USB Interface. Power Supply. Manual Raise/Lower Operators. Communications Port (Port 1) Communications Port (Port 2)

Similar documents
SEL-2414 Transformer Monitor

SEL-2411 Programmable Automation Controller

Power Quality and Recording Field Upgrade Available SEL-734, Standard Power Quality, 32 MB Memory SEL-734P, Advanced Power Quality, 128 MB Memory*

Firmware. Control Cable Interface

2 ms arc-flash protection and feeder relay in one platform

A low-cost, economical solution for distribution feeder protection

RTAC. SEL Real-Time Automation Controller. Integrate station control, a web-based HMI, and logging through one reliable system.

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

Lightweight and flexible recloser control for single-phase applications

SEL-710 Motor Protection Relay

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller

Advanced distribution feeder solution with integrated protection, monitoring, and control

SEL-2440 Discrete Programmable Automation Controller

SEL-700G Generator and Intertie Protection Relays

SEL-3332 Intelligent Server

Protection, Automation, and Control System. Combine subcycle line protection with complete substation bay control

Maximize process uptime with the SEL-patented motor thermal model.

SEL-2030 Communications Processor

Getting Started With SEL-3555 RTAC

Protect induction and synchronous motors with one relay.

High-speed transformer differential protection for up to five terminals

irbx6gf Features Intelligent 6 Port HSR/PRP Ethernet Switch IEC and IEEE 1613 Compliant

2 ms arc-flash protection and feeder relay in one platform

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

CL-7 microprocessor-based voltage regulator control and accessories

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Real-Time Automation Controllers (RTACs) Economical, multifunctional, compact real-time automation control

ipanel CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications ipanel Installation Guide

Powerful and flexible recloser control for many popular reclosers

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

CL-7 Microprocessor-Based Voltage Regulator Control and Accessories

SELect I/O Cards Part Numbers for the SEL 710 5

imc2f Features Industrial IEC Ethernet to Fiber Media Converter Tel: Fax:

Industrial IP67 Rated 8-Port 10/100Mbps M12 Fast Ethernet PoE Switch with Wide Operating Temperature

Modular Real-Time Automation Controller. Dependable control for harsh environments in a fully integrated, flexible platform

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

NTX Series Product Comparison

Installing the Cisco AS5400XM Universal Gateway

Designed, built, and tested for troublefree operation in extreme conditions

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists

imc2g Features Introduction Industrial Gigabit Ethernet to Fiber Media Converter Tel: Fax:

Major Features and Benefits

Major Features and Benefits

SEL-400 Series TiDL Quick-Start Guide

SEL-2730M. Reliably Control and Monitor Your Substation and Plant Networks. Managed 24-Port Ethernet Switch

imc2 Features Introduction Industrial 2 Port Ethernet to Fiber Converter Tel: Fax:

FSM-510G Series Ethernet Management Switch Quick Start Guide

Scout-S Station Controller

OmniConverterTM. OmniConverter GPoE+/Sx KEY FEATURES. Unmanaged 10/100/1000 Power Source Equipment (PSE) PoE/PoE+ Ethernet Fiber Switch

The SEL-700G Generator Protection Relay is the newest member of the SEL-700 series platform. It combines the protection features of the proven

Features and Benefits. Certifications

HDMI and Ethernet Extender via 2 Multimode Fibers LC Duplex Connector Extends HDMI+ 10/100M Ethernet Link Up To 800 Meters

SEL-3421 Motor Relay HMI (With LCD) Quick-Start Guide

SEL-2730M 24-Port Managed Ethernet Switch

PROFESSIONAL AUDIO AND MEDIA APPLICATIONS

Comprehensive protection for large, medium, and small generators

Dymec Serial Links. SubStation Hardened RS232 Serial Copper to Fiber Link/Repeaters. Features

Protect induction and synchronous motors with one relay

SEL-487B Bus Differential Relay

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

Our Most Important Connection is with You. OSIS SECTION 7. OSIS Series

LAUREL ELECTRONICS, INC.

RUGGEDCOM RMC8388. Rugged Media Converter. siemens.com/rmc8000. Edition 10/2015. Brochure

LightViper Components


Effective May 2018 Supersedes October 2017

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

MINER-S Station Controller

TCP. Control and Protection Terminal Data sheet

Serial Communication Card (SELECT EIA-232/485) Part Number Serial Communication 9787LA0_ (1) Note: Slot C option only.

CNSEISK 5, 8 & 16- Port Copper and Fibre Sub Miniature Ethernet 10/100 Switches

Protection, Automation, and Bay Control System. Advanced feeder protection and complete substation bay control in one economical system

Features and Benefits. Certifications

Bus Bar Protection Relay B-PRO 4000

SEL-2240 Axion. Rugged Digital I/O, Analog Inputs, Current and Voltage Measurements and Control for Your Toughest Applications

Black Box Tech Support: FREE! Live. 24/7.

HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual

Base Conn. G = ISM B = Bottom. * = Use part number D100E- -BY-000- if ordering ISM with bottom connector and PL17 wiring.

SEL-2411P Pump Automation Controller Data Sheet

PIX 535. PIX 535 Product Overview CHAPTER

Base Conn. S = Standard B = Bottom

Cabinet Interface Device

2 Channel POTS DIN Fiber Link System

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

High Voltage DC Meter

SEL-551/SEL-551C Overcurrent and Reclosing Relay

DVI Extender via 2 Multimode Fibers LC Duplex Connector Extends DVI + USB + Audio Link Up To 800 Meters

Multilink. Ethernet Communications for Industrial Automation, Power Utility, and Traffic Control markets. Multilin

Merging unit ENMU. Manual

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

IXIA NET TOOL OPTIMIZER 5204

HIGH-VOLTAGE DC METER

PACSystems RX7i IC698CMX016-ED

2 Channel POTS with I/O DIN Fiber Link System

Integrated Communications Optical Network. Guarantee fast and dependable operation for power protection and mission-critical

OmniConverterTM. OmniConverter GPoE/S, GPoE+/S and GHPoE/S 10/100/1000 Media Converter with Power over Ethernet (PoE, PoE+ or 60W PoE) KEY FEATURES

Transcription:

SEL-2431 Single-Phase Voltage Regulator Control, Two 120 Vac Voltage Inputs, Eight Contact Inputs (Two 120 Vac Programmable, Four 12 Vdc Self-Whetted Programmable, and Two Dedicated), Seven Contact Outputs (Four Programmable and Three Dedicated), Front Panel EIA-232 Port, Standard with ACSELERATOR QuickSet SEL-5030 Software (1) Part Number: 2 4 3 1 0 1 1 1 Firmware Standard - Voltage Regulator Control with Forward/Reverse Operating Modes, Line Drop Compensation, SELOGIC Programming, Metering, Event Reporting, SER, Load Profiling, Synchrophasors and Load Sense Technology 0 USB Interface 0 Type A USB Flash Drive Interface 1 Power Supply Standard - 120 Vac, 50/60 Hz 1 Manual Raise/Lower Operators Pushbutton Raise/Lower Operators (2) 1 Toggle Switch Raise/Lower Operators 2 Port (Port 1) EIA-232 (3) 1 EIA-485 (4-wire) (3) 2 Fiber Optic, 200µm, Multimode, VPIN Style Connector (3)(4) 3 Fiber Optic, 62.5µm, Multimode, ST Style Connector (3)(4) 4 EIA-485 (2-wire) (11) 5 Port (Port 2) EIA-232 (3) 1 EIA-485 (4-wire) (3) 2 Fiber Optic, 200µm, Multimode, VPIN Style Connector (3)(4) Fiber Optic, 62.5µm, Multimode, ST Style Connector (3)(4) EIA-485 (2-wire) (11) 5 Dual Fiber Ethernet 100BASE-F (Multimode) LC Connector (3) Dual Copper Ethernet (10/100BASE-T) RJ- 45 Connector (3) One Copper Ethernet (10/100BASE-T) RJ- 45 Connector and One Fiber Ethernet 100BASE-F (Multimode) LC Connector (3) Dual Fiber Ethernet 100BASE-L10 (Singlemode) LC Connector (3) 3 4 6 7 8 9 1 of 5 WI-10650

One Copper Ethernet (10/100BASE-T) RJ- 45 Connector, and One Fiber Ethernet 100BASE-L10 (Singlemode) LC Connector (3) A Conformal Coat Conformal Coated Circuit Boards 2 Retrofit Kits (Wiring Harness and Mounting Hardware) (8) Chalmers: 10-Position Polarized Disconnect Switch (PDS) Interface (5) Howard Industries: 10-Position Connector Terminal Strip (CTS) Interface (5) Edison: 18/10-Position Fanning Strip (Traditional) Interface (5) Cooper: 20-Position Connector (Dead- Front) Interface (5) GE: Fork-Terminal Connection (Traditional Interface to Cabinet NN Terminals) (5) GE: 24-Position Connector (Power Disconnect Interface) (5) Generic Fork Terminals for Chalmers/Howard/GE (Does not Include Mounting Hardware) (9) Generic Fork Terminals for Edison (Does not Include Mounting Hardware) (9) Packaged Accessories SEL-2401 Satellite-Synchronized Clock Accessory (7) SEL-2431 Surge-Suppression Accessory 1 2 Industrial Temperature-Rated USB Flash Drive, 1 GB Accessories Retrofit Kits (Wiring Harness and Mounting Hardware) Chalmers: 10- Position Polarized Disconnect Switch 9 2 5 3 0 0 2 (PDS) Interface Kit (5) Howard Industries: 10-Position Connector Terminal 9 2 5 3 0 0 3 Strip (CTS) Interface Kit (5) Edison; 18/10- Position Fanning 9 2 5 3 0 0 4 Strip (Traditional Interface Kit) (5) Cooper: 20-Position Connector (Dead- Front) Interface Kit (5) 9 2 5 3 0 0 5 1 0 2 0 3 0 3 1 4 0 4 1 0 1 0 2 1 1 3 0 2 of 5 WI-10650

GE: Fork-Terminal Connection (Traditional Interface 9 2 5 3 0 0 6 to Cabinet NN Terminals) Kit (5) GE: 24-Position Connector (Power Disconnect Interface) 9 2 5 3 0 0 7 Kit (5) Generic Fork Terminals for Chalmers/Howard/GE 9 2 5 3 0 0 1 (Does not Include Mounting Hardware) (9) Generic Fork Terminals for Edison (Does not 9 2 5 3 0 5 5 Include Mounting Hardware) (9) Mounting Hardware Kits Chalmers Mounting 9 2 5 3 0 5 9 Hardware Kit Howard Mounting 9 2 5 3 0 6 0 Hardware Kit Edison Mounting 9 2 5 3 0 5 8 Hardware Kit GE Mounting 9 2 5 3 0 5 7 Hardware Kit Other Accessories SEL-2401 Satellite- Synchronized Clock 9 2 5 3 0 5 1 Accessory Kit (7) Replacement Fuse 9 2 5 3 0 5 2 Kit SEL-2431 Configurable Labels 9 2 6 0 0 3 4 Kit Industrial Temperature-Rated 9 2 5 3 0 6 2 USB Flash Drive, 1 GB SEL-2431 Surge- Suppression 9 1 5 9 0 0 4 5 5 Accessory EIA-232 9 2 5 3 0 4 0 Card Kit (3) EIA-232 Card Kit with 9 2 5 3 0 4 0 C EIA-485 (4-wire) 9 2 5 3 0 4 1 Card Kit (3) EIA-485 (4-wire) Card Kit with 9 2 5 3 0 4 1 C 3 of 5 WI-10650

Literature Additional Cost Fiber-Optic, 200µm, Multimode, VPIN 9 2 5 3 0 4 2 Card Kit (3) Fiber-Optic, 200µm, Multimode, VPIN Card Kit with 9 2 5 3 0 4 2 C Fiber-Optic, 62.5µm, Multimode, ST 9 2 5 3 0 4 3 Card Kit (3) Fiber-Optic, 62.5µm, Multimode, ST Card Kit with 9 2 5 3 0 4 3 C EIA-485 (2-wire) 9 2 5 3 0 4 4 Card Kit (11) EIA-485 (2-wire) Card Kit with 9 2 5 3 0 4 4 C Conformal Coating (11) EIA-485 DB9 to 4-Position Compression C 6 7 7 Terminal Block Adapter (2-wire 485) EIA-485 DB9 to 8-Position Compression C 6 7 8 Terminal Block Adapter (4-wire 485) Printed Instruction Manual (10) P M 2 4 3 1-0 1 (1) Download ACSELERATOR QuickSet SEL-5030 software for free at https://www.selinc.com/softwaresolutions/. ACSELERATOR QuickSet on CD (503001W4) is available upon request. (2) Membrane Raise/Lower Pushbuttons do not provide manual operation when control power is lost. (3) Communication Port includes SEL-ASCII, SEL Compressed ASCII, Fast Meter, Fast Operate, PMU, and DNP3 Level 2 Slave protocols. (4) The optional VPIN style fiber-optic communication port is compatible with SEL-2800 and SEL-2810 Fiber-Optic Transceiver/Modems. The optional ST style fiber-optic communication port is compatible with the SEL-2812 Fiber-Optic Transceiver/Modem. (5) Includes mounting hardware (hinges and latch), and all necessary wiring harnesses (including PDS, CTS, Fanning Strip, or other applicable enclosure connector for mating with existing voltage regulator interfaces). (7) The SEL-2401 requires an EIA-232 or EIA-485 (4-wire) card in Port 1 for IRIG-B. (8) The SEL-2431 supports the following Single Phase Voltage Regulators: - Chalmers or Howard Type A with both a source and a load side PT. - Chalmers Type A Single Phase Voltage Regulator with only a source side PT. - General Electric or Cooper/McGraw Edison Type A. - Chalmers, General Electric, Howard, or Cooper/McGraw Edison Type B. (9) Does not include mounting hardware (hinges and latch). Includes wiring harness only. If mounting hardware is required, select appropriate kit from Accessories. (10) The SEL-2431 comes standard with a CD manual. One complimentary printed instruction manual is available upon request with each product purchased. (11) Communication Port includes: DNP3 Level 2 Slave protocol. 4 of 5 WI-10650

2350 NE Hopkins Court - Pullman, WA 99163 USA Phone: +1.509.332.1890 - Fax: +1.509.332.7990 5 of 5 WI-10650