Agilent OpenLAB Chromatography Data System (CDS) ChemStation Edition

Similar documents
Release Note for Agilent LC and CE Drivers Revision A SR1

Release Note for Agilent LC and CE Drivers Revision A.02.19

Release Note for Agilent LC and CE Drivers Revision A.02.16

Release Note for Agilent LC and CE drivers Revision A.02.14

Release Note for Agilent LC and CE Drivers Revision A.02.17

Agilent OpenLAB CDS. ChemStation Edition Instrument Configuration. Guide. Agilent Technologies

Agilent OpenLAB Chromatography Data System

Release Note for Agilent LC and CE Drivers Revision A.02.15

Agilent HPLC System Firmware Bulletin

Agilent Instrument Control Framework (ICF) Update A Driver Update 1 (DU1) Hot Fix 2 (HF2)

Release Notes for Agilent Drivers for Thermo Scientific Chromeleon 7 (Rev. 1.1)

Agilent HPLC System Firmware Bulletin

Agilent OpenLAB Chromatography Data System (CDS)

Firmware Update Guide. Agilent 1200 Infinity LC Systems

Agilent OpenLAB CDS Waters Alliance HPLC Instrument Control Add-On. Installation, Upgrade and Migration Guide

Agilent Instrument Control Framework A for Agilent LC/CE and GC Instruments in Non-Agilent Chromatography Data Systems Release Notes

Agilent 1260 Infinity Purification Solution

Agilent OpenLAB Chromatography Data System

Agilent OpenLAB Chromatography Data System (CDS)

Agilent OpenLAB Chromatography Data System (CDS)

Agilent ICF Support v3.0

Agilent OpenLAB Chromatography Data System

Agilent 1290 Infinity with ISET

Agilent OpenLAB Chromatography Data System (CDS)

Agilent Instrument Control Framework for Agilent LC/CE and GC instruments in Non-Agilent Chromatography Data Systems A.02.

Agilent OpenLAB. Data Store. Backup and Restore Guide

Agilent N2739A 1000 Series Oscilloscope Rack Mount Kit

Agilent OpenLAB Chromatography Data System (CDS)

Agilent OpenLab CDS ChemStation Edition

Agilent CSV Export Utility

Agilent OpenLAB CDS. Version 2.2. Release Notes. OpenLAB CDS Release Notes 1

Agilent Lab Advisor. IT Administrator's Guide. Agilent Technologies

Agilent OpenLAB. Data Store. Maintenance Guide

Agilent OpenLAB Chromatography Data System (CDS)

Setting up a LAN Instrument Network. Installation Guide

OpenLAB CDS ChemStation Edition

Agilent Dissolution Tester Driver

Firmware Guide. Keysight PXIe Chassis Family

Agilent OpenLAB Data Analysis Upload Download Tool. User s Guide

Agilent ChemStation Plus

Agilent OpenLAB ECM Intelligent Reporter

Agilent 1290 Infinity 2D-LC-Solution

Agilent G2721AA/G2733AA

Agilent LC Firmware. Background information. Status: August 2017

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit

Agilent OpenLAB Chromatography Data System (CDS)

Agilent 7890 Series Gas Chromatograph

BenchCel Workstations Software

Agilent EZChrom SI. Startup Guide

Agilent 1290 Infinity with ISET

Agilent Series Logic Analysis System

Agilent G1369B LAN Interface

86100 Series Infiniium DCA Oscilloscope

Agilent E2094M IO Libraries

Agilent 1200 Infinity Series High Dynamic Range Diode Array Detector Solution

Agilent HPLC System Firmware Bulletin

Agilent ChemStation Plus

Agilent OpenLab CDS ChemStation Edition

Agilent OpenLAB Data Store. Maintenance Guide

Agilent Technologies. Connectivity Guide. USB/LAN/GPIB Interfaces. Agilent Technologies

Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit

Keysight E7515A UXM Firmware Update Tool

Agilent OBSAI Protocol Tester

Agilent ChemStation for UV-visible Spectroscopy

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit

Secure Workstation for OpenLAB CDS ChemStation Edition User's Guide

Agilent OpenLAB Data Store Administration. Guide for Administrators

Keysight 11878A 50 Ohm 3.5 mm Adapter Kit

Microscan Barcode Reader

EZChrom Elite Compact. What s New in EZChrom Elite Compact Service Pack 2

Getting the most from your Agilent Instruments: New Advancements in OpenLAB CDS Instrument Control

Keysight N108xA-Series IEEE Ethernet KR/CR Compliance and Debug Application

EZChrom Elite Supported Modules and Firmware Updated 8/12/2009

Agilent Gb/s Serial BERT

Agilent ChemStation. ECM Interface Guide. Agilent Technologies

Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit

6820 GC (G1176A & G1180A) RS-232/TCP/IP

Agilent OpenLAB. Agilent Instrument Controller Installation and Configuration Guide

Impact Analysis for Software changes in OpenLAB CDS A.01.04

Agilent Technologies E5385A 100-Pin Probe

M8240BA Shimadzu LC Control Driver 1.51 for OpenLAB CDS

Agilent 1120 Compact LC Firmware

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable

Agilent HPLC System Firmware Bulletin

Agilent InfiniiMax II 1168A/1169A Probes

Keysight GUI Data Logger Software for U1731C, U1732C, and U1733C Handheld LCR Meter

Agilent OpenLAB CDS ChemStation Edition

Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz

Agilent Lab Advisor. User Manual. Agilent Technologies

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

Agilent HPLC System Firmware Bulletin

Keysight M9393A PXIe Vector Signal Analyzer

Agilent G1978B Multimode Source for 6410 Triple Quad LC/MS

AGILENT 1100/1200. Clarity Control Module. Code/Rev.: M060/70D Date: 10/5/2017

Agilent Instant Pilot G4208A

Agilent 89600B VSA. Software Installation Guide

Agilent E2943A/E2944A ATCA Probes for Advanced Switching Interconnect

Agilent GC Drivers A

Agilent N5410A Fibre Channel Automated Test Application

Setting Up Probes. Online Help

Transcription:

Agilent OpenLAB Chromatography Data System (CDS) ChemStation Edition Supported Instruments and Firmware Guide

Notices Agilent Technologies. 2010, 2011-2017 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Agilent Technologies, Inc. as governed by United States and international copyright laws. Manual Part Number M8301-90018 Rev B Edition 10/2017 Agilent Technologies, Inc. Software Revision This guide is valid for Agilent OpenLAB CDS ChemStation Edition Version C.01.08 Warranty The material contained in this document is provided as is, and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Agilent shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein. Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the separate agreement shall control. Technology Licenses The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license. Restricted Rights Legend If software is for use in the performance of a U.S. Government prime contractor subcontract, Software is delivered and licensed as Commercial computer software as defined in DFAR 252.227-7014 (June 1995), or as a commercial item as defined in FAR 2.101(a) or as Restricted computer software as defined in FAR 52.227-19 (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is subject to Agilent Technologies standard commercial license terms, and non- DOD Departments and Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR 52.227-19(c)(1-2) (June 1987). U.S. Government users will receive no greater than Limited Rights as defined in FAR 52.227-14 (June 1987) or DFAR 252.227-7015 (b)(2) (November 1995), as applicable in any technical data. Safety Notices CAUTION A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. WARNING A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. 2 Supported Instruments and Firmware Guide

Contents Contents OpenLAB CDS Driver Information 5 Minimum required Firmware 5 Operating Systems 5 Driver types 5 Instrument Communication Information OpenLAB CDS ChemStation Editions 6 Instrument LAN Interface Card 6 GPIB Compatibility 6 Agilent HPLC/LC Instrument and Firmware Compatibility 7 Support Statement 7 Recommended Firmware 7 Minimum required Firmware for Agilent HPLC/LC Modules 8 Agilent LC Sampling Systems 8 CTC PAL Autosamplers (Agilent and CTC) with LC 9 Agilent LC Pumps 9 Agilent LC Column Compartments 10 Agilent LC Detectors 10 Agilent LC Valves, Valve Drives and Clusters 12 Agilent LC Fraction Collectors 12 Agilent LC Other Module types 13 Agilent 218/SD1 PrepLC (formerly Varian Prep LC) 13 Agilent 1120 Compact LC Systems 13 Agilent 1220 Infinity LC Systems 14 Supported Agilent LC/MS 15 Supported Agilent CE 16 Agilent Capillary Electrophoresis 16 Agilent Analog-Digital Converter Information 17 Agilent A/D Converter 17 Agilent GC Instrument Compatibility 18 Agilent GC support 18 CDS Supported Instruments and Firmware Guide 3

Contents GC Sampler, Autosampler and Tray Compatibility 19 6850 ALS hardware 19 7650 ALS hardware: 19 7683B ALS hardware 19 7683A ALS hardware: 19 7693 ALS hardware 19 Headspace support with GC 20 Control of PAL sampler with GC 20 GC hardware not supported by the current CDS revision 21 Waters Drivers 22 M8505AA Waters LC Control 22 OpenLAB CDS ChemStation Workstation VL 23 Overview 23 OpenLAB CDS ChemStation Workstation VL rev. C.01.08 23 Supported Configurations for OpenLAB CDS ChemStation Edition VL Systems 23 A. Control of one Agilent GC 23 B. Control of one 1260 Infinity (II) LC instrument, configure with instrument type LC Core System. 24 C. Control of one 1120 Compact LC system, or one 1220 Infinity LC system configure with Instrument type 1220 LC System. 24 Classic Driver Support Information 26 In This Book 27 4 Supported Instruments and Firmware Guide

OpenLAB CDS Driver Information OpenLAB CDS Driver Information Minimum required Firmware Agilent recommends using the most recent firmware revisions in order to provide the highest level of system capability. Please visit http://www.agilent.com/en-us/firmwaredownload?whid=69761 to download the latest Agilent LC firmware. Drivers are forward compatible with respect to firmware, i.e. the firmware can be updated without the need of updating the driver or CDS. To check the firmware of your installed instrument do the following: In the ChemStation Edition Method and Run Control view: LC Instruments: In the menu go to Instrument > Revisions & Serial#s. GC Instruments: In the menu go to Instrument > Instrument Configuration. Select the GC under Selected Modules, click the configure button, then select the configuration tab. In the following sections this guide lists the instruments and modules compatible with the current version of OpenLAB CDS and list the minimum required firmware, that allows to run the instrument. The instrument driver and firmware versions listed have been verified to work with OpenLAB CDS ChemStation Edition version C.01.08. NOTE The minimum required firmware specified allows operation of the instrument with the data system, but preserves the minimal functionality of the stated firmware. Not all functionality introduced by more recent releases of instrument drivers and the associated firmware is available with previous versions. A firmware upgrade should be done if you face problems or want to add system functionality to your system. Operating Systems Unless otherwise noted all instrument drivers are supported on Windows 7 SP1 Enterprise and Professional (64-bit ) Windows 10 Enterprise and Professional (64-bit ) For more detail and support information on server operating systems please see OpenLAB CDS ChemStation Edition Requirements guide. Driver types Agilent OpenLAB CDS drivers are based on the RC.NET architecture. Information in this guide refers to this driver type, unless otherwise noted. For some instrument classes Classic Plus drivers are available with OpenLAB CDS ChemStation Edition (ELSD, CTC and Single Quad MS). The Classic Plus driver types can be combined with RC.NET drivers via their CIC ports. CDS Supported Instruments and Firmware Guide 5

Instrument Communication Information OpenLAB CDS ChemStation Edition NOTE On Agilent Instrument Controllers (AICs), OpenLAB CDS ChemStation Edition exclusively supports instruments and modules connected via LAN. GPIB, RS232, USB or any converter are not supported on AICs. Instrument LAN Interface Card Product Hardware Minimum required Firmware Revision Notes G1369C LAN Interface card B.06.40 CAN support for hosted modules/can slave (e.g. G1170A Universal Valve Drive) SW 7 and SW 8 must be in the OFF position 10/100BaseT G1369B LAN Interface card A.01.01 SW 7 and SW 8 must be in the OFF position 10/100BaseT G1369A LAN Interface card A.01.10 2 nd version Board revision C.03.00 firmware A.01.10 Supported with 35900E and GC 1 st version firmware A.01.05 Not Supported with GC and 35900E J4100A Jet Direct Card and 82357B USB /GBIB interface are not compatible with the current version of OpenLAB CDS ChemStation GPIB Compatibility Can be used with Classic drivers only! Product Minimum required Firmware Revision Support Statement / Comments 82350B Keysight I/O libraries ChemStation LC/MS. Not supported for GC instruments The Keysight I/O Libraries are not supported on Windows Server 2008 R2 nor Windows Server 2012; therefore, GPIB communication is not available for AICs. 6 Supported Instruments and Firmware Guide

Agilent HPLC/LC Instrument and Firmware Compatibility Support Statement Most Agilent LC Modules can be controlled by OpenLAB CDS ChemStation Edition using the most current LC driver. LC driver release A.02.18 has been tested with this revision and is installed by default with the software. Recommended Firmware Use the latest firmware set for Agilent LC instruments with Agilent OpenLAB CDS ChemStation Edition. The latest sets are 7.01, 6.50, and 6.30. Please visit the Agilent site LC Firmware News and Downloads for downloading the latest Agilent LC firmware. Firmware from Set 7.01 can be downloaded from http://www.agilent.com/en-us/firmwaredownload?whid=99818. You need to upgrade ALL existing modules to latest version only if a new LC module is added to the existing system (recommended) one of the existing modules requires an upgrade due to a bug fix solved with the latest release. NOTE LC and CE Firmware revisions are grouped into sets for each module or system. Firmware sets include just the latest firmware of each module. Modules combined into one LC instrument always need to have firmware from the same set. Firmware of one set is fully compatible with your CDS that supports this firmware set. However, if one module uses a firmware revision lower that the current firmware some functionality might not be supported. Do not mix firmware revisions from one set with older or newer sets. Firmware is not tested across set borders! For more information on downloading the current Firmware, please refer to the Agilent website: Firmware Update Tools & Procedures. For more details on the LC Driver and Firmware please refer to the Release Note for Agilent LC and CE drivers Revision A.02.18, available on the install media at Disk3\Docs\ENU. Please note that the LC Driver releases are independent from CDS Releases. OpenLAB CDS ChemStation Edition C.01.08 is shipped with LC driver release A.02.18, but may be compatible with later releases. If you want to use more recent driver revisions, please refer to the respective Release Note for Agilent LC and CE drivers delivered with the drivers for more information. CDS Supported Instruments and Firmware Guide 7

Agilent HPLC/LC driver information for Agilent OpenLAB CDS ChemStation Edition Minimum required Firmware for Agilent HPLC/LC Modules Some of the modules are supported with Firmware revisions lower than the ones available in the current Firmware set 7.01. For more information please check the following pages for the minimum required firmware revision. NOTE The minimum required firmware specified is tested to allow operation of the respective instrument with the data system, but preserves the minimal functionality of the stated firmware. Not all functionality introduced by more recent releases of instrument drivers and the associated firmware is available with minimum required FW versions! Agilent LC Sampling Systems Product Number Module Name Minimum required Firmware Revision G1313A 1100 Series Standard Autosampler A.06.10 G1329A 1100 Series Standard Autosampler A.06.10 G1329B 1260 Infinity Standard Autosampler A.06.10 G1367A 1100 Series Well-Plate Sampler A.06.31 G1367B 1200 Series High Performance Autosampler A.06.31 G1367C 1200 Series High Performance Autosampler SL A.06.31 G1367D 1200 Series High Performance Autosampler SL+ A.06.31 G1367E 1260 Infinity High Performance Autosampler A.06.32 G1373A Purge Kit (Includes G1156A 6Pos/7Port valve, cabinet top kit with rail, accessories and ChemStation SW, for use with 1200 wellplate sampler) A.06.56 G1377A 1260 Infinity High Performance Micro Autosampler A.06.12 G1389A 1100 Series Micro Thermostatted Autosampler A.06.10 G2256A 1260 Infinity Sample Capacity Extension n/a G2258A 1260 Infinity Dual-Loop Autosampler A.06.50 G2260A 1260 Infinity Preparative Autosampler (High flow) A.06.50 G4226A 1290 Infinity Autosampler A.06.31 G4303A 1260 Infinity SFC standard autosampler A.06.54 G4767A 1260 Infinity II SFC Multisampler D.07.13 G5667A 1260 Infinity Bio-inert High Performance Sampler A.06.32 G5668A 1260 Infinity II Bio-Inert Multisampler D.07.13 G7129A 1260 Infinity II Vialsampler D.06.76 G7129B 1290 Infinity II Vialsampler D.06.76 G7157A 1260 Infinity II Preparative Autosampler D.07.01 G7167A 1260 Infinity II Multisampler D.07.13 G7167B 1290 Infinity II Multisampler 8 Supported Instruments and Firmware Guide

Agilent HPLC/LC driver information for Agilent OpenLAB CDS ChemStation Edition CTC PAL Autosamplers (Agilent and CTC) with LC Product Number Module Name Minimum required Revision CTC Firmware Software. G4277A Agilent 1290 Infinity LC Injector HTS 4.3.0 B.01.08 G4278A Agilent 1290 Infinity LC Injector HTC 4.3.0 B.01.08 G4270-CTC CTC Analytics HTC PAL Injection System 1 2.5.2 (for legacy mainboard) 2.6.8 (for legacy mainboard) G4271-CTC CTC Analytics HTS PAL Injection System 1 4..3.0 (for new XT mainboard) B.01.08 Cycle Parameters in English Agilent LC Pumps Product Number Module Name G1310A 1200 Series Isocratic Pump A.06.10 G1310B 1260 Infinity Isocratic Pump A.06.32 G1311A 1200 Series Quaternary Pump 1 A.06.10 G1311B 1260 Infinity Quaternary Pump 1 A.06.32 G1311C 1260 Infinity Quaternary Pump VL 1 A.06.32 G1312A 1260 Infinity Binary Pump 1 A.06.10 G1312B 1260 Infinity Binary Pump SL 1 A.06.10 G1312C 1260 Infinity Binary Pump VL 1 A.06.32 G1361A 1260 Infinity Preparative Pump A.06.50 G1376A 1260 Infinity Capillary Pump A.06.10 G2226A 1260 Infinity Nanoflow Pump A.06.10 G4204A 1290 Quaternary Pump 1 B.06.50 G4220A 1290 Infinity Binary Pump 1 B.06.23 G4220B 1290 Infinity Binary Pump VL 1 B.06.43 G4302A 1260 Infinity SFC Binary Pump 1 A.06.10 G4782A 1260 Infinity II SFC Binary Pump D.07.13 G5611A 1260 Infinity Bio-inert Quaternary Pump 1 A.06.10 G5654A 1260 Infinity II Bio-inert Pump 1 D.07.01 G7104A 1290 Infinity II Flexible Pump B.06.71 Minimum required Firmware Revision G7104B Update of G7104A Supported when available G7104C 1260 Infinity II Flexible Pump D.07.20 G7110B 1260 Infinity II Isocratic Pump D.07.01 G7111A 1260 Infinity II Quaternary Pump VL 1 D.07.01 G7111B 1260 Infinity II Quaternary Pump 1 D.07.01 G7112B 1260 Infinity II Binary Pump 1 D.07.01 CDS Supported Instruments and Firmware Guide 9

Agilent HPLC/LC driver information for Agilent OpenLAB CDS ChemStation Edition G7120A 1290 Infinity II High Speed Pump B.06.71 G7161A 1260 Infinity II Preparative Binary Pump D.07.20 G7161B 1290 Infinity II Preparative Binary Pump D.07.20 1 Pump valve clusters are possible for marked pumps with up to 2 valves of type G1160A and/or G1170A Agilent LC Column Compartments Product Number Module Name Minimum required Firmware Revision G1316A 1260 Infinity Column Compartment (Thermostatted) A.06.10 G1316B 1200 Series Column Compartment SL A.06.10 G1316C 1290 Infinity Column Compartment (Thermostatted) 2 A.0630 G7116A G7116B 1260 Infinity II Multicolumn Thermostat (MCT) (firmware for host module in brackets) 1290 Infinity II Multicolumn Thermostat (MCT) (firmware for host module in brackets) G7130A Integrated Column Compartment ICC (option for G7129 A/B) D.06.75 Valve Thermostat Cluster with multiples of these modules: A combination of G7116B, G1170A and G1316C as valve or column hosts and G1316A/B and G7130A as column host D.07.01 (B.07.01/D.07.01) D.06.75 (B.06.75/D.06.75) C.06.75 (B.06.75/D.06.75) 2 Cluster with up to three G1316C with integrated 8pos/9port valves (products G4230A/B). Minimum two G1316C TCCs. The third TCC can be a G1316A, B or C. Agilent LC Detectors Product Number Module Name Minimum required Firmware Revision VWD G1314A 1100 Series Variable Wavelength Detector A.06.10 G1314B 1260 Infinity Variable Wavelength Detector VL A.06.10 G1314C 1260 Infinity Variable Wavelength Detector VL+ A.06.10 G1314D 1200 Series Variable Wavelength Detector B.06.32 G1314E 1290 Infinity Variable Wavelength Detector B.06.32 G1314F 1260 Infinity Variable Wavelength Detector B.06.32 G7114A 1260 Infinity II Variable Wavelength Detector D.07.01 G7114B 1290 Infinity II Variable Wavelength Detector D.06.70 MWD G1365A 1100 Series Multiple Wavelength Detector A.06.10 G1365B 1200 Series Multiple Wavelength Detector A.06.10 G1365C 1260 Infinity Multiple Wavelength Detector B.06.30 G1365D 1260 Infinity Multiple Wavelength Detector VL B.06.30 G7165A 1260 Infinity II Multiple Wavelength Detector D.07.01 10 Supported Instruments and Firmware Guide

Agilent HPLC/LC driver information for Agilent OpenLAB CDS ChemStation Edition FLD G1321A 1100 or 1200 Fluorescence Detector A.06.10 G1321B 1260 Infinity Fluorescence Detector Spectra A.06.32 G1321C 1260 Infinity Fluorescence Detector A.06.54 G7121A 1260 Infinity II Fluorescence Detector D.07.01 G7121B 1260 Infinity II Fluorescence Detector Spectra D.07.01 DAD G1315A 1100 Series Diode Array Detector A.06.10 G1315B 1200 Series Diode Array Detector A.06.10 G1315C 1200 Series Diode Array Detector VL+ B.06.30 G1315D 1200 Series Diode Array Detector VL B.06.30 G4212A 1290 Infinity Diode Array Detector B.06.30 G4212B 1260 Infinity Diode Array Detector B.06.30 G4212A/B HDR-DAD Cluster 2x G4212A or 2x G4212B or a combination of 1x G4212A and 1x G4212B B.06.57 G7115A 1260 Infinity II DAD WR D.07.01 G7117A 1290 Infinity II Diode Array Detector FS D.06.70 G7117B 1290 Infinity II Diode Array Detector D.06.70 G7117C 1260 Infinity II Diode Array Detector HS D.07.01 G7117A/B HDR-DAD Cluster RID 2x G7117A or 2x G7117B or a combination of 1x G7117A and 1x G7117B D.06.70 G1362A 1260 Infinity Refractive Index Detector A.06.10 G7162A 1260 Infinity II Refractive Index Detector D.06.76 G7162B 1290 Infinity II Refractive Index Detector D.06.76 ELSD G4218A 1260 Infinity Evaporative Light Scattering Detector 1.4 Classic Plus (English Driver only) 3 G4260A 1260 Infinity 380 Evaporative Light Scattering Detector 25.00 3 G4261A 1290 Infinity 385 Evaporative Light Scattering Detector 25.00 3 G4260B 1260 Infinity II Evaporative Light Scattering Detector 32.06 3 G4261B 1290 Infinity Evaporative Light Scattering Detector 32.06 3 G7102A 1290 Infinity II Evaporative Light Scattering Detector 32.06 3 3 English only, RS232 not supported on AIC CDS Supported Instruments and Firmware Guide 11

Agilent HPLC/LC driver information for Agilent OpenLAB CDS ChemStation Edition Agilent LC Valves, Valve Drives and Clusters Product Number Module Name Minimum required Firmware Revision G1156A 1200 Series 6 Position / 7 Port Valve (400 bar) The G1156A valve is not configurable in ChemStation, neither Classic, nor RC.NET. It requires an ALS G1157A 1200 Series 2 Position / 10 Port Valve A.06.02 G1158A 1200 Series 2 Position / 6 Port Valve A.06.02 G1158B 1200 Series 2 Position / 6 Port Valve (600bar) A.06.02 G1159A 1200 Series 6 Position Selection Valve A.06.02 G1160A 1100 Series Multiple Purpose Switching Valve (12 Position / 13 Port) A.06.02 G1162A 1200 Series 2 Position/ 6 Port Micro Valve A.06.02 G1163A 1200 Series 2 Position/ 10 Port Micro Valve A.06.02 G1170A 1290 Infinity Valve Drive (firmware for host module in brackets) C.06.40 (B.06.40/D.06.60) G4734A hosted valve: 6-Column-selector requires valve host G1170A or G7116A/B Valve Thermostat Cluster The Valve Thermostat Cluster is a combination of G7116B, G1170A and G1316C as valve or column hosts and G1316A/B and G7130A as column hosts. (firmware for host module in brackets) C.06.75 (B.06.75/D.06.75) Agilent LC Fraction Collectors Product Number Module Name G1364A 1100 Series Automatic Fraction Collector 4 A.06.53 G1364B 1260 Infinity Fraction Collector (preparative-scale) 4 A.06.53 G1364C 1260 Infinity Fraction Collector (analytical-scale) 4 A.06.53 G1364D 1100 Series Micro Fraction Collector A.06.53 G1364E 1260 Fraction Collector D.07.20 G1364F 1260 Fraction Collector D.07.20 G5664A 1260 Infinity Bio-inert fraction collector AS 4 A.06.53 G5664B 1260 Infinity II Bio-inert Fraction Collector D.07.20 G7159B 1290 Infinity II Preparative Open-Bed Fraction Collector D.07.10 Minimum required Firmware Revision G7166A Fraction Collector cluster 1260 Infinity II Preparative Valve-Based Fraction Collector (firmware for host module in brackets) Any combination of up to three G1364A/B/C or G5664A plus a fourth G1364A/B/C or G5664A for recovery can be clustered. Multiple single Fraction Collectors are not supported. G1364 E /F can be clustered with a G7166A or the same module type for recovery collection. G7159 can be clustered with a G7166A for Recovery C.07.10 (B.07.10/D.07.10) 12 Supported Instruments and Firmware Guide

Agilent HPLC/LC driver information for Agilent OpenLAB CDS ChemStation Edition Agilent LC Other Module types Product Number Module Name G1390A 1100 Series Universal Interface Box (UIB) A.06.02 G1390B G2229A 1200 Infinity Universal Interface Box II (firmware for host module in brackets) Infinity Nanoflow LC System: Includes Nanoflow pump, micro degasser, micro well-plate sampler, handheld controller (G1377A + G2226A) Minimum required Firmware Revision C.06.53 (B.06.53/D.06.60) A.06.02 G2254A 1260 Automation Interface A.06.02 G4227A 1290 Infinity Flexible Cube (firmware for host module in brackets) G4240A 1260 Chip Cube MS Interface A.06.36 G4301A 1260 Infinity Analytical SFC System A.03.09 C.06.52 (B.06.52/D.06.60) G7170B 1290 Infinity II MS Flow Modulator (firmware for host module in brackets) C.07.20 (B.07.20/D.07.20) Agilent 218/SD1 PrepLC (formerly Varian Prep LC) Product Number Module Name Communications Minimum required Firmware Revision Agilent 210 Pump RS232 1.73 rev C Agilent 218 Pump RS232 1.1 rev B Agilent SD1 Pump RS232 2.2 Agilent 325 UV/VIS Detector LAN 2.07 Agilent 410 Autosampler RS232 2.07 Agilent 440 Fraction Collector RS232 1.31 Agilent 1120 Compact LC Systems Product Number Module Name Communications Minimum required Firmware Revision G4286A 1120 Compact LC, Isocratic pump TCP/IP B.06.50 G4287A 1120 compact LC. Isocratic with Oven and ALS TCP/IP B.06.50 G4288A 1120 Compact LC, Gradient TCP/IP B.06.50 G4289A 1120 Compact LC, Gradient with oven TCP/IP B.06.50 G4290A 1120 Compact LC, Gradient with oven and ALS TCP/IP B.06.50 CDS Supported Instruments and Firmware Guide 13

Agilent HPLC/LC driver information for Agilent OpenLAB CDS ChemStation Edition Agilent 1220 Infinity LC Systems Product Number Module Name Minimum required Firmware Revision G4286B 1220 Infinity LC System Isocratic, Man. Inj., VWD, 600 bar B.06.50 G4287B 1220 Infinity LC Isocratic, ALS, TCC, VWD, 600 bar B.06.50 G4288B 1220 Infinity LC Gradient, Man. Inj., VWD, 600 bar B.06.50 G4289B 1220 Infinity LC Gradient, ALS, TCC, VWD, 600 bar B.06.50 G4290B 1220 Infinity LC Gradient, ALS, Man. Inj., TCC, VWD, 600 bar B.06.50 G4291B 1220 Infinity LC Isocratic, Man. Inj., TCC, VWD, 600 bar B.06.50 G4292B 1220 Infinity LC Isocratic, ALS, VWD, 600 bar B.06.50 G4293B 1220 Infinity LC Gradient, ALS, VWD, 600 bar B.06.50 G4294B 1220 Infinity LC Gradient, ALS, TCC, DAD, 600 bar B.06.50 G4288C 1220 Infinity LC System VL, Gradient, Man. Inj. VWD, 400 bar B.06.50 G4289C 1220 Infinity LC System VL, Gradient, TCC, Man. Inj. VWD, 400 bar B.06.50 G4290C 1220 Infinity LC System VL, Gradient, ALS, TCC, VWD, 400 bar B.06.50 G4293C 1220 Infinity LC System VL, Gradient, ALS, VWD, 400 bar B.06.50 G4294B 1220 LC Infinity Gradient System B.06.50 14 Supported Instruments and Firmware Guide

Agilent CE driver information for Agilent OpenLAB CDS ChemStation Supported Agilent LC/MS Requires Keysight I/O libraries Model Module Type Supported Firmware Supported Driver Type Communications G6110A 6100 Series Single Quadrupole LC/MS System 3.02.48 Classic Plus LAN G6120A G6120B 6100 Series Single Quadrupole LC/MS System 3.02.48 3.02.49 Classic Plus LAN G6125B G6130A G6130B G6135B G6140A G6150B 6100 Series Single Quadrupole LC/MS System 6100 Series Single Quadrupole LC/MS System 6100 Series Single Quadrupole LC/MS System 6100 Series Single Quadrupole LC/MS System 6100 Series Single Quadrupole LC/MS System 3.02.50 Classic Plus 3.02.48 Classic Plus LAN 3.02.50 Classic Plus 3.02.48 Classic Plus LAN 3.02.48 Classic Plus LAN G7100A CE/MS 4 B.07.01 or higher When configured as CE-MS system, workstation and networked workstation only. 4 If Agilent LC/MS is controlled in conjunction with the Agilent 3D Capillary Electrophoresis system, no additional instrument is supported on that PC system CDS Supported Instruments and Firmware Guide 15

Agilent LC/MS driver information for Agilent OpenLAB CDS ChemStation Edition Supported Agilent CE NOTE Configure using Instrument Type Agilent 7100 CE System. Agilent Capillary Electrophoresis Product Number Module Name Minimum required Firmware Revision G7150A G7100 Capillary Electrophoresis II B.07.01 or higher G7151A Diode Array Detector for CE II B.06.26 35900E A/D converter (RC.net only, LAN only!) E.01.02 Agilent G7100 CE/MS B.07.01 or higher MS: 6100 Series FW 3.02.42 or higher Special Notes: 1. When OpenLAB CDS ChemStation Edition is used to control an Agilent 3D Capillary Electrophoresis system, no additional instruments are supported on the PC system. 2. When OpenLAB CDS ChemStation Edition is used to control the Agilent LC/MS, in conjunction with the Agilent 3D Capillary Electrophoresis system, no additional instruments are supported on the PC system (the one PC controls only the CE and MS system). 3. CE/MS systems are supported with OpenLAB CDS ChemStation Edition when configured as CE-MS system, workstation and networked workstation only. Coinstallation is possible, but no Co-execution Agilent G1600 CE Familiy and G1600 CE/MS cannot be controlled with ChemStation C.01.08. 16 Supported Instruments and Firmware Guide

Agilent A/D information for Agilent OpenLAB CDS Agilent Analog-Digital Converter Information Agilent A/D Converter Instrument Supported Firmware Version (minimum) Communications Agilent 35900E Dual Channel Interface E.01.02 TCP/IP, RC.net only 35900E Series II E.02.04.40 3rd and 4th Signal is supported with RC.net GC driver Agilent 35900E RC.Net driver supports separating the channels between 2 instruments on an AIC distributed system. CDS Supported Instruments and Firmware Guide 17

Agilent GC driver information for Agilent OpenLAB CDS Agilent GC Instrument Compatibility Only RC.Net drivers are supported for Agilent GC instrument. Agilent recommends using the latest firmware revision in order to provide the highest level of system capability. Refer to latest Hardware Service Notes for latest firmware available. After an upgrade, the 68xx series GC must be re-configured to use the RC.NET driver in Agilent OpenLAB Control Panel. NOTE Communication is handled via LAN. GCs using GPIB must update to LAN. Agilent GC support Product Number Description Notes G3950A G3952A G3953A G3440A G3445A G3440B G3445B Intuvo 9000 GC system 7890A 7890B 7683 ALS family not supported G4350A 7820A Backflush and Easy SamplePrep are not supported with 7820 G1530N G1540N G1530A G1540A 6890N 6890A 6890Plus G2629A 6850 Handheld Controller Not tested Manual inlets and manual detectors are not supported Manual inlets and manual detectors are not supported G2630A 6850 serial #<= US00003200 6850 serial # >= US10243001 Manual inlets and manual detectors are not supported G3581A 490 Micro GC TCP-IP. For legacy mainboard: minimum required FW is 1.40 G3582A 490 Micro GC Analyzer TCP-IP 18 Supported Instruments and Firmware Guide

Agilent GC driver information for Agilent OpenLAB CDS GC Sampler, Autosampler and Tray Compatibility 6850 ALS hardware Instrument Model Notes Injector G2880A 7650 ALS hardware: Instrument Model Notes Injector G4567A 7683B ALS hardware Instrument Model Notes Controller G2912A 7683B ALS Controller for 6890 7683B Injector G2913A Tray BCR/Mixer G2614A G2615A 7683A ALS hardware: Instrument Model Notes 7683A Injector G2613A Tray BCR/Mixer G2614A G2615A ALS Controller G2612A 7683/6890 ALS interface board 7693 ALS hardware Instrument Model Notes 7693 Injector G4513A 7693 Tray G4514A BCR/Mixer G4515A ALS Controller Board G4516A 6890 Plus only ALS Controller G4517A 6890A only CDS Supported Instruments and Firmware Guide 19

Agilent GC driver information for Agilent OpenLAB CDS Headspace support with GC NOTE Communication is handled via LAN. Instrument Model Firmware Software Notes 7697A Headspace G4556A, A.01.08 B.01.07.2 License number no longer required for G4557A installation. G1888 Headspace G1888A A.01.10 B.01.07.2 Note: The software registration packet will still include a license number. Control of PAL sampler with GC Instrument Model Firmware Software Notes Agilent PAL-xt CTC Sampler Agilent PAL-3 CTC Autosampler G6501B, G6502B, G6509B G7366A, G7367A, G7368A, G7370A 4.3.0 B.01.08 2.4.2 A.01.04 PAL-xt method parameters are available to Intelligent Reporting beginning in PAL Software Rev. B.01.07. Note: License number no longer required for installation. The software registration packet will still include a license number. The CTC PAL-3 method parameters are available to Intelligent Reporting since PAL Software rev. A.01.01. Note: License number no longer required for installation. The software registration packet will still include a license number. 20 Supported Instruments and Firmware Guide

Agilent GC driver information for Agilent OpenLAB CDS GC hardware not supported by the current CDS revision Instrument Notes 5890A 5890 Series II, 4890D The 5890 driver is not tested. There will be no new updates or hotfixes for the 5890 GC driver. 35900C/D 19405A/B Sampler Event Control Module (SECM) G1289B, G1290B, (7694B); G1883A (7694E) Headspace The 7694B headspace was last supported with OpenLAB CDS ChemStation C.01.05 with the Headspace software rev B.01.04. 7673A family (18593A, 18594A, 18596A) 7673B family (18593B, 18594B, 18596B) 7673C family (G1512A, G1513A, 18596C) G2403A LAN/RS232 converter G1176A, G1180A (6820 GC) G1926A 3000 micro GC, M200, M400 G7360A Archon Purge and Trap Auto sampler for Water only G7361A The Archon Purge and Trap Auto sampler for Needle Sparge WorkBench Tray (G8130A) CDS Supported Instruments and Firmware Guide 21

Waters LC Control Waters Drivers M8505AA Waters LC Control NOTE This Driver is initially not supported! Expected availability: December 2017 Waters LC Control includes the following Drivers: Waters Acquity A.01.02 Waters Alliance 6.2.1.17 English language only Please consult the respective driver user guides and service documentation for further information. For further information on the supported instruments, please contact your local Agilent Sales representative or check in SubscribeNet. 22 Supported Instruments and Firmware Guide

OpenLAB CDS VL Support Information OpenLAB CDS ChemStation Workstation VL Overview OpenLAB CDS ChemStation Edition offers a VL version for Workstations. It provides the full functionality of the Workstation configuration while restricting instrument control. The OpenLAB CDS ChemStation Workstation VL license allows the control of one LC or GC instrument only, and restricts the use of the instruments to standard modules. LC-MS configurations are not supported. The supported modules and firmware options for VL Systems are listed in more detail below. OpenLAB CDS ChemStation Workstation VL rev. C.01.08 Allows control of one of the below: One 1260 Isocratic Infinity (II) LC system, or one 1260 Quaternary Infinity (II) LC system with selected 1260 Infinity (II) LC modules (use instrument type Agilent LC Core System ). 1290 series LC systems are not compatible with VL. One Agilent 1220 Infinity LC system or one 1120 Compact LC system (use Agilent 1220 LC System ). Control of supplemental Infinity LC modules is supported for all LC modules with the exception of modular pumps. One 7820A GC, or one 490 Micro GC. Supported Configurations for OpenLAB CDS ChemStation Workstation VL For latest firmware information, please refer to the respective driver release notes, or to the tables for the OpenLAB CDS ChemStation full version in this guide. A. Control of one Agilent GC The appropriate instrument drivers are bundled with the instrument hardware. Table 1 Control supported with OpenLAB CDS ChemStation Workstation VL Module Name 7820A Agilent 490 Micro GC Product Number G4350B G3581A CDS Supported Instruments and Firmware Guide 23

OpenLAB CDS VL Support Information B. Control of one 1260 Infinity (II) LC instrument, configure with instrument type LC Core System. The modules listed in Table 3 below may be part of the 1260 Infinity LC instrument. Table 3 Agilent LC Core System modules Module Name Product Number 1200 Quaternary Pump G1311A 1260 Quaternary Pump G1311B, 1260 Quaternary Pump VL G1311C 1260 Infinity II Pumps: Isocr Quat Quat G7110B G7111A G7111B 1260 Column Compartment G1316A 1260 Infinity II Multicolumn Thermostat G7116A 1260 Autosampler G1329B (may add G1330B Thermostat), 1260 Infinity II Vialsampler G7129A (includes ICC: G7130A) 1260 Diode Array Detectors DAD G1315C, G1315D, G4212B 1260 Multiple Wavelength Detectors. MWD G1365C, G1365D 1260 Variable Wavelength Detectors. VWD G1314B, G1314C, G1314D, G1314F 1260 Refractive Index Detector RID G1362A, G7162A 1260 Fluorescence Detector FLD G1321B, G1321C 1260 Infinity II detectors: VWD DAD FLD MWD G7114A G7115A, G7117C G7121A, G7162A G7165A 1200 UIB II G1390B C. Control of one 1120 Compact LC, or one 1220 Infinity (II) LC system configure with Instrument type 1220 LC System. The appropriate instrument drivers are bundled with the instrument hardware. Table 4 OpenLAB CDS ChemStation Workstation VL compatibility with Agilent 1120 Compact LC Product Number G4286A G4287A G4288A G4289A Module Type 1120 Compact LC, Isocratic 1120 Compact LC Isocratic with Oven and ALS 1120 Compact LC, Gradient 1120 Compact LC, Gradient with oven 24 Supported Instruments and Firmware Guide

OpenLAB CDS VL Support Information G4290A G1321A G1362A G4218A G4260A G4261A G4260B G4261B 1120 Compact LC Gradient with oven and ALS 1100/1200 FLD 1100/1200 RID 1100/1200 ELSD ELSD 380 Detector ELSD 385 Detector ELSD 1260 Infinity Detector ELSD 1290 Detector Table 5 OpenLAB CDS ChemStation Workstation VL compatibility with Agilent 1220 (II) Infinity LC Systems Product Number G4286B G4287B G4288B G4289B G4290B G4291B G4292B G4293B G4294B G4288C G4289C G4290C G4293C Module Name 1220 Infinity LC - Isocratic, Man. Inj., VWD, 600 bar 1220 Infinity LC - Isocratic, ALS, TCC, VWD, 600 bar 1220 Infinity LC - Gradient, Man. Inj., VWD, 600 bar 1220 Infinity LC - Gradient, ALS, TCC, VWD, 600 bar 1220 Infinity LC - Gradient, ALS, Man. Inj., TCC, VWD, 600 bar 1220 Infinity LC - Isocratic, Man. Inj., TCC, VWD, 600 bar 1220 Infinity LC - Isocratic, ALS, VWD, 600 bar 1220 Infinity LC - Gradient, ALS, VWD, 600 bar 1220 Infinity LC - Gradient, ALS, TCC, DAD, 600 bar 1220 Infinity LC - System VL, Gradient, Man. Inj. VWD, 400 bar 1220 Infinity LC - System VL, Gradient, Man. Inj. VWD, 400 bar 1220 Infinity LC - System VL, Gradient, ALS, TCC, VWD, 400 bar 1220 Infinity LC - System VL, Gradient, ALS, VWD, 400 bar With exception of modular pumps all Agilent LC modules may be connected as supplemental module to your 1220 LC system. CDS Supported Instruments and Firmware Guide 25

OpenLAB CDS ChemStation Edition: Classic Driver Support Information Classic Driver Support Information Classic GC, CE, 35900E, or LC drivers are no longer supported with ChemStation C.01.08. For information on reconfiguring instruments with classic drivers to use RC.net drivers please refer to Chapter 7, section Convert Classic Instrument Drivers to RC.NET of the OpenLAB CDS ChemStation Edition Workstation Installation and Configuration Guide (CDS_WS-InstallationGuide.pdf on disk2/docs). CDS Supported Instruments and Firmware Guide 26

www.agilent.com In This Book This guide summarizes the instruments and required Firmware supported for operation with the Agilent OpenLAB Chromatography Data System (CDS) ChemStation Edition C.01.08. P/N: M8301-90018 Rev B Agilent Technologies. 2010, 2011-2017 10/2017