User Guide. Tracer CH535 Chiller Controller on models CGAX/CXAX. CG-SVU007B-GB Original instructions

Similar documents
User Guide. FreeCool : Free Cooling unit V1.1 ENGY-SVU001A-GB

User Guide. For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units. CNT-SVU005C-GB Original instructions

User Guide. Multipipe Units CMAA / RTMA CNT-SVU004B-GB

pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

Product Catalog. Tracer Controls Tracer ZN517 Unitary Control BAS-PRC012-EN. August 2010

ADDENDUM WCFX. Vision 2020i Touch Screen Controller. - a1 - Vision 2020i Controller

4-step Chiller and Heat Pump Controller

Temperature control unit

UNIT CONTROLLER 8 (UC8) Modbus RTU communications

USER'S GUIDE BARD-LINK TM LC /LC SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL

Temperature controller Ducted systems

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

UNIT CONTROLLER 7 (UC7) Operation & Installation. Hydronic Units

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

Mercury T Controller Installation & User Guide

M1000 INTELLIGENT ZONE CONTROL SYSTEM

ESC 201. Installation and Operating Instructions Manual. SG Jan 2015

BACVIEW MANUAL Software Version 3.06 INSTALLATION AND OPERATION MANUAL

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

Trane Controls. Smart Solutions for Smart Buildings

User manual CLIMATIC 50 - CHILLERS

V0STAT51P-2 Programmable Wired Controller

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

RGX COMMUNICATIONS GATEWAY

CommandCenter Operator Panel

Introduction. To use Carrier wireless sensors, you must have: A i-vu v6.5 or later system v6-00 or later drivers

OM Operation and Maintenance Manual. Intelligent Equipment for Daikin Applied Trailblazer Air-cooled Scroll Chiller. Models: AGZ-D and AGZ-E

REMOTE CONTROL MYSYSTEM

TECHNICAL MANUAL WATER 300 C 5300 CV/06-00 GB

WavePRO Wireless Programmable T2500 Thermostat & R2500 Receiver OPERATING MANUAL. Model K

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

Modbus Integration Integration for Modbus Functionality for VTR8300 Series

FCU-4 FAN COIL CONTROLLER

Products no longer available

Installation and Operation Manual SPC1

WSHP-IOP-2 May Installation, Operation, and Programming. Tracer ZN510 Controller

ML Twin Compressor Controller Installation & User Guide

I/O module (Expansion module)

TECHNICAL REFERENCE MANUAL FOR CAREL CONTROLLERS

FX2-CHILLER. Digital Control. Operations Manual

Field module for cold locations for installation in refrigerators for direct control of a pulsed expansion valve

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

Parallel SelfSensing Modulating Pump Controller

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions

BACnet MS/TP Interface User s Guide

Controllers for compressor racks with advanced energy saving. PN08 September 2016

Dual Digital Module Technical Guide

idigit CONTROL INSTALLER MANUAL Digital thermostat for fan coil units Rev100

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51

ML Multi Stage Thermostat Installation & User Guide

programmable controllers pco Sistema: pco pco 5 + Programmable controller for HVAC/R applications carel.com

Quick Start Guide DDC (2014/02) Subject to change without prior notice Quick Start Guide

clarity 3 Programmable Controller

Mercury 11-10PV Pack / Condenser Controller Installation & User Guide V6 or Higher

UCU Room Display. Operation Modes. Features. Applications DATASHEET

Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q

Temperature Controller (Heat Pumps)

RAMSES D GB F NL. Installation and operating instructions Room thermostat. RAMSES 832 top2

TPE, TPED Series 2000

pco 3 universal stage controller User manual Manual version: 1.1 of 24/11/09 Program code: FLSTDmIU0F Integrated Control Solutions & Energy Savings

pco5 Overview February 2010 Air Conditioning Business Unit pco5 Overview slide n. 1

Application software for pco 1 / pco 2 / pco xs. Standard Compressor Packs. Program code: FLSTDMFC0A

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

MicroTrans EQ Signal Processor. Operation & Maintenance Manual

MCS-CONNECT Quick Guide to Features

Model: EP210. Dual channel programmable controller. Installation Manual

User Guide. Tracer TD7 with UC 800 for CGAF chillers. CG-SVU010A-GB Original instructions

FrigoPack FU+ New Generation of Intelligent Refrigeration Inverters

Adaptive Frequency Drive Superior Chiller Performance

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

SEZ7656R1045B / SEZ7656H1045B

HARDWARE GUIDE. Water Loop Controller C1000 Series. Specifications and Operational Guide

Quick Start Guide. Variable Speed Drive. Part Number: Issue: 3

THERMOSTATS & CONTROLLERS

TS110 DISPLAY MANUAL Pro Refrigeration, Inc

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

INTRODUCTION. FX-1 Operations Manual. Standard Features. Optional Features. Read This Manual Completely Before Proceeding!

CTC Low Temperature Process Chillers

MODELS: STEAM FIRED YPC-ST-14SC & YPC-ST-16SL Thru YPC-ST-19S

Touchpad User Guide. National Sales. Product Support. Freecall: Ph:

Modbus communication module for TCX2: AEX-MOD

Product Manual SZ2141

ACDU01A Communicating Service Tool

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

CONTROLLER INSTALLATION OPERATION & QUICK START

Model: Available in : Sapphire Black and Glacier White

Model: Available in : Sapphire Black and Glacier White

Component Troubleshooting

CGWN/CCUN indoor liquid chillers The compact AquaStream² solution

FX 2 Instruction Manual

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module

Installation Manual Stand-Alone Metering for OptiPlant

Interfaces for Local Override Operation

FCU-4 FAN COIL CONTROLLER

Transcription:

User Guide Tracer CH535 Chiller Controller on models CGAX/CXAX CG-SVU007B-GB Original instructions

Table of Contents General information...4 Tracer CH535 Presentation...5 Tracer CH535 Hardware...7 Tracer CH535 Extention Hardware...8 Tracer CH535 module connections Terminals...9 Alarms... 10 User interface display...15 2 2015 Trane CG-SVU007B-GB

CG-SVU007B-GB 3

General information Foreword These instructions are given as a guide to good practice in the installation, operation and periodic maintenance by the user of TRACER CH535 chiller controller. They do not contain the full service procedures necessary for the continued successful operation of this equipment. The services of a qualified service technician should be employed, through the medium of a maintenance contract with a reputable service company. Warranty Warranty is based on the general terms and conditions of the constructor. The warranty is void if the equipment is modified or repaired without the written approval of the constructor, if the operating limits are exceeded, or if the control system or the electrical wiring is modified. Damage due to misuse, lack of maintenance, or failure to comply with the manufacturer s instructions, is not covered by the warranty obligation. If the user does not conform to the rules of Maintenance, it may entail cancellation of warranty and liabilities by the constructor. Reception When the unit arrives on site, check it has not been damaged in any way during transport. If damage is observed, or even merely suspected, notify the carrier within 24 hours by registered letter. Notify the local Trane Sales office at the same time. The unit should be totally inspected within 3 days of delivery. If damage is observed, notify the last carrier by registered letter and notify the local sales office. General information About this manual Cautions appear at appropriate places in this instruction manual. Your personal safety and the proper operation of this machine require that you follow them carefully. The constructor assumes no liability for installations or servicing performed by unqualified personnel. 4 CG-SVU007B-GB

Tracer CH535 Presentation Important note: This document describes all the functions available on TRACER CH535 with software version 1.x and explains how to program it. Certain parameters must only be modified by qualified personnel. Before changing any parameter, always check that the change does not affect the good and safe operation of the equipment. Operation must always stay within the catalogued limits. Tracer CH535 is a programmable microprocessor electronic controller dedicated to handle safe and optimized operation of the scroll compressor chiller, series Conquest, only cooling (CGAX) and heat pumps (CXAX). Module description Figure 1 Programmable microprocessor electronic controller A = plan Address selection key B = plan Address display C = Power Supply Presence LED D = Overcharge LED E = Fieldbus/BMS on port J26 micro switch F = USB host (master ) port G = USB slave (device) port Each controller is provided with connectors for the inputs/output and the plan address display, which has a button and a LED for setting the plan address. CG-SVU007B-GB 5

Tracer CH535 Presentation LED Tracer CH535 provides 6 LEDs: 1 yellow LED indicating that the device is powered; 1 red LED indicating an overload on the +VDC (J2-5) terminal; 4 LEDs indicating valve status: Flashing LEDs mean the valve is moving; steadily-on LEDs mean the valve is completely open or closed. Table 1 LED descriptions LED Colour Description A Yellow Close A (connector J27) B Green Open A (connector J27) C Yellow Close B (connector J28) D Green Open B (connector J28) Micro switches Four micro switches are provided to configure port J26 as a Fieldbus or BMS port. They must not be modified (Fieldbus mandatory). USB ports There are 2 USB ports which can be accessed after removing the cover: A host USB port for connecting pen drives; A slave USB port for direct connection to the USB port of a computer on which pcomanager is installed, which can be used to upload the application program, commissioning the system, etc. Serial ports Table 2 Serial port descriptions Serial Type/connectors Features Serial ZERO plan/j10, J11 Built into main board HW driver: asynchronous half duplex RS485 plan Not optically isolated Connectors: telephone jack + 3-pin plug-in connector Serial ONE Serial TWO Serial THREE Serial FOUR BMS 1 Serial Card Field Bus 1 Serial Card BMS 2 / J25 Field Bus 2 / J26 For standard display connection Not built into main board HW driver: not present Can be used with all the BMS expansion cards of the Tracer CH535 family For Modbus, BACnet, LonTalk, Web connections Not built into main board HW driver: not present Can be used with all Fieldbus expansion cards of the Tracer CH535 family Not used Built into main board HW driver: asynchronous half duplex RS485 slave Optically-isolated/non-optically-isolated serial 3-pin plug-in connector For Deluxe display connection Built into main board HW driver: asynchronous half duplex RS485 Master or Slave (see par. 3.2) J26: optically isolated/not optically isolated 3-pin plug-in connector For Tracer CH535 ext connections 6 CG-SVU007B-GB

Tracer CH535 Hardware Built-In driver module connections terminals Figure 2 Built-in driver terminal locations C1 NO1 NO2 NO3 C1 C4 NO4 NO5 NO6 C4 C7 NO7 C7 NO8 C8 NC8 J12 J13 J14 J15 J16 J17 J18 C9 NO9 1 3 J11 plan NO10 2 NO11 4 C9 1 NO12 3 C12 2 NC12 4 10 11 12 13 14 15 NO13 C13 NC13 J10 4 3 2 1 J25 BMS2 J26 FBus2 J27 J28 16 17 18 20 21 22 24 23 driver Fie ldb us card B M S card J30 VBAT G0 G A B C D GND VREF S1 J29 S2 S3 S4 DI1 DI2 G J1 J24 J2 J3 J4 J5 G0 +Vterm GND +5 VREF U1 U2 U3 GND +VDC U4 GND U5 GND VG VG0 Y1 Y2 Y3 Y4 ID1 ID2 ID3 ID4 ID5 ID6 ID7 ID8 IDC1 U6 U7 J6 U8 GND J7 ID9 ID10 ID11 ID12 IDC9 ID13H ID13 IDC13 ID14 ID14H J8 1 2 3 4 3 5 6 7 8 3 8 9 1 = Power Supply connection (G (+), GO (-) ) 2 = +Vterm: additional terminal power supply -VREF power supply for rasiometric probes 3 = Universal Input / Outputs 4 = +VDC: power supply for active probes 5 = plan address setup key, secondary display LED 6 = VG: power supply voltage A for options VG0: power supply for optically isolated analog output at 0 Vac/Vdc 7 = Analog ouputs 8 = ID: digital inputs at low voltage 9 = ID..: digital inputs at low voltage IDH..: digital inputs at high voltage 10 = plan telephone connector for terminal/download application programme 11 = plan removable connector 12 = Reserved 13 = Reserved 14 = Reserved 15 = Relay digital outputs CG-SVU007B-GB 7

Tracer CH535 Extention Hardware Figure 3 CH535 extention terminal locations 8 B1 B2 GND +5VRef NO1 C1 NC1 NO2 C2 NC2 NO3 C3 NC3 NO4 C4 NC4 7 +Vdc B3 B4 GND +5VRef +Vdc 4 G ID1 G0 ID2 ID3 ID4 VG IDC1 VG0 Y1 GND T+ T- 6 1 2 5 3 1 = Power Supply connection (G (+), G0 (-)) 2 = Optically-isolated analog output, 0 to 10 V 3 = RS485 network connector (GND, T+, T-) 4 = Optically-isolated digital inputs, at 24 Vac/Vdc 5 = Yellow power LED and 3 indicator LEDs 6 = Serial address 7 = Analog inputs and power to probes 8 = Relay digital outputs 8 CG-SVU007B-GB

Tracer CH535 module connections Terminals TRACER CH535 offers customer the possibility to use inputs or outputs in order to: use an external water setpoint reset using an analog input (option), use an auxiliary setpoint (option), connect a remote on/off of the circuit/unit (standard), connect a remote Cooling/Heating switch (standard), return a circuit fault (option), receive unit capacity percent (option). Note: External water setpoint based on an external signal input (0-20mA or 4-20mA), it will be possible to offset the active setpoint from 0 C to 20 C. This function can be used in conjunction with the automatic setpoint reset function. Water setpoint 1 5 Ambient 2 temperature 3 4 Table 3 External demand limit setpoint allowances Nb of CMP allowed Percent Current 0-20mA Simplex Duo Simplex Trio Duplex 0.0% 0 1 1 1 25.0% 5 1 1 2 33.3% 6.66 1 2 2 50.0% 10 2 2 3 66.7% 13.34 2 3 3 75.0% 15 2 3 4 100.0% 20 2 3 4 Percent Current 4-20mA Simplex Duo Nb of CMP allowed Simplex Trio Duplex 20.0% 4 1 1 1 40.0% 8 1 1 2 46.7% 9.33 1 2 2 60.0% 12 2 2 3 73.4% 14.67 2 3 3 80.0% 16 2 3 4 100.0% 20 2 3 4 1 = Leaving water temperature setpoint 2 = Minimum value 3 = Maximum value 4 = Reset = 20 C 5 = Active setpoint Note: External demand limit setpoint based on an external signal input (0-20mA or 4-20mA), it will define the number of compressors allowed to start. CG-SVU007B-GB 9

Alarms Alarms display and resetting A fault on a unit will be shown through the user interface or through 2 digital outputs, one for each refrigerant circuit. The alarms are divided into 3 categories: Warning: Shows that something is wrong on the unit but unit can be kept in operation. A message is displayed on the user interface screen. These messages are not recorded in the history list. Fault with automatic reset: when the cause of the fault disappears, the fault is cancelled and unit operation will return to normal. The messages displayed on the user interface screen disappear but are recorded in the history list of faults. The fault is relayed through the digital output if I/O parameter is set to show a circuit fault. Fault with manual reset: when the cause of the fault disappears, a manual reset is required to restart the unit. The messages displayed on the user interface screen disappear and are recorded in the history list of faults. The fault is relayed through the digital output if I/O parameter is set to show a circuit fault. Should an alarm occur, will be lit in red. Pressing once will display the alarm message (refer to Table 6 for possible messages) When alarm message is displayed press the default if necessary. to reset 10 CG-SVU007B-GB

Alarms Table 4 - Status, Warning and Alarm messages N Message Reset Type Unit Status Description 1 No Alarm - Unit On See unit status on Main display 2 Alarm Water Pump1 Unit On Defective water pump 1 3 Alarm Water Pump2 Unit On Defective water pump 2 4 User Ckt1 Stop - Circuit 1 Off Circuit 1 Disable by Settings (via keyboard) 5 User Ckt2 Stop - Circuit 2 Off Circuit 2 Disable by Settings (via keyboard) 6 Ext. Ckt1 Stop - Circuit 1 Off Circuit 1 Off by Digital Input (Duplex units) 7 Ext. Ckt2 Stop - Circuit 2 Off Circuit 2 Off by Digital Input (Duplex units) 8 Rem. Ckt1 Stop - Circuit 1 Off Circuit 1 Disable by Supervision 9 Rem. Ckt2 Stop - Circuit 2 Off Circuit 2 Disable by Supervision 10 Clock Unit Stop - Unit Off Unit Off by Program (Hourly, Weekly) 11 Operator Stop - Unit Off Unit Off by Operator (via keyboard) 12 Phase Fault Auto Unit Off Phase Loss or Phase Reversal 13 Warning Ckt1 LP Limit Auto Circuit 1 Limit Suction pressure on circuit 1 is below the setpoint (1.5barG). 14 Warning Ckt2 LP Limit Auto Circuit 2 Limit Suction pressure on circuit 2 is below the setpoint (1.5barG). 15 Warning Ckt1 HW Limit Auto Circuit 1 Limit Leaving water temperature is above the setpoint (Default value: 25 C). 16 Warning Ckt2 HW Limit Auto Circuit 2 Limit Leaving water temperature is above the setpoint (Default value: 25 C). 17 Warning Ckt1 HP Limit Auto Circuit 1 Limit Discharge pressure on circuit 1 is above the setpoint (Default value: 43.1barG). 18 Warning Ckt2 HP Limit Auto Circuit 2 Limit Discharge pressure on circuit 2 is above the setpoint (Default value: 43.1barG). 19 Warning Ckt1 HT Limit Auto Circuit 1 Limit Discharge temperature on circuit 1 is above the setpoint (Default value: 128 C). 20 Warning Ckt2 HT Limit Auto Circuit 2 Limit Discharge temperature on circuit 2 is above the setpoint (Default value: 128 C). 21 Warning Ckt1 CIPD Limit Auto Circuit 1 Limit Compressor Involute Pressure Differential on circuit 1 is above 22.2barG or above 18.6barG during 25min. 22 Warning Ckt2 CIPD Limit Auto Circuit 2 Limit Compressor Involute Pressure Differential on circuit 2 is above 22.2barG or above 18.6barG during 25min. 23 Warning Low SuperHeat ckt1 Auto Circuit 1 Off Super Heat on circuit 1 is below low limit (2 C) 24 Warning Low SuperHeat ckt2 Auto Circuit 2 Off Super Heat on circuit 2 is below low limit (2 C) Alarm Outside Air Temp Ambient temperature is out of range for unit operation: 25 Cooling: Too Low Auto Unit Off Cooling mode: below -10 C (default value) Heating: Out of Range Heating mode: below -15 C (default value) or above 29 C. 26 Ckt1 Defrost - Unit On Defrost on Circuit 1 CG-SVU007B-GB 11

Alarms N Message Reset Type Unit Status 27 Ckt2 Defrost - Unit On Defrost on Circuit 2 28 Alarm Loss of Water Flow Auto Unit Off 29 Alarm Air Sensor Auto Unit Off 30 Alarm Water In Sensor Auto Unit Off 31 Alarm Water Out Sensor Auto Unit Off 32 Alarm HT Sensor Ckt1 Auto Circuit 1 Off 33 Alarm HP Sensor Ckt1 Auto Circuit 1 Off 34 Alarm HT Sensor Ckt2 Auto Circuit 2 Off 35 Alarm HP Sensor Ckt2 Auto Circuit 2 Off 36 Alarm PHR LWT Sensor Auto Unit On 37 Alarm PHR EWT Sensor Auto Unit On 38 39 Alarm Ext. Water SP Signal Alarm Ext. Demand Limit SP Signal 40 Alarm Fan1 fault Ckt1 41 Alarm Fan1 fault Ckt2 42 Alarm LP Ckt1 Fault 43 Alarm LP Ckt2 Fault Auto Auto Auto / Auto / Auto / Auto / Description Loss of water flow for more than 1 sec. Pump restarts by a manual unit mode changeover Faulty sensor, out of range -30..+80 C (short circuit or open circuit) Faulty sensor, out of range -30..+80 C (short circuit or open circuit) Faulty sensor, out of range -30..+80 C (short circuit or open circuit) (short circuit or open circuit) Faulty sensor, out of range -30..+150 C (short circuit or open circuit) Faulty sensor, out of range 1..46Bar (short circuit or open circuit) Faulty sensor, out of range -30..+150 C (short circuit or open circuit) Faulty sensor, out of range 1..46Bar (short circuit or open circuit) Faulty sensor, out of range -30..+80 C (short circuit or open circuit) Faulty sensor, out of range -30..+80 C (short circuit or open circuit) Faulty signal, out of range 0..20mA or 4..20mA Unit On following configuration Faulty signal, out of range 0..20mA or 4..20mA Unit On following configuration Circuit 1 On (Off if only one The 1st fan on the circuit 1 is faulty fan) Circuit 2 On (Off if only one The 1st fan on the circuit 2 is faulty fan) Suction pressure on circuit 1 is below the setpoint. Circuit 1 Off reset after 3 faults within 1 hour Suction pressure on circuit 2 is below the setpoint. Circuit 2 Off reset after 3 faults within 1 hour 44 Alarm Comp. 1A Fault CMP 1A Off CMP 1A is faulty 45 Alarm Comp. 1B Fault CMP 1B Off CMP 1B is faulty 46 Alarm Comp. 1C Fault CMP 1C Off CMP 1C is faulty 47 Alarm Comp. 2A Fault CMP 2A Off CMP 2A is faulty 48 Alarm Comp. 2B Fault CMP 2B Off CMP 2B is faulty 12 CG-SVU007B-GB

Alarms N Message 49 50 51 52 53 Warning Comp.1A Maintenance Warning Comp.1B Maintenance Warning Comp.1C Maintenance Warning Comp.2A Maintenance Warning Comp.2B Maintenance Reset Type Unit Status Unit On Unit On Unit On Unit On Unit On Description Compressor running hours above the threshold defined in unit configuration. Each compressor start is equal to 3 running hours. 54 Alarm HT Ckt 1 Fault Circuit 1 Off High Discharge Temperature Fault on Ckt1 55 Alarm HT Ckt 2 Fault Circuit 2 Off High Discharge Temperature Fault on Ckt2 56 57 58 59 60 61 62 Alarm CMP Involute Press Diff Ckt 1 Alarm CMP Involute Press Diff Ckt 2 Alarm Low Sat Suction Temp Ckt 1 Alarm Low Sat Suction Temp Ckt 2 Alarm Low SuperHeat Ckt1 Alarm Low SuperHeat Ckt2 Alarm Low water temperature Circuit 1 Off Circuit 2 Off High CMP Involute Pressure Differential Fault on Ckt1 High CMP Involute Pressure Differential Fault on Ckt2 Circuit 1 Off Low Suction Saturated Temperature Fault on Ckt1 Circuit 2 Off Low Suction Saturated Temperature Fault on Ckt2 Circuit 1 Off Circuit 2 Off Unit Off Low Super Heat warning on circuit 1 occurred three times in one hour Low Super Heat warning on circuit 2 occurred three times in one hour LWT < antifreeze or INT (antifreeze- EWT)<=10 Cxsecond 63 Alarm HP Ckt1 Fault Circuit 1 Off High Pressure Cut-Out circuit 1 64 Alarm HP Ckt2 Fault Circuit 2 Off High Pressure Cut-Out circuit 2 65 66 Alarm Ckt 1 Fault (1st fan or all CMP) Alarm Ckt 2 Fault (1st fan or all CMP) Circuit 1 Off Circuit 2 Off 67 Alarm Unit Fault Unit Off Simultaneous faults on compressors 1A and 1B (1A, 1B and 1C for units #36, #39 and #45) or Fan 1 Fault Ckt1 for units #7 to #20, #35 and #40. Simultaneous faults on compressors 2A and 2B or Fan 1 Fault Ckt2 for units #7 to #20, #35 and #40. Simultaneous faults on Ckt1 and Ckt2 on duplex units 68 Alarms pcoe 5 offline Auto Unit On pcoextension5 is offline 69 Alarms pcoe 5 Analog input 1 Auto Unit On pcoextension5 is in default on Analog input #1 70 Alarms pcoe 5 Analog input 2 Auto Unit On pcoextension5 is in default on Analog input #2 71 Alarms pcoe 5 Analog input 3 Auto Unit On pcoextension5 is in default on Analog input #3 72 Alarms pcoe 5 Analog input 4 Auto Unit On pcoextension5 is in default on Analog input #4 CG-SVU007B-GB 13

Alarms N Message Reset Type Unit Status Description 73 Alarms pcoe 5 IO mismatch Auto Unit On pcoextension5 is in default on Analog input #4 74 Alarm Drive Fault Unit Off Variable Primary Flow Drive fault 75 76 77 Alarm Low Differential Pressure ckt1 Alarm Low Differential Pressure ckt2 Warning Cutout Supp Heating Auto Auto Auto Circuit 1 Off Circuit 2 Off Unit On Low Differential Pressure on circuit 1 (High Pressure - Low Pressure) Low Differential Pressure on circuit 2 (High Pressure - Low Pressure) Information that Supplemental Heating is in cut out 78 Warning LRTC limit ckt1 Auto Circuit 1 Limit Low Refrigerant Temperature cut-out on circuit 1 79 Warning LRTC limit ckt2 Auto Circuit 2 Limit Low Refrigerant Temperature cut-out on circuit 2 80 Warning Sequencer Comm. Lost Auto Unit On Faulty plan communication (Smart Sequencer) 81 EVD EVO EXV synchro Please wait Auto Unit Off Expansion Valve is currently initiating 14 CG-SVU007B-GB

User interface display Figure 4 LCD Display Table 5 Button functions Button Description Backlighting Function 1 Alarm White / Red 2 Prg White / Yellow Access to sub-menus 3 Esc White Return to high level Pressed together with UP and power supply allows the controller address to be changed Pressed together with ENTER accesses the BIOS page 4 Up White Pressed together with DOWN or ENTER allows the terminal address to be changed Increase value 5 Enter White Confirm value 6 Down White Pressed together with UP and ENTER allows the terminal address to be changed Decrease value 2 + 5 Language White Pressed together PRG and ENTER allows the terminal language to be changed Note: In addition to the menu definition, the setting range (within parenthesis or bold for discrete data) and the default value (underlined) of each parameter are indicated: CG-SVU007B-GB 15

User interface display Figure 5 - Deluxe touchscreen display Button Description Function 1 Alarm 3 Esc Return to Main screen 7 Reports Display status of unit component. Multiple pages toggle up/down possible through arrow button located on bottom right side of the screen 8 Data Graph Graphical color data logging display on graphs. 4 predefined graphs available. 9 Settings Adjustment of Unit setpoints, parameter, configuration, scheduling. 10 Language Toggle through different display languages. 11 Auto/Stop Toggle unit in AUTO or OFF mode. 12 Back Return to previous windows 13 Brightness Toggle through 3 level of back light brightness levels. 16 CG-SVU007B-GB

User interface display Access to sub-menus Access using the Prg key Data display sub-menu Settings sub-menu Daily/weekly program sub-menu Unit configuration sub-menu (accessible to Trane technicians only, not accessible to end users) The sub-menu will be selected using the Up and Down keys and selected using the Enter button. Data display menu Show status and values of: Temperature sensors Pressures sensors Compressors Fans Pump package Expansion valve Auxiliary heat Operating modes Setpoints Setting menu Show status and allows modification of: Local and auxiliary setpoints Setpoint offset Operating modes Circuit manual lockout Clock menu Show status and allows modification of: Actual date and time adjustment Scheduling Figure 6 Scheduling Monday Tuesday Wednesday Thursday Friday Saturday Sunday Weekly schedule Start ------------ ------------ ------------ Stop Unit Status Unit ON Unit ON Unit ON Unit ON Unit ON Unit OFF Unit OFF 00:00 03:00 06:00 09:00 12:00 15:00 18:00 21:00 00:00 Daily Schedule Start ------------ ------------ ------------ Stop Unit Status Unit OFF Unit OFF Unit ON Unit ON Unit ON Unit ON Unit ON Unit OFF Unit OFF Example of scheduling where unit is running from Monday to Friday in a time frame from 6:00 to 18:00 CG-SVU007B-GB 17

User interface display Exemple of hourly scheduling 00:00 03:00 06:00 09:00 12:00 15:00 18:00 21:00 00:00 Zone #1 Zone #2 Zone #3 Zone #4 Unit active cooling setpoint Start CSP 10 C Start CSP 7 C Start CSP 10 C Start CSP 15 C 15 C 15 C 10 C 7 C 7 C 7 C 10 C 15 C 15 C Example of hourly setpoint scheduling where unit is delivering 15 C water during the night and 7 C during peak period of the day (from 9:00 to 15:00). Occupied zone from 6:00 to 21:00. Configuration menu Shows and allows modification of unit configuration with 2 user levels (Local technician and Trane service technician): Local technician (by default password = 0005) allows to: Show status display version application Modification of pump timers, freeze protection and other limits Force defrost cycle Show status of digital and analog inputs/outputs, override of expansion valve. Modification of local technician password. plan Address Configuration for Smart Sequencer usage Sequencer feature allows control up to three units through plan network. Each unit must be configured with a unique plan address. Unit equipped with PGDTouch is set at address #1. This unit is the master chiller. The slave unit(s) must be configured with plan address #2 (and #3). This can be done through Sequencer dedicated Configuration sub-menu. By default, the address #1 is set in this menu. Increasing it at #2 (or #3) will then interrupt the link with PGD1 display. Thus, after modifying the plan address, the PGD1 display must be configured to communicate with the address modified controller. To do it, press buttons UP, ENTER and DOWN together during few seconds until the following screen appears on PGD1: 32 01 18 CG-SVU007B-GB

User interface display Modify the Display address setting from 32 to 31 (for plan address #2), or 30 (for plan address #3). By validating this change, you will get the following screen: Then after pressing enter again, the next screen has to be configured as follow (31 or 30 as per above selection) 31 Pr And validate the last field to YES. PGD1 is now configured to communicate with a controller having plan address #2 (or #3). To update Application Software on Controller, it is mandatory to: First, disconnect plan network wire on controller to be updated Restore plan address #1 on this controller And finally execute software update process When the software is updated, then we can configure the ad-hoc plan address on controller (and PGD1 setting as per here above procedure), then reconnect plan network wire. CG-SVU007B-GB 19

Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services and parts. For more information visit www.trane.com 2015 Trane All rights reserved CG-SVU007B-GB September 2015 Supersedes CG-SVU007A-GB_1114 We are committed to using environmentally conscious print practices that reduce waste.