8-EM SPECIFICATIONS ES-82 Rev. Page 4/

TERMINATING RESISTOR SW Terminating resistor TERM INCORPORATED TERMINATING RESISTOR OFF Disabled ON (*) Enabled (*)Factory default setting RS-485 CONNECTOR TERMINAL ASSIGNMENT Unit side connector: MC,5/5-GF-3,5 Cable side connector: TFMC,5/5-STF-3,5 POWER SUPPLY TERMINAL ASSIGNMENT Unit side connector: MSTB2,5/3-G Cable side connector: MSTB2,5/3-ST 5 4 3 2 No. ID FUNCTION 5 FE FE 4 SH SHIELD 3 DG DG 2 DB DB DA DA 2 3 No. ID FUNCTION (+) Power supply 24V (+) 2 ( ) Power supply 24V ( ) 3 FE Power supply earth COMMUNICATION CABLE CONNECTIONS * Terminating Resistor GR8-EM DA DB DG SH FE RS-485 devices DA DB DG SLD FG * Turn the terminating resistor SW ON to use the incorporated terminating resistor. DIMENSIONS unit: mm (inch) COUPLED WITH DL8 SINGLE USE (.28) 3 (2.8) 3 (2.8) 24 (.94) 3 (.2) 55 (2.) [4 (.)] 24 (.94) 3 (.2) 55 (2.) [5 (.20)] (.28) (.28) (.24) (.24) 5 (4.53) 5 (4.53) (.24) GR8-EM SPECIFICATIONS ES-82 Rev. Page 5/

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM POWER + FE Power Circuit (non isolated) LED Control Ciruict FUNCTION SETTING SW Isolation Isolation RJ-45 CONNECTOR DA DB DG SH FE To other RS-485 devices SYSTEM CONFIGURATION EXAMPLES Devices other than the GR8-EM in below provided by the user. COUPLED WITH DL8 Hub DL8 Client I/O modules DL8 GR8-EM RS-485 24V DC power Note: It is not available to supply the power via DL8. Supply the power with the connector for power supply. Remote I/O modules GR8-EM SPECIFICATIONS ES-82 Rev. Page /

SINGLE USE PC Recorder (model: MSR28, MSR2K) Hub STP Cable STP Cable (0BASE-T, 00BASE-TX) Communication Adaptor (model: GR8-EM) Communication Adaptor (model: GR8-EM) RS-485 R3, R5, R, R Series RS-485 Interface Modules (model: R3-NM, R5-NM, R-NM, R-NM2) Remote I/O (RM etc.) Max 3 nodes Specifications are subject to change without notice. GR8-EM SPECIFICATIONS ES-82 Rev. Page /