FDMA MARINE SURGE PROTECTIVE DEVICE

Similar documents
Omni Marine Tel: +44(0) e:

C-POWER AC AUTOMATIC CONTROL

INSTALL INSTRUCTIONS RSXMR-9886-P-48

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations

MODEL 8000MP LEVEL SENSOR

Golight Radioray GL-2000-F Flood & Spot Light Combo - wireless remote control - permanent mount

B&W RearView Camera Installation & Operation

PanelView Plus/VersaView CE Terminals and Display Modules

poly-planar Marine Audio Systems

Surge Protection for Surveillance Systems

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

SURGE PROTECTION USER MANUAL. Surge Protection Device PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) B

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

SAVE THESE INSTRUCTIONS

RCL-50B PRODUCT SUPPORT MANUAL. Remote Control Searchlight Master Controller Point Pad. Y Rev. B

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

I-Line SPDs Square D TM Internally Mounted Surge Protective Devices

Chameleon Stand-alone

CLIPLINE complete. The modular terminal block system for all applications

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA

DC Outdoor Power Supply/Chargers

Always "On" UPS Systems Inc. USER MANUAL

SOUTH CAROLINA ELECTRIC COOPERATIVES SECONDARY TYPE 1 SURGE PROTECTIVE DEVICE SPECIFICATIONS Updated/Revised: October 6, 2014

Internal Modular SPDs

WLC60 Heavy Duty Stainless Steel LED Light

INSTALLATION INSTRUCTIONS

Adapter Kit - QSI Electronics to G-Series Meter Installation Instructions

ANSI C Dimming Receptacles

DirectCommand Installation DirectCommand Complete Wiring Harness

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

DBPApplication. PD Devices Ltd. Unit 1, Old Station Yard, South Brent, Devon. TQ10 9AL (0)

Note: Indented items indicate parts included in an assembly listed above

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

Surgelogic Surge Protective Devices LC, XR, and XW Series

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL. Total System Manager

PSBOC PSBOC 27,6V/5,5A/OC

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual

ASCO SERIES 300 Manual Transfer Switch Solutions

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual

DMK 11A & 11A GPS Owners Manual

16-Channel Digital Input Termination Card 24Vdc

Features: DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras

File E Project 08NK November 24,2009 REPORT TRANSIENT VOLTAGE SURGE SUPPRESSORS (VZCA/VZCA7)

The Art of LEDs TM. ULF24000 Series. ULF24000 Series Data Sheet Rev K (K)

WBS HARDWIRED SERIES 4-60KVA MAINTENANCE BYPASS SWITCH

Model HM-535 Power Supply Installation and Service Instructions

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras

User s Manual. Revision 1.0. Copyright 2016 Maretron, LLP All Rights Reserved

Surgelogic. Surge Protective Devices (SPDs) Residential. Catalog 6671CT9701R08/

Han PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

File E Project 08NK October 2, 2009 REPORT SURGE PROTECTIVE DEVICES (VZCA) GE Zenith Controls Bonham, TX

Integrated Battery Control System LBCS Step-by-Step Setup Guide

AIR COOLED MODULAR RECTIFIER

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

SSMx24 Series 240 ka Per Phase Peak Surge Current ANSI/UL1449 UL Fourth Edition

User Manual - Canada. TPS3 03 DC For DC Photovoltaic Applications. Surge Protective Device

JAN 16 Rev B

INTERCOM SYSTEM Model ICA900

( GRAY CONTROL BOX )

Ag Leader Technology. DirectCommand Installation RoGator Model Years

Compact plugs and receptacles standard or high temperature rated

November Amber fog light. Cool white CURVED LED LIGHT BARS CURVED LED LIGHT BARS - DUAL COLOUR

POE. The majority of PSE equipment requires a detection resistance of 24.9KΩ to establish a PoE link. Some models of PSE equipment require12.5kω.

Installation & Operation Instructions

Magnetically Actuated Safety Interlock Switches

IIM Warwick Court. Williamsburg VA REV 5

ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS

Kohler Generac (even new low voltage board).

PowerCore Model TEC-10 Installation Manual

BNC08128C. BNC 13,8V/8x1A/17Ah. Switch mode buffer power supply unit for CCTV. v.1.0 EN** Edition: 3 from

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

Part Name/Description Part Number Quantity

5 B&W Rear View System Camera

16-Channel Digital Input Termination Card 24Vdc

MC-1 OPERATION MANUAL MINI CAMERA JW FISHERS MFG INC 1953 COUNTY ST. E. TAUNTON, MA USA

Direct Injection Module

Redundancy unit CP-A RU

Quick Installation Guide

Features: SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

GE Digital Energy. Power Quality

2 in 1 LAN Tester and Multimeter Model:

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Connecting Power and Ground

Installation Instructions & User Manual POWERWARE TVSS ZONESENTINEL. AC Panel Transient Voltage Surge Suppressors

A Axis M-Functions Level 1 A Axis Standard A Axis SMT Level 2. Each console includes the following:

TM3DI16 module TM3-16 inputs

Installation and Operation Manual

Specifications, Installation, and Operating Instructions

Disconnect Switches. Safe Switching and Disconnecting

EN3 SERIES WEATHERTIGHT CONNECTORS NEW PRODUCT BULLETIN 602

Temperature Programming Quick Reference Guide

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

Wastewater Solutions. Featuring Meltric s DECONTACTOR TM Series Switch-Rated Plugs, Receptacles and Electrical Connectors. meltric.

xtablet T1600 Vehicle Holder Installation Guide

Hubbell Surge Protective DeviceS

Transcription:

FDMA MARINE SURGE PROTECTIVE DEVICE

FRY YOUR FISH NOT YOUR ELECTRONICS! Protect your costly GPS, Depth Finder and Fish Finder Introducing the FDMA-212HW and FDMA- 224HW, our new first line of defense for protecting sensitive on-board marine electronics. Protect your investment with the most advanced Surge Protective Device available on the market today. The hybrid design mitigates electrical surges and filters out ringing transients that can cause both immediate and long-term damage to your marine electronics. 1

Protect All Your On-Board Marine Electronics Available for both 12 volt (FDMA-212HW) and 24 volt (FDMA-224HW) electrical systems Parallel wired to protect your electrical panel, without draining your boat s batteries Robust 2 ka per mode Peak Surge Current Rating Voltage Responsive Circuitry TM protects your electrical system from impulse surges Frequency Responsive Circuitry TM filters out ringing transients, which disrupt and damage sensitive electronics All models are encapsulated for a superior watertight seal and vibration resistance Small, compact size can be installed virtually anywhere on your boat s electrical system 2

3 The FDMA Models of parallel wired marine SPDs provide superior transient voltage mitigation and protection for marine DC electrical systems.

Our SPDs are designed specifically to provide protection at locations feeding sensitive marine equipment and are designed to virtually eliminate ringing transients within the electrical system. These models are exceptionally effective in limiting transients generated within the vessel. All models have a robust 2 ka per mode peak surge current rating and component level thermal fusing. The Voltage Responsive Circuitry TM (VRC) mitigates the adverse effects of impulse surges due to external sources. Further, our Frequency Responsive Circuitry TM (FRC) mitigates and virtually eliminates ring wave, oscillating and switching transients. All FDMA models feature encapsulation of all electrical components to provide a watertight seal and superior vibration resistance. Providing effective and reliable surge suppression, these SPDs are compact in size which allows for versatile application and optimal installation, particularly in space constrained applications. 2-25/32" ø 0-3/16" 2-17/32" 2-17/32" 1" FDMA-212HW & FDMA-224HW MODELS 4

5

FDMA-HW Marine Surge Protective Device For use with 12 VDC Marine applications (Seachoice Part Number 19931) All wiring on the vessel shall be performed by a QUALIFIED MARINE ELECTRICIAN and in accordance with the Fire Protection Standard for Motor Craft, NFPA No. 302. The Standards of the American Boat and Yacht Council, Inc, and the USCG Safety Standards for Boat Electrical Systems (33 CFR 183). Installation Instructions* CAUTION! Always disconnect the battery from the electrical system before attempting to install the FDMA-HW. 1. Locate FDMA SPD close to the equipment to be protected Trim the leads as needed to keep them as short and straight as possible. 2. If the FDMA SPD is to be mounted in an area subject to corrosion, it is recommended that a liquid electrical coating or an environmentally sealed connector such as Cool Seal (P/N 50-63511) is applied to the lead connections. If using Cool Seal strip the leads to 1/4, insert the wire through the sealing gel and into the splice. Crimp the connection with a correct crimp tool such as Seachoice P/N 50-61221. 3. Connect the red wire to positive. 4. Connect the black wire to negative. 5. Mounting screw size is #10 pan head or flat head. Stainless steel hardware is recommended. Do not over-tighten screws to prevent deforming the enclosure mounting feet. 6. After installation, reconnect the battery terminals and depress the Push to Test switch located on the enclosure to verify the LED illuminates Green while the switch is depressed. The push to test switch + LED allow the status of the SPD to be verified without the LED constantly draining the battery. *See back cover for more installation options. 6

Full-size installation instructions can be downloaded at www.seachoice.com or an instruction video can be viewed at www.seachoice.com/videos.