VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

Similar documents
Quick Installation Guide

VertX. V100, V200, V300, V1000, and V2000 Installation Guide Barranca Parkway Irvine, CA USA

VertX EVO V1000 Installation Guide Barranca Parkway Irvine, CA USA. July 2011 Document Number: Rev A.1

Installation Guide. Avigilon ACM Embedded Controller

VertX EVO V2000. Installation Guide Barranca Parkway Irvine, CA USA. April 2012 Document Number: Rev A.2

Suprex RS-485 SPX-7500 Wired Reader-Extender

Connecting a Cisco Input Module

TruPortal Dual Door Interface Module Quick Reference

FlexPass. ASR Long Range Reader. Installation Guide Jeronimo Road Irvine, CA July 16, 2007 Document Number K , Rev B

Parts 1 - Reader and base plate assembly 1 - Installation guide 2 - Terminal connector - terminal readers only

Two Door Controller GEN-045

Edge Device with Brivo ACS Plug-in for WebServices and OnSite SE. Quick Start Guide

Quick Start Installation Guide

istar Pro Installation Guide

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

Quick Start Installation Guide

SEC-H-201 Security Controller

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

UC-2000 Installation Manual Unicorn Computers Technology Limited

Quick Start Installation Guide

CYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314

PXL-250 Tiger Controller

Access Control System Document Number: , Rev. D. Installation Guide. Essential Essential Plus Elite 36 Elite 64

6222 Two Door Module Technical Operations Manual

MR52 READER INTERFACE

Connecting a Cisco Reader Module

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

SPX-7400_SPX-7410_MAN_161028

INSTALLATION INSTRUCTIONS

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

SmartLock Pro INSTALLATION MANUAL

1.3 Operating Conditions -40 F to 150 F (-40 C to 65 C) 0% to 90% Relative Humidity, non-condensing

Connecting a Cisco Output Module

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

EA500. Installation Instructions Transponder

Installation manual CF8-W-Disp-AL

NXT-1R/-3R/-5R Exit Reader Installation Drawing 4-Conductor - OR - CAT-5 Cabling. IO-Plus (Green) Ground (Black) +12 VDC (Red) Shield (Silver)

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

SmartLock Controller INSTALLATION MANUAL

16-Way Input 48-Way Output Card

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:

1.0 Wiring and Layout Diagrams

MR51e Reader Interface

PRT-RDS2 Standard 2 Reader Expander

Installation & Operation Guide

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

TT-NRM. Network Relay Module Installation Instructions WARNING:

CA-A480-A Elevator Controller. Reference & Installation Manual

emerge Essential Access Control System

PMC494 10BaseT to 10Base2 PMC Media Converter

Quick Start Installation Guide

EAP 300 REMOTE ANNUNCIATOR INSTALLATION MANUAL. r.0454a

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

IPassan Installation guide

Wiring Guide EP.HIO. Version 1.03 Last Updated:

TruPortal Output Expansion Board Quick Reference

0DQXIDFWXULQJ $FFHVV &RQWURO VLQFH

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

PRO3200 Professional Modular Access Control Hardware

NETWORK CONCENTRATOR LINK. This equipment must only be installed and serviced by professional qualified personnel.

IEI emerge MicroNode Install and Setup Guide. Contents

Installation Manual. Contents

Mitsubishi Electric Automation Instruction Manual FR-A5AC-01

Expandable Power Systems

Brivo Access Control System (ACS) Installation Manual DOCUMENT NUMBER ENG-DOC-003 ACS5000-E ENG-WI-001

PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board

Gallagher GBUS Devices

Suprex Ethernet SPX-7200 Ethernet Reader-Extender

USER S MANUAL Power Supply for Backplane Vdc

ControlNet Comm Glass Fiber Adapter Kit

TAC I/NETTM 1284, 1280, Security Control Unit

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316

SINGLE READER EXPANSION MODULE

LTEC Heat Pump DDC Controller

Cardax FT Controller 3000

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

Installation Instructions RF5010 and RF5210

AC-215x-B Series 2-Reader Networked Access Control Panel Hardware Installation and User Manual. Models: AC-215-Bx AC-215-DIN AC-215IP-Bx AC-215IP-DIN

Installing Sentor. Hardware Installation

MR50 READER INTERFACE

Power Hub Cat. No. 83A00-1. Installation Manual WEB VERSION

PRO2200 Professional Modular Access Control Hardware

Carbon Monoxide Sensor - ModBus

Installation Instructions (KF-2000)

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

MS-5000: MiniStar Reader

900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

SPX-7400 Series. Operations Manual. Suprex Reader Extender - Fiber Optic Interface. SPX-7400 shown with EXP-2000 SPX-7400_MAN_082112

genesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010

Installation Instructions RF5010 and RF5210

MASC. Managed Automated Security Controls. MAC-4R Hardware Installation Manual

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

CardaxFT Reader I/O Interface

NS1 Connection Unit Guide

Transcription:

15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1.

Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications... 4 Overview... 4 Step 1 Preparations... 5 1.1 What you need before getting started... 5 1.2 V100, V200, or V300... 5 Step 2 Hardware Installation... 6 2.1 Mounting... 6 2.2 Wiring VertX... 6 Contact Information... 10 November 2011 Page 2 of 10

Introduction HID s VertX open platform is flexible and scalable to permit economic and high performance access control solutions for a wide range of applications. The VertX units interconnect through different sub-networks and protocols to a standard TCP/IP network with the capability of a variety of applications. The VertX Interface Panels are designed for control by a VertX V1000 Access Controller. The V100 Door/Reader Interface panel controls two sets of door devices or one door with Card In/Card Out (a reader on both sides of the same door). The V200 Input Monitor Interface panel monitors as many as 16 input points. The V300 Output Control Interface panel controls as many as 12 output relays. Parts List V100, V200 and V300 Quantity Interface Panel 1 Mounting screws 4 2.2K EOL resistors 32 Quick Installation Guide 1 Note: VertX Interface panels require installing a V1000 Controller. See the V1000 Wiring Diagram Example. Product Specifications Description Power Supply Maximum Current at 12VDC per unit Average operating current at 12VDC Operating temperature range Humidity Specification 12-16VDC 1 Amp V100-450mA (with two R40 iclass Readers) V200-60mA V300-75mA 32-120 F (0-49 C) 5% to 85% non-condensing November 2011 Page 3 of 10

Cable Specifications Cable Type Length Specification RS-485 * 4000 feet (1220 m) to host Input Circuits * 500 feet (150 m) Output Circuits * 500 feet (150 m) Wiegand Power Supply +12 VDC IN Using Belden 3105A, 22AWG twisted pair, shielded 100Ω cable, or equivalent. 2-conductor, shielded, using ALPHA 1292C (22AWG) or Alpha 2421C (18AWG), or equivalent. 2-conductor, using ALPHA 1172C (22AWG) or Alpha 1897C (18AWG), or equivalent. 500 feet (150 m) to reader ALPHA 1299C, 22AWG, 9-conductor, stranded, overall shield. Fewer conductors needed if all control lines are not used. ---- Refer to your Power Supply Installation Guide. Minimum wire gauge depends on cable length and current requirements. Overview The following outlines what is required to installing VertX interface panels. November 2011 Page 4 of 10

Step 1 Preparations 1.1 What you need before getting started Prior to starting the installation, completely read this guide. CAUTION: VertX Interface panels are sensitive to Electrostatic Discharges (ESD). Observe precautions while handling the circuit board assembly by using proper grounding straps and handling precautions at all times. 1.2 V100, V200, or V300 1. If attaching the V100-Series panel to the end of the RS-485 bus, install a terminating jumper to the In position on the termination resistor pins, P8 on the cover (P10 on the PCB) of the V100, V200 and V300. 2. If the V100-Series panel is being installed as part of an array, or in a third party enclosure, follow the directions provided by the Integrator or Dealer. Terminating Jumper November 2011 Page 5 of 10

Step 2 Hardware Installation 2.1 Mounting 1. Always mount the interface panels in a secure area. 2. Mount using the four mounting screws (provided) or other appropriate fasteners. Place the fasteners in the corner holes of the base. 3. Stack the VertX devices with or without the cover. Do not remove the plastic base. Position the VertX devices in such a way as to provide room for wiring, air-flow and cable runs. CAUTION: Stacking the VertX devices without the cover risks the danger of breaking the LEDS unless spacers are used for separation. 2.2 Wiring VertX CAUTION: Connectors on the VertX devices are positioned to be mirror images and are not interchangeable once the installation is complete. Therefore, you cannot unplug a connector from one side and plug it into the corresponding connector on the other side. 1. Power and Alarm input connections (All VertX units): Connect power by providing 12VDC to the P7 or P9 connector. +12VDC goes to P7 Pin 1 or P9 Pin 8 and ground to P7 Pin 2 or P9 Pin 7. Batt Fail, AC Fail, and Tamper switch inputs are wired as shown in the table. Connect the Bat Fail and AC Fail inputs to battery low/failure and AC failure contacts provided on the power supply. Connect the Tamper input to a tamper switch on the enclosure. Pin # P7 1 +12VDC 2 Ground 3 Bat Fail - 4 Bat Fail + 5 AC Fail - 6 AC Fail + 7 Tamper - 8 Tamper + November 2011 Page 6 of 10

2 Reader Connections (V100): Connect Wiegand or clock-and-data interfaces to a V100 using the connection table shown. You can connect up to 10 signal lines for the reader. Use as many of the signal lines as required for your reader interface. Note: Connect the data return line to the same ground as the reader power if the reader is not powered by the VertX units 12VDC. Pin # V100 P1 V100 P4 1 Reader Power Shield Ground 2 Ground Hold 3 Data 0 / Data Beeper 4 Data 1 / Clock Red LED 5 Data Return Green LED 6 Green LED Data Return 7 Red LED Data 1 / Clock 8 Beeper Data 0 / Data 9 Hold Ground 10 Shield Ground Reader Power 3. RS-485 Connections Connect the V100 panel to the V1000 controller through the RS-485 cable. See the V1000 Quick Install Guide for further information. CAUTION: The V1000 RS-485 Ports 1 & 2 (P1) are a common bus and therefore cannot have panels with duplicate Interface Addresses assigned. The same is true of the V1000 RS-485, Ports 3 & 4 (P4). For example, two panels, both with Interface Address 0 (factory default), cannot be connected to Ports 1 and/or 2 (P1). 4. Interface Address Set the interface address by turning the Address dial. Ensure that the V100 Interface Address is documented in the Hardware Installation Worksheet (found in the back of the HID VertX V1000 Quick Install guide). November 2011 Page 7 of 10

5. Output Connections (All VertX units) All Output connections are used for general purpose controls. The following table shows where the various outputs are located. Pin numbers shown use the convention NO/C/NC. For example, Output 1, V2000: P3 Pin1 is NO (Normally Open,) Pin 2 is C (Common,) and Pin 3 is NC (Normally Closed). Note: Relays are dry contact rated for 2Amps @ 30VDC. Output number 1 2 3 V100 V200 V300 P3 Pins 1/2/3 Strike (lock) Relay 1 P3 Pins 4/5/6 Aux Relay 1 P6 Pins 6/5/4 Strike (lock) Relay 2 P3 Pins 2/3/4 P1 Pins 1/2/3 P6 Pins 3/2/1 P1 Pins 4/5/6 P1 Pins 7/8/9 4 P6 Pins 3/2/1 Aux Relay 2 P2 Pins 1/2/3 5 P2 Pins 4/5/6 6 P2 Pins 7/8/9 7 P4 Pins 9/8/7 8 P4 Pins 6/5/4 9 P4 Pins 3/2/1 10 P5 Pins 9/8/7 11 P5 Pins 6/5/4 12 P5 Pins 3/2/1 CAUTION: Some magnetic locks exhibit both high inrush current when activated and a high instantaneous break voltage when de-energized due to magnetic field collapse. It is recommended you use of a snubber circuit across the controlling relay terminals to protect the controlling relay contacts. Go to support.hidglobal.com, see Solution 891 - How do I wire a High In-Rush Current locking device to VertX/Edge/Edge Solo?. 6. Input Connections (All V100-Series devices) Input connections are analog inputs used for a combination of specific functions such as Request-to-Exit (REX), Door monitor, etc. They can also be used as general purpose monitoring. Connect one side of the switch or contact to the + (plus) lead and the other to the (minus) lead. The following table shows where the inputs are located. Pin numbers shown on the cover use the convention +/. The default REX input configuration is normally open (NO) unsupervised (no EOL resistors). However, the default door switch (DS) configuration is Normally Closed (NC), unsupervised (no EOL resistors). All other input points are defaulted for NO switches and are unsupervised (no EOL resistors). November 2011 Page 8 of 10

Any input can be configured as NO or NC, as well as unsupervised or supervised. They can be configured for supervisory resistors of 1K 6K Ohm. The setup of supervised inputs should be done during configuration of the VertX devices via the host Example: Input 1, V1000 is: P14 Pin1 is + and Pin 2 is -. Except for the door monitor, all other inputs default to NO, unsupervised: Supervised inputs can be configured for: Input Number V100 V200 V300 1 P2 Pins 1/2 Door Monitor P1 Pins 1/2 P6 Pins 2/1 2 P2 Pins 3/4 REX input P1 Pins 3/4 P3 Pins 1/2 3 P5 Pins 4/3 Door Monitor P1 Pins 5/6 P7 Pins 8/7 Tamper 4 P5 Pins 2/1 Rex Input P1 Pins 7/8 P7 Pins 6/5 AC Fail 5 P7 Pins 8/7 Tamper P1 Pins 9/10 P7 Pins 4/3 Batt Fail 6 P7 Pins 6/5 AC Fail P2 Pins 1/2 7 P7 Pins 4/3 Batt Fail P2 Pins 3/4 8 P2 Pins 5/6 9 P4 Pins 10/9 10 P4 Pins 8/7 11 P4 Pins 6/5 12 P4 Pins 4/3 13 P4 Pins 2/1 14 P5 Pins 6/5 15 P5 Pins 4/3 16 P5 Pins 2/1 17 P7 Pins 8/7 Tamper 18 P7 Pins 6/5 AC Fail 19 P7 Pins 4/3 Batt Fail November 2011 Page 9 of 10

Contact Information Americas HID Global (California, USA) support: support_na@hidvertx.com sales: sales@hidvertx.com main: 949 732 2000 sales: 800 210 4744 telephone: 800 237 7769 fax number: 949 732 2120 Europe, Middle East and Africa HID Corporation, Ltd. (Haverhill, UK) support: support_emea@hidvertx.com sales: salesemea@hidvertx.com telephone: +44 1440 714 850 fax number: +44 1440 714 840 Asia-Pacific HID Asia Pacific Ltd. (Hong Kong) support: support_apac@hidvertx.com sales: salesapac@hidvertx.com telephone: (852) 3160 9800 fax number: (852) 3160 4809 November 2011 Page 10 of 10