Dell PowerEdge R720 and R720xd Getting Started Guide

Similar documents
Dell PowerEdge T620 Getting Started Guide

Dell PowerEdge T420 Getting Started Guide

Dell PowerEdge T620 Getting Started Guide

Dell PowerVault MD3400/3420/3800i/3820i/ 3800f/3820f Storage Arrays Getting Started Guide

Dell PowerVault MD3460/3860i/3860f Storage Arrays Getting Started Guide

Dell Storage MD1400 and MD1420 Enclosures Getting Started Guide

Dell PowerVault MD3400/3420/3800i/3820i/3800f/ 3820f Storage Arrays Getting Started Guide

IndigoVision Enterprise NVR-AS 4000 Linux Appliance. Quick Start Guide

Dell OptiPlex SFF AIO Stand. User s Guide. Model: IKAIO-01 1 /13

Dell PowerVault Network Attached Storage (NAS) Systems Running Windows Storage Server 2012 Troubleshooting Guide

Dell SC7020 Storage Controller Getting Started Guide

IndigoVision Enterprise NVR-AS 4000 G3 Windows Appliance. Quick Start Guide

LSI SAS i PCIe to 6Gb/s SAS HBA Running On Dell Systems Important Information

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Dell SC460 Expansion Enclosure Getting Started Guide

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

Dell Optiplex 390. Setup And Features Information. About Warnings. Mini-Tower Front And Back View

Dell Reseller Option Kit Important Information

Dell OptiPlex XE2. Setup And Features Information. Mini-Tower Front and Back View. About Warnings

Dell Precision T1700. Setup And Features Information. Mini-Tower Front and Back View. About Warnings

Dell Server PRO Management Pack 3.0 for Microsoft System Center Virtual Machine Manager Installation Guide

Dell PowerEdge M905, M805, M605, and M600. Getting Started With Your System

Dell Server PRO Management Pack for Microsoft System Center Virtual Machine Manager Installation Guide

Dell Latitude Setup And Features Information. Front View. About Warnings

Release Notes. Dell Server Management Pack Suite For CPS. Version 5.1.1

Dell SupportAssist Version For Dell OpenManage Essentials Quick Start Guide

Dell MD1280 Storage Enclosure Getting Started Guide

Dell Vostro 460. About Warnings. Setup and Features Information

Dell Precision Mobile Workstation M4700/M6700

Dell SupportAssist Version 1.2 For Dell OpenManage Essentials Quick Start Guide

Dell Latitude E6220. Setup And Features Information. About Warnings. Front And Back View

Dell EqualLogic Storage Management Pack Suite Version 5.0 For Microsoft System Center Operations Manager And Microsoft System Center Essentials

NOTE: Use the System Setup program to view microprocessor information. For more information, see "Using the System Setup Program."

Shared LOM support on Modular

Management Station Software Version 7.3 Installation Guide

Dell PowerVault MD3060e Storage Enclosure Owner's Manual

SCv360 Expansion Enclosure

Dell Appliance for Wyse

Dell Vostro 3350/3450/3550/3555/3750

Dell SupportAssist Version 1.2 For Dell OpenManage Essentials Support Matrix

Configuring Direct-Connect between a DR Series System and Backup Media Server

Dell Precision M4600/M6600 Mobile Workstation

Dell Server Management Pack Suite Version For Microsoft System Center Operations Manager And System Center Essentials User s Guide

Dell PowerVault MD Storage Array Management Pack Suite Version 5.0 For Microsoft System Center Operations Manager And Microsoft System Center

Dell Server Management Pack Suite Version For Microsoft System Center Operations Manager And System Center Essentials Installation Guide

Lifecycle Controller with Dell Repository Manager

Dell EqualLogic Storage Management Pack Suite Version 5.0 For Microsoft System Center Operations Manager And System Center Essentials User s Guide

Dell 1741M Converged Network Adapter FCoE Boot from SAN Guide

Using Dell Repository Manager with Dell OpenManage Essentials

OpenManage Integration for VMware vcenter Using the vsphere Client Quick Install Guide Version 2.0

Dell Server Deployment Pack Version 2.0 for Microsoft System Center Configuration Manager User's Guide

Deploying Solaris 11 with EqualLogic Arrays

Dell Vostro 320 Setup and Features Information Tech Sheet

Teradici APEX 2800 for VMware Horizon View

Dell EMC PowerEdge R540

Active Fabric Manager Installation Guide 1.5

Dell EMC PowerEdge R7415

Dell EMC PowerEdge R6415

Setting Up Replication between Dell DR Series Deduplication Appliances with NetVault 9.2 as Backup Software

Using Lifecycle Controller to Configure UEFI Secure Boot and OS Deployment

Dell Force10 Z9000 System. Quick Start Guide. Regulatory Model: Z9000

Dell Wyse Datacenter for VMware Horizon View Cloud Pod Architecture

Dell Repository Manager Version 1.8 Troubleshooting Guide

Dell Vostro 1014 and 1015 Setup and Features Information Tech Sheet

Dell Latitude E5410/E5510

Dell EMC PowerEdge R440

Dell Precision Workstation T7500/T7500n Setup and Features Information

SUU Supporting the DUP Dependency

Access Control Policies

Dell EMC PowerEdge XR2

Dell Vostro 1310/1510/1710/2510 Setup and Features Information

Dell Inspiron 580: Comprehensive Specifications

Dell PowerEdge FC640. Technical Specifications. Regulatory Model: E02B Series Regulatory Type: E02B005

Dell Force10 S55 and S60 Systems. Quick Start Guide. Regulatory Model: S55/S60

Dell Latitude E5400 and E5500 Setup and Features Information

Dell Latitude in-1

Dell EMC PowerEdge T440

Dell EMC PowerEdge FC640

Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode)

Inspiron Setup and Specifications

Dell EMC PowerEdge R540

Dell EMC PowerEdge R740xd

Dell EMC PowerEdge R740

Dell EMC PowerEdge R740xd

Dell Networking MXL / PowerEdge I/O Aggregator with Cisco Nexus 5000 series NPV mode and Cisco MDS 9100 fabric switch Config Sheets

Dell Lifecycle Controller Integration For Microsoft System Center Configuration Manager Version Installation Guide

Wired + Wireless Cloud-managed Campus Reference Architecture

RazorSafe 7-Series Hardware Getting Started Guide

Active Fabric Manager. Release Notes 1.5. June 2013

Inspiron 15. Setup and Specifications Series 2-in-1. Computer Model: Inspiron Regulatory Model: P58F Regulatory Type: P58F001

Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config Sheets

Inspiron in-1 Setup and Specifications

Inspiron Setup and Specifications

Web Service Eventing Support for Hardware Inventory and Monitoring

Dell Fabric Manager Deployment Guide 1.0.0

Dell XC430 Web-Scale Hyperconverged Appliance Support Matrix

Inspiron Setup and Specifications

Inspiron 13. Setup and Specifications Series 2-in-1. Computer Model: Inspiron Regulatory Model: P69G Regulatory Type: P69G001

Inspiron Setup and Specifications. 2-in-1. Computer Model: Inspiron Regulatory Model: P58F Regulatory Type: P58F001

Transcription:

Dell PowerEdge R720 and R720xd Getting Started Guide Regulatory Model: E14S Series Regulatory Type: E14S001

Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. 2012 Dell Inc. Trademarks used in this text: Dell, the Dell logo, Dell Boomi, Dell Precision, OptiPlex, Latitude, PowerEdge, PowerVault, PowerConnect, OpenManage, EqualLogic, Compellent, KACE, FlexAddress, Force10 and Vostro are trademarks of Dell Inc. Intel, Pentium, Xeon, Core and Celeron are registered trademarks of Intel Corporation in the U.S. and other countries. AMD is a registered trademark and AMD Opteron, AMD Phenom and AMD Sempron are trademarks of Advanced Micro Devices, Inc. Microsoft, Windows, Windows Server, Internet Explorer, MS-DOS, Windows Vista and Active Directory are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Red Hat and Red Hat Enterprise Linux are registered trademarks of Red Hat, Inc. in the United States and/or other countries. Novell and SUSE are registered trademarks of Novell Inc. in the United States and other countries. Oracle is a registered trademark of Oracle Corporation and/or its affiliates. Citrix, Xen, XenServer and XenMotion are either registered trademarks or trademarks of Citrix Systems, Inc. in the United States and/or other countries. VMware, Virtual SMP, vmotion, vcenter and vsphere are registered trademarks or trademarks of VMware, Inc. in the United States or other countries. IBM is a registered trademark of International Business Machines Corporation. 2012 09 Rev. A01

Installation And Configuration WARNING: Before performing the following procedure, review the safety instructions that came with the system. Unpacking a Rack System Unpack your system and identify each item. Assemble the rails and install the system in the rack following the safety instructions and the rack installation instructions provided with your system. Figure 1. Installing the Rails and System in a Rack Connecting The Optional Keyboard, Mouse, And Monitor Figure 2. Connecting Keyboard, Mouse, and Monitor Connect the keyboard, mouse, and monitor (optional). The connectors on the back of your system have icons indicating which cable to plug into each connector. Be sure to tighten the screws (if any) on the monitor's cable connector. 3

Connecting The Power Cable(s) Figure 3. Connecting the Power Cable(s) Connect the system s power cable(s) to the system and, if a monitor is used, connect the monitor s power cable to the monitor. Securing The Power Cable(s) Figure 4. Securing the Power Cable(s) Bend the system power cable(s), as shown in the illustration, and attach to the cable strap. Plug the other end of the power cable(s) into a grounded electrical outlet or a separate power source such as an uninterruptible power supply (UPS) or a power distribution unit (PDU). 4

Turning On The System Figure 5. Turning on the System Press the power button on the system. The power indicator should light. Installing The Optional Bezel Figure 6. Installing the Bezel Install the bezel (optional). Complete The System Setup If you purchased a preinstalled operating system, see the documentation associated with the operating system. To install an operating system for the first time, see the installation and configuration documentation for your operating system. Be sure the operating system is installed before installing hardware or software not purchased with the system. NOTE: For the latest information on supported operating systems, see dell.com/ossupport. Dell Software License Agreement Before using your system, read the Dell Software License Agreement that came with your system. You must consider any media of Dell-installed software as BACKUP copies of the software installed on your system s hard drive. If you do 5

not accept the terms of the agreement, call the customer assistance telephone number. For customers in the United States, call 800-WWW-DELL (800-999-3355). For customers outside the United States, visit support.dell.com and select your country or region from the bottom of the page. Other Information You May Need WARNING: See the safety and regulatory information that shipped with your system. Warranty information may be included within this document or as a separate document. The Owner s Manual provides information about system features and describes how to troubleshoot the system and install or replace system components. This document is available online at support.dell.com/manuals. The rack documentation included with your rack solution describes how to install your system into a rack, if required. Any media that ships with your system that provides documentation and tools for configuring and managing your system, including those pertaining to the operating system, system management software, system updates, and system components that you purchased with your system. NOTE: Always check for updates on support.dell.com/manuals and read the updates first because they often supersede information in other documents. NOTE: When upgrading your system, it is recommended that you download and install the latest BIOS, driver, and systems management firmware on your system from support.dell.com. Obtaining Technical Assistance If you do not understand a procedure in this guide or if the system does not perform as expected, see your Owner s Manual. Dell offers comprehensive hardware training and certification. See dell.com/training for more information. This service may not be offered in all locations. NOM Information The following information is provided on the device described in this document in compliance with the requirements of the official Mexican standards (NOM): Importer: Model number: Supply voltage: Frequency: Current consumption: Dell Inc. de México, S.A. de C.V. Paseo de la Reforma 2620-11º Piso Col. Lomas Altas 11950 México, D.F. E14S 100 240 V CA (with 495 W, 750 W, and 1100 W AC power supply unit) or 200 240 V CA (with 750 W Titanium power supply unit) or (48 60) V de CC (with 1100 W DC power supply unit) 50 Hz/60 Hz (AC power supply unit) 12 A 6.5 A (X 2) (with 1100 W AC power supply unit) 10 A 5 A (X 2) (with 750 W AC power supply unit) 5 A (X 2) (with 750 W Titanium redundant AC power supply unit) 6.5 A 3 A (X 2) (with 495 W AC power supply unit) 32 A (X 2) (with 1100 W DC power supply unit) 6

Technical Specifications Power NOTE: The following specifications are only those required by law to ship with your system. For a complete and current listing of the specifications for your system, go to support.dell.com. NOTE: The following specifications apply to both PowerEdge R720 and PowerEdge R720xd unless specified. AC Power Supply (per power supply) Wattage Heat dissipation Voltage NOTE: Heat dissipation is calculated using the power supply wattage rating. NOTE: This system is also designed to be connected to IT power systems with a phase to phase voltage not exceeding 230 V. 495 W, 750 W, or 1100 W 1908 BTU/hr maximum (495 W power supply) 2891 BTU/hr maximum (750 W power supply) 2843 BTU/hr maximum (750 W Titanium power supply) 4100 BTU/hr maximum (1100 W power supply) 100 240 V AC, autoranging, 50/60 Hz or 200 240 V AC, autoranging, 50/60 Hz, for 750 W Titanium power supply DC Power Supply (per power supply) Wattage Heat dissipation 1100 W 4416 BTU/hour maximum NOTE: Heat dissipation is calculated using the power supply wattage rating. Voltage (48 60) V DC Battery Coin-cell battery 3 V CR2032 Lithium coin cell Physical Height 87.3 mm (3.44 inch) Width With rack latches Without rack latches Depth (includes bezel) 482.4 mm (18.98 inch) 444 mm (17.48 inch) 755.8 mm (29.75 inch) Weight (maximum) 2.5-inch hard-drive systems (PowerEdge R720) 2.5-inch hard-drive systems (PowerEdge R720xd) 3.5-inch hard-drive systems (PowerEdge R720) 3.5-inch hard-drive systems (PowerEdge R720xd) 29.5 kg (65.03 lbs) 28.1 kg (61.94 lbs) 29.2 kg (64.37 lbs) 30.9 kg (68.12 lbs) 7

Physical Weight (empty) 2.5-inch hard-drive systems (PowerEdge R720) 2.5-inch hard-drive systems (PowerEdge R720xd) 3.5-inch hard-drive systems (PowerEdge R720) 3.5-inch hard-drive systems (PowerEdge R720xd) 11.7 kg (25.7 lbs) 17.7 kg (39.02 lbs) 10.3 kg (22.7 lbs) 17.2 kg (37.91 lbs) Environmental NOTE: Your system is capable of 40 C and 45 C excursion operation for fresh air cooled data centers. For more information, see the Owner's Manual. NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets. Temperature Continuous operation: 10 C to 35 C. De-rate maximum allowable dry bulb temperature at 1 C/300 m above 900 m (1 F /550 ft). NOTE: For information on supported expanded operating temperature range and configurations, see support.dell.com/manuals. 40 C to 65 C ( 40 F to 149 F) with a maximum temperature gradation of 20 C per hour. Relative humidity 10% to 80% relative humidity (RH), with 26 C maximum dew point. 5% to 95% relative humidity ambient with 33 C (91 F) maximum dew point. Maximum vibration 0.26 Grms at 5 Hz to 350 Hz (all operation orientations). 1.87 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested). Maximum shock One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.6 ms in the operational orientation. Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms. Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of 8

Environmental Altitude the system) of 22 G faired square wave pulse with velocity change at 200 inches/second (508 centimeters/ second). 15.2 m to 3048 m ( 50 to 10,000 ft). NOTE: For altitudes above 2950 ft, the maximum operating temperature is derated 1 ºF/550 ft. 15.2 m to 10,668 m ( 50 ft to 35,000 ft). Airborne contaminant level Class G1 as defined by ISA-S71.04-1985. 9