Transponder card reader

Similar documents
Transponder card holder

Power supply module, bus connection module

Digital input modules

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Status display unit with P-bus connection

Room unit with PPS2 interface

Room unit with PPS2 interface

Web interface BACnet/IP

Temperature controller Ducted systems

Room unit with PPS2 interface

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Push Button Interface UP 220D31

252F 5WG FB_1 DELTA

BACnet/IP Web Interface

Room unit with PPS2 interface

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

PHOENIX CONTACT - 07/2006

Island bus expansion module

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

TU531, TU532 Terminal Unit

TRIO-DIODE/12-24DC/2X10/1X20

584 5WG AB_1 DELTA

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

Installation Instructions

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Room automation station

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

Temperature Controller

Extension module for Web functions generic

Product and functional description

TXM1.8RB. TX-I/O Blinds module

Product and functional description

Product and functional description

Immersion Temperature Sensors

Communication module to connect M-bus devices to POL6xx.xxx controllers.

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Extension module for graphic Web functions for one automation station

M-Bus Central Unit. Use

FL MC 2000E (SM40) LC

Room Temperature Controller

AO561 Analog Output Module

Master room unit for RRV controllers

USER MANUAL. Longo programmable controller LPC-2.CA1M Card Reader module. Version 2

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Application Description

Room Temperature Controllers

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

AI561 Analog Input Module

Compact Universal Controllers

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

QMX3.P30 QMX3.P70 QMX3.P02 QMX3.P34 QMX3.P74 QMX3.P37. Wall-mounted sensors and room operator units for KNX PL-Link, KNX S-mode and KNX LTE-Mode

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

Non-communicating room controllers

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

TF501, TF521 Terminal Bases

AO523 Analog Input Module

Product and functional description

Interface AP 146 5WG AB01 for Ethernet-UDP/IP. EIB Device. EIB Device. EIB Device

ERF910. RF Repeater. Synco living

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

USER MANUAL. Longo programmable controller LPC-2.IR2V Multisensor. Version 4

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

USER MANUAL. Longo programmable controller LPC-2.ID2 RFID Card holder. Version 8

PHOENIX CONTACT - 01/2007

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Heating Circuit Controller

QUINT-BUFFER/24DC/24DC/40

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

DI572 Digital Input Module

Operating instructions. Switching amplifier DN0210 DN / / 2015

Super universal modules

DELTA i-system wall switch single UP 221/2 5WG AB_2

Heating Circuit Controller

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Extension module for BACnet over Ethernet / IP and graphic Web functions

PXR11 PXR12. System controllers DESIGO PX

Extension module Integration of existing PTM I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

Push button UP 287, 4 - fold

Extension module for lighting control

USER MANUAL. Longo programmable controller LPC-2.CH1M Card Holder module. Version 3

USER MANUAL. Longo programmable controller LPC-2.CR1 Card Reader module. Version 5

Operating instructions. Speed monitor D / / 2014

CM597 Ethernet Communication Module

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Product and functional description

Room Temperature Controller

MINI MCR-SL-UI-REL(-SP)

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Resistance measuring module

Electrical Actuators

DELTA profil wall switch, single UP 241/2 5WG AB_2

Transcription:

6 337 HOTEL SOLUTION Transponder card reader HTR3.1/B Transponder card reader for hotel-room access control Touch-free recognition of access code on transponder card Transfer of access code to HRC3.. room controller Built-in optical display of messages from hotel room Illuminated symbols for signal indication Pushbutton for doorbell feature Application The HTR3.1/B transponder card reader is used in conjunction with the HRC3.. room controller. Guest and hotel-staff access codes are read touch-free by the HTR3.1/B transponder card reader, and transmitted to the HRC3.. room controller for access control. CM2N6337en 01.12.2008 Building Technologies

Functions The HTR3.1/B transponder card reader communicates with the HRC3.. room controller via a serial port, performing the following functions: Reads the access code on the transponder card from a distance of 0 6 cm After reading it, transfers the access code to the HRC3.. room controller Activates the functions programmed in the HRC3.. room controller based on the access code concerned (guest code, hotel staff code, invalid code). Transfers the pushbutton signal for the optional doorbell feature Displays signals from the HRC3.. room controller by means of illuminated symbols Types HTR3.1/B Transponder card reader Ordering When ordering, please specify the quantity, product name and type code: Example 30 Transponder card readers HTR3.1/B 30 Base frame for installation system AZ26.x (where x = 1... 4) Base frame The base frame must be ordered separately (see table below): Base frame AZ26.1 AZ26.2 AZ26.3 AZ26.4 Cover plate Bticino Living International Bticino Light Vimar Idea Siemens Delta Futura Ave Sistema 45 Gewiss Playbus Legrand Ergo Compatibility See assortment overview, N6301. 2/6

Design The HTR3.1/B transponder card reader consists of: Plastic housing Front cover with: 3 LED fields (red or green) 1 pushbutton for doorbell signal Rear, with Screw-terminal connections Pushbutton for bus address configuration Plug-in connection (not used) Front 1 2 3 4 1: Door status field 2: Service call field 3: Do not disturb field 4: Doorbell button s Rear + - 7 6 5 4 3 2 1 Screw terminal connections Pushbutton for bus address configuration Key to symbols Symbol/Code Color Description Symbol with green light Symbol with red light Flashing symbol Red light OFF for 3 s Door open Door closed Access denied Staff access denied: guest is in room Symbol with red light Flashing symbol Symbol with red light Room cleaning or Service call SOS, call for assistance Do not disturb 3/6

Engineering notes The HTR3.1/B transponder card reader is designed for flush wall mounting, and for fixing purposes is installed in a type AZ26.x base frame (where x = 1 4). Cover plates for this base frame are available from the installation ranges of various manufacturers (see "Ordering"). Up to four card readers can be connected to the same room bus. The address is set by means of pushbutton on the rear of the device (see below). The maximum permitted current associated with the supply voltage from the HRC3.. room controller must not be exceeded. Other information Refer to data sheets N6313, N6314 Mounting The HTR3.1/B transponder card reader must be mounted in the entrance lobby of the hotel room at the same height as the light switch. Ensure that there is sufficient spare cable in the mounting box to allow access to the pushbutton on the back, for the programming of addresses. The device is intended for fixed installation in a dry, enclosed space. For three modules, the mounting box must be installed at a depth of 47.5 mm Mount horizontally only, with the front plate vertical Do not install AC 230 V devices in the same mounting box Commissioning must be carried out by trained personnel only Do not open the unit Local safety and installation regulations must be observed Commissioning The address can be set by means of pushbutton on the rear of the device: 1. Connect the device to the room controller 2. To activate programming mode, use a small screwdriver to hold the pushbutton down for 3 seconds: All the LEDs will then light up to indicate programming mode. 3. Pressing the button briefly changes the address one step at a time, allowing you to cycle through the addresses shown below 4. Hold the pushbutton down for 3 seconds again to save the address. The new address is saved in the non-volatile area of the memory. All LEDs will then switch off. The addresses are indicated in code form by the following LED sequences: Bus address LED 1 LED 2 LED 3 Ready for programming ON ON ON 0x38 ON OFF OFF 0x39 OFF ON OFF 0x3A OFF OFF ON 0x3B ON ON OFF Note In the standard application with only one reader, Address 0x38 is intended for the HTR3.1/B transponder card reader. This address is factory-set in the HTH3.1/B transponder card reader. 4/6

Notes on operation (alarms) Light pattern Fast flashing of all symbols Slow flashing of all symbols (2 Hz) Description No bus signal, for the following reasons: Room controller switched off Room controller faulty Bus cable not connected or loose connection No bus signal for this device address Possible reasons: Wrong address set in the unit Wrong address set in the room controller Technical data Power supply Working voltage (SELV) DC 12 V +/ 10%, 1.2 W (from HRC3..) Bus interface Bus voltage SELV DC 12 V Type RS485 Transmission speed 4800 baud Screw terminals Max. conductor cross-section 1.5 mm 2 Display Luminous intensity of LEDs: 1.8 mcd Transponder card reader Read/write chip Atmel/Temic T5567 or T5557 Operating frequency 125 khz Transponder cards Aerial Rectangular, T5567 Operating frequency 125 khz Environmental conditions Operating temperature: 0...50ºC to EN 50090-2.2 Transport temperature: -20...55ºC Humidity Max. 90% non-condensing Air pressure during operation: Min. 700hPa (3000m above sea level) Air pressure during transportation: Min. 700hPa (10, 000m above sea level) Standards Electromagnetic Emitted interference in residential areas EN 61 000-6-3 compatibility Interference immunity in residential areas EN 61 000-6-1 EN 50090-2.2 Housing To EN 60 529 IP 20 protection standard Protection class To EN 61 140 III conformity Meets the requirements of: EMC Directive 89/336/EEC UL/CUL approval UL/CUL 916 Dimensions Suitable for flush mounting in rectangular 3 modules flush-mounting box or hollow wall box Orientation Horizontal only See also dimension diagrams 51 x 73.5 x 62 mm (H x W x D) Color Plastic components Gray Front Gray Weight Without packaging With packaging 84 g 146 g 5/6

Connection diagrams Connection terminals 7 6 5 4 3 2 1 1 DC +12V 2 DC 12V (GND) 3 Not used 4 Not used 5 BUS RS 485 TX 6 BUS RS 485 RX 7 GND Circuit diagram 7 6 5 4 3 2 1 S1 S1 Transponder card reader HTR3.1/B N1 HRC3.. room controller Dimensions 40 13 51.4 6336A01 1 2 3 4 X12 N1 Dimensions in mm s Transponder card reader with base frame AZ26.1; AZ26.2; AZ26.3; AZ26. 6/6 2005-2008 2008 Siemens Switzerland Ltd. Subject to change