Dell SC7020 Storage Controller Getting Started Guide

Similar documents
Dell SC5020 and SC5020F Storage Systems Getting Started Guide

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

Dell SC460 Expansion Enclosure Getting Started Guide

Dell MD1280 Storage Enclosure Getting Started Guide

SCv360 Expansion Enclosure

Dell PowerEdge T620 Getting Started Guide

Dell PowerEdge R720 and R720xd Getting Started Guide

Dell PowerEdge T420 Getting Started Guide

Dell SC7020 and SC7020F Storage Systems Owner s Manual

Dell PowerEdge T620 Getting Started Guide

Dell SCv3000 and SCv3020 Storage System Owner s Manual

Dell PowerVault MD3060e Storage Enclosure Owner's Manual

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

Dell Storage MD1400 and MD1420 Enclosures Getting Started Guide

Dell PowerVault MD3400/3420/3800i/3820i/3800f/ 3820f Storage Arrays Getting Started Guide

Installing the IPS 4345 and IPS 4360

Dell PowerVault MD3460/3860i/3860f Storage Arrays Getting Started Guide

Dell EMC Storage MD1280 Enclosure Owner's Manual

IndigoVision Enterprise NVR-AS 4000 G3 Windows Appliance. Quick Start Guide

IndigoVision Enterprise NVR-AS 4000 Linux Appliance. Quick Start Guide

Dell PowerEdge M905, M805, M605, and M600. Getting Started With Your System

Dell PowerVault MD3400/3420/3800i/3820i/ 3800f/3820f Storage Arrays Getting Started Guide

Dell Storage MD1400 Enclosures Hardware Owner's Manual

NOTE: Use the System Setup program to view microprocessor information. For more information, see "Using the System Setup Program."

Installing the Cisco MDS 9020 Fabric Switch

Dell SC5020 and SC5020F Storage System Owner s Manual

Dell Storage Center. Owner's Manual. SC180 Expansion Enclosure. Regulatory Model: E11J Regulatory Type: E11J001

DELL EMC SC SERIES EXPANSION ENCLOSURES

Dell Networking S4100-ON Series. Set-Up Guide

Summit Virtual Chassis Design and Installation Guide

2U STORAGE ENCLOSURE QUICK INSTALL GUIDE FS4100, FS4500, SC4100, AND FC4100

TECHNICAL SPECIFICATION. Brocade 6510 Switch Technical Specifications

SGI InfiniteStorage 120

System Storage DS3950 Quick Start Guide

E-Series Site Preparation Guide

S5048F-ON. Set-up Guide

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

StorNext M440 Site Planning Guide

Dell Latitude in-1

Power Enclosure Components

Dell Networking S4810 Open Networking (ON) Getting Started Guide

N3220 Installation and Setup Instructions

ftserver 3300 Service Bulletin

SCv3000 and SCv3020 Storage System. Owner s Manual

Junos WebApp Secure 5.0 Hardware Guide

N3240 Installation and Setup Instructions

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

SATADOM. for Dell PowerEdge R630, R730, and R730xd systems

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4450GTX-HT- PWR+

JanusRAID SA-6692J Hardware User Manual

Dell EMC ME4 Series JBOD 5U84 Enclosure

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

OmniCube CN-Series. Hardware Installation and Maintenance Guide CN-2000 CN-2200 CN-3000 CN-5000

Dell Vostro 320 Setup and Features Information Tech Sheet

G5 PDU Installation Guide

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

Dell EMC PowerEdge MX7000 Enclosure

N3150 Installation and Setup Instructions

Dell EMC PowerVault MD3460 Storage Arrays

Installation and Maintenance

TECHNICAL SPECIFICATION. Brocade 7800 Extension Switch Technical Specifications

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

Dell Storage Center. Owner's Manual. SC9000 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

TRC-190 User s Manual

Installing IDS Introducing IDS-4215 CHAPTER

Installing the Cisco SFS 3504 Server Switch

iconverter 2-Module Power Chassis

Installation Job Aid for Avaya Virtual Services Platform 8400

Dell Latitude E5410/E5510

Installation Job Aid for Ethernet Routing Switch 3600 Series

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Artico NAS Storage Appliance Site Planning Guide

Xcellis Workflow Extender (R520) Site Planning Guide

TRC-190 User s Manual

Dell PowerVault MD3800i and MD3820i Storage Arrays Owner's Manual

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

ETERNUS JX60. Technical Product Introduction. 0 Copyright Fujitsu, Release June 2014

VEP4600. Setup Guide

Dell Inspiron 300/400 Comprehensive Specifications

EMC SYMMETRIX VMAX 10K

DNS-2608 Enterprise JBOD Enclosure User Manual

Brocade ICX 6610 Switch

Dell Optiplex 390. Setup And Features Information. About Warnings. Mini-Tower Front And Back View

Dell PowerEdge FD332. Owner's Manual. Regulatory Model: E02B Regulatory Type: E02B003

Dell Latitude E6220. Setup And Features Information. About Warnings. Front And Back View

Inspiron Setup and Specifications

Dell Precision Workstation T7500/T7500n Setup and Features Information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Preface. Media Converter

Dell EMC PowerEdge XR2

Dell EMC Data Domain DD6300, DD6800, and DD9300 Systems

Dell Vostro 460. About Warnings. Setup and Features Information

S4112-ON Series. Setup Guide

EMC Symmetrix VMAX Cloud Edition

LVN5200A-R2, rev. 1, Hardware Installation Guide

Inspiron Setup and Specifications

hp uninterruptible power system r12000 xr models installation instructions

Dell EMC PowerEdge R540

Transcription:

Dell SC7020 Storage Controller Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001

Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies. 2016-08 Rev. R4GW6_A00

Setting Up the Storage System Consider the following best practices before setting up your SC7020 storage system. Dell recommends that you use a dedicated SAN network for data transmission when using a Fibre Channel or iscsi storage system. Always configure redundant data paths to provide alternate paths to and from the host server should one of the data paths become disabled. Before connecting any cables between the storage system and host server or expansion enclosure, physically label each port and connector. Always follow proper power-up and power-down procedures when cycling power across the network. Verify that critical network components are on separate power circuits. NOTE: This product is intended for restricted access locations, such as a dedicated equipment room or equipment closet. WARNING: If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer. Safety Warnings Electrical disconnection Indicates that all electrical supply connections to the storage system must be disconnected before proceeding. The following information only applies to Fibre Channel storage systems. Laser Radiation for Fibre Channel Storage Systems CAUTION: Class I laser radiation when open, avoid exposure to beam. 3

WARNING: Laser radiation, avoid direct exposure to beam. The unit is certified in the U.S. to conform to the requirements of DHHS 21 CFR, chapter 1 Subchapter J for Class I (1) laser products, and elsewhere is certified as a Class I laser product conforming to the requirements of IEC 60825-1:2007. Class I laser products are not considered to be hazardous. The laser system and unit are designed so there is never any human access to laser radiation above a Class I level during normal operation, user maintenance or prescribed service condition. Locating Your Service Tag Your storage system is identified by a unique Service Tag and Express Service Code. The Service Tag and Express Service Code are found on the front of the system by pulling out the information tag. Alternatively, the information may be on a sticker on the back of the storage system chassis. This information is used by Dell to route support calls to the appropriate personnel. NOTE: The Quick Resource Locator (QRL) code on the information tag is unique to your system. Scan the QRL to get immediate access to your system information using your smart phone or tablet. Other Information You May Need To install the storage system, you may need the following additional information. NOTE: See the safety and regulatory information that shipped with your Storage Center components. Warranty information is included as a separate document. The Dell Storage Center SC7020 Storage System Deployment Guide provides information about cabling storage controller hardware components and configuring a new storage controller using the Storage Manager Client. 4

Installation and Configuration Before you begin installation, make sure that the site where you plan to install the storage system has standard power from an independent source or a rack power distribution unit with a UPS. In addition, verify that there is space in the rack to install the storage system. Unpacking Storage Center Equipment Unpack the storage system and identify the items in your shipment. Figure 1. SC7020 Storage System Components Documentation Storage system Rack rails Front bezel Power and network cables (not shown) Install the Storage System in a Rack Install the storage system and other Storage Center system components in a rack. Mount the storage system and expansion enclosures in a manner that allows for expansion in the rack and prevents the rack from becoming top heavy. 5

The SC7020 storage system ships with a ReadyRails II kit. The rails come in two different styles: tool-less and tooled. Follow the detailed installation instructions located in the rail kit box for your particular style of rails. NOTE: The storage system and expansion enclosures each require 3U of rack space for installation. Dell recommends using two people to install the rail, one at the front of the rack and one at the back. Figure 2. Hole Locations in Rack 1. Pin hole 2. Rack mounting screw hole 3. Pin hole 4. Rack mounting screw hole Follow this procedure to install the storage system in a rack. 1. Position the left and right rail end pieces labeled FRONT facing inward and orient each end piece to seat in the holes on the front side of the vertical rack flanges. 2. Align each end piece with the top and bottom holes of the desired U space. 3. Engage the back end of the rail until it fully seats on the vertical rack flange and the latch clicks into place. 4. 6

Figure 3. Attach the rails to the rack 7

Figure 4. Slide the storage system onto the rails 8

Figure 5. Tighten the screws 4. Repeat these steps to position and seat the front end piece of the vertical flange. If the Storage Center system includes expansion enclosures, mount the expansion enclosures in the rack. See the instructions included with the expansion enclosure for detailed steps. Connect the Power Cables Connect power cables to the storage system. 1. Make sure that the power switches are in the OFF position before connecting the power cables. 2. Connect the power cables securely to both power supply/cooling fan modules in the storage system chassis. 9

Figure 6. Connect the Power Cables 3. Fasten the velcro strap to the power supply handle to prevent accidental pulling of the power cable. 4. Plug the other end of the power cables into a grounded electrical outlet or a separate power source such as an uninterrupted power supply (UPS) or a power distribution unit (PDU). NOM Information (Mexico Only) The following information is provided on the device described in this document in compliance with the requirements of the official Mexican standards (NOM): Importer: Model number: Supply voltage: Frequency: Current consumption: Dell Inc. de México, S.A. de C.V Paseo de la Reforma 2620-11 Piso Col. Lomas Atlas 11950 México, D.F. E03T 200 240 VAC 50/60 Hz 8.8 A 10

Technical Specifications The technical specifications of the SC7020 storage systems are displayed in the following tables. Drives SAS hard drives Up to 30 2.5-inch SAS hot-swappable hard drives (12GB SAS) Storage Controllers Storage controllers Up to two hot-swappable storage controllers with one mezzanine card and three IO slots. Storage Connectivity Configurations Storage Center supports up to 168 drives in one redundant-path SAS chain An SC7020 supports up to 12 SC400 expansion enclosures or 6 SC420 expansion enclosures Redundant Array of Independent Disks (RAID) Controller Management Two hot-swappable storage controllers RAID management using Storage Manager Client Back-Panel Ports Connectors (per Storage Controller) Fibre Channel, iscsi, or SAS connectors Ethernet connectors SAS connectors Connection to a Fiber Channel fabric, iscsi network MGMT: 100 Mbps, or 1 Gbps embedded Ethernet port used for Storage Center management 12GB SAS connectors for additional expansion enclosures NOTE: SAS connectors are SFF-8086/SFF-8088 compliant 11

Back-Panel Ports Connectors (per Storage Controller) Serial connector NOTE: Not for customer use LED Indicators Front panel One two-color LED indicator for system status. One single-color LED indicator for power status. ID button with a single-color LED indicating boot status and pressed states Hard drive carrier One single-color activity LED One single-color LED status indicator per drive Storage controller Power supply/ cooling fan Two single-color LEDs per Ethernet port indicating activity and link speed One dual-color LEDs per SAS connector indicating port activity and status One single-color LED indicating status One single-color LED indicating fault One single-color LED for identification Two LED status indicators for Power Supply Status, AC Fail status, DC Fail status, and Fan Fail status Power Supplies AC power supply (per power supply) Wattage 1485 W (maximum wattage: 1764 W) Voltage Heat dissipation Maximum inrush current 200 240 VAC (8.8A) 1764 W (6019 BTU/hr) Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 45 A per power supply for 40 ms or less Available Hard Drive Power (Per Slot) Supported hard drive power consumption (continuous) Up to 1.2 A at +5 V Up to 0.5 A at +12 V 12

Physical Height Width Depth Weight (maximum configuration) Weight without drives 13.34 cm (5.25 in.) 44.50 cm (17.5 in.) 78.27 cm (31 in.) 34.4 kg (76 lb.) 25 kg (55 lb.) Environmental For additional information about environmental measurements for specific storage system configurations, see dell.com/environmental_datasheets. Temperature Operating 10 C (50 F) to 35 C (95 F)with a maximum temperature gradation of 20 C/hour (36 F/hour) 52 C (126 F) maximum 2,000 to 3,048 m (6,562 to 10,000 ft) 47 C (117 F) maximum 3,048 to 4,000 m (10,000 to 13,123 ft) Storage 40 to 65 C ( 40 to 149 F) at a maximum altitude of 12,000 m (39,370 ft) Relative humidity Operating Storage 10% to 80% (noncondensing) with 29 C (84.2 F) maximum dew point 5% to 95% (noncondensing) with 33 C (91 F) maximum dew point Maximum vibration Operating Storage 0.21 G at 5 500 Hz for 15 min 1.04 G at 2 200 Hz for 15 min Maximum shock Operating 31 G +/- 5% with pulse duration of 2.6 msec +/- 10% (equivalent to 20 in/sec [51 cm/sec]) 13

Environmental Storage 71 G +/- 5% with pulse duration of 2 msec +/- 10% (equivalent to 35 in/sec [89 cm/sec]) Altitude Operating 3,048 meters (10,000 feet) <35 C (95 F) Maximum Rating Maximum temperature is reduced by 1 C/300 meter (1 F/547 feet) above 950 meters (3,117 feet) 40 C (104 F) Maximum Rating Maximum temperature is reduced by 1 C/175 meter (1 F/319 feet) above 950 meters (3,117 feet) >45 C (113 F) Maximum Rating Maximum temperature is reduced by 1 C/125 meter (1 F/228 feet) above 950 meters (3,117 feet) Storage 12,000 meters (39,370 feet) Airborne Contaminant Level Class G1 or lower as defined by ISA-S71.04-1985 14