Safety Standards. Model Number:

Similar documents
Safety Standards. Model Number:

Safety Standards. Model Number:

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

Safety Standards. Model Number:

Safety Standards. Model Number:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Safety Standards. Model Number:

Safety Standards. Model Number:

Safety Standards. Model Number:

Safety Standards. Model Number:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

Safety Standards. Model Number: Unit Weight:

030AAC Highlights & Features

350A Series MDS 350 A D 701 A A. Technical Datasheet Medical ATX Power Supply ATX 12V 1U Power Supply

Medical AC-DC Enclosed Power Supply 24V 200W 2 x4 High Density / MDS-200APB24 AA

Safety Standards. Model Number

MDS-300APB24 AA. Medical AC-DC Open Frame Power Supply 24V 300W with 5V/0.5A Standby / MDS-300APB24 AA MDS 300 A P B 24. Highlights & Features

Safety Standards. Model Number Input Voltage Output Voltage Convection Current Output Forced Air Current Output MDS 300 A D B 24

MDS-250A Series. Medical AC-DC Open Frame Power Supply 24V 250W with 5V/0.5A Standby / MDS-250A series MDS 250 A B 24. Highlights & Features

MDS-400ADB12 AA. Medical AC-DC Enclosed Power Supply 12V 400W 3.5 x5.5 High Density MDS-400ADB12 AA MDS 400 A D B 12 AA. Highlights & Features

Model Number: Unit Weight:

Safety Standards. Model Number:

Medical / Industrial AC-DC Power Supply 600W Convection Cooling / MEU-600C series

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ

Safety Standards. Model Number

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

MDS-400APB12. Medical AC-DC Open Frame Power Supply 12V/400W 3 x5 High Density MDS-400APB12 MDS 400 A P B 12. Highlights & Features.

TECHNICAL DATASHEET Medical AC-DC Enclosed Power Supply MDS-400ADB24 Highlights & Features Safety Standards Model Number: Unit Weight:

Safety Standards. Model Number:

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-24V100W1AX Vac ( Vdc) 24Vdc 4.17A

Safety Standards. Model Number:

PMT. Safety Standards. Model Number:

PJ Open Frame Power Supply 24V 50W 1 Phase / PJ-24V50W NA

PMC. PMC Panel Mount Power Supply 24V 50W 1 Phase / PMC-24V050W1A. Highlights & Features. Safety Standards. Model Number: General Description

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1A

CliQ DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1AZ

PMC. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-12V060W1NA Vac ( Vdc) 12Vdc 5.

Safety Standards. Model Number:

PMT. Model Number: CC Code PM 24V 200W 1 A Panel Mount Product Type T Enclosed L L Frame*

Chrome DIN Rail Power Supply 12V 25W 1 Phase (Class II & NEC Class 2) / DRC-12V30W1A

PMC. Safety Standards. Model Number:

PMC. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-24V600W1BA Vac ( Vdc) 24Vdc 25.

PMT. PMT Panel Mount Power Supply 5V 50W 1 Phase / PMT-5V50W1A. Highlights & Features. Safety Standards. Model Number: General Description

Model Number: Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMT-24V100W2AA Vac 24Vdc 4.50A

Safety Standards. Model Number:

PMC. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-48V150W1B Vac ( Vdc) 48Vdc 3.

PMT. Model Number: CC Code PM 24V 150W 1 A Panel Mount Product Type T Enclosed L L Frame*

Sync DIN Rail Power Supply 5V 15W 1 Phase (NEC Class 2) / DRS-5V30W1NZ

Chrome DIN Rail Power Supply 12V 72W 1 Phase (Class II) / DRC-12V100W1AZ

Model Number: Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMT-12V100W2B Vac 12Vdc 8.5A PMT-24V100W2B 24Vdc 4.

PMT. Safety Standards. Model Number:

Medical/Industrial AC-DC Configurable Power Supply Up to 2100 Watt / MEG-A Series

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-D2V100W1A. V1: 3.50A (Selectable by Switch) V2: 5Vdc

PJT Highlights & Features

LNE. LED Driver LNE-100W Series / LNE- V100W. Highlights & Features. Safety Standards. Model Number: General Description

PJ Open Frame Power Supply 12V 100W 1 Phase / PJ-12V100W A

Sync DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRS-24V30W1AZ

Sync DIN Rail Power Supply 24V 30W 1 Phase (NEC Class 2) / DRS-24V30W1AZ

PMT. Safety Standards. Model Number:

PMR. PMR Panel Mount Power Supply 4.2V 252W 1 Phase / PMR-4V320WC A. Highlights & Features. Safety Standards. Model Number: General Description

PJ Open Frame Power Supply 24V 100W 1 Phase / PJ-24V100W A

PMF. Safety Standards. Model Number:

CliQ DIN Rail Power Supply 24V 240W 1 Phase / DRP024V240W1AA

Safety Standards. Model Number:

LNE. LED Driver LNE-185W Series / LNE- V185W. Highlights & Features. Safety Standards. Model Number: General Description

PMT. Safety Standards. Model Number:

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-12V35W1A Vac 12Vdc 2.92A

Safety Standards. Model Number:

PMT. Safety Standards. Model Number:

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1A

PMC. Safety Standards. Model Number:

PMT. PMT Panel Mount Power Supply 12V 35W 1 Phase / PMT-12V35W1A. Highlights & Features. Safety Standards. Model Number: General Description

PMH. Safety Standards. Model Number:

CliQ DIN Rail Power Supply 12V 30W 1 Phase / DRP012V030W1A

PMR. PMR Panel Mount Power Supply 5V 300W 1 Phase / PMR-5V320WD A. Highlights & Features. Safety Standards. Model Number: General Description

Sync DIN Rail Power Supply 24V 50W 1 Phase (NEC Class 2) / DRS-24V50W1N

LNV. Safety Standards. Model Number:

CliQ DIN Rail Power Supply 24V 240W 3 Phase / DRP024V240W3AA

PMT. Safety Standards. Model Number:

Sync DIN Rail Power Supply 5V 50W Series / DRS-5V50W1A / DRS-5V50W1N

PMT. Model Number: Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMT-12V50W1A Vac 12Vdc 4.17A

Safety Standards. Model Number:

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

Output Voltage in Constant Voltage Mode. Model Number

CliQ DIN Rail Power Supply 12V 30W 1 Phase / DRP012V030W1A

LPS. ME20 20W Single Output External Power Medical Series. Features

PJ Open Frame Power Supply 12V 150W 1 Phase / PJ-12V150W

CliQ II DIN Rail Power Supply 24V 120W 3 Phase / DRP024V120W3B

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

Transcription:

065APS12 B Highlights & Features Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Low touch current (<0.1mA Normal &,0.3mA single fault) Over-Voltage/Load/Temperature & Short Circuit protections 2.5 Million Hours MTBF 2 x MOPP (means of patient protection) 3 years warranty Safety Standards General Description CB Certified for worldwide use Model Number: MDS-065APS12 B Unit Weight: 130 grams (4.6 Ounces) Dimensions (W x L x H): 50.8x101.6x30.0 mm 2.0x4.0x1.2 in The MDS series of embedded power supply come with universal AC input at 90Vac to 264Vac. Other features include low touch current, risk management report available and the electric shock protection comply with 2 x MOPP. The MDS series is certified for EMC standards according to EN 55011 for industrial, scientific and medical (ISM) radio-frequency equipment and EN 55022 for Information Technology Equipment (ITE) radio-frequency equipment. In addition, only recognized Japanese capacitors are used. The MDS series of embedded power supply come with both medical and ITE safety approvals including UL/cUL/CQC/CE and CB certification and are fully compliant with RoHS Directive 2011/65/EU for environmental protection. Model Information Medical AC-DC Open Frame Model Number Input Voltage Range Output Voltage Output Current MDS-065APS12 B 90-264Vac 12Vdc 5.42A Model Numbering MDS - 065 APS 12 B Delta Medical power Supply Max wattage in the product series. Maybe lower at some voltage. 065 65W Family Code Output Voltage Single Output: 12 for 12V 1

Specifications Input Ratings / Characteristics Nominal Input Voltage Input Voltage Range Nominal Input Frequency Input Frequency Range Input Current (max) Efficiency (typ.) 100-240Vac 90-264Vac 50-60Hz 47-63Hz Standby Power (max) 0.3W Inrush Current (typ.) 1.5A @ 100Vac, 0.75A @ 240Vac 87.5%, Reference Fig.1 40A @ 115Vac, 80A @ 230Vac Touch Current (max) 0.1mA @ 264Vac NC 1), 0.3mA @ 264Vac SFC 2) 1) NC: normal condition 2) SFC: single fault condition Fig.1 Efficiency versus output load Output Ratings / Characteristics Nominal Output Voltage 12Vdc Total regulation ± 1.5% Output Current 5.42A Output Power 65W Output Peak Load 6.92A* Line Regulation (max) ±0.5% Load Regulation (max) ±1% Ripple & Noise (typ.) 21.6mV pk-pk @ Full load, Reference Fig. 2, Start-up Time(max) 3000ms @ 115Vac Hold-up Time(min) 15ms @ 115Vac Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 5% @ 50-100% load *Output peak can last 8 sec with 10% duty cycle, and the output voltage should meet ±5% voltage regulation at normal input voltage 2

(a) 115V Fig. 2 Ripple & Noise example, 20MHz BW (b) 230V PSU 5cm 0.47uF Ceramic 10uF Electrolytic Load Scope Test Fixture Fig. 3 Ripple & Noise measurement circuit Mechanical Dimensions(W x L x H) Weight (typ.) Terminal Environment Surrounding Air Temperature Power De-rating Operating Humidity Operating Altitude Shock Test (Non-Operating) Vibration (Operating) Input Output Operating Storage 50.8 x 101.6 x 30.0 mm(2 x 4 x 1.2 in) 130 grams (4.6 Ounces) JST 2P JST 4P -10 C to +70 C -40 C to +85 C -10 C to +50 C 100% load 50 C to 70 C de-rate power by 2.5% / C, See Fig. 3 10-95% RH (Non-Condensing) 3,000 meters (9842.52 feet) 50G, 11ms, 3 shocks for each direction 5-500Hz, 2.09Grms, 20 minute for each three axis 3

Protections Over Voltage (max) Over Load / Over Current Over Temperature Short Circuit Protection Against Shock 150%, Latch Mode 150%~210% of rated load current, Hiccup Mode, (Non-Latching, Auto-Recovery) Hiccup Mode, (Non-Latching, Auto-Recovery) Hiccup Mode, (Non-Latching, Auto-Recovery) Class I with PE* connection *PE: Protective Earth Reliability Data MTBF (typ.) 2.5 Million Hours based on Telecordia SR-332 Safety Standards / Directives Medical Safety ITE Safety IEC60601-1: (Ed.3,2005), EN60601-1:2006, CAN/CSA- C22.2 No. 60601-1:08, ANSI/AAMI ES60601-1: (Ed.3,2005) IEC 60601-1 Edition 3.1 (2012), EN60601-1 (2006) + A11 + A1 + A12, CAN/CSA-C22.2 NO. 60601-1:14, ANSI/AAMI ES60601-1:2005/(R)2012 IEC60950-1 (Ed.2,2005), GB4943.1-2011, GB9254-2008, GB17625.1-2003 CE MDD Directive 93/42/EEC Material and Parts RoHS Directive 2011/65/EU Compliant Galvanic Isolation Input to Output 4000 Vac Input to Ground 1500 Vac Output to Ground 500 Vac 4

EMC (Compliant with IEC 60601-1-2 4th Ed. Requirements) EMC / Emissions EN55011/EN55022,FCC Title 47:Class B Harmonic Current Emissions IEC61000-3-2 Meet Class A limit Voltage Flicker Immunity to IEC61000-3-3 Electrostatic Discharge IEC61000-4-2 Level 4 Criteria A 1) Radiated Field IEC61000-4-3 Criteria A 1) Air Discharge: 15kV Contact Discharge: 8kV Electrical Fast Transient / Burst IEC61000-4-4 Level 3 Criteria A 1) :2kV Surge IEC61000-4-5 Level 3 Criteria A 1) 80MHz-2700MHz, 10V/m AM modulation 385MHz-5785MHz, 28V/m Pulse mode and other modulation Common Mode 3) : 2kV Differential Mode 4) : 1kV Conducted IEC61000-4-6 Level 2 Criteria A 1) 150kHz-80MHz, 3Vrms, 6Vrms at ISM bands and Amateur radio bands Power Frequency Magnetic Fields IEC61000-4-8 Criteria A 1) Magnetic field strength 30A/m Voltage Dips IEC61000-4-11 Criteria A 1) 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restore to normal operation after test. 3) Asymmetrical: Common mode (Line to earth) 4) Symmetrical: Differential mode (Line to line) 0% UT, 0.5 cycle (10ms), 0 o /45 o /90 o /135 o /180 o /225 o /270 o /315 o /360 o Criteria B 2) 0% UT, 1 cycle (20ms), 0 o Criteria A 1) 70% UT, 25 cycle (500ms), 0 o Criteria B 2) 0% UT, 250 cycle (5000ms), 0 o 5

Block Diagram 6

Dimensions W x L x H: 50.8x101.6x30 mm Notes Dimensions are in mm For optimum EMC performance, the two mounting points with ground symbol shown in mechanical drawing need to be connected together to system earth case. Method of protective earth connection: When system (End products ) protective earth connection is connected to system s (or end products) enclosure/cover (afterward named system for short). Two mounting holes which are marked ground symbols in mechanical drawing are needed to link system together by conductive screw 7

Power De-rating Output Power 100% 50% 0% -10 C 50 C 70 C Ambient Temperature Fig. 3 Functions Start-up Time The time required for the output voltage (Vo) to reach 90% of its set value, after the input AC voltage is applied. Rise Time The time required for the output voltage (Vo) to change from 10% to 90% of its steady state value. Hold-up Time Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time required for the output to reach 95% of its set value, after the input voltage is removed. Graph illustrating the Start-up Time, Rise Time, and Hold-up Time 8

Dynamic Response The power supply output voltage will remain within ±5% of its steady state value, when subjected to a dynamic load change from 50 to 100% of its rated current. 100% Load Overload & Over current Protections The power supply s Overload (OLP) and Over current (OCP) Protections will be activated when output current is between 150% and 210% of I O (Max load). Upon such an occurrence, V O will start to drop. Once the power supply has reached its maximum power limit, the protection will be activated. and the power supply will go into Hiccup mode (Auto-Recovery). The power supply will recover once the fault condition causing the OLP and OCP is removed and I O is back within the specified limit. 50% Load 50ms 50ms 50ms 50ms T (sec) Inrush Current Inrush current is the input current that occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. Additionally, if the I O is <115% but >100% for a prolong period of time (depending on the load), the Over Temperature Protection (OTP) will be activated due to high temperature on critical components. The power supply will then go into hiccup mode until the fault is removed; and, the input voltage is removed, then reapplied. Over Temperature Protection As mentioned above, the power supply also has Over Temperature Protection (OTP). This is activated when the overload condition persists for an extended duration and the output current is below the overload trigger point but >100% load. In the event of a higher operating condition at 100% load, the power supply will run into OTP when the surrounding air temperature is higher than the operating temperature. When activated, the output voltage will go into hiccup mode until the input voltage is removed; then, reapplied, and the surrounding air temperature drops to its normal operating temperature. Overvoltage Protection The power supply s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under Protections. Power supply will latch off, and require removal/re-application of input AC voltage in order to restart. Short Circuit Protection The power supply s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in Hiccup mode, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. 9

Certificate. All Delta Medical Power products conform to the European directive 2011/65/EU. RoHS is the abbreviation for Restriction of the use of certain hazardous substances. Delta has been certified as meeting the requirement of ISO 13485: 2003 and EN ISO 13485:2012 for the design and manufacture of switching power supply and adaptor for medical device. In addition to a UL Total Certification Program (TCP) approved client laboratory for IEC60950 and IEC60065. Delta also has participated UL Client Test Data Program (CDTP) for IEC 60601 10