L Series Humidity/-temperature sensors for use in heating, ventilation and air conditioning Technical data Humidity

Similar documents
I Series Humidity/-temperature sensors with analogue output signals Technical Data Humidity Temperature

I Series Humidity/-temperature sensors with analogue output signals Technical Data Humidity Temperature General data

D Series Sensors for Humidity and Temperature Measurement With calibrated dmodul

Description. Type Product No. Measuring Range PMU-Type max. ambient temperature

I Series Sensors for Humidity and Temperature For digital data transfer RS485 / MODBUS RTU or RS232 Technical Data Humidity

Duct humidity and temperature sensor for all HVAC duct applications. Designed for control and monitoring applications.

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

Datasheet DE DB_EN_DE44_LCD Rev. ST4-C 07/17. Digital 2-channel differential pressure switch/transmitter with colour-change LCD * *

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

Application. Types Available. Duct sensor for air quality, temperature and humidity (optional) Datasheet

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

EE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 36 v2.5 / Modification rights reserved EE210

EE80 Series. HVAC Room Transmitter and Switches for CO 2, Relative Humidity and Temperature EE80. Applications. Typical

TEMPERATURE - HUMIDITY ELEKTRONIK EE08

ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

Pneumatic Control/Feedback

Pneumatic Control/Feedback

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Operating instructions. Speed monitor D / / 2014

RТTH DUAL ROOM SWITCH

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

EE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

Immersion Temperature Sensors

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

Air Quality Sensor KNX AQS

Pneumatic Control/Feedback

BTL6-A_10-M -A1-S115. Data Sheet. english

H290 HUMIDITY TRANSMITTER INSTRUCTION MANUAL

Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX

RS-FS-N01 Wind speed transmitter user's Guide (485type)

Level probe with ceramic measuring cell

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

KNX T-UP. Temperature Sensor. Technical specifications and installation instructions

M8, M12, 3-, 4-, 5-, 8-, 12-pin, LED, shielded

RXTH DUAL ROOM SENSOR / SWITCH

Operating Manual LF1-LF4 i

Data Sheet MEM 22. Absolute Encoder Multiturn

Minimum < 0.2 ms, maximum 2 ms, typical 1 ms; On request: Delays or holding times for bubble events % relative humidity (not condensing)

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

Piccolo2-OEM Fiber-optic Version (Item nr. PICO2-OEM)

頤拓企業有限公司 TEL: TEKHNE TK-100 Dewpoint Transmitter. etorch Co., L. Users Manual. TEKHNE Corporation

PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10)

Transmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P LCD

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

LED LIGHT PANEL QUADRANT SMD

Flow Sensor SONOFLOW CO.55

Push-Pull and E-Stop Switches. Datasheet

Ordering Information. Smart Sensors (Inductive Displacement Type) ZX Series. Sensors

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

RXTP ROOM TEMPERATURE

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

MP 101A HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

Technical data. Your advantages

Suitable for detecting transparent films or transparent bottles

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

RHT-WM-485-LCD Transmitter and RHT-DM-485-LCD Transmitter

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

Operating instructions. Switching amplifier DN0210 DN / / 2015

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in

Incremental encoder GEL 2010

E2K-X4ME1 2M E2K-X4ME2 2M

Operating Instruction

TEMPERATURE AND HUMIDITY TRANSDUCER P18(D) TYPE

Technical data. Your advantages

Overview of types. Technical data

AO561 Analog Output Module

DI572 Digital Input Module

Humidity goes Digital

Operating Instructions Differential Pressure Transducer PS27

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL

Surface-Mounting Product Ranges

Zone Pressure Touch (ZPT) Sensor - Standard Range

NOVOTURN Multiturn-Sensor non-contacting. Series RSM2800 digital SSI, SPI

Level sensor Stainless steel version Model RLT-1000, for industrial applications

LED LINE SMD LIGHTBAR

accessories cable sockets SENSORFLEX single side ready-made

Vandal-proof latching action switch MSM LA

Linear Position Transducer HLT 1000-R2

LS 6600 Technical Datasheet

DI561 Digital Input Module

Product and Function Description

Temperature probes 468 Hans Turck GmbH & Co. KG Tel Fax Edition I/

Datasheet DE DB_EN_DE45_LCD Rev. ST4-G 11/17. Digital differential pressure switch / transmitter with colour-change LCD * *

TECHNICAL DATASHEET Absolute Encoder AC 58 - CANlayer2

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS

Instruction Manual. T3110 T3110L T3110Ex

Transcription:

Galltec Mess- und Regeltechnik GmbH MELA Sensortechnik GmbH Boschstr. 4 Raasdorfer Str. 18 71145 Bondorf. Germany 07987 Mohlsdorf-Teichwolframsdorf. Germany Tel. +49 (0)7457-9453-0 Tel. +49(0)3661-62704-0 Fax +49 (0)7457-3758 Fax +49(0)3661-62704-20 E-Mail: sensoren@galltec.de E-mail:mela@melasensor.de Humidity/-temperature sensors for use in heating, ventilation and air conditioning LK LP LI LW Four designs duct version (LK) wall mounting (LW) rod-shaped Ø 12mm (LP) room version (LI) Different physical outputs Output signals Special versions humidity and temp., 2 x active humidity active / temp. passive humidity only, active temperature only, active or passive 0...1 V 0...5 V 0...10 V 4...20 ma (only LK and LW) passive (temperature) sealing for increased requirements, e.g. condensation sealing against vibrations Technical data Humidity sensing element calibrated sensor chip calht output range 0...100 %rh accuracy 30...80 %rh at 10...40 C ±3 %rh < 30 %rh or > 80 %rh at 10...40 C ±5 %rh influence of temperature < 10 C or > 40 C typ. ±0.06 %rh/k Filter protective basket ZE07 (IP 00) filter with membrane ZE08 (IP30) PTFE sintered filter ZE05 (IP65) Rod-shaped sensor with 2 types of connection Temperature accuracy 6-pin plug-in connection and assembled cable permanently attached cable Temperature / active output sensing element output ranges accuracy at 10...40 C <10 C and >40 C calibrated sensor chip calht 0...+50 C -20...+80 C -30...+70 C 0...+100 C ±0.8 K s. diagramm page 1 of 8

Temperature / passive output sensing elements other sensing elements on demand Electrical data outputs 2 x 0...1 V 2 x 0...5 V 2 x 0...10 V 2 x 4...20 ma passive temperature outputs on demand Voltage supply LP, LK, LW, LI output: 0...1V 6...30 V DC 0...5V 24 V AC ± 10% or 9...30 V DC 0...10 V 12...30 V DC LK, LW, LI output: 0...10 V LK, LW output: 4...20 ma load resistance for output 0...1 V output 0...5 V output 0...10 V output 4...20 ma Pt100 Pt1000 e. g. NTC 24 V AC ± 10% or 13...30 V DC 12...30 V DC > 1 kohm > 10 kohm > 10 kohm see load diagram General data measuring medium min. air speed operating temperature type LP, LK, LW type LI storage temperature air, pressureless, non-aggressive, non-condensing 0.5 m/s -30...+80 C -20...+60 C -40...+85 C degree of protection of measuring head (series LK, LW, LP) with protective basket ZE07 with membrane filter ZE08 with PTFE sintered filter ZE05 degree of protection of housing type LP, LK, LW type LI material of housing type LP, LK, LW type LI IP00 IP30 IP65 IP65 IP30 PC (light grey / white) ABS (white) electromagnetic compatibility ref. EN 61326 Working range of humidity and temperature load (Ω) 1000 800 600 400 200 0 10 12 14 16 18 20 22 24 26 28 30 operating voltage (V) % r.h. 100% 80% 60% 40% 20% recommended working range 0% -40 C 0 C 40 C 80 C Operating the sensor in these areas can damage it! Accessories Designation Order reference Info sheet Description ZE36 ZE36 F5.2 adapter required for sensor tubes Ø 12mm for humidity standard ZE 31/1 and wall console 20.009 ZE 31/1 page 2 of 8 ZE 31/1-12 + ZE36 ZE 31/1-33 + ZE36 ZE 31/1-75 + ZE36 ZE 31/1-84 + ZE36 ZE 31/1-97 + ZE36 F5.2 humidity standard 12 %rh and 25 C 33 %rh and 25 C 75 %rh and 25 C 84 %rh and 25 C 97 %rh and 25 C Wall console 20.009 + ZE36 F5.1 wall console for wall-mounting of rod shaped- and duct sensors Flange 20.045 fixing flange for sensor tubes Ø 12mm with rubber sealing Cable LPx2.02 LPF2.02.67-xx.x LPK2.02.67-xx.x LPC2.02.67-xx.x cable, with 6-pin coupling for rod shaped sensor LP with plug-in connection unshielded, IP67, up to max. 10 m (xx.x = length in m, e.g. 01.5 = 1.5 m) for humidity sensor LPF2 for humidity/-temperature sensor LPK for humidity sensor with passive temperature output LPC

Product Key The 16 character alphanumeric order number for the desired type is composed of the order code listed below, 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Series Design Physical outputs Output signals Operating conditions / Special versions Measured variable and output range 1 Measured variable and output range 2 Operating voltage Measuring head / Filter / Diameter Design description Technical Data Options Order Code 1 Series L 2 Design Duct version K Wall mounting Rod shaped, plastic, Ø 12mm Room version 3 Physical outputs Humidity and temperature, 2 x active K Humidity active / temperature passive humidity only, active Temperature only, active or passive 4 Output signals 1x 0...1V or 2x 0...1V or 1x 0...1V/1x passive 1 1x 0...5V or 2x 0...5V or 1x 0...5V/1x passive 8 1x 0...10V or 2x 0...10V or 1x 0...10V/1x passive 2 1x 4...20 ma or 2x 4...20 ma or 1x 4...20 ma/1x passive 3 Temperature passive, only 5 5 6 Operation conditions / special versions Standard 00 Sealing against vibrations (optional for types LK, LW, LP) Sealing for increased requirements (e.g. condensation) (optional for types LK, LW, LP) 7 8 Measured variable and output range 1 None / no humidity measurement 00 Relative Humidity 0...100 % rh 9 10 Measured variable and output range 2 None / no temperature measurement 00 Temperature 0... 50 C 05 Temperature 0... 100 C 01 Temperature -20... 80 C 28 Temperature -30... 70 C 37 Temperature -40... 60 C 46 Temperature passive Pt100 cl. B Temperature passive Pt1000 Further output ranges on demand W P I C F T 0V 0S F1 C1 C5 page 3 of 8

Technical Data Options Order Code 11 Operation voltage Series LP, LK, LW, LI with 0...1V output: 6... 30 V DC 6 Series LP, LK, LW, LI with 0...5V output: 24 V AC ± 10% or 9... 30 V DC 9 Series LP, LK, LW, LI with 0...10V output: 12... 30 V DC Series LK, LW with 4...20 ma output: 12...30 V DC C Series LK, LW, LI with 0...10V output: 24 V AC ± 10% or 13... 30 V DC E Temperature sensors with passive output signal 0 12 13 Measuring head / Filter / Diameter ZE07: protective cage, plastic, open, Ø 12 mm 07 ZE08: protective cage, plastic, with membrane, Ø 12 mm 08 ZE05: PTFE sintered filter, Ø 12 mm 05 14 15 16 Description of design Rod shaped sensor, 6-pin plug-in connection Sensor tube length, incl. plug = 101 mm Rod shaped sensor, with permanently attached cable, 1.5 m, Sensor tube length = 95 mm special lengths for rod shaped sensors 6S 4 1K 4 xx 4 e.g. 2.0 m 2.5 m 3.0 m 3.5 m Duct sensor, sensor tube length 220 mm (standard) 02 4 2K 4 03 4 3K 4 00 G Wall mounting, sensor tube length 50 mm (standard) 00 1 Room sensor 00 0 Ordering Example Series: Design: Rod shaped Physical outputs: 2 active outputs Output signals: 2 x 0...10 V Operation conditions / special versions: Sealing against vibrations Measured variable and output range 1: 0...100% rh Measured variable and output range 2: -30...70 C Operating voltage: 12...30 V DC Measuring head / Filter / Diameter: PTFE sintered filter ZE05 / 12 mm Description of design with permanently attached cable, 1.5 m Sensor tube length = 95 mm L P K 2 0V F1 37 C 05 1K 4 page 4 of 8

Dimensional drawing rod-shaped sensor LP with permanently attached cable 33 95 12 Configuration of series LP with permanently attached cable Humidity 0...1/5/10 V conductor colour connection supply brown GND + UB humidity white 0...1/5/10 V Humidity and temperature active 0...1/5/10V conductor colour connection supply brown GND + UB humidity white 0...1/5/10 V temperature yellow 0...1/5/10 V Humidity 0...1/5/10 V temperature passive, 4-wire conductor colour supply brown GND connection + UB humidity white 0...1/5/10 V temperature blue T1 temperature yellow T1 temperature pink T2 temperature grey T2 Dimensional drawing rod-shaped sensor LP with plug-in connection and additional cable voltage output and / or temperature passive, 3-wire Dimensional drawing cable LPx2.02.67... 12 33 93,5 101 Pin assignment of accessory cable LPK2.02.67... (2x 0...1/5/10 V) Pin assignment of accessory cable LPF2.02.67... (0...1/5/10 V) white yellow brown white brown Pin assignment of accessory cable LPC2.02.67... (0...1/5/10 V and temperature passive, 3-wire) pink grey white yellow brown page 5 of 8

Dimensional drawing series LK Dimensional drawing series LW 12 83 220 1 15 18 1 15 40 40 26 57 41,5 83 83 12 57 50 Dimensional drawing series LI 1 11 81 25,7 47,5 10,5 81

Pin assignment of series LK, LW, LI Voltage output Voltage output Temperature 4-wire Connection between supply ground and measuring ground is not recommended for 24V AC. V-/GND terminals are internally connected Connection between supply ground and measuring ground is not recommended for 24V AC. V-/GND terminals are internally connected load resistance load resistance Pin assignment of series LK, LW, LI Temperature 4-wire Connection between supply ground and measuring ground is not recommended for 24V AC. Connection between supply ground and measuring ground is not recommended for 24V AC. ESD protection advice The sensors of the contain components, which can be damaged by the effects of electrical fields or by charge equalisation when touched. The following protective measures must be taken when the housing of the sensor is to be opened for connection: Before opening the housing of the sensor, ensure electrical potential equalisation between you and your environment. Pay particular attention to ensure that this potential equalisation is maintained while you are working with the opened housing. page 7 of 8

Mounting instructions Position Fixing flange Connection Install the sensor at a place where characteristic levels of humidity occur. The sensor tube resp. measuring head or measuring chamber should be exposed to the flow of air. Avoid installation next to heaters, doors or on outer walls. Avoid places exposed to the sun. The sensors for wall mounting (series LW) and the room versions (series LI) can be mounted on a patress or directly on the wall. It is important that the surface is even. When mounting the sensors on a patress, avoid external air getting onto the humidity measuring element of the sensor by sealing it appropriately. The sensor should be mounted in such a way that no water can get into it. To close the housing the screw is tightened until it stops. We recommend that you lay the connection lines in a loop so that any water that may be present can run off. For mounting the fixing flange (for duct mounting of series LK/LP), a hole pattern is printed on the packaging. To fix the sensor, simply open the opening tab of the flange by finger pressure or with the help of a pair of pliars. The sensor can be fixed in the flange at any position. The electrical connection must be carried out by qualified personnel only. Lines to and from the sensor must not be installed parallel to strong electromagnetical fields. In the case of a possible overvoltage please install surge protection devices. User instructions Dew formation Contaminated filters Cleaning of PTFE sintered filter ZE05 and protective basket ZE07 Cleaning of sensor chip Damaging influences Dew formation and splashes do not damage the sensor, although measurement readings are corrupted until all moisture on and around the sensing element has dried up completely. If the PTFE sintered filter ZE05 and the membrane filter ZE08 is contaminated with dust, grease and oils, this can have a negative impact on the dynamic behaviour of the sensor. If necessary, soiled filters and protective baskets can be screwed off and rinsed carefully. Bear in mind the sensors wil not measure accurately until filters are completely dry. Please do not touch the highly sensitive sensing element. Loose dust can be carefully cleaned off the humidity sensing element using distilled water or by blowing the dust carefully off. Please do not touch the highly sensitive humidity sensing element Depending on type and concentration, agents that are corrosive and contain solvents, can result in faulty measurements and can cause the sensor to break down. Substances deposited on the sensor (e. g. resin aerosols, lacuer aerosols, smoke deposits etc.) are damaging as they eventually form a water-repellent film. This information is based on current knowledge and is intended to provide details of our products and their possible applications. It does not, therefore, act as a guarantee of specific properties of the products described or of their suitability for a particular application. It is our experience that the equipment may be used across a broad spectrum of applications under the most varied conditions and loads. We cannot appraise every individual case. Purchasers and/or users are responsible for checking the equipment for suitability for any particular application. Any existing industrial rights of protection must be observed. The quality of our products is guaranteed under our General Conditions of Sale. Data sheet L -Serie_EN. Issue: September 2014. Subject to modifications. page 8 of 8