Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

Similar documents
Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

02/11/2015

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

Zelio Control-modular measurement and control relays 1

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

RM4JA32MW current measurement relay RM4-J - range A V AC DC

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

Contact protection relay

RM35TF V AC

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

RM4JA01F current measurement relay RM4-J - range ma V AC

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RM35LM33MW liquid level control relay RM35-L V AC/DC

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

02/11/2015

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE Product data sheet Characteristics. time delay relay for star-delta starter ms - 230/380 V AC - 1 contact. Main.

Signal Doublers. VariTrans A 20300

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RM4JA31M current measurement relay RM4-J - range ma V AC

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

Electronic timer CT-ERD.12

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

Zelio Control Measurement Relays Multifunction 3-phase supply control relays RM17T 00

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

Alarm Unit DG 3200 Control And Monitor Standard Signals

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

RE9RA21MW7 off-delay timing relay s V AC -

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

QUINT-PS/ 1AC/24DC/20/CO

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

Uninterruptible power supply - TRIO-UPS/1AC/24DC/

RE22R1AMR On-delay Timing Relay s 300h V AC/DC - 1C/O

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

TM3AI4 module TM3-4 analog inputs

PHOENIX CONTACT Features

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

RM17UB3. Price* : USD

Zelio Control - modular measurement and control relays 1 Speed control relays RM35 S

Electronic timer CT-ARS.11

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Electronic timer CT-ERS.21

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

MIC-2 MKII, Multi-instrument DATA SHEET

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

Electronic timer CT-AHD.22

TM3TI8T module TM3-8 inputs temperature

BOX TRANSDUCER SMALL SIZED AC TRANSDUCER 90 SERIES

RM4TA32 three-phase network control relay RM4-T - range V

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RMCN22BD Analog Converter ma - for Zelio Analog

Multifunction Transducer MT440

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

Data sheet... OMNIMATE Power - series BL/SL 7.62HP BLZ 7.62HP/04/180LR SN BK BX

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

RM4TR31 three-phase network control relay RM4-T - range V

Voltage Transducer UMT516 / MT516

TM3TI4 module TM3-4 inputs temperature

QUINT-PS/24DC/48DC/ 5

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

MINI MCR-SL-UI-REL(-SP)

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

DEK-OV- 5DC/ 24DC/ 3. Extract from the online catalog. Order No.:

QUINT-PS/ 1AC/24DC/ 5

Transcription:

-CMT-10-AO-RC-S [!-] General ordering data Type -CMT-10-AO-RC-S Order No. 1510470000 Version Current-measuring transducer GTIN (EAN) 4050118319583 Qty. 1 pc(s).

-CMT-10-AO-RC-S Technical data Dimensions and weights Length 119.2 mm Width 22.5 mm Depth 113.6 mm Weight 180 g Net weight 158 g Temperatures Humidity 5...95 %, no condensation Operating temperature -25 C...60 C Storage temperature -40 C...85 C Probability of failure MTTF 158 Years Input Input frequency AC: 15 700 Hz Output Accuracy < 0.5 % of end value Max. switching voltage, AC 250 V Step response time < 220 ms (10...90 %) Temperature coefficient 200 ppm/k General data Configuration DIP switch and potentiometer, for thresholds (overcurrent undercurrent), delay and hysteresis Galvanic isolation 4-way isolator;, between input output supply relay Humidity 5...95 %, no condensation Mounting rail TS 35 Step response time < 220 ms (10...90 %) Supply voltage 16,8 V 31,2 V Temperature coefficient 200 ppm/k Weight 180 g Insulation coordination EMC standards IEC 61010-1:2010, 3rd Edition, IEC 61010-2-201:2013, 1st Edition, UL 61010-1:2012, Impulse withstand voltage 3rd Edition 6.4 kv (1.2/50 µs) Pollution severity 2 Rated voltage 300 V AC rms Standards IEC 61010-2-201:2013, Surge voltage category 1st Edition, UL 61010-1 III Output (analogue) Load resistance current [output analogue] Output current [output analogue] Type (analogue output) 600 Ω adjustable, 0...20 ma, 4...20 ma, -20 +20 ma Voltage and current output (configurable) Load resistance voltage [output analogue] 10 kω Output voltage [output analogue] adjustable, 0(1)...5 V, 0(2)...10 V, -5 +5 V, -10... +10 V

-CMT-10-AO-RC-S Technical data Output (digital) Type Rated switching current Relay, 1 CO contact, Open or closed-circuit principle, with alarm delay time (configurable) 0 s 2 s 5 s 10 s 6 A Max. switching voltage, AC 250 V Connection data Wire cross-section, solid, min. 0.5 mm² Wire cross-section, solid, max. 2.5 mm² Classifications ETIM 5.0 EC002048 ETIM 6.0 EC002048 eclass 6.2 27-21-09-02 eclass 7.1 27-21-09-02 eclass 8.1 27-21-09-02 eclass 9.0 27-21-09-02 Approvals ROHS Conform Downloads Package insert instruction sheet

-CMT-10-AO-RC-S Drawings dimensions

-CMT-10-AO-RC-S Drawings

-CMT-30-AO-RC-S [!-] General ordering data Type -CMT-30-AO-RC-S Order No. 1510540000 Version Current-measuring transducer GTIN (EAN) 4050118319590 Qty. 1 pc(s).

-CMT-30-AO-RC-S Technical data Dimensions and weights Length 119.2 mm Width 22.5 mm Depth 113.6 mm Weight 180 g Net weight 158 g Temperatures Humidity 5...95 %, no condensation Operating temperature -25 C...60 C Storage temperature -40 C...85 C Probability of failure MTTF 158 Years Input Input frequency AC: 15 700 Hz Output Accuracy < 0.5 % of end value Max. switching voltage, AC 250 V Step response time < 220 ms (10...90 %) Temperature coefficient 200 ppm/k General data Configuration DIP switch and potentiometer, for thresholds (overcurrent undercurrent), delay and hysteresis Galvanic isolation 4-way isolator;, between input output supply relay Humidity 5...95 %, no condensation Mounting rail TS 35 Step response time < 220 ms (10...90 %) Supply voltage 16,8 V 31,2 V Temperature coefficient 200 ppm/k Weight 180 g Insulation coordination EMC standards IEC 61010-1:2010, 3rd Edition, IEC 61010-2-201:2013, 1st Edition, UL 61010-1:2012, Impulse withstand voltage 3rd Edition 6.4 kv (1.2/50 µs) Pollution severity 2 Rated voltage 300 V AC rms Standards IEC 61010-2-201:2013, Surge voltage category 1st Edition, UL 61010-1 III Output (analogue) Load resistance current [output analogue] Output current [output analogue] Type (analogue output) 600 Ω adjustable, 0...20 ma, 4...20 ma, -20 +20 ma Voltage and current output (configurable) Load resistance voltage [output analogue] 10 kω Output voltage [output analogue] adjustable, 0(1)...5 V, 0(2)...10 V, -5 +5 V, -10... +10 V

-CMT-30-AO-RC-S Technical data Output (digital) Type Rated switching current Relay, 1 CO contact, Open or closed-circuit principle, with alarm delay time (configurable) 0 s 2 s 5 s 10 s 6 A Max. switching voltage, AC 250 V Connection data Wire cross-section, solid, min. 0.5 mm² Wire cross-section, solid, max. 2.5 mm² Classifications ETIM 5.0 EC002048 ETIM 6.0 EC002048 eclass 6.2 27-21-09-02 eclass 7.1 27-21-09-02 eclass 8.1 27-21-09-02 eclass 9.0 27-21-09-02 Approvals ROHS Conform Downloads Package insert instruction sheet

-CMT-30-AO-RC-S Drawings dimensions

-CMT-30-AO-RC-S Drawings

-CMT-60-AO-RC-S [!-] General ordering data Type -CMT-60-AO-RC-S Order No. 1510440000 Version Current-measuring transducer GTIN (EAN) 4050118319620 Qty. 1 pc(s).

-CMT-60-AO-RC-S Technical data Dimensions and weights Length 119.2 mm Width 22.5 mm Depth 113.6 mm Weight 180 g Net weight 158 g Temperatures Humidity 5...95 %, no condensation Operating temperature -25 C...60 C Storage temperature -40 C...85 C Probability of failure MTTF 158 Years Input Input frequency AC: 15 700 Hz Output Accuracy < 0.5 % of end value Max. switching voltage, AC 250 V Step response time < 220 ms (10...90 %) Temperature coefficient 200 ppm/k General data Configuration DIP switch and potentiometer, for thresholds (overcurrent undercurrent), delay and hysteresis Galvanic isolation 4-way isolator;, between input output supply relay Humidity 5...95 %, no condensation Mounting rail TS 35 Step response time < 220 ms (10...90 %) Supply voltage 16,8 V 31,2 V Temperature coefficient 200 ppm/k Weight 180 g Insulation coordination EMC standards IEC 61010-1:2010, 3rd Edition, IEC 61010-2-201:2013, 1st Edition, UL 61010-1:2012, Impulse withstand voltage 3rd Edition 6.4 kv (1.2/50 µs) Pollution severity 2 Rated voltage 300 V AC rms Standards IEC 61010-2-201:2013, Surge voltage category 1st Edition, UL 61010-1 III Output (analogue) Load resistance current [output analogue] Output current [output analogue] Type (analogue output) 600 Ω adjustable, 0...20 ma, 4...20 ma, -20 +20 ma Voltage and current output (configurable) Load resistance voltage [output analogue] 10 kω Output voltage [output analogue] adjustable, 0(1)...5 V, 0(2)...10 V, -5 +5 V, -10... +10 V

-CMT-60-AO-RC-S Technical data Output (digital) Type Rated switching current Relay, 1 CO contact, Open or closed-circuit principle, with alarm delay time (configurable) 0 s 2 s 5 s 10 s 6 A Max. switching voltage, AC 250 V Connection data Wire cross-section, solid, min. 0.5 mm² Wire cross-section, solid, max. 2.5 mm² Classifications ETIM 5.0 EC002048 ETIM 6.0 EC002048 eclass 6.2 27-21-09-02 eclass 7.1 27-21-09-02 eclass 8.1 27-21-09-02 eclass 9.0 27-21-09-02 Approvals ROHS Conform Downloads Package insert instruction sheet

-CMT-60-AO-RC-S Drawings dimensions

-CMT-60-AO-RC-S Drawings