Power and Cooling Innovations in Dell PowerEdge Servers

Similar documents
Dell OpenManage Power Center s Power Policies for 12 th -Generation Servers

Increasing Energy Efficiency through Modular Infrastructure

for Power Energy and

Dominick Lovicott Enterprise Thermal Engineering. One Dell Way One Dell Way Round Rock, Texas

Boundless Computing Inspire an Intelligent Digital World

Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions

HUAWEI Tecal X6000 High-Density Server

Dell Energy Smart Solution Advisor (ESSA)

A Comparative Study of Microsoft Exchange 2010 on Dell PowerEdge R720xd with Exchange 2007 on Dell PowerEdge R510

A Dell Technical White Paper Dell Virtualization Solutions Engineering

Dell Server Management Pack Suite Version 6.1 for Microsoft System Center Operations Manager User's Guide

HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6000 High-Density Server

OpenManage Power Center Demo Guide for

COMPLETE AGENT-FREE MANAGEMENT OF POWEREDGE SERVERS

Systems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure

Intel Xeon E v4, Windows Server 2016 Standard, 16GB Memory, 1TB SAS Hard Drive and a 3 Year Warranty

vstart 50 VMware vsphere Solution Specification

Intel Xeon E v4, Optional Operating System, 8GB Memory, 2TB SAS H330 Hard Drive and a 3 Year Warranty

HUAWEI Tecal X8000 High-Density Rack Server

Intel Server. Performance. Reliability. Security. INTEL SERVER SYSTEMS

Resource Saving: Latest Innovation in Optimized Cloud Infrastructure

Sugon TC6600 blade server

Intel Server. Performance. Reliability. Security. INTEL SERVER SYSTEMS FEATURE-RICH INTEL SERVER SYSTEMS FOR PERFORMANCE, RELIABILITY AND SECURITY

The PowerEdge M830 blade server

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Scale out Server

Reference Architecture Microsoft Exchange 2013 on Dell PowerEdge R730xd 2500 Mailboxes

Dell EMC Server Management Pack Suite Version 7.0 for Microsoft System Center Operations Manager. User's Guide

Data Sheet Fujitsu Server PRIMERGY CX400 M1 Compact and Easy

Comparing the Performance and Power of Dell VRTX and HP c3000

Dell Solution for High Density GPU Infrastructure

Cisco MCS 7845-H1 Unified CallManager Appliance

Microsoft SQL Server in a VMware Environment on Dell PowerEdge R810 Servers and Dell EqualLogic Storage

Huawei FusionServer. V5 Rack Server HUAWEI TECHNOLOGIES CO., LTD.

DNS-2608 Enterprise JBOD Enclosure User Manual

RS U, 1-Socket Server, High Performance Storage Flexibility and Compute Power

PowerExecutive. Tom Brey IBM Agenda. Why PowerExecutive. Fundamentals of PowerExecutive. - The Data Center Power/Cooling Crisis.

Deploy a High-Performance Database Solution: Cisco UCS B420 M4 Blade Server with Fusion iomemory PX600 Using Oracle Database 12c

Huawei FusionServer. V5 Rack Server HUAWEI TECHNOLOGIES CO., LTD.

GW2000h w/gw175h/q F1 specifications

Consolidating Microsoft SQL Server databases on PowerEdge R930 server

Meet the Increased Demands on Your Infrastructure with Dell and Intel. ServerWatchTM Executive Brief

OpenManage Management Pack for vrealize Operations Manager version 1.1. User s Guide

Innovation Makes Computing Simple

Best Practices for Setting BIOS Parameters for Performance

Figure 1 shows the appearance of Huawei FusionServer RH8100 V3 Rack Server. The RH8100 V3 provides three front I/O modules:

ClearPath Forward Libra 8480 / 8490

Lenovo Database Configuration for Microsoft SQL Server TB

Cisco HyperFlex HX220c Edge M5

Power Management in Intel Architecture Servers

Cisco MCS 7825-I1 Unified CallManager Appliance

Integrated Ultra320 Smart Array 6i Redundant Array of Independent Disks (RAID) Controller with 64-MB read cache plus 128-MB batterybacked

4-Bay Enclosure for 3.5in SATA Drives - Thunderbolt 2 - RAID

Dell PowerEdge R620. Owner's Manual. Regulatory Model: E16S Series Regulatory Type: E16S001

Why Customers Should Insist on Dell Enterprise Hard Drives for their Enterprise Systems

UCS M-Series + Citrix XenApp Optimizing high density XenApp deployment at Scale

Dell PowerEdge R640. Technical Specifications. Regulatory Model: E39S Series Regulatory Type: E39S001

Dell XC720xd Owner's Manual

Dell EMC PowerEdge R7425

MECHANICAL AND THERMAL CONSIDERATIONS FOR RACK DEPLOYMENT OF THE DELL POWEREDGE M-SERIES. One Dell Way Round Rock, Texas

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Intergenerational Energy Efficiency of Dell EMC PowerEdge Servers

Dell PowerEdge R430. Owner's Manual. Regulatory Model: E28S Series Regulatory Type: E28S001

1.2 Intel Server Chassis SC5400BASE Summary

Dell PowerEdge T330 Owner's Manual

Dell PowerEdge R330 Owner's Manual

Dell PowerEdge C410x. Technical Guide

ANNEXES. to the. COMMISSION REGULATION (EU) No /.. of XXX

The PowerEdge FX Architecture Portfolio Overview Re-inventing the rack server for the data center of the future

Dell PowerEdge T130 Owner's Manual

Side-by-side comparison of the features of Dell EMC idrac9 and idrac8

Intel SeRVeR SyStemS

Dell EMC PowerEdge R7415

Consolidating OLTP Workloads on Dell PowerEdge R th generation Servers

Dell EMC PowerEdge R540

HP solutions for mission critical SQL Server Data Management environments

SUN SERVER X2-8 SYSTEM

Dell PowerVault MD Family. Modular Storage. The Dell PowerVault MD Storage Family

SUN BLADE 6000 CHASSIS

OpenManage Management Pack for vrealize Operations Manager version 1.0 User s Guide

Altos T310 F3 Specifications

Dell PowerEdge R430 Owner's Manual

Accelerating storage performance in the PowerEdge FX2 converged architecture modular chassis

Power Management in Cisco UCS

Shared Infrastructure: Scale-Out Advantages and Effects on TCO

Server Success Checklist: 20 Features Your New Hardware Must Have

8233-E8B 3x6-core ENERGY STAR Power and Performance Data Sheet

NEC Express5800/R120e-1M System Configuration Guide

Dell EMC PowerEdge R6415

Dell EMC PowerEdge R540

Dell Dynamic Power Mode: An Introduction to Power Limits

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node

Cisco Secure Network Server

p5 520 server Robust entry system designed for the on demand world Highlights

Workstation Rack-Mount 4 RU Workstation, 4 RU Rack-Mount, Hexa-Core 3.5 GHz CPU, 16 GB DDR4 RAM, 256 GB SSD

PowerEdge T630. Innovative management with intelligent automation. Deliver peak performance. Maximize operational efficiency

TECHNOLOGIES CO., LTD.

Dell EMC Microsoft Exchange 2016 Solution

Cisco Connected Safety and Security UCS C220

Ultimate performance and security in a 2U Form factor.

Transcription:

Power and Cooling Innovations in Dell PowerEdge Servers This technical white paper describes the Dell PowerEdge Energy Smart Architecture and the new and enhanced features designed into Dell PowerEdge 13th generation servers Dell Enterprise Systems Engineering March 2016 John Jenne Craig Klein A Dell Technical White Paper

Revisions Date March 2016 Description Initial release This white paper is for informational purposes only, and may contain typographical errors and technical inaccuracies. The content is provided as is, without express or implied warranties of any kind. Copyright 2016 Dell Inc. All rights reserved. Dell and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies. 2 Power and Cooling Innovations in Dell PowerEdge Servers

Table of contents Executive summary... 4 Introduction... 4 Dell s Energy Smart Architecture... 5 Design... 6 Measure... 9 Control... 10 Report... 12 Additional Information... 15 About the Authors... 15 Tables Table 1 Design core tenets - Dell Energy Smart technologies... 5 Figures Dell PowerEdge SPECPower evolution... 4 PowerEdge PSU portfolio... 7 Power supply power loss across system loads... 8 PowerEdge power monitoring capabilities... 9 System-level power monitoring accuracy... 9 Power capping example... 10 EPR example with redundant (1+1) PSU configuration...11 PSU hot spare redundant PSU power dissipation... 12 idrac8 Power Monitoring GUI... 13 OpenManage Power Center power monitoring GUI... 14 3 Power and Cooling Innovations in Dell PowerEdge Servers

Executive summary Dell PowerEdge servers continue to evolve to deliver industry-leading value by reducing power consumption and providing intelligent power management features at the server and data center level. In this white paper, you will learn about enhancements to Dell s Energy Smart Architecture that are integrated into the latest Dell PowerEdge 13th generation servers. Introduction Dell s latest generation of PowerEdge servers build upon the Dell Energy Smart Architecture (DESA) introduced in previous generations of PowerEdge servers. DESA took the approach of including high power efficiency and intelligent power management as part of the platform s base features, enabling Dell customers to compute more while consuming less. DESA features offer high efficiency, intelligent power management capabilities, increased ROI, and new or improved data center usage models. Examples include: Power supply right sizing IDLE power efficiency Circuit breaker power capping High accuracy power monitoring Dell PowerEdge servers continue to evolve by significantly reducing power consumption with each new generation as illustrated in Figure 1. Dell PowerEdge SPECPower evolution 4 Power and Cooling Innovations in Dell PowerEdge Servers

While this white paper focuses on highlighting the DESA features in Dell PowerEdge servers, visit the Dell Power and Cooling Technologies page 1 for additional information on values, strategy, implementation, components, and best practices. Dell s Energy Smart Architecture Dell s Energy Smart Architecture is comprised of four core tenets: design, measure, control, and report. New and enhanced Dell Energy Smart technologies have been developed for each of the four core tenets. The majority of these technologies are leveraged across the Dell PowerEdge 13th generation server portfolio (including rack, tower, and blade servers) to provide consistency and compatibility. Table 1 highlights some of the notable enhanced technologies found in Dell PowerEdge 13 th generation servers. Table 1 Design Design core tenets - Dell Energy Smart technologies Power supply Common form factor Extended Power Range for CPU transients High efficiency main and auxiliary power rails Right-sized for the system Hot Spare Smart Power Factor Correction Voltage regulator (VR) High efficiency Switching Phase shedding Configuration-based tuning Components Low voltage processors Low voltage DDR4 DIMMs SSDs Software RAID option HDDs with standby Thermal High-airflow chassis Optimized heat sinks Independent fan control Pulse width modulation fans Low power fans BIOS Processor P, C, T-states DDR4 frequency selection DDR4 CKE and self refresh Turbo Boost disable Board design Low-loss layout Low-loss materials Low-loss connectors Measure Temperature Ambient, exhaust Components: processor, chipset, DIMMs, hard drives, PCIe adapters, power supplies Power Amperage, BTUs, voltage, and watts High accuracy Components: power supplies, processor, memory, storage, I/O, fans Performance Processor utilization Memory throughput I/O throughput 1 Dell Power and Cooling Technologies: http://www.dell.com/en-us/work/learn/power-and-cooling-technologies 5 Power and Cooling Innovations in Dell PowerEdge Servers

Control BIOS Enhanced Active Power Controller (OS independent process power management) OS enabled processor power management System Profiles o Performance o Performance per Watt o Dense configuration Processor core disable Host LOM port disable External and internal USB port disable Unused component disable Firmware Data center electrical and thermal power capping Non-linear fan curve Adaptive thermal algorithm Closed loop thermal monitoring and throttling Dynamic DIMM 2x refresh System thermal power capping Management LOM port disable Memory VR phase shedding Dell OpenManage Remote power On/Off Power inventory/budget Staggered power on Remote power On/Off Right-size PSU protection Extended Power Range Physical Disk Power Management IDLE memory control Dell OpenManage Power Center Group level (rack, aisle, data center) power capping Report Dell idrac8 Node level power reporting: averages, peaks, real-time Node level reporting mechanisms include tables and graphs Node level alarms/alerts, including power cap not maintained Dell OpenManage Power Center Provides group level (rack, aisle, data center) reporting Group level power reporting: averages, peaks, real-time Group level reporting mechanisms include tables and graphs Group level alarms/alerts, including power cap not-maintained Design With the 12 th generation of Dell PowerEdge servers, Dell introduced a power supply (PSU) portfolio with a common form factor. This strategy has been carried over into the next generation, with new and enhanced designs for Dell PowerEdge 13 th generation servers. The common PSU form factor lets you helps you select from a rich set of PSU options for capacity, input (AC or DC), or efficiency. Figure 2 highlights the PSU options that are supported by the majority of the new 13 th generation PowerEdge server portfolio. Some value platforms also support a low-cost cabled PSU option. 6 Power and Cooling Innovations in Dell PowerEdge Servers

PowerEdge PSU portfolio 7 Power and Cooling Innovations in Dell PowerEdge Servers

The PowerEdge PSUs meet 80 PLUS efficiency requirements for Platinum level with an Energy Smart option to upgrade to Titanium level. Dell PowerEdge servers are equipped with industry-leading PSU efficiencies that meet 80 PLUS s most stringent Titanium efficiency requirements. Figure 3 highlights the reduced power dissipation benefits of right sizing and high efficiency of PowerEdge 86mm PSUs. Power supply power loss across system loads Power delivery efficiency is also improved through voltage regulator (VR) enhancements such as high efficiency design, intelligent phase shedding, and ability to tune operation for a given server configuration. PowerEdge servers support a software RAID option for storage configurations with four SATA HDDs or less. While hardware RAID support improves performance and robustness, there is a power penalty. Depending on your requirements, software RAID provides an excellent RAID alternative to reduce platform power consumption. 8 Power and Cooling Innovations in Dell PowerEdge Servers

Measure PowerEdge servers integrate a custom version of Intel Node Manager firmware, the product of a joint Dell and Intel development effort. Node Manager provides rich power monitoring capabilities, including system-level (PSU) and subsystem-level (processor, memory, I/O, storage, and fan) monitoring. Node Manager also provides sampling rates up to ten samples per second to improve accuracy of averaging and to enable faster response to extreme power transients. PowerEdge power monitoring capabilities Power monitoring accuracy on PowerEdge servers exceeds the EPA s ENERGY STAR certification requirements by 87%, and rivals many external high-cost power meters. System-level power monitoring accuracy Thermal monitoring capabilities include exhaust, power control unit (PCU), memory and additional component temperatures such as hard drives and PCIe adapters. The additional thermal monitoring provides pinpoint temperature information to the thermal algorithm for finely tuned control of the system thermals. 9 Power and Cooling Innovations in Dell PowerEdge Servers

Control Enhanced power control features designed into PowerEdge servers target power-capping, power efficiency, IDLE power, and deployment simplification. In addition to rich power monitoring capabilities, Dell s custom version of Intel s Node Manager provides sophisticated power capping capabilities to support various data center and platform usage models. Fast and intelligent, the Node Manager power-capping solution limits power utilization below the user-defined limit within one second, while optimizing performance within the power constraints. With PowerEdge servers, you can use power capping to limit server power consumption due to data center or rack electrical or thermal limitations. Examples of other usage models include: Control peak power usage during a defined time period to control billing rates Provisioning power to workloads based on an SLA that does not require fully configured capability Power cap due to power utilities mandating brownout energy consumption reduction Limiting power due to extreme outside temperature that limits the data center s cooling capability Power cap to protect the data center against power and thermal excursions (such as HVAC failure) Dell s OpenManage Power Center provides a one-to-many power management console that can be used to set group-level (rack, aisle, data center) power cap policies. This console provides a simple interface for managing the power consumption of PowerEdge servers in the data center. The idrac8 Enterprise license is required for power capping through the idrac8 GUI or OpenManage Power Center. Power Supply Maximum Input Power Power Cap Upper Bound Heavy Workload Heavy Workload Power Cap Enabled Input Power (Watts) Recommended Power Cap Range Short Excursion (<1s) User Defined Power Cap Power Cap Lower Bound Heavy Workload Power Capped to User Defined Limit Heavy Workload Performance Impacted Power Capped to User Defined Limit Power Cap Disabled Power Monitoring Reading Light Workload Medium Workload No Performance Impact Time Power capping example 10 Power and Cooling Innovations in Dell PowerEdge Servers

Dell s PSU right-sizing strategy to improve power efficiency and reduce costs greatly benefits from a PowerEdge server feature called Extended Power Range (EPR) which temporarily extends the output capability of the power supply. Under typical workloads, power consumption is well below the output capability of the PSU, but if the workload spikes power beyond the PSU capability, ultra-fast hardware protection power cap policies are triggered to reduce power consumption. Extended Power Range allows richer system configurations to be supported within the power constraints of a smaller PSU. EPR example with redundant (1+1) PSU configuration The PSU feature Hot Spare improves the operating efficiency of redundant PSU configurations for light to typical workloads by putting one of the PSUs in sleep state. At higher loads, the sleeping PSU autonomously wakes to optimize operating efficiency. Visit the Dell Power and Cooling Technologies page 2 to view a video demo of this feature. Figure 8 highlights the hot spare reduction in PSU power dissipation. 2 Dell Power and Cooling Technologies: http://www.dell.com/en-us/work/learn/power-and-cooling-technologies 11 Power and Cooling Innovations in Dell PowerEdge Servers

PSU hot spare redundant PSU power dissipation Dell s Active Power Controller (DAPC), which provides OS-independent processor power management, has been fine-tuned for next-generation Intel processors. DAPC intelligently manages Intel s Turbo Boost feature for a near-linear performance-per-watt response, compared to non-turbo Boost levels. DAPC allows workloads to utilize Turbo Boost when needed, providing an optimal balance between performance and power consumption. Other control features target IDLE power. DIMM IDLE power is minimized by supporting CKE power down and self-refresh features. Storage IDLE power is minimized by the Physical Disk Power Management feature; Dell hardware RAID controllers will spin down IDLE disks. These IDLE power controls complement other power delivery efficiencies at light loads and existing IDLE power controls (for example, P-states or C-states). System Profiles provide easy buttons for configuring a server for performance, performance-per-watt, or dense (conservative) configurations that adjust various BIOS performance, power, and RAS settings. The Dense configuration focuses on prioritizing RAS over performance and power for dense memory configurations. Available Thermal Profiles complement the System Profiles by providing options for Performance or Performance-per-Watt thermal control algorithms. These thermal controls let you set a maximum exhaust temperature or increase system fan speeds by a fixed offset for additional cooling to I/O slots. Report idrac8 s power reporting in the idrac webserver GUI includes a power cap alert function that alerts you when a user-defined power cap cannot be maintained. idrac8 also allows you to specify a power cap limit below the recommended range, and lets you know when the platform cannot maintain the specified limit. 12 Power and Cooling Innovations in Dell PowerEdge Servers

idrac8 Power Monitoring GUI OpenManage Power Center provides powerful group-level power reporting capabilities at the rack, aisle and data center levels. This one-to-many power management console provides a clean, easy-to-use interface for users to track power consumption throughout the data center. Like idrac8, Power Center provides an alert function when a group-level power cap cannot be maintained. idrac8 Express provides power monitoring capabilities for the idrac8 GUI and OpenManage Power Center. An idrac8 Enterprise license is required for power capping in the idrac8 GUI or in OpenManage Power Center. 13 Power and Cooling Innovations in Dell PowerEdge Servers

OpenManage Power Center power monitoring GUI 14 Power and Cooling Innovations in Dell PowerEdge Servers

Additional Information For additional details and information, see the following documents and resources available on Dell.com: Power Consumption Reduction: Hot Spare Power Consumption Reduction: High Efficiency Power Supplies Increasing Energy Efficiency through Modular Infrastructure Dell.com/PowerandCooling Dell.com/PowerCenter Dell.com/FreshAir About the Authors John Jenne is a Distinguished Engineer in the Dell Enterprise Product Group focused on Node Power across the Dell Server portfolio. John has previously held positions with Compaq, MaXXan Systems, and Newisys. He has a B.S. in Computer Engineering from Clemson University, an M.S.E.E. from the University of Houston, and currently holds 16 patents. Craig Klein is a Principle Engineer in the Dell Enterprise Product Group working on Node Power across the Dell Server portfolio. Craig has previously held positions with IBM, and Jabil Circuit. He has a B.S. in Electrical Engineering from Texas A&M University, and currently holds 148 patents. 15 Power and Cooling Innovations in Dell PowerEdge Servers