HCP DICOM Net DICOM Conformance Statement

Similar documents
Philips Medical Systems DICOM Conformance Statement. EasyWeb 2.0. Document Number April 1999

Philips Medical Systems DICOM Conformance Statement. Inturis Suite R2.2

DICOM Conformance Statement Product Name HCP DICOM Net Version

DICOM Conformance Statement. EasyWeb 3.0. Document Number XZR January Copyright Philips Medical Systems Nederland B.V.

Philips Medical Systems DICOM Conformance Statement USIT 1.5

Philips Medical Systems DICOM Conformance Statement USIT 1.5 L3

Philips Medical Systems. Xcelera R1.1L1. Document Number XPR July 2003

Technical Publication. DICOM Conformance Statement. Patient Browser 2.1. Document Revision 2. April 13, Copyright BrainLAB AG

DAR Revision Date: July,

DCMburner version 3.3.0

Digital Lightbox 1.0

DICOM Conformance Statement. EasyGuide R2.1

AVIA (Dx MM) DICOM 3.0 Conformance Statement

No. MIIMS0009EA DICOM CONFORMANCE STATEMENT FOR MODEL TFS-3000 (MIIMS0009EA) TOSHIBA CORPORATION 2001 ALL RIGHTS RESERVED

STaR. DICOM Conformance Statement. September 2009 Version NO COPIES PERMITTED

StellarPACS DICOM Conformance Statement. Version 1.3, August 2008 SoftTeam Solutions

DxMM/DxWin DICOM 3.0 Conformance Statement. Document Reference (Référence du document) : 99/ Oct30/ABA/MM103/398B

DICOM Conformance Statement

DICOM Conformance Statement. EasyVision R4.2 DICOM Store, Query/Retrieve, Print, Media. Document Number

Technical Publications

Technical Publications

DICOM Conformance Statement for PenFetch

Punctual Dicom Workstation

ETIAM Nexus. DICOM Conformance Statement.

Technical Publications

Technical Publications

DxServer for Windows NT DICOM 3.0 Conformance Statement. Document Reference (Référence du document): 00/ Dec28/ABA/MM100/410A

Technical Publications

Philips Medical Systems DICOM Conformance Statement. CT Aura Release 1.3

Technical Publications

ASTERIS MDS. DICOM Conformance Statement. for. Asteris Modality Distribution System (MDS) Software. Last Document Update: July 22, 2008.

HEALTHCARE DICOM Conformance Statement

1 Introduction Scope and audience References Acronyms and abbreviations 3. 2 Implementation model... 4

OASIS V4.0 DICOM Conformance Statement Rev. 3

DICOM 3.0 Conformance Statement for PlatinumOne Systems

Technical Publications

CHILI CHILI PACS. Digital Radiology. DICOM Conformance Statement CHILI GmbH, Heidelberg

Technical Publications

Technical Publications

Technical Publications

Technical Publications

Technical Publications

TOSHIBA AMERICA MEDICAL SYSTEMS

Technical Publication. DICOM Conformance Statement. Trauma 3.0. Document Revision 2. October 5 th, 2010

DICOM Conformance Statement

Technical Publications

DBSWIN DICOM Conformance Statement. DBSWIN DD-DICOM Interface. DICOM Conformance Statement V2.1

Cover will be supplied by PMG MARCOM group.

Technical Publications

DICOM Conformance Statement

Kodak Point of Care CR systems. DICOM Conformance Statement

Conformance Statements for DICOM PaCentric Connect / Traveler

Hologic Physician s Viewer 5.0 DICOM Conformance Statement

Technical Publications

DICOM Conformance Statement. PCR R5.2 and EasyVision RAD R2.2. Document Number November 1996

DICOM Conformance Statement for Scanner Interface. Release 4.7.1

This document contains confidential information that is proprietary to SonoSite. Neither the document nor the information contained therein should be

Whole Body X-ray CT System Supria. DICOM Conformance Statement

WINRAD-32 Teleradiology System Conformance Claim

Philips Medical Systems. Intera Document Number April 2003

SCORE 3D Workstation DICOM CONFORMANCE STATEMENT

DICOM Conformance Statement

Technical Publications

Technical Publication. DICOM Conformance Statement. iplan 3.0. Document Revision 1. November 17, Copyright BrainLAB AG

XPLORE GESTION SCP WORKLIST CONFORMANCE STATEMENT

DICOM Conformance Statement. DSI Release 4.4. Document Number June Copyright Philips Medical Systems Nederland B.V.

Dx Server for Windows NT DICOM 3.0 Conformance Statement

Dx Server for Windows NT DICOM 3.0 Conformance Statement

DICOM Conformance Statement * /02* /02 MADE IN GERMANY

Technical Publications

Philips Medical Systems DICOM Conformance Statement

SIEMENS. DICOM Conformance Statement

Version 7 DICOM Conformance Statement. Document Version 3.02, June 2009

DICOM CONFORMANCE STATEMENT FOR DIAGNOSTIC ULTRASOUND SYSTEM MODEL SSA-640A V5.0

CONFORMANCE STATEMENT

DICOM Conformance Statement. CT AV Series Product Line. Document Number February 1997

XPACS DICOM 3.0 Conformance Statement Document Version October 2004

QAngio XA 7.0. DICOM Conformance Statement

1 CONFORMANCE STATEMENT OVERVIEW

Copyright FUJIFILM Corporation, Japan. August, th Edition 897N100760F

Technical Publications

Dx Server for Windows NT DICOM 3.0 Conformance Statement

Whole Body X-ray CT System Supria. DICOM Conformance Statement

SonoWin Picture Archiving System

QPC XSCAN32 DICOM 3.0 Conformance Statement Document Version October 2004

DICOM Conformance Statement VISIQ 1.0

MediPlus TM PACS&RIS Version 2.6

Technical Publications

Medical Imaging Consultants, Inc.

DICOM Conformance Statement

Carl Zeiss Surgical GmbH

Image Display DICOM Conformance Statement

No. MIIUS0015EA DICOM CONFORMANCE STATEMENT FOR DIAGNOSTIC ULTRASOUND SYSTEM APLIO MODEL SSA-770A TOSHIBA CORPORATION 2001 ALL RIGHTS RESERVED

Version 9 DICOM Conformance Statement. Version 3.05, September 2015

Carl Zeiss Surgical GmbH

DICOM 3.0 Conformance Statement

Image Display DICOM Conformance Statement EasyViz 7.2

Visbion Limited. Image Viewer 4.1 Dicom Conformance Statement DCS-IV-Iss1. Issue 1 21 March Commercial in Confidence

Technical Publications

Technical Publications

Transcription:

HCP DICOM Net DICOM Conformance Statement Version 4.00.00 32-bit version for Windows NT/2000/XP Copyright - 1997-2004 SoftLink International Pvt. Ltd. Microsoft, Windows NT, 2000,XP are trademarks of Microsoft Corporation All the trademarks used are properties of their respective owners. Warning : This computer program and its documentation is protected by copyright law and international treaties. Unauthorized reproduction or distribution of this program or documentation, or any portion of it, may result in severe civil and criminal penalties, and will be prosecuted to the maximum extent possible under the law.

Table of Contents 1 INTRODUCTION... 1-1 1.1 SCOPE AND FIELD OF APPLICATION... 1-1 1.2 INTENDED AUDIENCE... 1-1 1.3 CONTENTS AND STRUCTURE... 1-1 1.4 USED DEFINITIONS, TERMS AND ABBREVIATIONS... 1-1 1.5 REFERENCES... 1-1 1.6 IMPORTANT NOTE TO THE READER... 1-1 1.7 GENERAL ACRONYMS AND ABBREVIATIONS... 1-2 2 IMPLEMENTATION MODEL... 2-1 2.1 APPLICATION DATA FLOW DIAGRAM... 2-1 2.2 FUNCTIONAL DEFINITION OF APPLICATION ENTITIES... 2-1 2.2.1 Imaging Import Application Entity... 2-1 2.2.2 Imaging Export Application Entity... 2-2 2.2.3 Query Retrieval Application Entity... 2-2 2.2.4 Commitment Application Entity... 2-2 2.2.5 Media Application Entity... 2-2 2.3 SEQUENCING OF REAL WORLD ACTIVITIES... 2-2 3 AE SPECIFICATIONS... 3-1 3.1 ASSOCIATION ESTABLISHMENT POLICIES... 3-1 3.1.1 General... 3-1 3.1.2 Number of Associations...3-1 3.1.3 Asynchronous nature... 3-1 3.1.4 Implementation identifying information... 3-1 3.2 HCP DICOM NET IMAGING IMPORT AE... 3-1 3.2.1 AE Specifications... 3-1 3.2.2 Association Acceptance Policy... 3-2 3.3 HCP DICOM NET IMAGING EXPORT AE... 3-3 3.3.1 AE Specifications... 3-3 3.3.2 Association Initiation Policy... 3-3 3.4 HCP DICOM NET QUERY RETRIEVAL AE... 3-5 3.4.1 AE Specifications... 3-5 3.4.2 Association Acceptance Policy... 3-5 3.4.3 SOP Specific Conformance... 3-5 3.5 HCP DICOM NET AE MEDIA SPECIFICATIONS... 3-6 3.5.1 AE Specification: DICOM Recording... 3-6 3.5.2 AE Specification: DICOM Reading... 3-7 4 COMMUNICATION PROFS... 4-1 4.1 SUPPORTED COMMUNICATION STACKS... 4-1 4.2 TCP/IP STACK...4-1 4.3 API... 4-1 4.3.1 Physical Media Support... 4-1 5 EXTENSIONS/SPECIALIZATION/PRIVATIZATION... 5-1 6 CONFIGURATION... 6-1 6.1 AE TITLE / PRESENTATION ADDRESS MAPPING... 6-1 7 SUPPORT OF EXTENDED CHARACTER SET... 7-1 HCP DICOM Net DICOM Conformance Statement i

Chapter 1 Introduction This chapter provides general information about the purpose, scope and contents of this Conformance Statement. 1.1 Scope and field of application The scope of this DICOM Conformance Statement is to facilitate data exchange between the HCP DICOM NET Server and medical equipment of other vendors. This document specifies the compliance to the DICOM standard (formally called the NEMA PS 3.X standards). It contains a short description of the applications involved and provides technical information about the data exchange capabilities of the equipment. The main elements describing these capabilities are: the supported DICOM Service Object Pair (SOP) Classes, Roles, Information Object Definitions (IOD) and Transfer Syntaxes. The field of application is the integration of the HCP DICOM NET Server into an environment of medical devices. This Conformance Statement should be read in conjunction with the DICOM standard and its addenda [DICOM]. 1.2 Intended Audience This Conformance Statement is intended for: (Potential) customers, System integrators of medical equipment, Marketing staff interested in system functionality, Software designers implementing DICOM interfaces. It is assumed that the reader is familiar with the DICOM standard. 1.3 Contents and structure The DICOM Conformance Statement is contained in chapter 2 through 7 and follows the contents and structuring requirements of DICOM PS 3.2. 1.4 Used definitions, terms and abbreviations DICOM definitions, terms and abbreviations are used throughout this Conformance Statement. For a description of these, see NEMA PS 3.3 and PS 3.4. The word SoftLink in this document refers to SoftLink International Pvt. Ltd. 1.5 References [DICOM] The Digital Imaging and Communications in Medicine (DICOM) standard: NEMA PS 3.X National Electrical Manufacturers Association (NEMA) Publication Sales 1300 N. 17th Street, Suite 1847 Rosslyn, Va. 22209, United States of America 1.6 Important note to the reader This Conformance Statement by itself does not guarantee successful interoperability of HCP DICOM NET Server with all HCP DICOM Net DICOM Conformance Statement 1-1

Introduction types of medical equipment from all vendors. The user (or user s agent) should be aware of the following issues: Interoperability Interoperability refers to the ability of application functions, distributed over two or more systems, to work successfully together. The integration of medical devices into a networked environment may require application functions that are not specified within the scope of DICOM. Consequently, using only the information provided by this Conformance Statement does not guarantee interoperability of HCP DCIOM NET Server with all types of medical equipment from all vendors. It is the user s responsibility to analyze thoroughly the application requirements and to specify a solution that integrates HCP DICOM NET Server with medical equipment from other vendors. Validation SoftLink equipment has been carefully tested to assure that the actual implementation of the DICOM interface corresponds with this Conformance Statement. When HCP DICOM NET equipment is linked to medical equipment from other vendors, the first step is to compare the relevant Conformance Statements. If the Conformance Statements indicate that successful information exchange should be possible, additional validation tests will be necessary to ensure the functionality, performance, accuracy and stability of image and image related data. It is the responsibility of the user (or user s agent) to specify the appropriate test suite and to carry out the additional validation tests. New versions of the DICOM Standard The DICOM Standard will evolve in future to meet the user s growing requirements and to incorporate new features and technologies. SoftLink plans to adapt its equipment to future versions of the DICOM Standard. In order to do so, SoftLink reserves the right to make changes to its products or to discontinue its delivery. The user should ensure that any other medical equipment provider linking to SoftLink equipment also adapts to future versions of the DICOM Standard. If not, the incorporation of DICOM enhancements into SoftLink equipment may lead to loss of connectivity (in case of networking) and incompatibility (in case of media). 1.7 General Acronyms and Abbreviations The following acronyms and abbreviations are used in the document. o ACC American College of Cardiology o AE Application Entity o ACR American College of Radiology o ANSI American National Standard Institute o BOT Basic Offset Table o CD-R CD Recordable o CD-M CD Medical o DCR Dynamic Cardio Review o DICOM Digital Imaging and Communication in Medicine o DIMSE DICOM Message Service Element o DIMSE-C DICOM Message Service Element-Composite o DIMSE-N DICOM Message Service Element-Normalized o ELE Explicit VR Little Endian o EBE Explicit VR Big Endian o FSC File Set Creator o GUI Graphic User Interface o HIS Hospital Information System HCP DICOM Net DICOM Conformance Statement 1-2

Introduction o HL7 Health Level Seven o Implicit VR Little Endian o IOD Information Object Definition o ISIS Information System - Imaging System o NEMA National Electrical Manufacturers Association o PDU Protocol Data Unit o RIS Radiology Information System o RWA Real World Activity o SC Secondary Capture o SCM Study Component Management o SCP Service Class Provider o SCU Service Class User o SOP Service Object Pair o TCP/IP Transmission Control Protocol/Internet protocol o UID Unique Identifier o WLM Worklist Management HCP DICOM Net DICOM Conformance Statement 1-3

Chapter 2 Implementation model This document is the DICOM Conformance statement for the SoftLink HCP DICOM NET V4.0. The HCP DICOM NET is primarily intended for archiving and viewing of X-Ray Angiographic multi-frame, SC, US multi-frame, US single-frame, CT, MR and CR images. Images from the local file system as well as CD media can be reviewed. All of the DICOM features presented in this document are optional and may not be available on different version of HCP DICOM NET. The HCP DICOM NET consists of a Server that handles the, Commitment and Query Retrieve of Images and a several Clients that can read and write media. 2.1 Application Data Flow Diagram The HCP DICOM NET related Implementation Model is shown in Figure1. Remote AE C-Store Request C-Store Response C-Find Request C-Find Response Remote AE Remote AE C-Store Request C-Store Response HCP DICOM Net C-Move Request C-Move Response Remote AE Figure 1: Application data flow diagram 2.2 Functional Definition of Application Entities 2.2.1 Imaging Import Application Entity A utility program called HCPDownloader accepts an association with a remote DICOM AE when the remote system requests image storage using the DICOM service class. Images are stored based on the study information of the Image. HCP DICOM Net DICOM Conformance Statement 2-1

Implementation Model 2.2.2 Imaging Export Application Entity A utility program called Modality Emulator can start an association with a remote DICOM AE and request image storage using the DICOM service class. Images are transferred based on the study information of the Image. 2.2.3 Query Retrieval Application Entity A utility program called HCPQR accepts an association with a remote DICOM AE when the remote system queries a Dicom study using the DICOM Query Retrieval service class. As a result of query processing HCPQR can transfer the resultant study to remote using the DICOM Query Retrieval service class. 2.2.4 Commitment Application Entity The HCP DICOM NET accepts an association with a remote DICOM AE when the remote system requests image Commitment. 2.2.5 Media Application Entity The Media AE in the HCP DICOM NET clients (viewers) supports the following functions; o Read the DICOMDIR file that represents the contents of the (image) data as recorded. This information is displayed as an ordered list of icon images together with pertinent identifying information (patient name, etc.). o Read the selected image from CD-R device and display it on the monitor of the View Station. This information is displayed as an ordered list of frames of the selected image or as a dynamic review of the selected image. o Initialization of the CD-R Media, writing a DICOM File-set onto the media. o Creation of images onto a Media. o Creation of a DICOMDIR file that represents the contents of the (image) data as recorded. 2.3 Sequencing of Real World Activities All Real-World Activities as specified in Figure 2.1 may occur independently from each other. HCP DICOM Net DICOM Conformance Statement 2-2

Chapter 3 AE Specifications The Network capabilities of the HCP DICOM NET consists of the following DICOM Application Entities: o An Imaging Import AE o An Imaging Export AE o A Query Retrieval AE 3.1 Association Establishment Policies 3.1.1 General The HCP DICOM NET always proposes the following DICOM Application Context Name (ACN): 008.3.1.1.1 The maximum length PDU negotiation is included in all association establishment requests. The default maximum length PDU for an association initiated by the HCP DICOM NET is: 16 KB. 3.1.2 Number of Associations The number of associations for the storage and Query Retrieve SCP service that may be active simultaneously is 4. 3.1.3 Asynchronous nature DICOM asynchronous mode is not supported meaning that only one transaction may be out-standing over an association at any given point in time. 3.1.4 Implementation identifying information The Implementation Class UID is: 1.3.46.670589.7.11.1.1 The implementation version name: HCPDICOMNET 3.2 HCP DICOM NET Imaging Import AE 3.2.1 AE Specifications The HCP DICOM NET Imaging Import Application Entity provides Standard Conformance to the DICOM V3.0 SOP classes as an SCP specified in Table 3.1. Table 3-1: Supported SOP Classes as SCP by Import AE and as SCU by Export AE SOP Class Name UID XA Image 008.5.1.4.1.1.1 2.1 SC Image 008.5.1.4.1.1.7 US multi-frame Image 008.5.1.4.1.1.3 US Image 008.5.1.4.1.1.6.1 CT Image 008.5.1.4.1.1.2 MR Image 008.5.1.4.1.1.4 CR image 008.5.1.4.1.1.1 NM image 008.5.1.4.1.1.5 HCP DICOM Net DICOM Conformance Statement 3-1

AE Specifications 3.2.2 Association Acceptance Policy 3.2.2.1 Associated Real World Activity The HCPDownloader is always ready to accept a new transport connection. The HCPDownloader will accept the presentation context associated with the Image request and reply with a C-STORE response when the complete image has been received on the established association. 3.2.2.2 Accepted Presentation Context The following table illustrates the Acceptable presentation contexts for the Image request. Table 3-2: Accepted Presentation Context by the Import AE Presentation Context Table Abstract Syntax Transfer Syntax Role Ext. Name UID Name List UID List Neg. SCP 008.5.1.4. 1.1.12.1 ELE X-RAY Angiographic Image Secondary Capture Image US multiframe Image 1.2.8s40.1 0008.5.1.4.1.1.7 008.5.1.4. 1.1.3.1 JPEG Baseline Coding Process 1 JPEG Lossless First-Order Prediction (Process 14) (Sel. Value 1) ELE ELE RLE.1.4. 50.4. 70.1.1 SCP SCP JPEG Baseline Coding Process 1 JPEG Lossless First-Order Prediction (Process 14) (Sel. Value 1).5.4. 50.4. 70 US Image 008.5.1.4. 1.1.6.1 ELE RLE.1 SCP JPEG Baseline Coding Process 1 JPEG.5.4. 50 HCP DICOM Net DICOM Conformance Statement 3-2

AE Specifications Lossless First-Order Prediction (Process 14) (Sel. Value 1).4. 70 CT Image MR Image CR Image NM Image 008.5.1.4. 1.1.2 008.5.1.4. 1.1.4 008.5.1.4. 1.1.1 008.5.1.4. 1.1.5 ELE ELE ELE ELE.1.1.1.1 SCP SCP SCP SCP SOP Specific Conformance The HCPDownloader cannot handle the import of images from different patients in one association. The HCP DICOM NET conforms to the SOP s of the Service Class at level 2 (full). No data elements are discarded or coerced by the HCP DICOM NET. Private Tags are not processed while converting the imported images for DICOM. The HCP DICOM NET can modify the following Attributes: Patient Name 0010,0010 Patient Sex 0010,0040 Patient Birthdate 0010,0030 Patient ID 0010,0020 Accession Number 0008,0050 C-Store Status Responses that are returned by the HCP DICOM NET Import AE are: FAILURE FAILURE SUCCESS A800 Illegal SOP Class A700 Out of Resource 0000 Success 3.3 HCP DICOM NET Imaging Export AE 3.3.1 AE Specifications The HCP DICOM NET Imaging Export Application Entity provides Standard Conformance to the DICOM V3.0 SOP classes as an SCU specified in Table 3.1. 3.3.2 Association Initiation Policy 3.3.2.1 Associated Real World Activity The Modality Emulator can make a new transport connection. The Modality Emulator can propose the presentation context in the association request for Image and expects a HCP DICOM Net DICOM Conformance Statement 3-3

AE Specifications C-STORE response when the complete image has been transferred on the established association. 3.3.2.2 Proposed Presentation Context The following table illustrates the possible presentation contexts for the Image request. Table 3-3: Proposed Presentation Context by the Export AE Presentation Context Table Abstract Syntax Transfer Syntax Role Ext. Name UID Name List UID List Neg. 1.2.840.1 SCU 0008.5.1. 4.1.1.12. 1 X-RAY Angiographi c Image Secondary Capture Image US multiframe Image 1.2.840.1 0008.5.1. 4.1.1.7 1.2.840.1 0008.5.1. 4.1.1.3.1 JPEG Baseline Coding Process 1 JPEG Lossless First-Order Prediction (Process 14) (Sel. Value 1).4. 50.4. 70 RLE JPEG Baseline Coding Process 1 JPEG Lossless First-Order Prediction (Process 14) (Sel. Value 1).5.4. 50.4. 70 SCU SCU US Image 1.2.840.1 0008.5.1. 4.1.1.6.1 RLE JPEG Baseline Coding Process 1 JPEG Lossless First-Order Prediction (Process 14) (Sel. Value 1).5.4. 50.4. 70 SCU CT Image MR Image CR Image 1.2.840.1 0008.5.1. 4.1.1.2 1.2.840.1 0008.5.1. 4.1.1.4 1.2.840.1 0008.5.1. 4.1.1.1 SCU SCU SCU HCP DICOM Net DICOM Conformance Statement 3-4

AE Specifications 3.4 HCP DICOM NET Query Retrieval AE 3.4.1 AE Specifications The HCP DICOM NET Query Retrieval Application Entity provides Standard Conformance to the DICOM V3.0 SOP classes as an SCP specified in Table 3.2. Table 3-4: Supported SOP Classes as SCP by the Query Retrieval AE SOP Class Name UID Patient Root Query/Retrieve 008.5.1.4. 1.2.1.1 Information Model FIND Patient Root Query/Retrieve 008.5.1.4. 1.2.1.2 Information Model MOVE 3.4.2 Association Acceptance Policy 3.4.2.1 Associated Real World Activity The HCPQR is always ready to accept a new transport connection. Remote AE can make a Query to HCPQR for a dicom study using C-FIND request on the established association to which HCPQR will respond with appropriate C-FIND response. Remote AE can retrieve a particular study by initiating C- MOVE request to HCPQR on an established association. As a part of handling this C-MOVE request HCPQR will start a new association with the Destination AE whose title was proposed in the C-MOVE request. HCPQR will act as a SCU for image storage and Destination AE will act as corresponding SCP for image storage. On completion of image transfer the respective association initiators will release both the associations. Destination AE should have been configured in HCP DICOM NET Server. 3.4.2.2 Accepted Presentation Context The following table illustrates the acceptable presentation contexts for the Image Query Retrieval request. Table 3-4: Proposed Presentation Context by the Query Retrieval AE Presentation Context Table Abstract Syntax Transfer Syntax Role Ext. Name UID Name List UID List Neg. Patient Root Query/Retriev e Information Model FIND 0 08.5.1.4. 1.2.1.1 ELE 008.1.2 008 SCP Patient Root Query/Retriev e Information Model MOVE 0 08.5.1.4. 1.2.1.2 ELE.1.2.1 008.1.2 008.1.2.1 SCP 3.4.3 SOP Specific Conformance 3.4.3.1 Patient Root Query/Retrieve Information Model - FIND Following table lists key attributes that can be part of C-FIND Request. Table 3-5: Attributes supported for Patient Root C-FIND HCP DICOM Net DICOM Conformance Statement 3-5

AE Specifications Query Level Attribute Tag Attribute Description PATIENT (0010,0010) Patient Name PATIENT (0010,0020) Patient ID STUDY (0008,0020) Study Date STUDY (0020,000D) StudyInstanceUID 3.4.3.2 Patient Root Query/Retrieve Information Model - MOVE Following table lists key attributes that can be part of C-Move Request. Table 3-5: Attributes supported for Patient Root C-MOVE Query Level Attribute Tag Attribute Description PATIENT (0010,0010) Patient Name PATIENT (0010,0020) Patient ID STUDY (0008,0020) Study Date STUDY (0020,000D) StudyInstanceUID 3.5 HCP DICOM NET AE Media Specifications The HCP DICOM NET AE provides Standard Conformance to the DICOM Media Service and File Format (PS 3.10) and the Media Application Profiles (PS 3.11). The supported Application Profiles, their Roles and the Service Class (SC) options, all defined in DICOM terminology, are listed in Table 3-20. Table 3-20: Supported Application Profiles Application Identifie Real World Role SC Option Profile r Activity Basic Cardiac X- RAY Angiographic Studies on CD-R media STD-XABC- CD STD-XABC- CD Write images(s) on CD-R disk Read image (s) from CD-R disk FSC FSR Interchange Interchange 3.5.1 AE Specification: DICOM Recording 3.5.1.1 Application Entity Title The Application Entity title is registered into the DICOM File Meta Information header and is supported by the CDwriter (CD write option) acting as a FSC. Application Entity Title: HCPDNPRO_FSU 3.5.1.2 RWA Transfer of an Examination The SOP instances as provided by the RWA are written to the CD-R media and a corresponding DICOMDIR is created. 3.5.1.3 Application Profile(s) for this RWA Refer to Table 3-20 for the list of Application Profiles that invoke this AE. 3.5.1.4 DICOMDIR Keys In the DICOMDIR file a Basic Directory IOD is present, containing Directory records at the patient, study, series and image level. HCP DICOM Net DICOM Conformance Statement 3-6

AE Specifications 3.5.2 AE Specification: DICOM Reading 3.5.2.1 Application Entity Title Not applicable. 3.5.2.2 RWA Review and Analysis of Examination The DICOM Reader AE will act as a FSR using the Interchange option when reading the directory of the medium and when reading the requested images. Reading images send to the HCP DICOM NET and viewed on the viewer will only be properly displayed for XA: 512*512, 512*1024, 1024*512 and 1024*1024 8 bits uncompressed or lossless JPEG. For SC: 512*512, 512*1024, 1024*512 and 1024*1024 8 bits and 1280*1024 8 bit (uncompressed). For US uncompressed as well as data encoded in RLE Lossless as weill as lossy JPEG is supported 3.5.2.3 Application Profile(s) for this RWA Refer to Table 3-20 for the list of Application Profiles that invoke this AE. HCP DICOM Net DICOM Conformance Statement 3-7

Chapter 4 Communication Profiles 4.1 Supported Communication Stacks TCP/IP is the only protocol stack supported. 4.2 TCP/IP Stack The TCP/IP stack as supported by the underlying Operating System. 4.3 API The API is the WinSock 2 interface as supported by the underlying Operating System. 4.3.1 Physical Media Support Supported physical medium include: o IEEE 802.3-1995 (Fast Ethernet) 100BASE-TX. o IEEE 802.3-1995 10BASE-TX HCP DICOM Net DICOM Conformance Statement 4-1

Chapter 5 Extensions/Specialization/ Privatization The viewer can write complete studies to one or more CDs depending on the study size. Further more one viewer can review and upload: o Multi CD study s HCP DICOM Net DICOM Conformance Statement 5-1

Chapter 6 Configuration 6.1 AE Title / Presentation Address mapping The Network and Media AE title as well as the IP Address and the TCP listen port associated with this AE are configurable. HCP DICOM Net DICOM Conformance Statement 6-1

Chapter 7 Support of Extended Character Set The HCP DICOM NET supports Extended Character Set ISO_IR 100 which is the Latin alphabet No 1, supplementary set. HCP DICOM Net DICOM Conformance Statement 7-1