Similar documents
Power Supply HARTING pcon

Operating instructions. Standstill monitor A / / 2011

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

Power Supply HARTING pcon

ABB component drive ACS50, 0.18 to 2.2 kw Technical catalogue PRODUCTS

QUINT-PS/ 1AC/24DC/ 5

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

QUINT-PS/24DC/48DC/ 5

AIAS. Technical description

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

Power supply module, bus connection module

Data sheet. Constant current DALI LED control gear 80 W Output power ma Output current Intelligent temperature protection.

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

Assembly and Operating Instructions Door Control

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Safety. Detection. Control. MAGNUS RFID ENG - REV

IF-80x Outdoor Terminal

Sensing light curtain as per DIN 18650/EN 16005

ASI QUINT /2.4 EFD

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

VariFlex 2 - RVEF Series

PHOENIX CONTACT Features

5 MICROMASTER 420 specifications

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

BMF400 Input/output module

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Modular PDU Smart metering for your IT

Sensing light curtain as per DIN 18650/EN 16005

Magnetically Actuated Safety Interlock Switches

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

QUINT-PS/ 1AC/24DC/20/CO

SafeC S. Features. Typical Applications. Technical Data. Principle. Safety Relay

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

A P P L I C A T I O N

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

TRIO-DIODE/12-24DC/2X10/1X20

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

VARIABLE SPEED DRIVES

Compact Coded Magnetic Safety Interlock Switch and Control Units

DIS-2 series Decentralised servo drive

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

AP 701 Access Panel. Features and Functions

DIS-2 series Decentralised servo drive

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

SNO 4003 K plus. Areas of application for the unit. Connection circuit diagrams. Intended use. Competent persons. Equipment and functional description

Power supply CP-D 12/2.1 Primary switch mode power supply

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

5 MICROMASTER 440 specifications

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Operating instructions. Switching amplifier DN0210 DN / / 2015

ML7421A,B Electric Linear Valve Actuators

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

ECS servo system MCS servo motors

SED2 Variable Frequency Drives

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

VARIABLE SPEED DRIVES

Power Supplies V7-T6-2 V7-T6-4 V7-T6-10 V7-T6-16 V7-T6-36 V7-T6-39 V7-T6-43

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

Datasheet - SRB 301LC/B-24V

System Overview Fuel/air ratio control system VMS. Sensors and systems for combustion engineering.

Operating instructions. Speed monitor D / / 2014

Operating Instructions

SSR - Supplies - Relays

SIMOREG 6RA70 DC MASTER SIMOREG CM

DOR6. Components All functions and indications are on the front of the module. Characteristics

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

CONFIGURABLE SAFETY RELAYS

KRAL Electronics BEM 300 and BEM 500.

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

STEP-PS/1AC/24DC/2.5. Extract from the online catalog. Order No.: DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase.

Rotary version, three-position control

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

Siemens Industrial s

Elo-1145-MSS-Zentraleinheit 471 M41 H31.book Page 1 Tuesday, September 6, :10 PM, Datum:

ABB Component Drives ACS55, 0.25 to 3 Hp

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

TEPI11 P/I signal converter

to 12a Added Standard and Electrical requirements for UL table 1.1

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Transponder card reader

Transcription:

STRICKER MODULAR DOOR CONTROL SMT 750 RELIABLE ELECTRONICS FOR STABLE OPERATION AND MAXIMUM EASE OF USE

RELIABLE ELECTRONICS AND MAXIMUM EASE OF USE OUR CONSULTANTS ARE AT YOUR SERVICE We are happy to answer all your questions about the Stricker Control SMT 750 and all other door system products. Feel free to contact our consultants. POSTAL CODE 1-5 AND BENELUX COUNTRIES POSTAL CODE 6-0 AND ABROAD The modern door system only fulfills its purpose 100 percent when it is based on an ingenious control system. To ensure that it best fits your individual requirements and at the same time functions exactly according to our own ideas, we have taken the matter into our own hands. The Stricker Control SMT 750 that we have developed for highspeed doors is far more stable than conventional solutions. It operates reliably, the range of functions is specially designed for door systems and the handling is easy and straightforward. The Stricker Control SMT 750 not only meets the highest standard requirements, but also conforms to all current legal directives. Our Stricker Control SMT 750 is suitable for use with new door systems, but can also be easily retrofitted to models from other manufacturers. Thomas Musekamp Northern Germany/Benelux Phone +49 251 3288-167 Fax +49 251 3288-267 t.musekamp@stricker-torsysteme.de Henning Suuck Northern Germany/Benelux Phone +49 251 3288-184 Fax +49 251 3288-284 h.suuck@stricker-torsysteme.de Ralf Mertens Southern Germany/Abroad Phone +49 251 3288-141 Fax +49 251 3288-241 r.mertens@stricker-torsysteme.de Florian Thier Southern Germany/Abroad Phone +49 251 3288-123 Fax +49 251 3288-223 f.thier@stricker-torsysteme.de For further information about our Stricker Control and all other products please visit www.stricker.ms/control

DESIGN OF THE CONTROL The SMT 750 is composed of a control power module (CPM) and an operating module (OM). The operating module of the SMT 750 may be integrated in the cover of the control power module, but is also available as a separate component, for example, for integration in the guide rail of the door. The control power module can be mounted to the drive using available optional adapters. If the control functions of the control should be available on both sides of a door, another operating module can be connected to the control power module without any problem using the CAN-bus system architecture of the SMT 750. SMT 750 BENEFITS Modular, stable and versatile ease of use and programming The modular door control of Stricker is designed for use with your motor-driven, industrially used door. The SMT 750 takes care of a number of important tasks. This includes the control of the drive and the brake as well as the communication with the position sensor and the associated position evaluation of the door. Furthermore, the SMT 750 monitors and evaluates all connected safety elements. high stability and functionality control unit and control panel can be installed in physically separated locations the control can be easily retrofitted to models of other manufacturers designed for use with dynamically operated section doors and other door systems Control power module with separate operating module mounted to the drive Control power module with integrated operating module In addition, the SMT 750 meets the requirements of many different users and thus functions as the central interface for the use of your door for the operator who operates the door daily and the technician, who carries out maintenance on a regular basis. also light grids, RFID systems etc. can be operated with the control all standard requirements and current legal guidelines are met or exceeded the operator module also serves as a traffic light for increased safety THE CONTROL POWER MODULE Function and performance logic of the SMT 750 are combined in the control power module. The connecting terminals are removable, colored-coded and labeled according to function for an easier connection of the components. To ensure better safety, separate areas for high and low voltage are provided.

THE OPERATING MODULE The control can be operated and programmed using the OPEN, STOP and CLOSE button. Three capacitive buttons ensure easy and straightforward operation. They work without a pressure point and react merely to the proximity of the finger. Thus, for example, constant putting on and taking off work gloves can be avoided. The expected feedback from actuating a button occurs via a yellow background illumination. The red and green keyboard illumination serves as a traffic light for increased safety. The display shows operating and error messages. Display STOP button OPEN button CLOSE button Supply voltage and external consumers CEE-coupling (blue) Supply feed lines (on site) 1~230 V AC ±15 %, 50 Hz to 60 Hz; fuse protection of 16 A, k-characteristic 2 outputs for external consumers 230 V External consumer 230 V Output voltage 230 V AC ±15 %, 50 Hz to 60 Hz; output current maximum 1 A; output power max. 230 W External consumer 24 V Motor, brakes and position sensor connections 2 outputs for external consumers 24 V Output voltage 24 V DC ±5 % (at 230 V nominal voltage); output current maximum 1 A; output power max. 50 W 1 connection for three-phase motors Motor connection Output power 0.75 kw (at 230 V nominal voltage); output current maximum 5 A, short-term overload to 15 A for max. 500 ms, 22 A for max. 150 ms and 25 A for max. 100 ms; duty cycle of the motor (continuous energisation) maximum 80 % FUNCTIONAL CHARACTERISTICS conforms to the new EU Machinery Directive (2006/42/EC) factory pre-configured, parameters can easily be adjusted via laptop or manually control unit with compact dimensions (20 cm height, 40 cm width and 10 cm depth) operating module IP 67 no emergency stop is needed anymore compliance with the ASR 1.7 TECHNICAL SPECIFICATIONS Environmental requirements Operation 0 50 c Functional reliability -20 70 c Storage -20 70 c Humidity 35 80 % rh, non-condensing Control power module Housing version Die-cast aluminum housing painted RAL 7001 Protection type IP54 160 x 360 x 90 mm without cable glands Dimensions (w x h x d) 195 x 360 x 90 mm including cable glands Weight approx. 5 kg Operating module Housing version Protection type Dimensions (w x h x d) Installation depth Weight Plastic housing ral 7016 with operating foil and encapsulated electronics IP67 75 x 126 x 26 mm 20 mm approx. 0.5 kg Break connection Position sensor connections Safety inputs Emergency open Security contact system Safety light grid Inputs and outputs Inputs Relay outputs 1 connection for work and fail-safe brakes Electronically integrated rectifier Nominal capacity of the brake 29 W / 32 W; output voltage 102/104 V DC ; output current 0.27 A / 0.28 A (at 104 V), maximum 1 A 1 rs485 interface for digital limit switches type A and type B Nominal output voltage 12 V DC ±5 % (at 230 V supply voltage); output current maximum 100 ma; output power max. 1.32 W 3 inputs with the function emergency open ; switching threshold high 16 V, low switching threshold 5 V; input current 50 ma 1 input with the function STOP/OPEN for opto-electronic safety strips Nominal input voltage 12 V; switching threshold high 10 V, low switching threshold 3 V; input current up to 20 ma; Frequency 1 khz; sampling frequency 5 khz 1 input with the function STOP/OPEN ; switching threshold high 16 V, low switching threshold 5 V; input current 15 ma ±5 ma; test input GND 6 programmable inputs for sensors with potential-free contact ; switching threshold high 16 V, low switching threshold 5 V; input current 15 ma ±5 ma 3 programmable relay outputs Switching voltage (AC) nominal 230 V, maximum 264.5 V; switching voltage (AC1) nominal 1 A, maximum 2 A; switching capacity (AC1) nominal 230 W, maximum 530 W Switching voltage (DC) nominal 24 V, maximum 25 V; switching voltage (DC1) nominal 1 A, maximum 2 A; switching capacity (DC1) nominal 24 W, maximum 50 W Conformity Machinery Directive 2006/42/EC EN ISO 13849 / EN 13241 / EN 12453 / EN 12445 / EN 12978 EMC Directive 2004/108/EC EN 60001-6-1 / EN 60001-6-2 / EN 60001-6-3 / EN 60001-6-4 Low Voltage Directive 2006/95/EC EN 60335-1 / EN 60335-2-103 RoHS II 2011/65/EU EN 50581 Approval Type examination

Stricker GmbH & Co. KG An der Kleimannbrücke 4 48157 Münster Phone: +49 251 3288-0 Fax: +49 251 3288-174 torsysteme@stricker.ms www.stricker.ms