Processing UK NEQAS Differential and Reticulocyte Specimens on Sysmex Analysers

Similar documents
Insight Program Modification

Getting Started with LimeSurvey

Lab ID 406. Your Parameters. Institution: Analyte. WBC Siemens Advia 120 Siemens 10 9 /L. RBC Siemens Advia 120 Siemens /L

To complete this project, you will need the following folder:

Fast Facts. for Operating the scil Vet abc Plus. Hematology Chemistry Digital Radiography Ultrasound Orthopedics Education

Unscrew and remove the cap from the waste tank

Introduction to Nesstar

GRAPHIC #1. Open . Save

Letter Assistant Word 2003 Setting up a New Letter DOC

Orifice Flow Meter

Unicel DxH 600 System

IP4 - Running reports

Check the box against WorldSmart Toolbar Integration and click OK. This integrates WorldSmart Toolbar with Microsoft Outlook.

ELECTIVES MODULES. Implement. Electives. Setup. Troubleshooting. Basics

Creating an Online Course

Application Browser! THE CONFIGURATION SOFTWARE FOR THE LUCIA M MODELS. Lab. gruppen is an individual in

Section 1-3A: Creating a hierarchically numbered list style

Code Matrix Browser: Visualizing Codes per Document

Lab - Create a Partition in Windows 8

TYPING IN ARABIC (WINDOWS 7)

Installing a Custom AutoCAD Toolbar (CUI interface)

1. Log in Forgot password? Change language Dashboard... 7

OMEGA APPLICATION NOTE - AN001 Introduction to OM-LMPLC programming Simple output cycling COPYRIGHT OMEGA

Introduction. Getting to Know Word The Ribbon. Word 2010 Getting Started with Word. Video: Exploring Your Word 2010 Environment.

1. Below is an example 1D river reach model built in HEC-RAS and displayed in the HEC-RAS user interface:

From the Insert Tab (1), highlight Picture (2) drop down and finally choose From Computer to insert a new image

BD FACSLink LIS Interface Solution User s Guide

This guide will introduce you to the changes coming with in General Laboratory.

Tremblay Harrison Inc Dufferin St Toronto, ON M6H 3M Version 1.2

CONNECTION TO A HOST COMPUTER

The MAXQDA Stats Data Editor

Home Tab Training. Page 1/5

Newforma Contact Directory Quick Reference Guide

Using Tables, Sparklines and Conditional Formatting. Module 5. Adobe Captivate Wednesday, May 11, 2016

1. Hiding/Showing Edit Controls

Filtering - Zimbra

In the Configuration Tree, right-click Multi-Range and select Create Repository.

20 - Analyzing Focus Groups

Clinical Staff. Healthcare you can trust. Sunquest ICE Desktop. Support available through: IT Service Desk for IT issues: Tel:

Creating an Online Course

Records are deduplicated as they are read into the CRS but it is sometimes useful to deduplicate manually.

How to Navigate MAX Survey

Spotlight Session Analysing answers to open-ended questions from surveys

How To: Advanced CMA

UK NEQAS BTLP Training Assessment and Competency Tool (TACT) User Instruction Manual

Getting Started with dotstaff Client Manager Guide

BROWSERS OPTIMIZATION

Table of Contents. Step 1: Originator...3. Step 2: Recipient...9. Step 3: Originator Step 3: Recipient Step 5: Recipient...

Building Projects with Campus Labs - Baseline

Oracle Big Data Cloud Service, Oracle Storage Cloud Service, Oracle Database Cloud Service

CHAPTER 4: RECORD LINKS

Performing Electronic Pathology Requesting using EMIS LV Practice System. To request a Test when in EMIS LV Consultation Mode (CM)

ESD Website Tutorial 1: Basic Editing. Please login to our NEW website:

Banner INB: Student (Adjustments) Targets, Waivers and Substitutions (SMASADJ)

Changing Button Images in Microsoft Office

Microsoft MOS-EXP. Microsoft Excel 2002 Core.

Chapter Copy Buckets

This information is aimed at new users who have recently purchased Viewline or are trialling our CCTV reporting product.

FXCC MT4 MultiTerminal User Guide

Uploading Journal Entries from Excel

Dreamweaver CS3. Chapter 1. Creating a Dreamweaver Web Page and Local Site. Part 1

How to Create Greeting Cards using LibreOffice Draw

Re-Registration Guide for Participants. Quality Management 679 Liam Whitby and Matthew Dyson 1.2 Matthew Dyson 04-Feb-2019 N/A unknown

Contents. Page. Installation ClaroRead Toolbar ClaroRead Features Font... 4 Spacing Homophones... 11

Reducing Network Utilization When Consolidating Log Events

Customer Account Center User Manual

Microsoft Office 2016 Mail Merge

PCSchool Search User Guide. Search User Guide. Created in version /11

Outlook Express. Setting up the View. Toolbar. Listing of messages OUTLOOK BAR. Status Bar

Shopping Cart: Queries, Personalizations, Filters, and Settings

NMU EduCat Course Settings

WELCOME TO KIN (KIRKWOOD INFORMATION NETWORK) Initial steps to set up KIN on your computer.

Uploading Files to CMS

Gallios TM Quick Reference

Getting Started With VERIS 6.0

LSRFortessa Guide. Cell Evaluation and Therapy Core HO324

Rexel UK Supplier Portal. Work Instructions. View, Print & Save a Document

Word 2010 Getting Started with Word. Introduction. Getting to know Word The Ribbon. Video: Exploring Your Word 2010 Environment

CONTENT MIGRATION ANGEL TO BLACKBOARD CONTENTS

Resizing and Renaming Images For Submitting By Jerry Koons

Ticket Mail Merge Instructions for MS Word 2007 and 2010

Word 2016 Advanced. North American Edition SAMPLE

How to update or change your banking information in isolved

End-of-Year Serials. Steps to Removing Issues at the End of the Year

Entering AC Results in the New PT Lab Center. Please note: Instructions specific to AC results begin on Page 4.

Mail Merge. To Use Mail Merge: Selecting Step by Step Mail Merge Wizard. Step 1:

Total WBC count and differential WBC count HemoCue WBC DIFF system

HERA and FEDRA Software User Notes: General guide for all users Version 7 Jan 2009

Quick Instruction Guide for Operating the scil Vet abc Plus

OpenClinica - Data Import & Export

INDEX 1. What is Registering a Temporary-user 2. How to Register a Temporary-user 3. Modifying Temporary-user Details 4. Deleting a Temporary-user

DIRECT ADMISSIONS SYSTEM

Ground Game Management

Log into the computer using your CU Denver username and password. Log into the DIVA software using your CU and Username and the password flow

Depending on the computer you find yourself in front of, here s what you ll need to do to open SPSS.

Step-by-Step Data Acquisition Part II Exercise 2: Generating an Analog Output Waveform

2. This will bring you to a new window asking what type of policy you are inserting. Personal Policies. Commercial Policies. All Other Policies

SPORTY HQ USER GUIDE FOR CLUB ADMINISTRATORS IN BRISBANE

Downloading of Tender Documents on BEML SRM System

Specimen Label Template Implementation Requirements, Installation, and Use

Transcription:

Page 1 of 8 Processing UK NEQAS Differential and Reticulocyte Specimens on Sysmex Analysers Please follow the instructions from NEQAS regarding specimen handling very carefully for each survey. Only process the survey through the mode requested by UK NEQAS. Full Blood Count surveys should be processed for CBC or CBC/DIFF only profiles. Do not perform any additional profiles as this may cause different parameters to be reported. Do not perform FBC survey through QC Mode. In order to obtain the correct results, the UK NEQAS Automated Differential Leucocyte Count (ADLC) and sometimes Reticulocyte Count surveys have to be processed using the QC mode analysis profile on Sysmex haematology analysers. Only UK NEQAS ADLC samples with the correct matrix letter of J are for Sysmex analysers. Please see instructions below on how to process the UK NEQAS samples. XN Series 1. Select the QC icon from the main menu of the XN IPU. 2. Select an empty control file.

Page 2 of 8 3. Select the REGIST option from the toolbar at the top. 4. At the Input Lot Information screen, select the material as Control Level 1, 2 or 3 but NOT Other.

Page 3 of 8 5. Type an eight digit identifier for Lot Number. For example NEQASAD1. If you wish to use the same file over and over again, enter expiry date well into the future. Then press OK to confirm. 6. The above process can be repeated again if you wish to have a separate file for the other samples. 7. On the XN analyser, ensure the system is at Ready. Press the change mode on the analyser so that it is in manual mode. 8. From the XN IPU screen, select the analyser menu for the relevant analyser (if more than one) and select QC Analysis. 9. From the list that appears, select the file created for running this UK NEQAS sample.

Page 4 of 8 10. Once selected, after mixing the sample, place in tube holder and press the blue process button on the XN. 11. Accept the results, then print out result from QC file or Explorer screen if necessary. XE & XT Series This method assumes that you are not using Level 1 on the QC program. If you are using Level 1, then substitute for a file that you are not using. If all three levels are in use, please call Sysmex UK for further instruction on 0870 902 9216. 1. Select the QC icon from the main menu of the system IPU. 2. Go to the Control tab.

Page 5 of 8 3. Ensure correct analyser is showing in the field Instrument ID. 4. Select Level 1 for Level. 5. Select New for Lot. 6. Select Manual for Mode. If processing through closed mode then select Closed. 7. Press the button Lot No. 8. Type an eight digit identifier for Lot Number. For example NEQASAD1. If you wish to use the same file over and over again, enter expiry date well into the future. Then press OK to confirm

Page 6 of 8 Processing on XE Series On the XE main unit, ensure the system is at Ready. From the main menu screen select QC. Select Exec. QC. Select the file that has been set up for this NEQAS sample. Process the sample through manual mode. For closed mode analysis, use Manual Closed Mode. Accept the results and print out from Explorer screen if necessary. Processing on XT Series On the XT main unit, ensure the system is at Ready. From the IPU main menu, select QC Analysis. Select the file that has been set up for this NEQAS sample. Process the sample through the manual mode. For closed mode analysis, process through Manual Closed Mode. Accept the results and print out from Explorer screen if necessary.

Page 7 of 8 XS Series 1. From the XS IPU main menu, select the QC files icon. 2. Select an empty file and click on Input. 3. Select Control Level 1, 2 or 3, but NOT Other from the drop down list.

Page 8 of 8 4. Type an eight digit identifier for Lot Number. For example NEQASAD1. If you wish to use the same file over and over again, enter expiry date well into the future. Then press OK to confirm 5. Ensure the system is a ready. 6. From the main menu screen, select Manual and click on QC button that appears on the Manual ID entry screen. 7. Select the file that has been set up for this NEQAS sample. 8. Once selected, after mixing the sample, place in tube holder and press the process button on the XS. 9. Accept the results and print out from Explorer screen if necessary.