CTR21, CTR22, CTR23, and CTR24 Wall Modules

Similar documents
T7460A,B,C,D,E,F WALL MODULES

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module

T7460A,B,C,D,E,F WALL MODULES

T7560A1036 Digital Wall Module

Separate mounting base for easy installation. Tamper resistant locking cover.

T7560A,B,C Digital Wall Module

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

BA/BS4S Temperature Sensor Installation & Operating Instructions

H7625A, H7635A Humidity/Temperature Sensors

Stryker Lon Configurable Controllers

Allure EC-Smart-Comfort Series

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

TR21-WS, TR23-WS, TR21-WK, TR23-WK, WRECVR

H7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors

C7110C1001A / C7110D1009A WALL MODULES

Allure EC-Smart-Comfort Series

ComfortPoint Programmable Lon, VAV/Unitary Controllers

TM-2100 Series Room Command Module

TM-2100 Series Room Command Module

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)

RS-WMB, RD-WMB Wallbus Room Sensors and Displays

RCM Room Command Module New Style

Stryker Lon Configurable Controllers

LTEC Heat Pump DDC Controller

LED55WPG Programmable LED Driver

Spyder Lon Programmable, VAV/Unitary Controllers

LLR-MOD Modbus Light Level and Occupancy Sensor

Zio Lite TOOL CONFIGURATION, NETWORK ACCESS, SYLK CAPACITY, AND OPERATION TR40/TR42

SLX Series. Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L)

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

Excel 10 W7751B,D,F VAV II Controllers

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

Product Catalog. Tracer Controls Tracer ZN517 Unitary Control BAS-PRC012-EN. August 2010

MOD-RI Room Interface Modules with Modbus

Sylk I/O Devices APPLICATION FEATURES PRODUCT DATA

TC-9102 Terminal Controller

Hardware Installation. Tracer MP581 Programmable Controller CNT-SVN01C-EN

TAC Xenta 301. Controller, Freely Programmable

Excel 10 W7754K,P,Q,R,S,T,V FAN COIL UNIT CONTROLLERS

Spyder Lon Programmable, VAV/Unitary Controllers

PHS Series. PowerHUBB Node - Satellite

Zio LCD Wall Modules TR70 AND TR70-H with Sylk bus

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Content. Product Description

TAC Xenta 121-FC Programmable Fan Coil Application

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Installation and Operation. Tracer MP501 Controller CNT-SVX08B-EN

S7999D SOLA Operator Interface Display

TER-MOD Active Room Temperature Sensors (Controllers) with Modbus

LTEC Unit Ventilator DDC Controller

I/O Modules Quick Selection Guide. Choose From The Most Complete Line Of Input/Output Modules Available

Moxa TCC-100 Series Hardware Installation Guide

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

Precision humidity/temperature control/sensing

MicroTech II Vertical Self-contained Systems Unit Controller

RHR-MOD Combined Room Temperature and Humidity Sensors (Controllers) with Modbus

PHM Series. PowerHUBB Node - Master/Control

TF243 Series Digital Thermostat Fan Coil Unit Control

S025W-056C W Programmable LED Drivers

TAC Xenta 121-HP Programmable Heat Pump Application

FX06 Field Controller

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

SPYDER UNITARY CONTROLLER: LONMARK

EA500. Installation Instructions Transponder

T775S Series 2000 Expansion Module

INSTALLATION INSTRUCTIONS

IQ-SBS LCU Series Installation Instructions

SmartVFD Frame 8 Wiring Diagrams and Dimensional Drawings

ETM-2050/ETM-2051 Service Manual

Installation Guide. Room Temperature Sensors. Mounting. Location and Cover Removal (All) STE-6011 Only. STE-6010/6013/6015 Only

JADE Economizer Module (MODEL W7220)

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

Overview. Integrated fail-safe mode in case of communication or power failure to comply with most regulation requirements

clarity 3 Programmable Controller

Q7055B Building Network Adapters BNA-1C/2CS/2DN

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

MODEL 2000T Initial Draft

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Basic Temperature and Limit Controllers

LON Module for Variable Speed Drive

MN-Sx, MN-SxHT, MN-S4-FCS, and MN-S4HT-FCS TAC I/A Series MicroNet Sensors General Instructions

FEATURES DESCRIPTION MODEL 110B. Power Supply

Environmental. Electrical Specifications at 25 O C. Programmable Maximum Value. Factory Default

LX Series Remote Input/Output (I/O) Controller

TC-9102 Series Surface Mount Temperature Controllers

LOCAL DISPLAY UNIT (LDU)

TC-8900 Controller Units with PM-8900 Power Modules

Room unit with PPS2 interface

Transcription:

CTR21, CTR22, CTR23, and CTR24 Wall Modules FEATURES SPECIFICATION DATA The CTR21, CTR22, CTR23, and CTR24 family of wall modules include: Models with setpoint adjustment. Models with occupied/unoccupied override (bypass) with LED. Models with 3-position (auto/0/1) or 5-position (auto/0/1/2/3 speed) fan switch. LONWORKS bus jack on all models except the CTR21 and CTR21-A models. Operating range 45 F to 99 F (7 C to 37 C). Models (CTR22 and CTR23) with user-selectable temperature setpoint dials in Fahrenheit, Celsius, and Relative (- to +). SPECIFICATIONS Models: See Table 1 on page 2. Construction: Two-piece construction, cover and internally wired subbase. Field wiring 16 to 22 AWG (1.31-0.33 sq. mm) connects to a terminal block in the subbase. GENERAL The CTR21, CTR22, CTR23, and CTR24 are a family of direct wired wall modules for use with: Honeywell Excel 800, 600, 100, and 80 (all fully programmable) controllers Excel 10 W7750, W7751 a, W7752, and W7753 controllers W7761 Controller Spyder Unitary Controllers: PUL, PVL ComfortPoint LON Controllers: CP-UL, CP-VL All models have a space temperature sensor. Some models have a temperature dial, setpoint adjustment, LONWORKS bus jack, override (bypass) with LED, and fan switch. The figure above is the CTR23 model. Mounting Options: All modules can be mounted on a standard two by four inch junction box or on a 60 mm diameter junction box. Dimensions (H/W/D): See Fig. 2 on page 3. Environmental Ratings: Operating Temperature: 45 F to 99 F (7 C to 37 C). Shipping Temperature: -40 F to 150 F (-40 C to 65.5 C). Relative Humidity: 5% to 95% non condensing Humidity Output Accuracy: ±5% from 20 80% RH Temperature Setpoint Ranges (CTR22 and CTR23 only): The setpoint range is determined by the temperature knob installed: 55 F to 85 F 13 C to 29 C a The CTR21, CTR22, CTR23, and CTR24 wall modules are not compatible with W7751A,C,E,G Controllers. 50040122-003

Accessories: 50007298-001 (pack of 12) medium, cover plate; 6-7/8 x 5 in. (175 x 127 mm). (Optional part, extra order needed) Approvals: CE; UL94 plastic enclosure; FCC Part 15, Class B Temperature Sensor CTR21, CTR22, CTR23, and CTR24 20K Ohm Nonlinearized Sensor: All models are furnished with a 20K Ohm non-linear NTC temperature sensor that follows a specific temperature resistance curve. See Fig. 1. Honeywell controllers used with the CTR21, CTR22, CTR23 and CTR24 models employ an algorithm that provides readings close to the actual temperature. Sensor accuracy across the range of 55 F to 85 F (13 C to 29 C) is better than ±0.36 F(±0.2 C). NOTE: The CTR21-A wall module model has two 20K Ohm non-linear NTC temperature sensors in parallel, which provide 10K NTC temperature sensing necessary for averaging. 80K 70K 60K 50K 40K 30K 20K 10K 20K OHM AT 77 o F (25 o C) 30 40 50 60 70 80 90 100 110 0 10 20 30 40 o C TEMPERATURE (DEGREES) M5874A Fig. 1. Temperature vs. resistance for nonlinear sensor. Wall Module Features Table 1 illustrates the CTR21, CTR22, CTR23, and CTR24 wall module features and lists the existing Honeywell models that they replace. Table 1. CTR21-CTR24 Wall Module Features. a Model Number Sensor Type Selectable Setpoint Adjustment: Honeywell Wall Module Model Replaces Honeywell Model Sensor Element Type Temp 55 F to 85 F, 13 C to 30 C, or Relative (- to +) Button with LED LON Jack Fan Switching CTR21 T7770A1006 20K ohms non-linear CTR21-A T7770A3002 10K ohms non-linear for averaging only CTR21-H n/a CTR21-J T7770A2004 CTR22 T7770B1004 T7770B1020 T7770B1046 n/a CTR23 T7770C1002 T7770C1028 T7770C1044 20K ohms non-linear CTR23-H n/a CT24 T7770D1000 CTR22-F5 n/a 5 position CTR23-F3 T7770E1023 3 position CTR23-F5 T7770F1005 5 position a A check mark ( ) indicates the feature is included with the wall module. NOTE: Refer to the CTR21, CTR22, CTR23, and CTR24 Wall Modules Installation Instructions, form 50040121-001, for wiring diagrams.some features may not be available with all controllers. 50040122-003 2

Module Dimensions WITH TEMPERATURE DIAL AND FAN SWITCH (CTR22 AND CTR23) 3 (76.5) WITHOUT TEMPERATURE DIAL OR FAN SWITCH (CTR21 AND CTR24) 4 3/4 (120) 4 9/16 70 7/8 (22) 1 7/8 (22) Circuit Board Fig. 2. Wall module dimensions in inches (mm). Fig. 3 illustrates the location of the terminal block and other features on the CTR21, CTR22, CTR23, and CTR24 models circuit board.table 2 on page 4 describes the terminal connections by model number. M28139 CTR21-J MODEL 1 CTR21 AND CTR21-A MODELS 1 CTR21-H, CTR22, CTR23, AND CTR24 MODELS 1 1 3 4 TERMINAL BLOCK 2 1 2 3 FACTORY HUMIDITY POTENTIOMETER 1 2 4 5 6 7 8 9 10 11 12 2 TERMINAL BLOCK LONTALK CONNECTOR (CTR21-J MODEL ONLY) 3 FACTORY TEMPERATURE SETPOINT POTENTIOMETER HUMIDITY SENSOR (CTR21-H AND CTR23-H ONLY) ON ON 1 2 1 2 S1 S2 ON 1 2 3 DIP SWITCH S1 DIP SWITCH S2 DIP SWITCH S3 4 5 1 COMPONENTS VARY WITH MODEL. SEE TABLE 1. LED 2 NUMBER OF TERMINALS VARIES WITH MODEL. 3 FACTORY USE ONLY. DO NOT ATTEMPT TO ADJUST. 4 DIP SWITCH S1 IS USED FOR HUMIDITY MODELS (CTR21-H AND CTR23-H) ONLY. OVERRIDE (BYPASS) PUSHBUTTON 5 SECOND SWITCH (2) ON DIP SWITCH S2 IS FOR FACTORY USE ONLY. LONTALK CONNECTOR Fig. 3. Wall module circuit board components. FAN SWITCH M28140 3 50040122-003

Wall Module Model CTR21 When Used With Controller Table 2. CTR21, CTR22, CTR23, and CTR24 Wall Module Terminal Connections. a GND b Sensor LON LON + c Terminal Usage and Number (See Fig. 3 on page 3) SETPT (Setpoint) Return LED LED Return / Fan Model(s) 1 2 3 4 5 6 7 8 9 10 11 12 CTR21-A W7761 CTR21-H CTR21-J CTR22-F5 W7750, Fan W7751, CTR23 W7752, and W7753 CT24 Excel 800, 600, 100, and 80 CTR23 CTR23-F3 Fan CTR23-F5 W7753 Fan CTR23-H CT24 CTR23 W7750, CTR23-F3 CTR23-F5 W7751, and W7752 Spyder: PUL, PVL / Fan / Fan CTR23-H CT24 CTR23-F3 Excel 800, 600, 100, and 80 CTR23-F5 with Fan CTR23 Excel 800, CTR23-H 600, 100, and 80 CT24 without Fan / Fan / Fan 18-24 Vac d a b c d A check mark ( ) indicates the terminal is used in this wall module and controller configuration. Earth Ground. LonWorks terminals (+ and ) are polarity insensitive. Power coming from the controller to power the humidity sensor. 50040122-003 4

Communications All wall modules (except the CTR21 and CTR21-A models) have a LONMARK bus communications port. If needed, the jack plug must be removed in the field, and terminals 3 and 4 wired according to the installation instructions. LONMARK bus communication is not applicable when the wall modules are used with Excel 800/600/100/80 Controllers. The LONMARK bus is insensitive to polarity, minimizing installation errors due to mis-wiring. The recommended wire size for the LONMARK bus is Level IV, 22 AWG (0.34 sq.mm) plenum or non-plenum rated, unshielded, twisted pair, solid conductor wire. CTR22 and CTR23 Setpoint Adjustment For the CTR22 and CTR23 Wall Modules with a setpoint adjustment, the controller must be programmed for the values in Table 3. DIP Switches S2 and S3 See Fig. 3 on page 3 for location of these DIP switches. To set these DIP switches, refer to the CTR21, CTR22, CTR23, and CTR24 Wall Modules Installation Instructions, form 50040121-001. CTR23 and CTR24 Wall Module (Bypass) Pushbutton and LED Operation When Used With Excel 10 Controllers: The Excel 10 controllers (W7750, W7751, W7752, and W7753) provide timed occupied and unoccupied temperature setpoints for the Wall Module, see Fig. 4. The override pushbutton is used to change the controller into the modes shown in Table 5 and illustrated in Fig. 5 on page 6. The override (bypass) LED displays the override status of the controller. Table 3. Setpoint Values. Setpoint Value Program Setting 55 F (13 C) 2.773 V 65 F (18 C) 2.148 V 75 F (24 C) 1.345 V 85 F (29 C) 0.43 V Humidity Settings (DIP switch S1) The humidity sensing control mode is set with this 2-position DIP switch. Refer to Fig. 3 on page 3 for location of DIP switch S1. NOTE: These switch settings apply only to the CTR21-H and CTR23-H models. To change the setting, first disconnect the power, then set SW1 and SW2 according to Table 4. The switch settings are used to indicate the sensing control between the humidity sensor on the wall module and the connected controller model. 70 LED 1 OVERRIDE (BYPASS) PUSHBUTTON 1 LED AND OVERRIDE (BYPASS) PUSHBUTTON AVAILABLE ONLY ON THE CTR23 AND CTR24 MODELS. M28144 Fig. 4. LED and override pushbutton locations (CTR23-F Wall Module shown). Table 5. Wall Module Operation. Pushbutton Held Down Controller Model LED Status 0 to 1 second No override Off 1 to 4 seconds Timed occupied On Table 4. DIP Switch S1 Settings. override 4 to 7 seconds Unoccupied override Single blink per second Individual Sensing Switches Longer than 7 seconds No override Off Wall Module Model Control 1 2 not applicable Continuous occupied Two blinks per second 0-10 Vdc OFF OFF override a CTR21-H CTR23-H 0-5 Vdc OFF ON a Remote function, which is generated from the network. 4-20 ma ON OFF 5 50040122-003

PRESS FOR LESS THAN ONE SECOND RESET NOT ASSIGNED (LED OFF) PRESS FOR ONE TO FOUR SECONDS BYPASS TIMEOUT When Used With Excel 10 Controllers: The Excel 10 Controllers (W7750, W7751, W7752, and W7753) can be programmed so that the fan speed switch and override button function the way that the application engineer/ programmer wants. See Table 6 for controller-programming resistances. Switch 1 on Dip Switch S2 adds 10k Ohms resistance when OPEN (for Excel 800-80 controllers) and removes it when CLOSED (for Excel 10 controllers). OVERRIDE OCCUPIED (LED ON) Table 6. Program Settings for Wall Modules with Fan Switch using Excel 10 Controllers. PRESS FOR LESS THAN ONE SECOND PRESS FOR FOUR TO SEVEN SECONDS UNOCCUPIED (LED BLINK) PRESS FOR MORE THAN SEVEN SECONDS M28145 For Switch Position Resistance (Ohms) Comment Auto 1861 ±119 Left most position 0 2686 ±127 Fan Off position 1 3866 ±139 2 304 ±130 3 460 ±146 Right most position button closed Closed circuit Fig. 5. pushbutton operation. When Used With Excel 800/600/100/80 Controllers: The application engineer/programmer can program the override (bypass) and LED to operate in any manner desired. The override (bypass) input is a dry contact, normally open, momentary digital input when the wall module does not have a fan switch. When a fan speed switch (basically a series of resistances based on fan switch position) is present, the override button is an analog input. See Table 7 for resistances. When Used With T7350 Thermostat: CTR21, CTR21-A, CTR21-H, CTR22, CTR23, and CTR24 are the models compatible with the T7350 thermostat. When using with the T7350 thermostat be sure to use the relative +/- offset knob only. The Celsius and Fahrenheit knobs will not work properly with the T7350 Thermostat. CTR22-F5, CTR23-F3, and CTR23-F5 Wall Module Fan Switch With the switch in the far left position (Auto), the fan automatically runs at the speed determined by the controller temperature control algorithm. When Used With Excel 800/600/100/80 Controllers: Excel 800/600/100/80 Controllers can be programmed so that the fan speed switch and override button function the way that the application engineer/programmer wants. See Table 7 for controller-programming resistances. Switch 1 on Dip Switch S2 adds 10k Ohms resistance when OPEN (for Excel 800-80 controllers) and removes it when CLOSED (for Excel 10 controllers). Table 7. Program Settings for Wall Modules with Fan Switch using Excel 800/600/100/80 Controllers. For Switch Position Resistance (Ohms) Comment Auto 11.861K ±119 Left most position 0 12.686K ±127 Fan Off position 1 13.866K ±139 2 13.04K ±130 3 14.60K ±146 Right most position button closed 10K ±100 With the switch in the 0 position, the fan is off. Position 1 is fan speed 1, etc. The wall module fan speed switch overrides the temperature control algorithm. 50040122-003 6

7 50040122-003

LONWORKS is a registered trademark of Echelon Corporation. LONMARK and the LonMark Logo are trademarks of the LonMark Association. Automation and Control Solutions Honeywell International Inc. Honeywell(Tianjin) Limited 1985 Douglas Drive North 158,NanHai Road,TEDA Golden Valley, MN 55422 Tianjin,300457,PRC customer.honeywell.com U.S. Registered Trademark 2008 Honeywell International Inc. 50040122-003