Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

Similar documents
Artistic Licence. Rail-Demux. User Guide. Rail-Demux User Guide. Version 2-7

Artistic Licence. Rail-Split RDM. User Guide. Serial nos and upwards. Rail-Split RDM User Guide. Version 5-0

Artistic Licence. Rail-Split extreme. User Guide. Serial numbers 151 upwards. Rail-Split extreme User Guide. Version 5-0

Artistic Licence. artlynx duo. User Guide. artlynx duo User Guide. Version 1-0

Artistic Licence. Rail-DALI-DMX. User Guide. Rail-DALI-DMX User Guide. Version 1-5

Artistic Licence. Mica. User Guide. Mica User Guide. Version 1-1

Artistic Licence. matisse d4 dmx. User Guide. matisse d4 dmx User Guide. Version 1-1

Artistic Licence. Net-Lynx O/P. User Guide. Net-Lynx O/P User Guide. Version 1-5

Artistic Licence. daligate quad. User Guide. daligate quad User Guide. Version 1-0

Artistic Licence. Net-Lynx I/P. User Guide. Net-Lynx I/P User Guide. Version 1-5

Artistic Licence. Cata-Lynx I/P. User Guide. Cata-Lynx I/P User Guide. Version 1-4

Artistic Licence. Dali-Scope. User Guide. Dali-Scope User Guide. Version 1-8

Artistic Licence. versasplit. User Guide. versasplit User Guide. Version 1-5

Split2.8 RDM. 2 input DMX/RDM Splitter. User guide

Artistic Licence. Ether-Lynx II. User Guide. Ether-Lynx II User Guide. Version 1-5

Artistic Licence. nanoscope. User Guide. nanoscope User Guide. Version 1-0

EtherN.8 RDM & EtherN.2 RDM

Flexoled FTP3HP RGB LED DMX Driver

FTP1 Single Channel LED DMX Driver

CS2 DMX Distribution Splitter

ISP Installation Splitter User Manual

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

RТTH DUAL ROOM SWITCH

Operating instructions Evaluation system for flow sensors VS / / 2013

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Version 5 Controls for natural ventilation. WUF 110 / 121 / 150 Actuator interfaces

DOR6. Components All functions and indications are on the front of the module. Characteristics

Installation Manual for D244X Series 24-volt Power Supplies

INSTALLATION MANUAL. HDMI 1x8 Splitter B-230-HDSPLTR-1x8 B-230-HDSPLTR-1X8

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

APT20. User Manual.

Operating instructions. Standstill monitor A / / 2011

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

INSTALLATION MANUAL. HDMI 1x4 Splitter B-230-HDSPLTR-1x4. B-230-HDSPLTR-1x4 HDMI OUT 4 HDMI OUT 3 HDMI OUT 2 HDMI OUT 1 HDMI OUT 4 HDMI IN

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

RGB Power Batten. User Manual. Order code: EQLED032

Artistic Licence Price List


SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

HDMI 1x2 Splitter B-230-HDSPLTR-1x2 INSTALLATION MANUAL HDMI OUT 2 HDMI OUT 1 B-230-HDSPLTR-1X2 POWER HDMI IN

RXTH DUAL ROOM SENSOR / SWITCH

MC 11 EB-2 Power supply cabinet with external bus, AC version

CDP 405 Digital Dimmer Pack

Blitzer Strobe. User Manual. Order code: EQLED366

Crossfire. User Manual. Order code: EQLED061

DMX LED Starcloth Systems

IIM Warwick Court. Williamsburg VA REV 5

UV Power Flood. User Manual. Order code: EQLED029

Product Manual. USB Charging Hub 10 Port Hi-Power 2.4A USB Charger Hub. Coolgear, Inc. Version 1.1 September 2017 Model Number: U2CHGRHUB10

Blitzer RGB Strobe. User Manual. Order code: EQLED365

Control different load types with one device

Operating instructions. Switching amplifier DN0210 DN / / 2015

PC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

SP SP-T-9

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

Sollatek SVS Range Voltage Stabilisers User Manual

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Installation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control

RXTP ROOM TEMPERATURE

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

Ether-Lynx User s Guide

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

One Channel and Two Channel DALI Relay Device

Room Temperature Controller

Microbar COB System. User Manual. Order code: EQLED137

SX2200 Series INSTALLATION INSTRUCTIONS. Electronic Systems Protection, Inc 8001 Knightdale Blvd. Suite 121 Knightdale NC 27545

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Switched Mode Power Supply Operating manual PAP800

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

Buffered Power Supply PS-30DR v1.0

Vector Beam White. User Manual. Order code: LEDJ265

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Chassis Power Supplies

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

XTM1250SA DIN rail three phase four wire LCD display energy meter

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Priva Blue ID Relay output module DOR4/DOR8

PRO-1250D CT MID DIN rail three phase four wire energy meter.

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

TRC-190 User s Manual

Gobo Projector XP 80W

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

w w w. p r o l i g h t. c o. u k STAGE PAR 64

Control different load types with one device

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Transcription:

Artistic Licence Rail-Switch II User Guide Version 5-5

Please read these instructions before using the product. This product has been designed & manufactured for professional use only. It should only be installed by a suitably qualified technician and in accordance with electrical regulations in the country of use. Unless directed in the instructions there are no user serviceable parts inside the outer case of this product. Always disconnect from the power supply when not in use. Any specific IP rating, where appropriate, is given in the instructions. Unless otherwise stated this product is designed for indoor use only. If used outdoors it MUST be installed in an appropriate IP rated cabinet. Do not allow this product to be exposed to rain or moisture. Do not allow liquid to penetrate the product. Please recycle all packaging. Copyright Artistic Licence Engineering Ltd. All rights reserved. Download the user guide by scanning the following QR code: Page 2

Connections Reference Type Description 1 LED Data type 2 LED Power/ RDM locate 3 Connection Power Input 4 Connection DMX512 Input 5 Connection DMX512 Loop & Term 6 Connection Relay Outputs 7 LED Relay energised ** A passive loop-through connection allows onward connection to other DMX512 devices. If this feature is not required then the signal must be terminated. The product contains an internal termination resistor. This is enabled by fitting a wire link between Term and DAT+. DMX512 Wiring XLR Pin Function Colour (Convention) 1 Ground Black 2 Data - Blue 3 Data + Red Internal Earth and Isolation Circuit DMX512 Input (including Loop Through) Relay Outputs Internal Logic Ground Type: Pin 1: Description Isolated, volt-free Connects to Ground Power Input Non-isolated Connects to Internal Logic Ground Mounting Diagram Page 3

Overview In theatre, touring and architectural applications there are invariably some devices that do not provide a useful form of remote control. Rail-Switch II is an elegant solution to the automation of these devices. Rail-Switch II is a DIN Rail mounted device that provides 6 mains voltage relays and is controlled via DMX512 & RDM. Each relay can be switched independently. The product is powered via an external DC power supply unit. The product is configurable using RDM. This is particularly useful in enabling the start address of each relay to be set individually. Summary of Key Features y 6 mains relays y Relays rated at 250V AC, 8A noninductive y DMX/RDM controlled y LED indication for data, power and each relay output y Simulated RDM sub-devices for start address programming y Preset mode eliminates need for DMX controller y Data loss and test modes y DIN Rail or surface mount Connections Input The DMX512 input is attached via a 3-pin screw terminal. Please refer to the connections diagram. Loop Through A passive loop-through connection allows onward connection to other DMX512 devices. If this feature is not required then the signal must be terminated. The product contains an internal termination resistor. This is enabled by fitting a wire link between the screw terminals that will terminate the DMX line (Term and DAT+). Output Six relay outputs are provided. It is recommended that the output wires are fitted with separate ferrite cores when driving a high current load. Power Rail-Switch II is be powered from an external DC power supply (9-24 VDC). It is recommended that a ferrite core be fitted onto the DC power lines as close as possible to the Rail-Switch II. This protects the unit from any electrical spikes that appear on the DC line. Relays The relays energise at a DMX value of 128. Each relay has three connections; Common, Normally Open and Normally Closed. Common (C) This connection is always used and is connected to either the open or closed pin depending on the state of the relay. Normally Open (NO) This pin is not normally connected to the Common pin. The relay must be energised for a connection to be made. Normally Closed (NC) This pin is connected to Common when the relay is not energised. Loading NC C NO Rail-Switch II uses electromechanical relays that are rated for 8A at 250 VAC when switching non-inductive loads. The product can be used to drive inductive loads, or those with high inrush currents, so long as external surge protection is added. These devices stop the contacts from being damaged by arcing. Part code Sequence-Filter is an external PTC filter suitable for this purpose. The user must also ensure that external circuit protection such as circuit breakers or fuses are connected in compliance with the local wiring regulations. Page 4

LED Indication Rail-Switch II has front-panel LED indicators for the following functions: Data (upper): OFF = no data received Green = DMX and RDM received Yellow = DMX only received Alternating green/yellow = Rail-Switch II is in preset playback mode or test mode (see Configuration below) Power/Locate (lower): Green = Power Flashing green = RDM locate is active An RDM locate sent to the root or the subdevices will have the identical effect of causing the power indicator to flash. Relays 1-6 (right-hand side): Blue = Relay is energised Configuration Rail-Switch II uses one channel to control each relay, requiring 6 channels in total. There are various configuration options (including start address programming). These are accessed using RDM, which requires a suitable programming interface. One option is Jump-Start, a handheld RDM programming tool available from Artistic Licence. Alternatively, Rail-Switch II can be connected to an Art-Net network using an interface product such as Art-Lynx O/P or Net-Lynx O/P. Configuration is then achieved using DMX-Workshop, a PC software application for managing Art-Net networks (available as a free-of-charge download from the Artistic Licence website, www.artisticlicence.com). DMX-Workshop This windows-based application provides a convenient means of accessing the Rail-Switch II configuration menus. DMX-Workshop can also be used for product firmware uploads. Start address programming In the DMX-Workshop Node List screen, Rail-Switch II appears as an RDM device, with each relay listed as a sub-device (see screenshot below). RDM device RDM sub-device If the user wishes all 6 output channels to be consecutively addressed, this is achieved by setting the RDM device start address (rightclick on the RDM device entry). Alternatively, if the user wishes to individually set the address of each channel, this is achieved by setting the start address of each sub-device (rightclick on the desired RDM sub-device). Generally, right-clicking on any entry brings up a menu of the available options. Preset mode It is possible to pre-programme Rail-Switch II such that it can be installed without a DMX controller. Rail-Switch II has 8 preset memories which can be used to record different on/off combinations of the six relay outputs. DMX-Workshop allows these settings to be captured and played back. To access the relevant menus, right-click on the Rail-Switch II RDM device (as shown above). Please note that the data captured is always the DMX512 input, independent of the currently selected output. Page 5

Preset playback is non-volatile. This means that if a preset is played back, Rail-Switch II can be then disconnected from DMX and power cycled and will still playback the preset. Data loss mode DMX-Workshop (or a suitable RDM tool) also allows programming of data loss mode. This mode is intended to be used when Rail-Switch II is being controlled by DMX (i.e. when it is not running in preset mode). The data loss programming determines what Rail-Switch II should do if DMX is lost for more than 2.5 seconds. It can be selected to play one of the 8 presets or hold the last state. If DMX returns, the control is immediately returned. Rail-Switch II will also power up in this mode until DMX is detected. To access the data loss mode menu, rightclick the Rail-Switch II RDM device, then go to Advanced - Artistic Licence products - Data loss mode. Test mode Rail-Switch II offer two test patterns: Test 1 = all outputs on Test 2 = all outputs off DMX-Workshop (or suitable RDM tool) can be used to put the product in test mode, which can be useful during show commissioning or rehearsals. To access the data test mode selections, right-click the Rail-Switch II RDM device, then go to Self test. Output priority The priority of output is as follows (highest at the top): 1. Test pattern 2. Preset playback 3. Data loss event 4. DMX512 Application Diagram The diagram below shows how Rail-Switch II could be utilised in a typical application. The DMX controller is not required if the Rail-Switch II has been preset programmed using RDM, or if it is in test mode. DMX controller DMX512 Rail-Switch II Live - Supply Live - Feed Neutral Earth DC power in It is recommended that inline current-limiting filters (e.g. Sequence-Filter) are used to protect the relays in Rail-Switch II for all inductive loads. Live - Feed Page 6

Rail-Switch II Specification Mechanical y Housing: DIN Rail Case y Material: Polycarbonate plastic, UL94-V0 rated y Overall dimensions: 90 mm (H) x 88 mm (W) x 62 mm (D) y Weight: 0.2 kg y Mounting: 35 mm DIN Rail or Surface Mount y Country of manufacture: UK Environmental y Operating temperature: 0 C to 40 C y Storage temperature: -10 C to +50 C y Operating relative humidity (max): 80% non-condensing y IP rating: IP20 indoor use only y Certification: CE, WEEE, RoHS y Warranty: 2-year (return to base) Power & Electrical y Input voltage: 9-24 VDC y Input connector: 2-pin pluggable screw terminal (1 no.) y Input power (max): 10 W y Duty cycle: 100% @ 25 C y DC fuse: internal resettable fuse for control electronics DMX512 input y Input mode: Non-isolated y Input ESD protection: 12 kv y Input voltage protection: +/- 80 V Outputs y Type: 6 x changeover relay, volt-free contacts y Connectors: 3-pin screw terminals (6 no.) y Maximum switching voltage: 250 VAC y Maximum peak current: 8A y Rated load (AC1 non-inductive): 2,000 VA y Rated load (AC15 inductive): 500 VA y Rated load (Single phase motor): 0.37 kw y Minimum load: 500mW y Protection: User supplied external protection y Isolation: 1 kv between relay contacts Control y Input Protocols: DMX512, DMX512(1990), DMX512-A y RDM V1.0 (E1.20-2006 ESTA Standard) Data Connection y 3-pin Screw Terminal DMX Input (1 no.) y 4-pin Screw Terminal DMX Loop / Term (1 no.) LED Indication y Power / DMX / RDM / Preset / Test / RDM locate / Relay Configuration y Jump-Start, DMX Workshop y Configurable settings include: --Start address (individual for each relay) --Preset, data loss and test modes Package Contents y Rail-Switch II y User guide Ordering Info y Product code: Rail-Switch II Accessories (not included) y PSU-24-2-DR Page 7

Compliance All Products manufactured or sold by Artistic Licence Engineering Ltd are fully compliant with the appropriate CE, FCC, and RoHS regulations. Product specific information is available on request. Waste Electrical & Electronic Equipment (WEEE) Artistic Licence is a member of a WEEE compliance scheme and will happily recycle any of our products that you, at your expense, return to us. CE Compliance Rail-Switch II is CE compliant when installed in a shielded and earthed metal case Warranty All products are covered from date of purchase by a two-year return to base warranty. By return to base, we mean that the customer is responsible for all costs of transport to and from Artistic Licence. Returns will not be accepted without prior authorisation. In order to discuss a request to return goods, please email: Sales@ArtisticLicence.com Safety Warning When Rail-Switch II is used for high current or voltages the unit shall be placed within a locked enclosure and shall be connected to the power by a qualified electrician. All relay connections that are used with high current or voltages shall be externally fused. This unit has not been designed for domestic use. Proper safety precautions need to be followed when using dangerous voltage or current levels. Artistic Licence The Mould Making Workshop Soby Mews Bovey Tracey TQ13 9JG United Kingdom Telephone +44 (0) 20 8863 4515 Email: Web: Sales@ArtisticLicence.com www.artisticlicence.com Support@ArtisticLicence.com Due to our policy of continuing product improvement specifications are subject to change without notice