Connect - Contact - Control. Connectors. SB Series Circular connectors for special applications Manual A30-M.en

Similar documents
Connnectors. B Series Connectors for rail vehicles Catalogue F160.en. More information here: schaltbau-gmbh.com

Connect - Contact - Control. Connectors according to UIC VE EP Series. F 121.en

Connect - Contact - Control. Multifunctional adapters for LV160 and LV320 Series charging connectors A 841.en

Connect - Contact - Control. Connectors. UIC Series Inter-car jumpers to UIC 558 VE Manual F120.en

Connect - Contact - Control. Connectors for rail vehicles Series B. 94x122. F 160.en

Installation manual plugs and connectors with screw connection (16/32 A)

Connectors. UIC Series Inter-car jumpers to UIC 558 VE Catalogue F120.en. More information at: schaltbau-gmbh.com

SolConeX Wall-Mounted Socket, 16 A

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

SolConeX extra-low voltage flange socket

HST -TZ1 Guard-locking mechanism (Translation of Original Manual)

Siemens Drives & PLCs

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Vibration Sensor Type 640

Universal Tristop Cylinder for Cam Brakes

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

HST -S1 Switching element (Translation of Original Manual)

3M Duplex Polishing Machine 6851-E with Universal Dual Holder Instructions

C9900-P208 and C9900-P209

Operation Manual. Capacitor Boxes adjustable 80 A / 125 A Track, 2,04 μf to 8 μf. Order Number

Operating Instructions

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

B63/ NS MS. EtherNet/IP LINK

icore Kiosk system Installation Guide

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

CONNECTOR AND RECEPTACLE WIRE/CABLE ASSEMBLY INSTRUCTIONS

Operating Manual -ENGLISH- Page 1 KWG-ISO

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

S200 Safety Switches SAFE IMPLEMENTATION AND OPERATION. Original operating instructions. make technical changes. We reserve the right to

HST -M2 Switching element with locking mechanism (Translation of Original Manual)

BK MIKRO. Air Barrier Adapter. Assembly Instructions Issue 1.00 dated

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Connect - Contact - Control. High Voltage Contactors. F 170e

Troubleshooting Manual

C9900-P223 and C9900-P224

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

HST -M1 Switching element with locking mechanism (Translation of Original Manual)

C-pan arm USERS INSTRUCTIONS

HST -TS1 Guard-locking mechanism (Translation of Original Manual)

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Electric Rotary Module RE-50 I RE-75 Declaration of Incorporation Module Information Montage Instructions Maintenance Instructions

User Manual 3D MANIPULATOR Accessory for UZ15 Rapid, UZ18 Hardworker and UZ12 Ultralight bevelling machines.

GRP Flameproof Visual Signal Xenon or Steady LED

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

ETAM3 XETK/FETK ECU Adapter, SAMTEC FFSD - SAMTEC SFM (10fc - 10fc), 0m11 User s Guide

xtablet T1600 Vehicle Holder Installation Guide

S20. Safety Switches. Phone: Fax: Web: -

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

Electric Rotary Module RE-50 I RE-75 Declaration of Incorporation Module Information Montage Instructions Maintenance Instructions

Expansion module EM-BAC-MOD-01. Installation manual

User Manual HMI Linkbox HL01 DP/MPI

Brochure Snap-Action Switches

Mounting and Operating Instructions EB EN. Electric Actuators Type 5824 without fail-safe action Type 5825 with fail-safe action

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

Explosion proof UL certified VoIP telephone. FernTel IP Z2 UL. Tabletop unit. Manual FHF BA /12

Type Quickstart (from device Version 2)

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Type Quickstart

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

PSR UC/ESAM4/3X1/1X2/B

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions

PHOENIX CONTACT - 01/2008

/ 2CKA001473B Technical Reference Manual Compact combination 1/1gang with T13 SSA-F-1.1.

Installation & Operation Instructions

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

NXT4 Three phase meter for commercial, industrial and advanced residential applications

Operating Instructions Wall saw WSE1217 USA

Assembly and Operating Instructions Door Control

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

SUBCON-PLUS-PROFIB...

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E


Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

Technical Manual Room temperature controller

E55C. Communication Industrial and Commercial. PLAN+ Modem. User Manual

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

PS/IO Circuit Board Retrofit

MC 11 EB-2 Power supply cabinet with external bus, AC version

INSTALLATION INSTRUCTIONS 07/2018

MDM 011-Z1 Regen Resistor

Metal Position Switch

Transcription:

Connect - Contact - Control 1 Connectors SB Series Circular connectors for special applications Manual A30-M.en

Contents 1. Important Basic Information...3 1.1 Legal Notes...3 1.2 Conventions for this Installation and Maintenance Instructions...3 2. General and Security Information...4 2.1 Observing the Installation and Maintenance Instructions...4 2.2 User Obligations...4 2.3 Proper Use...4 2.4 Improper Use...5 2.5 Ambient Conditions... 5 3. Dangers and Security Measures...5 3.1 Electrical Dangers...5 3.2 Risk of Damage...5 4. Description...6 5. Installation...7 5.1 Check Parts for Transport Damage...7 5.2 Preparation of Mounting Holes...8 5.3 Details Regarding Solder Contacts Crimp Contacts...8 5.4 Connection Solder Contacts...9 5.5 Connection Crimp Contacts...10 5.6 Assembly of the Contact Insert...12 5.6.1 Assembly at the Construction Site with Mobile Assembly Pliers...12 5.6.2 Assembly in the Workshop with Toggle Press...14 5.7 Assembly of the Connection...16 6. Maintenance...17 6.1 Maintenance Intervals...17 6.2 Visual Inspection at Each Plugging...18 7. Specifications...19 2 SB Series Connectors 2015-02-04 / V 1.1

Important Basic Information 1. Important Basic Information 1.1 Legal Notes Without prior written consent of Schaltbau GmbH, the installation and maintenance instructions is not allowed to be electronically or mechanically reproduced as a whole or in parts be distributed, changed, transmitted, translated into another language or used in any other way. Schaltbau GmbH cannot be held liable for damage caused by not observing (or only partly observing) the Installation and maintenance instructions. 1.2 Conventions for this Installation and Maintenance Instructions This instructions describe the installation and maintenance of the SB connectors. Cross references in this instructions are presented in bold italics. To highlight particularly important safety instructions and other information, the following symbols are used in this installation and maintenance instructions: DANGER Indicates a hazardous situation with a high level of risk which, if not avoided, will result in death or serious injury. WARNING Indicates a hazardous situation with a medium level of risk which, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation with a low level of risk which, if not avoided, may result in minor or moderate injury. Indicates a hazardous situation which, if not avoided, may result in property damage, such as service interruption or damage to equipment or other materials. Refers to technical features and methods aimed at facilitating work or to particularly important information. 2015-02-04 / V 1.1 SB Series Connectors 3

General and Security Information 2. General and Security Information The connectors described here are part of a low voltage system for special applications. They have been designed and checked in accordance with approved engineering regulations. Electrical equipment can generally cause severe harm to one s health and also material damage if used or operated improperly, or if not maintained sufficiently. The maintenance and installation instructions for the connectors must therefore be strictly followed. Any uncertainties must be clarified and all queries must include details of the type of device and the serial number. The planning and carrying out of mechanical and electrical installations, transportations, assemblies and commissioning as well as maintenance and repair work during installation, operation and maintenance, must therefore only be carried out by responsible experts with the appropriate expertise. This also applies to adherence to the general assembly and security regulations regarding electric power installations, as well as the correct use of certified tools. Electrical devices are to be protected, as much as possible, from dust and moisture during maintenance or storage. 2.1 Observing the Installation and Maintenance Instructions All staff must read and understand the instructions and adhere to them when working with the device. Always carefully observe all safety warnings! 2.2 User Obligations Observe all applicable national regulations, all safety, injury and environmental precautions as well as the recognised technical regulations with regards to safe and professional work. The proper functioning of all available protection and safety devices is to be checked regularly Work on electrical devices must only be carried out by experts or by instructed persons under the guidance and supervision of an expert according to the electro-technical regulations. An expert is a person who can judge and recognise the possible dangers of the jobs commended to him based on his training, knowledge and experience and by knowledge of the appropriate regulations. Staff must be informed clearly about who is responsible for the maintenance of the connectors. 2.3 Proper Use According to IEC 61984, connectors are components which must not be plugged or unplugged when voltage is present during intended use. 4 SB Series Connectors 2015-02-04 / V 1.1

Dangers and Security Measures 2.4 Improper Use 2.5 Ambient Conditions The connectors must not be converted or otherwise modified without prior written consent of Schaltbau GmbH. Violations against this will result in the exclusion of liability on the part of the manufacturer. None of the operating conditions defined in our catalogue A30.en in section Specifications, such as voltages, currents, or ambient conditions, etc. may be changed. Work on the connectors must only be carried out by staff who meets the requirements set out in these installation and maintenance instructions. The bridging of switches or other control devices is prohibited. The connectors are constructed for specific ambient conditions. Use the connectors only under the ambient conditions as defined in our catalogue A30.en in section Specifications. 3. Dangers and Security Measures 3.1 Electrical Dangers DANGER The connectors contain live voltage components. There is a risk of electric shock! Always consider the following safety rules before carrying out work on the connectors: Disconnect. Ensure that it is not possible to reconnect unintentionally. Make sure that there is no voltage present. 3.2 Risk of Damage Improper handling of the connectors, e.g. when hitting the floor with some impact, can result in breakage, cracks and deformation. Make sure that the connectors are always used properly. Regularly sight-check the connectors for potential damages. Immediately replace damaged components. 2015-02-04 / V 1.1 SB Series Connectors 5

Description 4. Description Connectors of the SB-series are circular connectors for special applications. They are particularly designed for operation locations in rail vehicles, where harsh ambient conditions have to be handled in daily operation. The connectors are permanently resistant to harsh weather conditions as they are equipped with silver plated or gold plated contacts in rubber sealed contact inserts. The connectors are typically used for systems and components that require high reliability and safety. This is why the SB-connectors are, for instance, used as supply line and control cable connectors for train protection systems installed in bogies of railway vehicles; as special connectors for harsh industrial applications. The connectors of the SB-series have a modular structure and are available in different versions, each as flange socket with the corresponding connector. Overview SB-series flange sockets and connectors Number of poles Flange sockets Connectors 5-pole + PE (protective conductor) 5 + PE pin contact Solder terminal: silver 5 + PE socket contact - Solder terminal:silver - Crimp terminal: silver 6-pole 6x socket contact Solder terminal: silver or gold 6x pin contact - Solder terminal: silver or gold - Crimp terminal: silver or gold 14-pole 14x pin contact Crimp terminal: silver 14x socket contact Crimp terminal: silver 6 SB Series Connectors 2015-02-04 / V 1.1

Installation 5. Installation DANGER The connectors contain live voltage components. There is a risk of electric shock! Always consider the following safety rules before carrying out work on the connectors: Disconnect. Ensure that it is not possible to reconnect unintentionally. Make sure that there is no voltage present. During installation, ensure that dirt caused by surrounding construction activities does not get into the connectors. 5.1 Check Parts for Transport Damage If parts are damaged, the functional reliability of the connectors is no longer given. Before installation, check all parts for any possible transport damage. Do not install any damaged parts. 2015-02-04 / V 1.1 SB Series Connectors 7

Installation 5.2 Preparation of Mounting Holes Dimensions The precise dimensions of the respective connectors and the flange socket versions are indicated in the respective data sheets or in our catalogue A30.en. Mounting holes For the assembly of the flange socket, a mounting hole as shown in the drawing below is required. The flange socket has to be fixed with four M5 screws. Tightening torque: Determined by the user, in consideration of the materials used for the construction Length of the screws: In consideration of the assembly situation The dimensions and the arrangement of the mounting holes are both shown in the drawing below. 38 ±0,1 38 ±0,1 40,2 +0,4 M5 oder Ø5,8 +0,2 Dimensions and arrangement of the mounting holes (Dimensions in mm) 5.3 Details Regarding Solder Contacts Crimp Contacts Version solder contacts Solder contacts are permanently assembled in the contact insert. The cable strands can be soldered directly to the pre-assembled contacts. Version crimp contacts Crimp contacts are not yet assembled to any component. When assembling the crimp contacts, the cable strands have to be crimped to the contacts first. Then, the contacts have to be pressed into the contact insert. 8 SB Series Connectors 2015-02-04 / V 1.1

Installation 5.4 Connection Solder Contacts Required tools/auxiliary materials Soldering tools Suitable solder Tools for removing insulation Procedure Strip jacket from cable (1) to a length of approx. 45 mm and the insulation of the stranded wires to approx. 10 mm. Thread cable gland (2) (OEM part, not included in the delivery) and connector shell (3) on the cable (1). Solder the cable strands to the contacts (4) on the contact insert. Make sure that no single strands stick out. In the end, check all solder terminals for stable and correct connection. 10 4 45 3 1 2 Connection solder contacts (Dimensions in mm) For assembling the contact insert into the connector shell, see 5.6 Assembly of the contact insert. 2015-02-04 / V 1.1 SB Series Connectors 9

Installation 5.5 Connection Crimp Contacts Overview crimp contacts Number of poles Contact type Ordering code Connection cross section Socket contact for connector Ø 6 Connection cross section B 4,2C 1,5 AG 1.5 mm 2 5-pole + PE 33 Pin contact for connector Ø 4.2 Connection cross section Pin 4,2 C 0,75-1 SZC-1,50-Au Pin 0.75... 1 mm 2 1... 1.5 mm 2 6-pole 39 14-pole Pin contact for flange socket Ø 1.58 Ø 3.76 Connection cross section 28.6 SAC-0,50-Ag SAC-1,00-Ag SAC-1,50-Ag SAC-2,50-Ag 0.5 mm 2 0.75... 1 mm 2 1.5 mm 2 2.5 mm 2 14-pole Socket contact for connector Ø 1.58 Ø 3.76 Connection cross section 28.6 BAC-0,50-Ag BAC-1,00-Ag BAC-1,50-Ag BAC-2,50-Ag 0.5 mm 2 0.75... 1 mm 2 1.5 mm 2 2.5 mm 2 (Dimensions in mm) Required tools/auxiliary materials Crimp tool for cross-section of connection 0.14 mm 2... 6 mm 2 (Ordering code: CWZ-600-1) Insertion tools for crimp contacts: - Insertion tool for pin contacts and socket contacts B 4,2C 1,5 AG, Pin B 4,2 C 0,75-1 and SZC-1,50-Au Pin (Ordering code: EWZ-4,2) - Insertion tool for pin contacts and socket contacts SAC xxx-ag and BAC-xxx-AG (Ordering code: EWZ-A) Tools for removing insulation 10 SB Series Connectors 2015-02-04 / V 1.1

Installation Procedure The connection of the crimp contacts has to be carried out in accordance with DIN EN 60352-2 solderless connections. Strip jacket from cable (1) to a length of approx. 45 mm and the insulation of the stranded wires to approx. 8 mm. Thread cable gland (2) (OEM part, not included in the delivery) and connector shell (3) on the cable (1). Crimp cable strands with crimp tool to the contacts (4). While doing so, consider the cross-sections of the connection, respective to the version of crimp contacts (see table Overview crimp contacts ). The crimping has to be carried out midway between the inspection hole and the end of the contact (see drawing below). Check crimp terminals for stable and correct connection. Make sure that no single strands stick out. Check extraction forces according to DIN EN 61238-1. The crimp contacts have to be inserted in the contact insert starting in the middle and moving outwards: While doing so, every single crimp contact (4) has to be pressed into the contact insert (5) with the insertion tool, until the contact clearly engages. The respective data sheets show how far exactly the contacts stick out of the contact insert. 8 5 4 45 3 1 2 5.9 Crimping point Connection Crimp contacts (Dimensions in mm) For assembling the contact insert into the connector shell, see 5.6 Assembly of the contact insert. 2015-02-04 / V 1.1 SB Series Connectors 11

Installation 5.6 Assembly of the Contact Insert When all the connections have been established on the contacts, the contact insert has to be pressed into the connector shell. This can be done either with the mobile assembly pliers directly on-site at the construction site or stationary in the workshop. 5.6.1 Assembly at the Construction Site with Mobile Assembly Pliers Required tools/auxiliary materials Mobile assembly pliers (A) with mounting mandrel (B) (Ordering code: EDZ-ST) Ethyl alcohol as lubricant Procedure Push the connector shell (D) to the completely wired contact insert (C). Moisten the contact insert (C) on the circumference with ethyl alcohol. Lubricants which do not evaporate, cause the contact insert to slip out of the connector shell. Do not use other lubricants, such as greases, oils, etc. Do only use ethyl alcohol as lubricant. D C B A C H D Slots and guides on the contact insert and on the connector shell. Mobile assembly pliers (A) with mounting mandrel (B) to mount the contact insert (C) into the connector shell (D) Set the contact insert (C) onto the connector shell (D) so that the slots (H) of the contact insert and the guides (H) on the connector shell are congruent. Note: The fivefold coding (H) prevents improper assembly. Manually push the contact insert (C) into the connector shell (D) as far as possible. 12 SB Series Connectors 2015-02-04 / V 1.1

Installation Put the pre-assembled contact insert (C) and the connector shell (D) with the cable into the assembly pliers. Put the mounting mandrel (B) into the holder (G) of the assembly pliers As for pin contacts, make sure that the mounting mandrel is being mounted in correct position in accordance with the arrangement of the contacts. Adjust the locating shoulder of the connector shell (E) so that it lays firmly on the locating shoulder of the assembly pliers (F). In order to prevent damages to the components, make sure that before and during pressing the contact insert, the mounting mandrel and the contact insert in the connector shell are laying on the same press axis; the locating shoulder of the connector shell (E) does not lift off of the locating shoulder of the assembly pliers (F). B G F E Inserting the pre-assembled connector into the assembly pliers In order to press the contact insert into the connector shell, press the handles of the assembly pliers several times until the contact insert (C) completely engages into the connector shell (D). Contact insert completely pressed into connector shell with assembly pliers 2015-02-04 / V 1.1 SB Series Connectors 13

Installation Check Check whether the engage contours (J) of the contact insert (C) are completely engaged into the connector shell (D), by measuring the distance between the contact tip and the end of the connector shell (target distance 103.2 mm, see drawing on the left). C J D If the contact insert does not completely engage, it can slip out of the connector shell during plugging or unplugging. Engage contours of the contact insert If the contact insert has not completely engaged: Readjust the assembly pliers and press the contact insert with the mounting mandrel again until the distance between the contact tip and the end of the connector shell is 103.2 mm. 103.2 Target distance between contact tip and the end of the connector shell 5.6.2 Assembly in the Workshop with Toggle Press EWZ-6P Insertion tool Required tools/auxiliary materials Insertion tool for contact inserts (Ordering code: EWZ-6P) Toggle press Suitable contact surface for the connector shell with cable recess Ethyl alcohol as lubricant Procedure Push the connector shell (D) to the completely wired contact insert (C). Moisten the contact insert (C) on the circumference with ethyl alcohol. Lubricants which do not evaporate, cause the contact insert to slip out of the connector shell. Do not use other lubricants, such as greases, oils, etc. Do only use ethyl alcohol as lubricant. 14 SB Series Connectors 2015-02-04 / V 1.1

Installation C H D Slots and guides on the contact insert and on the connector shell. Set the contact insert (C) onto the connector shell (D) so that the slots (H) of the contact insert and the guides (H) on the connector shell are congruent. Note: The fivefold coding (H) prevents improper assembly. Manually push the contact insert (C) into the connector shell (D) as far as possible. Put the connector shell with the cable side onto the prepared contact surface so that the cable route is guided in the cable recess without being crushed. Clamp the insertion tool into the toggle press As for pin contacts, make sure that the insertion tool is being clamped in correct position in accordance with the arrangement of the contacts. In order to prevent damages to the components, make sure that before and during pressing the contact insert, the insertion tool and the contact insert in the connector shell are laying on the same press axis. Press the contact insert (C) into the connector shell (D) with the insertion tool and the toggle press until the contact insert completely engages. Check Check whether the engage contours (J) of the contact insert (C) are completely engaged into the connector shell (D), by measuring the distance between the contact tip and the end of the connector shell (target distance 103,2 mm, see drawing on the left). C J D If the contact insert does not completely engage, it can slip out of the connector shell during plugging or unplugging. Engage contours of the contact insert If the contact insert has not completely engaged: Readjust the toggle press and press the contact insert with the insertion tool again until the distance between the contact tip and the end of the connector shell is 103,2 mm. 103.2 Target distance between contact tip and the end of the connector shell 2015-02-04 / V 1.1 SB Series Connectors 15

Installation 5.7 Assembly of the Connection Required tools/auxiliary materials Open-end spanner, AF (across flats) 30 and 46 Procedure Torsional forces on the contact insert can damage the connector. Always use the hexagon AF (across flats) 30 on the connector shell as counter support when assembly operations could exert torsional forces on the contact insert. Screw in the cable gland (2) (OEM part, not included in the delivery) into the connector shell (3). While doing so, use the hexagon AF (across flats) 30 on the connector shell with the open-end spanner as counter support in order to prevent torsional forces on the cable strands. If necessary, lubricate the thread of the union nut (4) / flange socket (5). In order to establish the connection, plug the connector into the flange socket (5). Screw on and tighten the union nut (4). Torque: 35 Nm up to max. 40 Nm. In the end, check all components for correct connection and tight seat. 46 30 5 4 3 2 Assembly of the connection 16 SB Series Connectors 2015-02-04 / V 1.1

Maintenance 6. Maintenance Note the expert knowledge which is essential for carrying out maintenance work, mentioned in chapter: 2. General and Security Information. DANGER The connectors contain live voltage components. There is a risk of electric shock! Always consider the following safety rules before carrying out work on the connectors: Disconnect. Ensure that it is not possible to reconnect unintentionally. Make sure that there is no voltage present. The following is a list of maintenance work which may be carried out on the connectors, by a trained specialist. 6.1 Maintenance Intervals The state of the connectors is dependent on environmental conditions. To ensure the correct function and prolonged operational life span of the connectors, the following checks and maintenance must be performed regularly: Test / Maintenance Visual inspection of - Connector - Cable - Union nut - Flange socket - Contacts - Contact insert Interval At each plugging 2015-02-04 / V 1.1 SB Series Connectors 17

Maintenance 6.2 Visual Inspection at Each Plugging At each plugging, the connectors with cable, the flange socket and all plug contacts and socket contacts have to be visually inspected. In case of visible damages to cable, connectors, flange socket, contacts or contact inserts, the functional safety of the connection is no longer given. Immediately replace all damaged components. Connector-element Visual inspection and function check Measures Connector Union nut on the connector Flange socket Check for: Ease of movement during plugging Dirt Visible damages to connector shell, contacts, contact insert Loose or missing fastening elements Check for: Ease of movement of the thread Damage to the thread Check for: Ease of movement during plugging Dirt Visible damages to socket shell, contacts, contact insert Loose or missing fastening elements Damage to the thread In case of defects: Remove potential dirt (abrasion of the contact surfaces), e.g. with compressed air or a nylon brush. Immediately replace defective components Repair the elements In case of defects: Immediately replace defective components If necessary, lubricate the thread In case of defects: Remove potential dirt (abrasion of the contact surfaces), e.g. with compressed air or a nylon brush. Immediately replace defective components Repair the elements 18 SB Series Connectors 2015-02-04 / V 1.1

Specifications 7. Specifications Specifications and information on the material characteristics for the connectors of the SB-series are given in our catalogue A30.en. 2015-02-04 / V 1.1 SB Series Connectors 19

Schaltbau GmbH For detailed information on our products and services visit our website or give us a call! with compliments: Schaltbau GmbH Hollerithstrasse 5 81829 Munich Germany Phone +49 89 9 30 05-0 Fax +49 89 9 30 05-350 Internet www.schaltbau-gmbh.com e-mail contact@schaltbau.de RoHS 2011/65/EC Schaltbau GmbH manufactures in compliance with RoHS. The production facilities of Schaltbau GmbH have been IRIS certified since 2008. Quality you can count on Schaltbau Certified to DIN EN ISO 14001 since 2002. For the most recent certificate visit our website. Quality you can count on Schaltbau Certified to DIN EN ISO 9001 since 1994. For the most recent certificate visit our website. Electrical Components and Systems for Railway Engineering and Industrial Applications Connectors Connectors manufactured to industry standards Connectors to suit the special requirements of communications engineering (MIL connectors) Charging connectors for battery-powered machines and systems Connectors for railway engineering, including UIC connectors Special connectors to suit customer requirements Snap-action switches Snap-action switches with positive opening operation Snap-action switches with self-cleaning contacts Enabling switches Special switches to suit customer requirements Contactors Single and multi-pole DC contactors High-voltage AC/DC contactors Contactors for battery powered vehicles and power supplies Contactors for railway applications Terminal bolts and fuse holders DC emergency disconnect switches Special contactors to suit customer requirements Electrics for rolling stock Equipment for driver's cab Equipment for passenger use High-voltage switchgear High-voltage heaters High-voltage roof equipment Equipment for electric brakes Design and engineering of train electrics to customer requirements Printed in Germany We reserve the right to make technical alterations without prior notice. For updated product information visit www.schaltbau-gmbh.com..