Using Desktop PCs as RT Targets with the LabVIEW Real-Time Module

Similar documents
LabVIEW Real-Time Module Release and Upgrade Notes

Getting Started with the LabVIEW Real-Time Module

Getting Started with the LabWindows /CVI Real-Time Module

NI-Industrial Communications for EtherCAT

LabVIEW Datalogging and Supervisory Control Module

LabVIEW FPGA Module Release and Upgrade Notes

LabVIEW Real-Time Module for Mac OS X User Manual Addendum

LabVIEW Real-Time Module Release and Upgrade Notes

NI PXI Installing the NI PXI-8104 INSTALLATION GUIDE

LabVIEW for FTC Release Notes

Getting Started with the LabVIEW Robotics Module Version 2011

Getting Started with the NI 783x R

LabVIEW DSP Module Release and Upgrade Notes

GETTING STARTED GUIDE

NI-DAQ mx Base 1.x. Contents GETTING STARTED GUIDE

LabVIEW Real-Time Module Release Notes

PCI/PXI Gigabit Ethernet Adapters

NI PXI Contents GETTING STARTED GUIDE

NI WSN-9791 Ethernet Gateway

Programming for the LabVIEW Real-Time Module Using LabWindows/CVI

NI-DAQ mx for USB Devices

Foundation Fieldbus Hardware and NI-FBUS Software for Windows 2000/XP

Where to Start with NI ELVIS

NI USB-6211/6218 OEM

Where to Start with NI ELVIS

Contents. Getting Started. RELEASE NOTES TestStand ATML Toolkit Version 2017

IMAQ Vision Deployment Engine Note to Users

IMAQ Vision Deployment Engine Note to Users

This document includes instructions for installing and configuring your PXIe-8821 PXI Express controller module.

Foundation Fieldbus Hardware and NI-FBUS Software

VXI-MXI-Express Series

LabWindows /CVI Release Notes Version 2010

GETTING STARTED NI 9501 C Series Stepper Drive Modules and NI SoftMotion Module

Using the PXI-8150B in a PXI-1025 Chassis NOTE TO USERS

Measurement Studio Measurement Computing Edition

LabWindows /CVI Version 2017

NI sbrio Safety Guidelines GETTING STARTED GUIDE. Single-Board RIO OEM Devices. This document describes how to begin using the NI sbrio-9627.

TestStand. Contents RELEASE NOTES. Version 2017

Getting Results with CompactRIO and LabVIEW

LabWindows /CVI Version 2015

LabVIEW Datalogging and Supervisory Control Module

This document includes instructions for installing and configuring your NI PXIe-8880 embedded controller.

NI TestStand ATML Toolkit

LabVIEW VI Analyzer Toolkit

LabVIEW FPGA Module Release Notes

LabVIEW Release Notes

NI VeriStand Model Framework

NI TestStand ATML Toolkit Version 2013

This document includes instructions for installing and configuring your PXIe-8861 PXI Express controller module.

Getting Results with the NI PXI-6585R

LabVIEW Datalogging and Supervisory Control Module

Fujitsu LifeBook T Series

LabWindows /CVI Release Notes Version 8.0.1

Reinstalling the Operating System on the Dell PowerVault 745N

NI SMD-7620/7621 Stepper Drives and NI 73xx Motion Controllers

LABVIEW. Contents RELEASE NOTES. Version 6.1

S Series BIOS BIOS SETUP UTILITY. Entering the BIOS Setup Utility. Entering the Setup Utility After a Configuration Change or System Failure

T Series BIOS BIOS SETUP UTILITY

NI Contents. Hardware Overview INSTALLATION GUIDE. NI 8221 Features

Getting Started with the LabVIEW Real-Time Module

LabWindows /CVI Release Notes Version 9.0

Serial ATA PCI RAID Quick Installation Guide

LabVIEW Application Builder User Guide

LabVIEW PDA Module Release Notes

NEC Versa 500D/550D Windows 98 Upgrade Information

LabWindows /CVI Release Notes

Getting Started with R Series Intelligent DAQ

INSTALLATION INSTRUCTIONS Data Management Software Suite in the Evaluation Mode

Walkthrough: Creating a Measurement Studio Application with Web Forms Controls and Analysis

VXI-8340 SERIES INSTALLATION

Getting Started with R Series Multifunction RIO

Serial ATA PCI RAID Quick Installation Guide

The NI TB-2648/2649/2650/2651 terminal blocks configure your NI PXI/PXIe-2531 (NI 2531) in one of the following topologies. 1-wire 8 64 matrix

Measurement Studio Measurement Computing Edition

LabVIEW Release Notes

LabVIEW DSP Module. Contents. Introduction RELEASE NOTES. Version 1.0

S Series BIOS BIOS SETUP UTILITY

LabVIEW FPGA Module Version 2013

INSTALLATION INSTRUCTIONS Data Management Software Suite

NI 9512 C Series Modules and AKD Servo Drives

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

C Support for myrio 5.0 User Guide

Related Information Refer to the NI Switches Help for detailed information about features and programming options for your NI switch product.

MMX Enhanced. 586 GXM-AV Main Board. Trademarks and / or Registered trademarks are the properties of their respective owners.

Server Systems and Motherboards

Fujitsu LifeBook S Series

Windows Me Plug-and-Play

LabVIEW FPGA Module Release and Upgrade Notes

LabWindows /CVI Version 2013

IMAQ Vision 7 Development Module for LabVIEW Release Notes

Walkthrough: Creating a Measurement Studio Application with Web Forms Controls and Analysis

Fujitsu LifeBook E Series

System Overview and Terms

10 MHz to 6 GHz, x86 Processor, GPS-Disciplined OCXO, USRP Software Defined Radio Stand-Alone Device

LabVIEW Microprocessor SDK Release Notes Version 2009

HDD Setting OBJECTIVES RESOURCES DISCUSSION LAB PROCEDURE 4

NEC Versa 4200 Windows 98 Upgrade Information

BIOS Setup DESKPOWER 5000

Chapter. Configuring the Windows 2000 Environment MICROSOFT EXAM OBJECTIVES COVERED IN THIS CHAPTER

1. S Series BIOS BIOS SETUP UTILITY

Transcription:

Using Desktop PCs as RT Targets with the LabVIEW Real-Time Module Contents The LabVIEW Real-Time Module can execute VIs on RT targets running the real-time operating system of Ardence Phar Lap Embedded ToolSuite (ETS). This document contains important information about configuring a desktop PC as an RT target and information about installing software on the Refer to the Getting Started with the LabVIEW Real-Time Module document for exercises you can complete to familiarize yourself with the LabVIEW Real-Time Module. System Requirements... 2 Configuring a Desktop PC Using a Boot Disk... 2 Configuring a Desktop PC Using a Format Disk... 3 Configuring a Desktop PC Using a Utility USB Drive... 4 Boot from the USB Drive... 5 Format and Boot from the Hard Drive... 6 Installing Software... 7 Known Issues... 7 Resources... 8

System Requirements Table 1 describes the system requirements to configure a desktop PC as an RT target. Table 1. System Requirement for Desktop PCs Platform Desktop PC with x86-based processor Refer to the National Instruments Web site at ni.com/info and enter the info code etspc for information about the desktop PC models that National Instruments recommends. Media and System Requirements Desktop PC with a supported Ethernet chipset, the Ethernet device from the LabVIEW Real-Time Deployment License Bundle for Standard PCs, or a supported Ethernet card Refer to the NI Web site at ni.com/ info and enter the info code etspc for information about the Ethernet cards that National Instruments recommends. Formatted hard drive on the desktop PC with FAT32 file system. 3.5 inch floppy drive or USB port on the desktop PC. A boot disk, format disk, or utility USB drive Create a desktop PC boot disk, format disk, or utility USB drive using NI Measurement & Automation Explorer (MAX). Select Tools» RT Disk Utilities»Create Desktop PC Boot Disk in MAX to create the desktop PC boot disk. Select Tools»RT Disk Utilities»Create Desktop PC Format Hard Drive Disk in MAX to create the format disk. Select Tools»RT Disk Utilities»Create Desktop PC Utility USB Drive in MAX to create the utility USB drive. Configuring a Desktop PC Using a Boot Disk You can use a boot disk to launch the RT Module software that you install on the hard drive of a If there is no RT Module software installed on the hard drive, the desktop PC boots into safe mode, where you can install software. Complete the following steps to configure a desktop PC using a boot disk. 1. If the desktop PC does not include a motherboard with a supported Ethernet chipset, install a supported Ethernet card or the Ethernet Using Desktop PCs as RT Targets 2 ni.com

device included with the LabVIEW Real-Time Deployment License Bundle for Standard PCs in an available PCI slot of the PC. 2. Connect a monitor and keyboard to the desktop PC to display and respond to BIOS configuration utility prompts. Note National Instruments recommends that you remove from the desktop PC any PCI boards not supported by the LabVIEW Real-Time Module to reduce the possibility of resource conflicts. For example, remove sound cards, SCSI adapters, and modems from the 3. Turn on the desktop PC and access the BIOS configuration utility. Note BIOS configurations and configuration interfaces for desktop PCs vary among different manufacturers and system models. Consult the motherboard or system manual for information about accessing and configuring the BIOS settings of the 4. Set the boot configuration to use the floppy drive as the first boot device. 5. Disable legacy USB support. 6. Disable any unnecessary integrated peripherals that use an interrupt request line (IRQ). For example, disable unused serial ports or integrated sound on the 7. Save the configuration changes and exit the BIOS configuration utility. 8. Insert the desktop PC boot disk in the floppy drive and reboot the The desktop PC boots into the real-time operating system or into safe mode. Refer to the Installing Software section for information about installing the RT Module software on the hard drive if the PC boots into safe mode. Configuring a Desktop PC Using a Format Disk You can use a format disk to permanently install the RT Module software on the hard drive of the A format disk resets a previously formatted and partitioned hard drive and installs files to the desktop PC to allow you to start the PC without a boot disk. Caution A format disk overwrites the hard drive boot sector and master boot record, erasing all pointers to data on the drive. If you have a dual-boot configuration, the changes to the master boot record remove the ability to boot into the secondary operating system. National Instruments Corporation 3 Using Desktop PCs as RT Targets

Complete the following steps to configure a desktop PC using a format disk. 1. If the desktop PC does not include a motherboard with a supported Ethernet chipset, install a supported Ethernet card or the Ethernet device included with the LabVIEW Real-Time Deployment License Bundle for Standard PCs in an available PCI slot of the PC. 2. Connect a monitor and keyboard to the desktop PC to display and respond to BIOS configuration utility and format prompts. Note National Instruments recommends that you remove from the desktop PC any PCI boards not supported by the LabVIEW Real-Time Module to reduce the possibility of resource conflicts. For example, remove sound cards, SCSI adapters, and modems from the 3. Turn on the desktop PC and access the BIOS configuration utility. Note BIOS configurations and configuration interfaces for desktop PCs vary among different manufacturers and system models. Consult the motherboard or system manual for information about accessing and configuring the BIOS settings of the 4. Set the boot configuration to use the floppy drive as the first boot device. 5. Disable legacy USB support. 6. Disable any unnecessary integrated peripherals that use an interrupt request line (IRQ). For example, disable unused serial ports or integrated sound on the 7. Save the configuration changes and exit the BIOS configuration utility. 8. Insert the desktop PC format disk in the floppy drive and reboot the 9. Follow the directions that appear on the screen. 10. Remove the desktop PC format disk from the floppy drive and reboot the desktop PC to boot into the real-time operating system. The desktop PC boots into safe mode the first time the system boots from the hard drive. Refer to the Installing Software section for information about installing the RT Module software to the hard drive if the PC boots into safe mode. Configuring a Desktop PC Using a Utility USB Drive Use a utility USB drive to configure a desktop PC to boot from the USB drive or to format the hard drive of the desktop PC and then permanently install the RT Module software on the hard drive of the Using Desktop PCs as RT Targets 4 ni.com

Boot from the USB Drive Use a utility USB drive to configure a desktop PC to boot from the USB drive and launch the RT Module software on the hard drive of the desktop PC. If there is no RT Module software installed on the hard drive, the utility USB drive boots the desktop PC into safe mode, where you can install software. Complete the following steps to configure a desktop PC to boot using a utility USB drive. 1. If the desktop PC does not include a motherboard with a supported Ethernet chipset, install a supported Ethernet card or the Ethernet device included with the LabVIEW Real-Time Deployment License Bundle for Standard PCs in an available PCI slot of the PC. 2. Connect a monitor and keyboard to the desktop PC to display and respond to BIOS configuration utility prompts. Note National Instruments recommends that you remove from the desktop PC any PCI boards not supported by the LabVIEW Real-Time Module to reduce the possibility of resource conflicts. For example, remove sound cards, SCSI adapters, and modems from the 3. Turn on the desktop PC and access the BIOS configuration utility. Note BIOS configurations and configuration interfaces for desktop PCs vary among different manufacturers and system models. Consult the motherboard or system manual for information about accessing and configuring the BIOS settings of the 4. Set the boot configuration to use a USB drive as the first boot device. 5. Disable any unnecessary integrated peripherals that use an interrupt request line (IRQ). For example, disable unused serial ports or integrated sound on the 6. Save the configuration changes and exit the BIOS configuration utility. 7. Insert the utility USB drive into an empty USB port on the desktop PC and reboot the 8. Select the Boot using software installed on the hard-disk option from the utility USB drive menu. The desktop PC boots into the real-time operating system or into safe mode. Refer to the Installing Software section for information about installing the RT Module software on the hard drive if the PC boots into safe mode. National Instruments Corporation 5 Using Desktop PCs as RT Targets

Format and Boot from the Hard Drive Use a utility USB drive to permanently install the RT Module software on the hard drive of the A format option of the utility USB drive resets a previously formatted and partitioned hard drive and installs files to the desktop PC to allow you to start the PC without a boot disk. Caution The format utility of the utility USB drive overwrites the hard drive boot sector and master boot record, erasing all pointers to data on the drive. If you have a dual-boot configuration, the changes to the master boot record remove the ability to boot into the secondary operating system. Complete the following steps to format the hard drive and configure a desktop PC using a utility USB drive. 1. If the desktop PC does not include a motherboard with a supported Ethernet chipset, install a supported Ethernet card or the Ethernet device included with the LabVIEW Real-Time Deployment License Bundle for Standard PCs in an available PCI slot of the PC. 2. Connect a monitor and keyboard to the desktop PC to display and respond to BIOS configuration utility prompts. Note National Instruments recommends that you remove from the desktop PC any PCI boards not supported by the LabVIEW Real-Time Module to reduce the possibility of resource conflicts. For example, remove sound cards, SCSI adapters, and modems from the 3. Turn on the desktop PC and access the BIOS configuration utility. Note BIOS configurations and configuration interfaces for desktop PCs vary among different manufacturers and system models. Consult the motherboard or system manual for information about accessing and configuring the BIOS settings of the 4. Set the boot configuration to use a USB drive as the first boot device. 5. Disable any unnecessary integrated peripherals that use an interrupt request line (IRQ). For example, disable unused serial ports or integrated sound on the 6. Save the configuration changes and exit the BIOS configuration utility. 7. Insert the utility USB drive into an empty USB port on the desktop PC and reboot the 8. Select the Format hard disk option from the utility USB drive menu and follow the directions that appear on the screen. 9. Remove the utility USB drive and reboot the desktop PC to boot into the real-time operating system. The desktop PC boots into safe mode Using Desktop PCs as RT Targets 6 ni.com

Installing Software the first time the system boots from the hard drive. Refer to the Installing Software section for information about installing the RT Module software on the hard drive if the PC boots into safe mode. Complete the following steps to install software on the 1. Boot the desktop PC into the real-time operating system. The desktop PC loads with the basic real-time operating system and a null IP address of 0.0.0.0. Tip You can connect a monitor to the desktop PC to display startup messages. 2. Open MAX on another computer in the same subnet and expand the Remote Systems category. MAX lists the desktop PC as 0.0.0.0 in the Remote Systems category. 3. Click on the 0.0.0.0 entry to access the Network Settings tab. 4. Enter a name for the RT target in the Name text box. 5. Set the network configuration options of the RT target in the IP Settings section and click the Apply button. MAX prompts you to reboot the RT target to allow the changes to take effect. 6. Reboot the RT target. The RT target appears in the Remote Systems category with the assigned name. 7. Expand the RT target in the Remote Systems category and select the Software category. 8. Click the Add/Remove Software button in the toolbar to launch the LabVIEW Real-Time Software Wizard. 9. Install the LabVIEW Real-Time software and device drivers that you require on the RT target. Refer to the NI Web site at ni.com/info and enter the info code etspc for the latest information about supported software. Known Issues Refer to the readme_rt.html file on the LabVIEW Real-Time Module installation CD for information about known issues with using a desktop PC as an RT target with the LabVIEW Real-Time Module. National Instruments Corporation 7 Using Desktop PCs as RT Targets

You also can launch the readme_rt.html file from Windows after you install the Real-Time Module. Complete the following steps to access the readme_rt.html file from Windows. 1. Select Start»All Programs»National Instruments»LabVIEW 8.x» Readme, where x corresponds to your version of LabVIEW, to open the labview\readme directory. The labview\readme directory contains the HTML readme files for LabVIEW, the LabVIEW modules, and add-ons installed on the computer. 2. Double-click readme_rt.html to open the LabVIEW Real-Time Module Readme. Resources Refer to the NI Web site at ni.com/info and enter the info code etspc for the latest information about using desktop PCs as RT targets. Refer to the Getting Started with the LabVIEW Real-Time Module document for exercises you can complete to familiarize yourself with the LabVIEW Real-Time Module. Refer to the LabVIEW Help for more information about the LabVIEW Real-Time Module features. Access the LabVIEW Help from LabVIEW by selecting Help»Search the LabVIEW Help. National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents. 2004 2006 National Instruments Corporation. All rights reserved. 371857B-01 Aug06