CS5100DV Tech Sheet. Cal Spas. System PN System Model # VSP-CS5100DV-BCAH Software Version # 46 EPN # 3288

Similar documents
CS6300DV Tech Sheet. Cal Spas. System PN System Model # VSP-CS6300DV-BCAH Software Version # 45 EPN # 3092

CS6200DV Tech Sheet. Cal Spas. System PN System Model # VS5-CS6200DV-BCAH Software Version # 45 EPN # 3091

VS515Z Tech Sheet. Balboa Instruments. System PN System Model # VSP-VS515Z-YCAH Software Version # 43 EPN # 2816

VS501Z Hot Sheet. Balboa Instruments. System PN System Model # VSP-VS501Z-CCAH Software Version # 43 EPN # 2720

VS510SZ Tech Sheet. Balboa Instruments. System PN System Model # VSP-VS510SZ-DCAH Software Version # 43 EPN # 2765

VS520DZ Tech Sheet. Balboa Instruments. System PN System Model # VSP-VS520DZ-YCAH Software Version # 43 EPN # 2765

Balboa Water Group. System PN System Model # MM7-VS100-HCAK Software Version # 41 EPN # Base PCBA - PN PCB VS100 - PN Rev B

GS523DZ Tech Sheet. Balboa. System PN System Model # GS5-GS523DZ-RCA-3.0 Software Version # 43 EPN # 2808

VS501Z-4K Hot Sheet. System Model # VSP-VS501Z-CCAJ Software Version # 35 EPN # Base PCBA - PN PCB VS500Z - PN Rev C or D

VS510SZ Hot Sheet. System Model # VSP-VS510SZ-DCAH Software Version # 36 EPN # Base PCBA - PN PCB VS500Z - PN Rev C or D

GL2001 Mach 3 Tech Sheet Balboa Instruments

EL2000 Mach 3 Tech Sheet Balboa Instruments

EL2000 Mach 3 Hot Sheet

BFBP21 Tech Sheet. Customer: Bullfrog Spas. Part Number: X1 825 Incoloy Custom Box Overlay Box Overlay Part Number 46091

MS40E Tech Sheet. Customer: Master Spas. Part Number: kW 800 Incoloy Heater Custom Box Overlay Box Overlay Part Number N/A

BP21MS3B Tech Sheet. Customer: Balboa Water Group. Part Number: Incoloy 3kW Incoloy 3kW Titanium 3kW

BP21P4BC Tech Sheet. Customer: Balboa Water Group. Part Number: Incoloy 3kW Incoloy 3kW Titanium 3kW

BP6013G3 Tech Sheet Customer: Balboa Water Group Part Number:

BP2100G1 Tech Sheet. Customer: Balboa Water Group

BP601G1 Tech Sheet. Part Number: kW 800 Incoloy kW 825 Incoloy kW Titanium

System PN 53254_03 (Mach 2) Balboa Instruments

D/E Remote Relay Panel User Guide

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS

Manual. Water Vend Controller Model ESDI WARNING! ELECTRICAL SHOCK HAZARD! AUTHORIZED PERSONNEL ONLY. EXPOSED 120 VAC ON CIRCUIT BOARD

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

FOR SERVICE TECHNICIAN S USE ONLY

Ink-Dot Series II Driver

M-7 Technical Service Manual

FOR SERVICE TECHNICIAN S USE ONLY

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Thermometer / Barometer System

Remote Microprocessor Control Panel. for use with the. Redi-Purge. High Efficiency Purge System

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Part Numbers SNAP-IT-EMU1

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

TC-9102 Series Surface Mount Temperature Controllers

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

A0/A1 Controller Assembly Operation/Installation Manual READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.

UC-2000 Installation Manual Unicorn Computers Technology Limited

Integrated Battery Control System LBCS Step-by-Step Setup Guide

New 30AA and 31AA Electronic Motor Protection Modules. Application Bulletin 128

THE CTB08D LIGHT CONTOLLER

Mounting DIGITAL DISPLAY

Operating Instructions. For. Level Control Module. Model SSR 1000

Wireless Fixture Adapter (WFA100-SN) Installation Instructions

UCL & Color Logic. 4.0 LEDs. Installation Guide. LxCUSxxxxx, SP05xxLEDxxx & SP05xxSLEDxxx. Universal ColorLogic ColorLogic. 4.

EnCell Battery Cell Monitor

ES-600 Ozone Controller Operation Manual

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Safety Control Relay Product Catalog

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

B60 Domestic Voltage Optimisation Unit

TARA CONTROLS AGC-5. UCI Random Start USER S GUIDE. With Optional Warning Flashes for the Hearing Impaired. TARA CONTROLS by Cartessa Corporation

*740130* 2800, 9500 Series. Cable Companion Motor Power. Cable AC Power. Cable Retrofit Acessories

ADDENDUM FOR 20, 27, & 28 OPTIONS

SMART SHOT CONTROLLER FLUID USERS GUIDE

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Energy Management System. Operation and Installation Manual

Blue Box BLUE BOX TM LTD PARTS REPLACEMENT GUIDE

Section 09: Attached Optional Devices

Automation Interface Requirements for System I/O Interface of a DPC I Welding System

Beacon Power Supply Operating and Installation Instruction Manual

ETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

Test Asset Optimization Services Power Line Utilization Module (PLUM) DATA SHEET

OilCop Component Wiring Installation Manual

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

SmartVFD Frame 8 Wiring Diagrams and Dimensional Drawings

Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions

Quick Start Installation Guide

Power Supplies. Chapter The McGraw-Hill Companies, Inc. All rights reserved. Mike Meyers CompTIA A+ Guide to Managing and Troubleshooting PCs

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

PANEL MOUNT INTERCOMS

Model HM-535 Power Supply Installation and Service Instructions

WIRING INSTRUCTIONS FOR HENRY SIGNS CONCERNING THE JOHN HANCOCK SIGN

Digital Clamp-on Meter Instruction Manual

How To Help Electronic Equipment Survive The Storm

KBMG MULTI-SPEED BOARD

VCM Systems Vehicle Control Module Systems

User's Guide. Model W 3-in-1 Switching DC Power Supply

AC M2 OLED Meter Instructions PN 1836/ PN 1837 / PN 1838

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

Hardware User s Manual. Digital Video Motion Detector DVMD1-X

Dim levels for each system output may be controlled by any of the following methods:

INSTRUCTION MANUAL IM253 R0. AquaStart COMBINATION SOFT STARTERS START-UP MANUAL

Series SD-3PB Digital THERMOSTAT + TIMER

Series 3000V Input/Output Board

Transcription:

CS5100DV Tech Sheet Cal Spas System PN 55736-01 System Model # VSP-CS5100DV-BCAH Software Version # 46 EPN # 3288 Base PCBA - PN 55737-01 PCB VS500DVH - PN 23928 Rev A Base Panels VL260 PN 54754-03 with Overlay 12153 Template used: 40600_S.pdf 11/172008.pdf 01/21/2010 Page 1

System Revision History System PN EPN Date Requested By Changes Made 56736 3090 10.02.2009 Customer Initial release of Dual Voltage Heater Model 56736-01 3288 01.21.2010 BWG Add DIP switch to disable Pump 2 Page 2

Basic System Features and Functions Power Requirements System Outputs Setup 1 (As Manufactured) Setup 2 Additional Options and Spa-only Dolphin Remote K8 J2 W2 W3 A J2A U4 1 2 3 2 0 FUSE 8 3 J60 J22 J7 J8 J44 BALBOA INSTRUMENTS, INC. VS500Z P/N 22972 REV D 2-SPD EXT RLY EXT. RLY AUX. F SEN. A SEN. B VAC MADE IN U.S.A COPYRIGHT 2005 Page 3

G C Basic System Features and Functions Any time you change a DIP Switch, other than A1, you must reset Persistent Memory for your new DIP Switch Settings changes to take effect. If you do not reset Persistent Memory, your system may function improperly. To reset Persistent Memory: Power down by disconnecting power source from spa. Put a jumper across, covering both pins. (See illustration below) Power up by connecting power source to spa. Wait until is displayed on your panel. Power down again. Remove jumper from (May also move to cover 1 pin only) Power up again. About Persistent Memory and Time of Day Retention: This system uses memory that doesn t require a battery to store a variety of settings. What we refer to as Persistent Memory stores the filter settings, the set temperature, and the heat mode. Persistent Memory is not used for Time of Day. Only models with a Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the time. However, during power loss to the spa, the system will lose the correct time, and reset to 12:00 PM when power is restored. Power Up Display Sequence Upon power up, you should see the following on the display: Three numbers in a row, which are the SSID (the System Software ID). The third display of these numbers is the Software Version, which should match the version of your system. For example, if these three numbers are, that is a VS511SZ at version 38. Displayed next is: (indicating the system is configured for a heater between 3 and 6 kw) or (indicating the system is configured for a heater effectively* between 1 and 3 kw). should appear for all VS models running at 240VAC. should appear for all VS models running at 120VAC, as well as all GS models. (*A heater which is rated at 4 kw at 240VAC will function as a 1 kw heater at 120VAC.) will appear to signal the start of Priming Mode. At this point, the power up sequence is complete. Refer to the Reference Card for the VS or GS System model of your spa for information about how the spa operates from this point on, including how to adjust the Time of Day if using a Serial Deluxe style panel. E.GND K6 F4 FUSE.3A 250V J23 K1 W1 SWITCHBANK T1A K3 K2 F2 W4 E.GND J50 J6 SWITCHBANK A F7 7/26 S1 TST S1 W7 FUSE 20A 250V K8 K9 J46 J60 J22 J6 J7 J8 TST EXT. RLY J2 AUX. F SEN. A J47 W2 W3 A J2A SEN. B U4 J29 3 BALBOA INSTRUMENTS, INC. 2-SPD J44 VS500Z EXT RLY P/N 22972 REV D VAC MADE IN U.S.A COPYRIGHT 2005 on VS5xxZ and VS300 Series Main Board Shown. on GS5xxZ Series is located in approximately the same position. 1 2 3 2 J20 F1 0 FUSE 3A 250V 8 J26 J90 J50 LINE BLK AC W1 K4 K1 VS100 P/N 22964_B MADE IN U.S.A. 2006 PUMP T0.25A 250V Balboa J58 J23 NEUTRAL F2 J57 HEATER OZONE J29 WHT AC K3 J9 TST K2 SWITCHBANK A F4 J6 S1 TST SWITCHBANK A RST on VS100/GS100 Series Main Board Shown. J6 RST F5, F3A 250V 3 2 J7 SEN. A J8 SEN. B 8 U4 G J20 C Page 4

Wiring Configuration and DIP Settings Setup 1 (As Manufactured) K10 7/26 is a required device. Black Jumper Required. Do not remove. C J66 J65 N/O N/C CLASS G 30A FUSE F5 WHT AC NEUTRAL WHITE 6 J63 1 J25 J64 5 J61 J62 K1 BLK AC J74 K6 J23 F4 FUSE.3A 250V 2-Spd P1 Black jumper required. Do not remove. W1 J73 W4 T1 F7 FUSE 20A 250V J50 W10 1-Spd P2 7/26 W7 K8 K9 Ozone and Circ Pump must be the same voltage. Do not remove Fuse F7 (20A) J46 J47 W2 W3 A J29 Ozone J20 12V Light F1 0 FUSE 3A 250V K4 TORQUE RANGE FOR TB1: 27-30 IN. LBS. HOT BLACK HOT RED TB1 K3 K2 J2 J2A VS50x mode 2 3 1 U4 2 8 00 J32 J33 J34 J35 J36 Balboa J37 RED AC HTR2 01 HTR1 F2 E.GND SWITCHBANK A VAC J60 J22 J6 J7 J8 S1 TST EXT. RLY AUX. F SEN. A J44 SEN. B BALBOA INSTRUMENTS, INC. VS500Z P/N 22972 REV D To Safety Suction Switch MADE IN U.S.A COPYRIGHT 2005 2-SPD EXT RLY 3 5.5 kw Heater rated @ 240V (Approx. 1.4kW @ 120V) Do Not Use an Aux Freeze Sensor with this System. WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches. WARNING: Persistent Memory () must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page) SSID # 20 63 46 A1, Test Mode OFF A6, Safety Suction A2, Mode changes allowed A7, See Table 1 A3, Mini Panel A4, Pump 2 Enable A9, Circ Pump Off A5, Dual-Voltage Single Heat A10, See Table 1 2 VS50x Compatible 1 2 3 Memory Reset Wiring Color Key 120 Volt Connections 240 Volt Connections Black AC Jumpers 12 Volt Connections Relay Control Wires Board Connector Key 1 Typically Line voltage 2 Typically Line voltage for 2-speed pumps 3 Neutral (Common) 4 Ground Note flat sides in connector Page 5

DIP Switch and Jumper Definitions SSID 20 63 45 DIP Switch Key A1 Test Mode (normally OFF) A2 ON position: Standard mode only OFF position: Std/Ecn/Sleep mode changes allowed A3 ON position: use Mini Panel * OFF position: use Digital Duplex or Light Duplex panel A4 ON position: Pump 2 Disabled OFF position: Pump 2 Enabled A5 ON position: Dual-Voltage Heating enabled OFF position: Single-voltage heating (240VAC only) A6 Safety Suction (must be OFF) A8 ON position: temperature is displayed in degrees Celsius OFF position: temperature is displayed in degrees Fahrenheit A9 "ON" position: Circ Pump act like Pump1 low-speed (filter cycle, polls) Pump 1 is one speed "OFF" position, no circ pump. Pump1 is two-speed A7+A10 Control amp draw requirements (See Table 1) Note: System is 60Hz only. Base Model VS501Z Alert: Blower or 1-speed Pump 2 is required, connect to 7/26. For no Blower and no Pump 2, use VS500Z or VS515Z. Table 1 Number of Hi-Speed Pumps that can Run Before Heater is Disabled (A5 OFF) OR Before Heater runs at 120VAC (A5 ON) A7 A10 # of H.S.Pumps OFF OFF 0 ON OFF 1 OFF ON 2 ON ON 3 * Panels with button layout are not compatible when A3 is ON. Jumper Key 2 Factory set. DO NOT MOVE. Jumper must be on Pins 1 and 2 for VS51xZ/VS52xZ/VS5xxSZ/VS5xxDZ software. Jumper must be on Pins 2 and 3 for VS50xZ software. When jumper is placed on 2 pins during power-up, system will reset persistent memory. Leave on 1 pin only to enable persistent memory feature. WARNING: Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components. Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system. Contact Balboa if you require additional configuration pages added to this tech sheet. Panel Button Positions A3: OFF 1 2 3 4 1 4 2 3 A A3:ON 1 2 3 4 A Panel Button Assignments 1=7/26 (Unused if A4 is ON) 2=Pump 1 3=Temp 4=Light Page 6

Configuration Notes 2 pumps 8.0A max each = 16A 5.5 kw heater at 240V = 23A nominal 5.5 kw heater at 120V = 11.5A nominal No A/V On 32A service (40A breaker): A5 ON (heater at 120V can run with both pumps on high) A7 OFF & A10 OFF (heater at 240V cannot run with even one pump on high if other pump is on low) On 40A service (50A breaker) or 48A service (60A breaker): A5 ON A7 ON & A10 ON (heater at 240V can run with all pumps on high) Page 7

W W Ozone Connections Ozone Connector Voltage: The VS500Z circuit board is factory configured to deliver a preset voltage (120V or 240V) to the on-board ozone connector (J29). See the ratings table on the wiring diagram attached to the cover of the enclosure for the configured voltage. For 240V output W2 connects to Red AC and for 120V output W2 connects to White AC. The voltage to the ozone connector can be changed in the field if required. W2 just needs to be set for the required voltage. WARNING: Changing the voltage of the ozone connector also effects the voltage supplied to the circ pump connector (J47). Any equipment controlled by that connector may be damaged if the wrong voltage is selected. Balboa Ozone Generator: If the board is set up to operate a 120V ozone generator, the connector on the ozone generator is likely to be configured correctly, but should be compared to the illustration below. If a 240V ozone generator is required, be sure the red wire in the ozone cord is positioned in the connector next to the green ground wire as described below. Note: A special tool is required to remove the pins from the connector body once they are snapped in place. Check with your Balboa Account Manager for information on purchasing a pin-removal tool. Balboa Ozone connector configuration for 120V 60Hz Line - Black conductor Use this slot for the leftover Red conductor Common - Install the White conductor here for 120V ozone Ground (Green) conductor B G Balboa Ozone connector configuration for 240V 60Hz Line - Black conductor Use this slot for the leftover White conductor Common - Install the Red conductor here for 240V ozone Ground (Green) conductor Flat sides of sockets as shown B G FUSE 20A 250V J46 J47 J29 K8 Circ.Pump G W B R W2 W3 A J20 12V Light F1 FUSE 3A 250V Line - Black conductor Use this slot for the leftover conductor Common - Red for 240V or White for 120V ozone (See W2 wire) Ground (Green) conductor W2 wire determines voltage 0 Page 8

Duplex Panel Configurations VL260 PN 54754-03 with Overlay PN 12153 Connects to Main Panel terminal SETUP 1 SETUP 1 VL260 PN 55354-04 with Overlay PN 12154 Connects to Main Panel terminal Page 9