Service Manual. NEPTUNE Portable Patient Monitor

Similar documents
TRANQUILITY VS VERSATILITY IN VITAL SIGNS A M E R I C A S TRANQUILITY VS A M E R I C A S

Argentine Manufacturer of Hospital Equipment. Electrocardiograph Pulse Oximeters Vital Signs Monitors

PW 406. Features &Benefits: Multi parameters Patient monitor

INTRODUCTION The Monitor, interchangeable modules and storage batteries are described below. Refer to the table below for specifications.

etco 2 SpO 2 IBP medlab 2017/2018 OEM Modules for Patient Monitoring medizinische Diagnosegeräte GmbH

Cardiostart. Biphasic Defibrillator Monitor

STEP 2: VITALSBRIDGE TO PATIENT MONITOR CONNECTION GUIDE VITALSBRIDGE AND 100

*M C* Philips A1 and A3 Patient Monitors M3926A M3923A M3924A M3927A M3928A M3929A. Service Guide. Part Number M C

EC-12RT Resting ECG Machine. Technical Specification

Patient Simulator Series

Product Specifications

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

DPM 4 Patient Monitor. Service Manual

Propaq LT Monitors. Propaq LT Base Model. Propaq LT with Wireless Option/ Legendary quality and durability Heart rate, 3-or 5-lead ECG, SpO 2

ipm-9800 Patient Monitor Service Manual

MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

Patient Monitoring Systems. Patient Monitor Vital Sign Monitor Pulse Oximeter

StressLocator & Sleep as Android

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

SERVICE MANUAL. NPB-4000/4000C Patient Monitor

ACENDIS EMERGENCY ACENDIS APM-700 / 700 XL MODULAR PATIENT MONITOR

3700 SERIES USER MANUAL

CDD4 Duct Carbon Dioxide Transmitter

15 TFT-LCD Monitor Operation Manual

MD300 C5 Pediatric Oximeter

QUICK REFERENCE GUIDE

Duo is a U.S. trademark of Mindray DS USA, Inc. Navigator is a U.S. trademark of Mindray DS USA, Inc.

Installation and operation manual ReciFlow Gas

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Modified Sinewave Series. Power Inverter 1000/1500 MW 1210, MW1215. True Sinewave Power Inverter 1000/2000 SW 1210, SW 1220.

Propaq Vital Signs Monitors

PRODUCT SHEET. NON-INVASIVE SMALL ANIMAL TAIL BLOOD PRESSURE SYSTEMS NIBP250 Blood Pressure Amplifier NIBP200A Blood Pressure System

Pulsar EXtreme 2000/3000 VA

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

MXA2080. Stereo Power Amplifier. Owner s Manual

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Professional Health Solutions

NIR Moisture Analyzer KB-30

Tesla M3 MRI Patient Monitor

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

STANDARD OPERATING PROCEDURE TENSOVAL COMFORT

Vmed Technology. PC-Display Wireless Monitoring Software. For all Vmed Wireless Monitors. Installation, Setup and User Instructions Version 2.

DATA CONNECT ENTERPRISE

Autoranging True RMS Multimeter User Manual

7032 Digital-Analog Multimeter

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Arm Cuff. Model HEM-711AC

Model HM-535 Power Supply Installation and Service Instructions

MONITOR VITAL SIGNS W/SPO²,W/CAPNO TOC

User Guide True RMS Multimeter Extech EX205T

OPERATING INSTRUCTION

ETHOS Auto Ranging Digital Multimeter

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

TH2683 Insulation Resistance Meter. User s Mannual

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

DOT MATRIX PRINTER SP6000 SERIES

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ECG100S. General Information. Product Code

MODEL 805 USER MANUAL

User Manual. MAXISIM 2000 Patient Simulator

COT220-APK01. 22" Open-Frame Monitor with 4mm/6mm. Dust proof SAW Touchscreens. DongGuan CJTOUCH Electronic Co., Ltd. PUBLISHED DATE:

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

BANGLADESH UNIVERSITY OF ENGINEERING & TECHNOLOGY (BUET) DHAKA TECHNICAL SPECIFICATION FOR SUPPLY AND INSTALLATION OF LABORATORY EQUIPMENTS (PKG1).

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

CM/CS SERIES. Compact 100V amplifiers. Item ref: UK, UK, UK User Manual. CM/CS Series User Manual

Testing Instruments Manufactured by

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

IRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc.

QIT600F1 USER'S GUIDE

User's Guide. MiniTec TM Series Model MN25 MultiMeter

MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS

Addendum No. 2 Reference: ITB Procurement of Medical Equipment for the Intensive Care Unit at Alia Hospital Hebron

1. Safety Precautions (Read these precautions before use.)

Eltek TU GenII AQ110A comprehensive portable air quality monitor transmitter

L300 user manual. Programmable DC Electronic Load CONTENTS. Electronic Load Software CAUTION...2 SAFETY NOTES...2

ARA FTS Flow Calibrator. Operation Manual August 1, 2016

STANDARD OPERATING PROCEDURE TONOPORT V

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

Cardiac Monitoring Catalog USA

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Technical Specifications

RT4F-110V/25A RECTIFIER

Tx Link. Quick Setup Guide. English. Connection module

TABLE OF CONTENTS 1. SAFETY PRECAUTIONS GENERAL DESCRIPTION FEATURES AND FUNCTIONS 4. CONNECTIONS 6. APPLICATIONS...

Test equipment, adapters and facilities

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

RS Stock No Instruction Manual RS Input Data Logging Thermometer

Installation Manual. 65 Interactive LED/LCD. Model: HILF65101 (64.56 )

BSM- 9510J BSM- 9510K MU- 950RJ MU- 950RK RY- 002PA AY- 900PA AY- 910PA AA- 900PA WS- 920PA EK- 900P. Life Scope M BEDSIDE MONITOR BSM-9510

SECULIFE NIBP NON-INVASIVE BLOOD PRESSURE SIMULATOR

T L Audio INDIGO SERIES. User Manual PA-2001 VALVE PRE-AMPLIFIER. Tony Larking Professional Sales Limited, Letchworth, England.

CCPF-3500-XX OPERATION MANUAL. Lumina P/N

Rigel Medical Product Brochure Medical Test Equipment. rigelmedical.com

Chameleon Stand-alone

Transcription:

NEPTUNE Portable Patient Monitor

Contents Chapter 1. Introduction 1.1 About this manual 1.2 Warnings 1.3 General information of system 1.4 The symbols of system 1.5 Different models and modules Chapter 2. Theory of operation 2.1 Principles of monitoring 2.2 Modules Chapter 3. Technical specification of system 3.1 Block diagram 3.2 Connections diagram 3.3 System diagram 3.4 Circuit diagram & part lists Chapter 4.Installation 4.1 System installation 4.2 Fixed stand & trolley installation Chapter 5. Test procedures 5.1 Test equipment 5.2 Performance Test 5.3 Calibration Chapter 6. Care and cleaning 6.1 General care 6.2 General cleaning 6.3 Sterilization and disinfecting Chapter 7. Trouble shooting Chapter 8. Specifications 8.1 NEPTUNE Specifications 3

Neptune Monitors 4

Chapter 1. Introduction 1.1 About this manual Service manual only contains additional technical information about system This manual contains information about servicing and maintenance of NEPTUNE monitors. When you want to service these systems you should refer to this manual but if you want to know about systems setting and get more information about using those you should consult the operator s manual. This manual is intended to help diagnosing, servicing and trouble shooting the monitor to the board level. Board's schematics in this manual are only to describe how the system operates. It is not permitted to service the printed circuit boards of system. 1.2 Warnings 1. Bedside NEPTUNE patient monitors are intended for clinical monitoring application with operation only granted to appropriate medical staff. 2. There could be hazard of electrical shock by the monitor casing. 3. Do not touch patient, table near by or the equipment during defibrillation. 4. Alarm must be set up according to different situation of individual patient. Make sure that audio sounds can be activated when alarm occurs. 5. Every servicing or changing internal parts of system must be performed by qualified technicians of SIARE 6. These systems are not suitable for use in environments containing combined flammable anesthetic gases with air, oxygen or nitrogen oxide. Neptune Monitors 5

1.3 General information of system The NEPTUNE monitors are adaptable to adult and neonatal usage. Depend on model of system, modules are fixed in it and system can monitor vital signs as ECG, RR, SpO 2, NIBP, Dual-TEMP, Dual-IBP and Co 2. It integrates parameters measured by modules and displays them on screen, featuring compactness, lightweight and portability. Internal-battery facilitates transportation of patient. The internal battery can automatically be charged when connected to AC-power. In this case, turning on or off the system does not have any effect on the process of battery charging. The connectors of cables, sensors and cuff are at the left side of system. Other sockets like as network connector, DC-in and power plug-in are at the back of system. 1.3.1 General information On/off key, fixed function keys, Rotary switch, Alarm and Power indicators are placed on the right side of system's front panel. Display of NEPTUNE monitor is color TFT When you rotate Rotary switch, the selected parameters boarder will be bolded and if press it, the related menus will be displayed on the bottom of screen. In the parameter menus you can trace between parameters and select them by pressing rotary switch knob and apply proper setting. You can close setting menus by pressing Home/menu key or selecting Exit. This facility makes more user-friendly and easy to use. Neptune Monitors 6

Fixed function keys are: Alarm silence: pressing this key, you can mute the alarm temporarily for 120 seconds. Freeze: pressing this key, you can fix waveforms. Pressing the key again, waveforms restart. Rec/stop: pressing this key, you can run fixed recorder on system/central. Home/menu: pressing this key, you will be back to previous menu or screen. Start/Stop: pressing this key, you can start or stop blood pressure measurement manually. Power: pressing this key, you can turn on and off system. Notice: you should hold this key for 1 second. Neptune Monitors 7

1.3.4 General information of monitors In depend on system model; there could be any of following modules fixed in the system: ECG: ECG waveform in three leads, heart rate (HR) and pace detection and rejection. RESP: RESP waveform in two leads, respiration rate (RR) TEMP: Two channel (T 1, T 2 ) temperature for two sensors. SpO 2 : Pleth waveform and SpO 2 percentage and PR. NIBP: Pressure of systolic, diastolic and mean. IBP: Bp 1, Bp 2 waveforms and sys/ dia/ mean pressures for two channels. Co 2 : Capnogram and Fico2, Etco2, AWRR The patient parameters, waveforms, alarm message, bed number, date; system status and error message can be displayed from the screen. There are sockets at the left side of system. These sockets are fixed for connection of patient probes. Fig 1.3.3.1 Related to SpO 2 module type, there are two forms for side sockets. (fig. 1.3.3.1) Neptune Monitors 8

These parts are fixed at the back of system: 1. Power AC socket (AC-IN) 2. Power DC socket (DC-IN) 3. Network interface Socket 4. Earth jack 5. Battery fuse Notice: If you don t want to use system for more than two weeks, you should take out battery fuse to disconnect battery from circuit. 1.4 The symbols of system There are symbols on system that their meaning is in the following: This symbol means be careful refer to the manual. Indicates that the device is an IEC-601-1 type CF equipment. The units displaying this symbol an F-type isolated (floating) patient applied part providing a high degree of protection against shock and is suitable for use during defibrillation. Warning: If you want to use this system and electro shock at the same time you should use approved ECG cable of company so you shouldn t use another cables. Neptune Monitors 9

Chapter 2. Theory of operation 2.1 Principles of monitoring In depend on, what kinds of modules are fixed in monitors, they can measure following parameters: ECG Saturated Pulse Oximeter SpO 2 Respiration Temperature (2 channel) Non Invasive Blood Pressure Invasive Blood Pressure (2 channel) Co2 2.1.1 ECG The ECG or electrocardiograph is a graphic representation of heart s bioelectric current, which stimulates the heart muscle to contract. These currents are also conducted to the surface of the body, where they are measured via electrodes attached to the skin. The low-level signals from the electrodes are amplified and processed to provide the ECG signal. 2.1.2 Respiration Respiration is measured through the ECG electrodes by means of importance Anemography. As the chest change size and shape during inspiration and expiration, the impedance between two ECG electrodes placed across the patient s abdomen / chest change respiration rate is calculated from this change in resistance. 2.1.3 Temperature Temperatures are measured by meaning of the change in resistance of Thermistor located in temperature prob. 2.1.4 Saturated Pulse Oximeter (SpO 2 ) SpO 2 is determined using principles of spectrophotometry. The SpO 2 sensor consist two LEDs and a photo detector. LEDs emit two specific wavelengths of red and infrared light. Photo detector receives each light that is crossed through body tissue. Wavelengths are absorbed selectively by oxyhemoglobin and reduced hemoglobin. We can calculate %SpO 2 from waveforms of two wavelengths. The resulting measurement is the ratio of oxyhemoglobin to the total hemoglobin available for binding to oxygen. %SpO2= (HbO2/HbO2+Hb) x 100 Neptune Monitors 10

2.1.5 Non-Invasive Blood Pressure (NIBP) The monitor measures non-invasion blood pressure using oscillometric method to obtain the systolic, diastolic and mean pressure. Since the monitor controls the pressure within the cuff, it is considered an automatic invasive blood pressure device. The monitor measures the pressure within the cuff where the patient s pulse is detected as small pressure variations (oscillations). The mean arterial pressure is identified as the largest oscillation. The systolic and diastolic pressures are derived from the pulse amplitude data. 2.1.6 Invasive Blood Pressure (IBP) The monitor measures invasive blood pressure using pressure sensors. These sensors are located at outer end of tube. The other end of tube is placed through human vessel to the site the pressure to be monitored via the liquid in the tube. 2.1.7 Co2 Co2 module provides side stream method for CO2 measurement. Capnography is the noninvasive measurement and graphic display of airway CO2 concentration as a function of time. The resulting waveform is called a capnogram. The evaluation of the capnogram is useful in the assessment of adequacy of carbon dioxide exchange in the lungs, integrity of the patient's airway, cardiopulmonary function and ventilator function 2.2 Modules There are following modules in system: HOST CPU board Indicator and key board Display Power board Power control board and input/output ECG, RESP, TEMP board SpO 2 board NIBP board IBP board Co2 Neptune Monitors 11

2.2.1 HOST CPU Board This board consist of CPU, memory for main program, RAM for trend and system setup data, A/D for control of battery and D/A for making analog output sound, IC-controller of display and hardware of serial connection with internal modules and external network. Keyboard and display are connected to HOST CPU board. On the other hand, these boards communicate with modules for data transmitting. 2.2.2 Indicator and Keyboard This board is fixed in front panel and all of keys are located on that. HOST CPU controls condition of keys. Indicator lights for power and battery charge status are fixed in this board. In NEPTUNE model, backlight inverter of display is fixed in this board. 2.2.3 Display Display of NEPTUNE monitor is 12" or 15 color TFT 800 x 600 resolutions. 2.2.4 Power board The power board converts 110~240 V, 50/60 HZ AC Power to 14.6 V DC Power. Input and output of this board are isolated above 4000Vac There isn t control for turn on/off in this board. If this board connect to AC Power, It will be turn on otherwise, It will be turn off. 2.2.5 Power Control Board and Input/Output This board is identified SPC. SPC board will charge battery if power board is connected to AC power. If SPC is powered by power board, in addition to charging battery (whether the system is on or off), System will function by power board. If system turns on without AC Power connection, System will use battery for functioning. If DC-Input at the back of system connects to "SPC" board, it will be able to drive system. System turn on/off be performed by means of electronic switches, isolation of central network connection and amplifier of speaker are other parts of SPC board. Neptune Monitors 12

2.2.6 ECG, RESP, and TEMP Board This board is identified SE. This board is able to measure one channel ECG, one channel RESP and two channels TEMP. The signals are transferred by means of ECG cable and temperature probes then are amplified and after the conversion, these signals enter to micro controller. Filtering and processing of signals are performed by hardware and soft ware. These parameters/waveforms are provided: ECG waveform, HR, RESP waveform, RR, measuring of T 1 and T 2 and status. All of these data are transmitted to HOST CPU board. Some control commands are received from HOST CPU such as: ECG lead, gain, pace condition, kind of filter. Application part and enclosure are isolated from AC Power by Transformer and Optocoupler. 2.2.7 SpO 2 Board This board reports percentage of SpO 2 and pulse rate value to the HOST CPU. 2.2.8 NIBP Board NIBP board provides the systolic / diastolic and mean pressure values to the HOST CPU. This board inflates a cuff and measures the blood pressure by using non-invasive method 2.2.9 IBP Board IBP board provides the systolic / diastolic and mean pressure values to the HOST CPU. The pressure transition of tube causes the dome sensor to change its value, so this board amplifies this transition and send them to the HOST CPU 2.2.10 Co2 Board Co2 module provides capnogram and Etco2, Fico2 and AWRR to the HOST CPU. Neptune Monitors 13

Chapter 3. Technical specification of system 3.1 Block Diagram In the next pages, block diagram and relation between different parts are illustrated. The system is made from three parts: 1. Back case 2. Modules 3. Front panel 3.1.1 NEPTUNE Block Diagram 40 40 26 10 40 BATTERY ECG BOARD (SE) TFT DISPLAY POWER CONTROLLER BOARD (SPC) SPO2 BOARD (SX) IBP BOARD (SB) MOTHER BOARD (ST) POWER BOARD (SSP) I/O CONNECTOR NIBP BOARD CO2 BOARD CONNECTORS KEY BORARD & ROTARY SWITCH ( INVERTER Neptune Monitors 14

3.2 CONNECTION Diagram 3.2.1 BACK CASE CONNECTION Diagram D C B RECORDER 1 +5v -PPR +5V SIN SOUT -SOUTE -SINE -RDY RES2 SBR CON1 +5v -PPR +5V SIN SOUT -SOUTE -SINE -RDY RES2 JP2 -DCD RXD TXD -DTR -DSR -RTS -CTS HLP JP1 T O M O T H E R B O A R D C O M 2 DC-IN SOCKET 2 SPC NETWORK R J45 JP2 TXNO -TXNO RXNO -RXNO VCIN GI VCC VCCN G N D V V C C C C N 3 R -R V T -T X X C G X X N N I I N N N O O O O J8 G N D S P K R J6 SPEAKER J1 SPKR1 SPKR2 VCC RXM TXM -M -M -M -M VDD-E VDD-E VDD-E VDD-E VIN VIN VIN VIN -E -E -E -E T O M A IN R E IB O N C A B L E 4 D C B A GROUNDING CONNECTOR POWER SOCKET F AC1 F AC2 POWER B ATTER Y DC-IN + - DC-IN VB VB VIN J5 J4 J3 SOUND DEF-S EC G-O RXN TXN REQ-N AC-IN /FCHG ONOFF PI RX-BP BAT TX-BP JP2 Title JP1 VIN BACK CASE AC1 Size Number Revision F AC2 A4 Date: 6-Apr-2005 Sheet of File: C:\Documents and Settings\ghandchi\Desktop\BD1600.DDB Drawn By: 1 2 3 4 A Neptune Monitors 15

3.2.2 MODULE CONNECTION Diagram 1 2 3 4 INT23 2 NIBP MODULE F TX-BP RX-BP JP2 RX TX VDD VDD RX TX VDD VDD F TX-BP BAT RX-BP PI ONOFF /FCHG AC-IN REQ-N TXN RXN EC G-O DEF-S SOUND JP1 E D TO MAIN REIBON CABLE -E -E -E -E VIN VIN VIN VIN VDD-E VDD-E VDD-E VDD-E -M -M -M -M TXM RXM VCC EC G/R ESP /TEMP MODULE -M -M -M -M TXM RXM JP2 VCC JP1 JP6 EC G-T GA RA LA LF SHILD GR T1 T1_7 GR T2 T2_7 ECG/RESP SOCKET 1 2 3 4 5 6 TEMP SOC KET 1 2 3 TEMP SOC KET 1 2 3 E D SCAP BOARD LC 101 BOARD VCC RXM TXM -M -M -M -M JP1 VCC RXD JP2 TXD VCC TXD RXD J101 J102 1 2 WATER TRAP RECIVER 1 2 SPO2 MODULE IBP MODULE IBP1 SOCKET C -M -M -M -M TXM RXM VCC JP1 JP1 GBP WDT RST RX TX GBP -12 1 GBP WDT RST RX TX GBP -12 JP1 JP2 JP5 GRD1 IN+1 REF1 GAI IN-1 GRD2 IN+2 REF2 GAI IN-2 OUT+ OUT- PROBE GA CATHD ANODE 3 5 6 4 1 IBP2 SOCKET 3 5 6 4 1 SPO2 SOCKET 14 13 10 11 12 7 8 C B B A A Title MODULES Size Number Revision B Date: 6-Apr-20 05 Sh eet of File: C:\Documents Settings\ghandchi\Desktop\BD1600.DDB Drawn By: and 1 2 3 4 Neptune Monitors 16

3.2.3 NEPTUNE FRONT PANEL CONNECTION Diagram 1 2 3 4 ST BOARD MOTHER BOARD TFT DISPLAY D C B VCC RXM TXM -M -M -M -M VDD-E VDD-E VDD-E VDD-E VIN VIN VIN VIN -E -E -E -E SOUND DEF-S EC G-O RXN TXN REQ-N AC-IN /FCHG ONOFF PI RX-BP BAT TX-BP J3 J2 J8 TXD RXD CTS RTS DCD +5 VDD-EL -EL J6 ADJ -EL ON/OFF ALM1 LED ALARMSLNC FR EEZE REC/STOP ALM 2 LED POWER LED PI OUT STAR TSTOP J4 HOME/MENU FC HG OUT ON/OFF RXD TXD RTS CTS DCD + - INVERTER VIN ON/OFF DIM-CONT KEYBOARD & ROTARY 1 +3 VCC +3 VCC RED + RED - GREEN + GREEN - BLUE + BLUE - CLOCK_OUT+ CLOCK_OUT- VC C +5 VCC VC C ENAVEE CN1 ALM1 LED ALARMSLNC FREEZE REC/STOP ALM 2 LED POWER LED PI OUT STARTSTOP HOME/MENU FCHG OUT ON/OFF CCFL HV1 CN2 CCFL RTN +3 VCC +3 VCC RED + RED - GREEN + GREEN - BLUE + BLUE - CLOCK_OUT+ CLOCK_OUT- VCC +5 VCC VCC ENAVEE CCFL HV1 CCFL RTN D C B A ROT3 ROT3 J7 Title ROT2 ROT2 ROT1 ROT1 S1600 FRONT PANEL VCC VCC Size Number Revision A4 Date: 6-Apr-20 05 Sh eet of File: C:\Documents and Settings\ghandchi\Desktop\BD1600.DDB Drawn By: 1 2 3 4 A Neptune Monitors 17

3.3 System Diagram 1 2 3 4 SPEAKER D D 4000V ISOLATION AC-IN POWERBOARD SSP 15V-3A CONTROLLER BOARD (SPC) DC-POWER DATA CONTROL MOTHER BOARD (SM) LCD DISPLAY BATTERY 12V,3.3AH SERIAL C I/OCONNECTOR C EARTHJACK NETWORK DC- IN VGA 5 0 0 V I S O L A T I O N KEYBOARD (SK) CONVERTOR DCPOWER B C O N N E C T O R S ECG/RESP TEMP1 TEMP2 SPO2 ECG BOARD (SE) SPO2 BOARD (SX) 4 0 0 0 V I S O L A T I O N 4 0 0 0 V I S O L A T I O N DCPOWER DCPOWER B NIBP NIPB BOARD A 1 2 3 4 Title Size A4 Number Revision Date: 24-Jul-2004 Sheet of File: D:\n.ddb Drawn By: A Neptune Monitors 18

3.4 Circuit diagram & part lists Last revision of circuit diagrams & part lists are available on master document in SIARE For more information please contact following e-mail: mail@siare.it Neptune Monitors 19

Chapter 4.Installation 4.1 System installation 1. Make sure the package is not damaged 2. Take out the accessory package and make sure that the accessory (depending on system model) are complete 3. Install the proper stand according to 5.2.a &5.2.b 4. Install the system on stand according to 5.2.c 5. place the battery fuse in fuse holder on the back left corner of system 6. Place the cable holder and plug AC-cable to system. Check safety grounding system. 7. Plug the system to AC-line and turn on system 8. Unplug system. It must continue working (internal battery operation). Note: It is necessary to charge the battery completely before using, charge the battery for at least 8 hours. Note: Take out battery fuse if stored for more than 2 weeks 9. Test the system according to test III procedure and fill out test reports 10. Fill out the warranty card 4.2 Fixed stand & trolley installation 4.2.a fixed stand installation Warning: Use only fixed stands approved by SIARE Unpack the stand; install stand about 135 Cm heights, Select the proper place for stand and system, assign the screws place. Warning: Take care about undersurface cables, pipes and etc. Make holes on the wall with proper drill (drill No 7 is recommended) tight the fixed stand to wall by fastening all screws. Neptune Monitors 20

4.2.b Trolley installation Warning: Use only trolley approved by SIARE Open the trolley package and tight the separated parts ( basket, star wheels, handle.) together. 4.2.c System installation on fixed stand or trolley System must be tight to trolley or fixed stand by 6 screws. Recommended screws height is 10 mm and diameter is 4mm. 4 of these screws are placed at back of the system and 2 of them under the system. Warning: Use only screws with appropriate height Warning: Turn off system and unplug it before any installing operation. Neptune Monitors 21

Chapter 5. Test procedures 5.1 Test equipment 1. ECG Simulator 2. RESP Simulator 3. IBP Simulator 4. SpO 2 Simulator 5. NIBP Simulator 6. Leakage Tester 7. Watertrap with sample line 8. Co2 absorber 5.2 Performance Test 5.2.1 Power-on Test 1. Connect AC-Power cable to AC-Input socket of system and press power key until system turns on. Notice: press power key about 1 second. After that, suitable wave forms and parameters will be displayed in monitor. In this case, green power LED should be light. 2. Indicator light of charging battery should be green or orange. When internal battery is being charged, indicator is orange. While the battery is fully charged, indicator will be green. 3. Disconnect the system from AC power and turn it on. In this case, the battery symbol is displayed on screen to indicate the status of battery charge. 4. Use all keys and enter to different menus to make sure all keys are operating correctly. 5.2.2 ECG functions 1. Connect ECG patient cable to its connector on the left side of system. 2. Connect ECG simulator to ECG cable. 3. Set monitor in lead II and gain x1 and Set simulator to 60 Bpm. 4. Notice that ECG signal is displayed correctly and HR displayed by monitor is 60 ± 2 Bpm 5. Disconnect the RA lead from the simulator. The CHECK LEAD RA message should flash on display. 6. Reconnect the RA lead and disconnect the LF lead from the simulator. The CHECK LEAD LF message should flash on display. 7. Reconnect the LF lead and disconnect the LA lead. The CHECK LEADS message should flash on display. Neptune Monitors 22

5.2.3 RESP function Set the RESP simulator to 15 Brpm. Notice the monitor displays a normal RESP signal and calculates RR to 15 ± 2 BRPM. 5.2.4 SpO 2 functions 1. Connect a SpO 2 finger sensor to the monitor from the inner side of finger clamp, the red LED flashing should be seen and SpO 2 PROBE OFF message should be displayed on screen. 2. Attach sensor to finger for few seconds addition to PLETH signal, SpO 2 measurement value and pulse will be displayed. If you want to have HR from pulse waveform you should disconnect ECG cable from system. 3. Connect the finger clamp to the simulator, and set the Spo2 simulator to 98% and pulse rate to 60 Bpm. In this case, monitor displays PLETH signal, SPO 2 and pulse carefully. 5.2.5 NIBP functions 1. Connect one end of air hose to the monitor and the other end to a three way adaptor supplied with the NIBP simulator, connect adult patient cuff and air hose of simulator to the other way. Wrap the cuff around simulator block in a suitable condition. 2. Set the NIBP simulator to 120/80 mmhg and start monitor. 3. The measurement should be done and the NIBP read of the monitor should be the value of simulator setting monitor (120/80 mmhg with tolerance of ±5 mmhg for both systolic and diastolic) 4. Disconnect cuff from the air hose after that start monitor for measuring of pressure. The monitor should start inflating automatically after 10 seconds the inflation are stopped and the error massage be displayed in monitor. 5. Block the air outlet with finger and start monitor to inflat. The inflation should be immediately stopped and the error message be displayed. Neptune Monitors 23

5.2.6 IBP functions 1. Connect the IBP simulator to the monitor. Set pressure of simulator on zero and do zero set in system. 2. Set the IBP simulator on 120/80 mmhg. System displays pressure with tolerance ± 1 mmhg. 3. Do above functions for both BP 1 & BP 2. 5.2.7 Co2 functions 1. Make sure that watertrap is not connected to system. From Resp menus select capno. "CO2 NO WATERTRAP" error will be displayed. After 30 second,"co2 MODULE STANDBY" will be replaced by previous massage. 2. Connect co2 absorber to the watertrap and go to zero menu." low run time "error will be displayed. Wait for 5 minutes and try again. "ZERO OK" will be displayed. 3. Connect sample line to filter and breath through it. Capnogram and other parameters will be displayed. 4. Occlude the sample line or exhaust and wait for "CO2 INLET OCCLUDE" or "CO2 EXHAUST OCCLUDE" error massages 5.2.7 Alarm functions 1. Connect ECG cable to the monitor. Connect their leads to off simulator (HR= 0). After about 10 seconds, Systolic message should be displayed and alarm should be activated. 2. Press silence key, the alarm sound should be silenced and SILENCED" message should be displayed on monitor. 3. After 2 minutes, the alarm should be activated again. 5.2.8 Leakage test 1. Connect the patient monitor power cable, ground cable, and ECG cable to the SAFETEY ANALYSER. 2. Measure the chassis leakage current to ground with normal polarity. The leakage current should be less than 500 ua. 3. Measure the ECG lead leakage current to ground with normal and reverse polarity. These leakage currents should be less than 10 ua. 4. Repeat previous test in single fault condition. The leakage current should be less than 50 ua. 5. Measure the leakage current between all leads with normal and reveres polarity. The leakage currents should be less than 10 ua. Neptune Monitors 24

6. Measure the isolation leakage current in normal and single fault condition. The leakage current should be less than 50 ua. 4.3 calibration System calibration should be performed every two years or as frequent as dictated by hospital policy. When you need calibration services, contact after sale service of SIARE 4.3.a Capno module calibration It is recommended to calibrate your NEPTUNE systems with Capnograph feature every 6 month To calibrate the module go through OPERATION MANUAL instruction Neptune Monitors 25

Chapter 6. Care and Cleaning 6.1 General Care Qualified staff should perform using the system. Before using this device, do the following check: - Check if there is any damage of enclosure such as: ruin, break or crushed. - Check cables, probes and accessories of device. - Control function of device to make sure that device operates correctly. If you find any damage on the device, stop using it and contact the qualified technicians of hospital or after sale service of SIARE. Qualified technicians of SIARE should perform all checks that need to open the monitor. 6.2 General cleaning Warning: Before cleaning the monitor and accessories, turn off the monitor and disconnect it from power line. Non-caustic detergents such as soap and water can do regular cleaning of enclosure, display, cables and accessory probes. Alcohol, isopropanol and hospital grad ethanol are useable for cleaning. Notice: The cleaning agents don t enter in to the chassis of the device and make sure that cleaning agent doesn't leave at any part of device. Warning: avoid using of the ammoniac based and Acetone-based cleaners. 6.3 Sterilization and disinfecting It's better that sterilization and disinfecting be performed when necessary. Before sterilization and disinfecting, clean monitor. Recommended sterilization materials are Ethylate and Acetaldehyde. Notice: No part of the device can be subjected to immersion in liquid. Notice: Do not pour liquid on to the device during sterilization. Neptune Monitors 26

Chapter 7. Trouble shooting Repairing internal parts of the monitor must be only done by trained and authorized personnel of After Sale Service; otherwise SIARE will not take any responsibility for any possible hazard to the patient and the monitor. Troubleshooting guide is intended to help users to solve minor problems caused by incorrect use of the monitor or failure of accessories. When you face any problem, please be sure that you have followed all procedure mentioned in Correct Action column before you contact with After Sale Service. Fault Symptoms Possible Cause Correct Action Not to be turned on - Check POWER AC cable - Charge the battery for more - Battery is discharged Unable to work than 10 hours - Fuse of Battery is faulty with Battery - Check fuse existence - Others NO ECG waveform Noisy ECG waveform Spike on ECG waveform Unstable HR No RESP signal Unstable waveform Unstable RR - ECG cable is not connected correctly - Bad placement of leads and electrodes - Others - Loose connection of electrodes - Earth connection failure - Wrong ECG filter - Others - If "PACE ON" for patient without Pace marker,ecg noise will be received as PACE. - Others - ECG signal is noisy or isn t suitable - Others - Electrodes are not connected correctly - Patient movement during measurement - Others - Connect ECG cable correctly - Check leads and electrodes. - Don t use old and faulty electrodes - Check electrodes and leads - Check earth - Set filter mode correctly - Turn Paced detect OFF in ECG menu - Check leads and electrodes. - Change lead to display the best ECG signal - Check leads and electrodes. - change RESP lead - Calm patient Neptune Monitors 27

Fault Symptoms Possible Cause Correct Action - Location of sensor isn t suitable - Put the sensor in suitable place Strange T1,T2 - Faulty sensor - Change sensor - Others No SPO 2 waveform Noisy waveform Strange SPO 2 value NIBP can not inflate NIBP measurement is not successful strange NIBP value. Strange IBP value Noisy IBP signal fault #01 Fault#02 fault#03 fault#51 Fault#57 fault#60 fault#65 fault#66 - SPO 2 probe is in an unsuitable place. - Faulty sensor - Others - Patient movement during measurement - Probe is in an unsuitable place. - Others - Incorrect air hose connection. - Air hose occluded or tangled. - Air hose or cuff leakage - Others - No cuff or Air hose is connected - Wrong cuff placement - Patient movement during measurement - Others - No zeroing before use - noisy source exists near by system or accessories - faulty sensor - Others - Communication Error - Host command with invalid data - Unprotected operation violation - Customer code mismatch - CO2 Sensor not found - CO2sensor EEPROM error in revision # - CO2 sensor EEPROM error in read or write operation - CO2 sensor EEPROM error in CCTTT/CRC code - Change the place of probe on patient - Change probe - Calm patient - Change the place of probe - Check connection - Check Air hose - Change faulty accessory - Check cuff and air hose - Change cuff placement - Calm patient - zeroing - keep system and cable away from noise source - change sensor Neptune Monitors 28

fault#70 fault#71 fault#40 fault#44 fault#46 fault#47 fault#4b fault#4c fault#4d fault#4e fault#4f fault#80 fault#84 fault#85 CO2 No water trap CO2 INLET OCCLUDE CO2 EXHUST OCCLUDE CO2 Unexpected reverse flow CO2 Unexpected forward flow RESP APNEA CO2 NO MODULE - CO2 sensor temperature too high - CO2 sensor temperature too low - Watchdog error - System EEPROM error in CCITT/CRC Code - System FLASH ROM Error in CCITT/CRC Code - System communication Error - System external RAM Error - System internal RAM Error - System FLASH ROM Error in Checksum - Stack overflow error - System main program exited - Pump failure - Barometric pressure too high - Barometric pressure too low - Watertrap is not connected to the system (16) - Obstructed watertrap cannula (17). - Exhaust occlusion or pneumatic leak (18) - Unexpected reverse flow or vacuum offset too large.(15,81) - Unexpected Forward flow (82) - No respiration condition overruns adjusted time - No module or communication Error - Connect watertrap - Change watertrap or sample line - Delete the negative pressure source, or vacuum - Delete the positive pressure source, or flow source - There is no CO2 module or another problem appeared. Neptune Monitors 29

Chapter 8. Specifications 8.1 NEPTUNE Specifications DISPLAY Displaying Waveforms Sweep Speed Numeric Parameters Operation Method TFT COLOR 800 600, (NEPTUNE) ECG, ECG Cascade SPO2, RESP, IBP1 IBP2, CO2 (all Freezable) 12.5,25,50 mm/sec HR, SPO2, NIBP (SYS, DIA, MAP), DT RR, T1, T2, IBP1 & IBP2 (SYS, DIA, MEAN) CO2, FiCO2, EtCO2, AWRR Membrane and rotary knob ECG Leads 3 Wires, I, II, III Dynamic Range ± 5 mv Leakage Current < 10 µa Lead Off Current < 90 na Gain 4, 2, 1, 1/2, 1/4, Auto Calibration 1mV, 0.5 sec Filters MONITOR (0.5-28 Hz) NORMAL (0.5-40 Hz) EXTENDED (0.05-100 Hz ) CMRR > 98 db Internal Noise < 30 µv RTI Input Impedance > 10 Mohm QRS Detection Duration: 40 to 120 msec Amplitude: 0.5 to 5 mv for Adult 0.2 to 5 mv for Neonate Heart Rate Range 25-250 bpm Tall T-Wave Reject up to 1.2 mv Amp. Pacer Detection/Rejection Duration: 0.1-2 msec Amp: ±2 to ± 700 mv (Without over/undershoot) Reject From Heart Rate Counter Re-insert into ECG to display on screen Protection Defibrillator and Electrosurgery Standards IEC 60601-1, ANSI/AAMI EC-13 Neptune Monitors 30

NIBP Measurement method Oscillometric Measurement mode Manual/Automatic Measurement time 18-26 sec (excluding cuff pressurization time) Measurement Range Adult: SYS 25 ~ 250 mmhg DIA 10 ~ 220 mmhg MAP 15 ~ 250 mmhg Neonate: SYS 25 ~ 135 mmhg DIA 10 ~ 110 mmhg MAP 15 ~ 125 mmhg Pressure Transducer accuracy ±3 mmhg full range Initial Inflation Target Adult 150 mmhg, Neonate 70 mmhg Overall System Efficacy Meet ANSI/AAMI SP-10/1992 Memory 100 Records SPO2 (Pulse Oximetry) Method 2 Wave Length Pulse Wave Type Range 50 to 100 % Accuracy 2% (SPO2 70 ~ 100%) 3% (SPO2 50 ~ 70%) Pulse Rate Range 25-250 bpm TEMPERATURE Probe Type YSI-700/400 Compatible Range 0-50 C Accuracy ± 0.2 C RESPIRATION Method Base Resistance Dynamic Range Breath Rate Range Impedance 250-1250 Ohm 0.2-2 Ohm 6-150 Brpm IBP Channel 2 Press Sensor Sensitivity 5 µv / V / mmhg Press Sensor Impedance 300 ~ 2500 Ohm Resolution 1 mmhg Error 2 % or 2mmHg which ever is greater Neptune Monitors 31

CO2 Method Measuring mode Measuring rang Co2 AWRR Resolution Co2 AWRR Accuracy Co2 AWRR Infra-red absorption Side stream 0~99mmHg 0~250BPM 1mmHg 1BPM ±4mmHg 0~40mmHg ±10% of reading 41~76mmHg ±12% of reading 77~99mmHg ±2BPM Typical accuracy is based on the following: Ambient temperature 22ºC Standard gas mixture of CO2 in balance air Barometric pressure at 760 mmhg (sea level) CO2 sample line 7 foot, ID 0.55'' (1.4mm) Sampling flow rate 175ml/min Respiratory rate<30bpm, stable to ±3BPM I: E ratio =1:2 CO2 accuracy is derated between 5ºC to 15ºC and 45ºC to 55ºC Start up time Less than 10 seconds to acquire CO2 waveform data Less than 3 min to full operating specification Calibration Zero calibration and two user calibration Rise time 200 msec (10% to 90%) Delay time 1.12 sec Patient application Neonatal to adult Flow rate 100,150,200ml/min Flow rate accuracy -20/+15% of set value Pressure compensation Automatic at power on and watertrap replacement BTPS compensation yes N2O, O2, and Desflurane compensation yes ALARM Sources Alarm On/Off Alert Limits, Error messages, All other Parameter Limits Selectable for All Parameters Blinking on Display, Volume Selectable Audio Alarms Light indicator Neptune Monitors 32

TREND Sources Trend Time Resolution List INPUT/OUTPUT Network Connection GENERAL Safety Protection AC Power Internal Battery DC Power Plug Dimension Weight HR, SPO2, NIBP, RR, T1, T2, IBP1, IBP2 1, 2, 4, 8, 16, 24 Hours 20 sec NIBP (100 Records) Digital, Serial, RS422, Full Duplex 8 BED to One CENTRAL system IEC 60601-1, Class I, Type CF Against Electro surgery and Defibrillator 200-240 VAC, 50/60 Hz Sealed Lead Acid, Rechargeable, 12V, 3.3AH Usage: 45 min (Full Charge) 12-14 V, 3 A 26 (W) 21 (H) 19 (D) Approx: 7 Kg ENVIRONMENTAL Temperature Operating: 0 to 40 C Storage: - 20 to 60 C Humidity 0-90 % (Noncondensing) Altitude -200 to 3000 m Neptune Monitors 33

SIARE applies the UNI EN ISO 13485:2004 Quality System and the EEC 93/42 Medical Devices Directive. SIARE ENGINEERING INTERNATIONAL GROUP s.r.l. Via Pastore, 18 40056 Crespellano (Bologna) ITALY Tel : +39 051 969802 - Fax : +39 051 969366 Email : mail@siare.it - http://www.siare.it Neptune Monitors 34