General Specifications

Similar documents
General Specifications

Y-Flow Field Flow Computer & Remote Terminal Unit BU 04Q01A01-01E-A

Yokogawa Y-Flow Product Family BU 04Q01A01-01E-A

Yokogawa Y-Flow Product Family. Pre-Release BU 04Q01A01-01E-A

µflo 6200 Series Overview 6200 Series Products µflo 6200 Series

JT400 Multivariable Transmitter

SCADAPack Smart RTU

XRC G Panel Mount XSeries G4 Products Remote Controller

Product Data: Micro MV 100

Self-Powered Wireless Instrumentation

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter

APP 700 Technical Specification

MMT330 Series Moisture and Temperature Transmitters for Oil

PTU300 Combined Pressure, Humidity and Temperature Transmitter

Pioneer Petrotech Services Inc. Proudly Canadian. PPS33 & 33LR RemoteWatcher Multi-Sensor Wireless Monitoring System.

EPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01

Series TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel

Yokogawa Y-Flow Master Database 62102

MODCELL 2050R Single Loop Controllers

PCS Ferguson 8000 Series Overview Manual. The PCS Ferguson 8000 Series brand is trademarked by PCS Ferguson.

WI-I/O 9 Multi I/O Units

SCADAPack 350E 357E. Smart Remote Terminal Unit

Andover ContinuumTM Infinet II

BACnet. b3810 Series Local Controllers

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Features. IDS : Inclinometer Display System with RS232 Output

Scanner 2000 microefm

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

XFC 6410, XFC 6413, and XFC 6713 XSeries Products Differential Flow Computer

XFC 6411, XFC 6414, and XFC 6714 XSeries Products Linear Flow Computer

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

LAUREL ELECTRONICS, INC.

XRC 6490, XRC 6790, and XRC 6890 XSeries Products Remote Controller

SCADAPack 32. Smart RTU

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

Gas Controller System DGC-06

FloBoss 107 Flow Manager

CDD4 Duct Carbon Dioxide Transmitter

Multi-Point Gas Detection and Control System

Phone: Fax: For calls outside the US please call:

HMIGK5310 Keypad-touchscreen panel color x 480 pixels VGA -10.4" - TFT LCD

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

Multi-Point Gas Detection and Control System

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

HMISCU6B5. Main. 60 right 40 top 60 bottom

Andover ContinuumTM. b3850 Series Terminal Controllers

DMT345 and DMT346 Dewpoint Transmitters

Andover ContinuumTM Infinet II

Online data sheet. Flow-X FLOW COMPUTER

XFC G4 XSeries G4 Products Linear Flow Computer

/8 DIN Universal Process Indicator

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

HTZ. Description. Features. Smart HART Humidity and Temperature Transmitter

DTM Distributed Transmitter Monitor

Micro Motion Model 7950 and Model 7951 Signal Converters

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

Family of Water Cut Analyzers

3000 SERIES LOW PROFILE FLOOR SCALE.

SCADAPack 312E 313E. Smart RTUs for water

Local LCD HMI - View and force I/O, and make simple configuration changes without a computer!

Flow Measurement SITRANS F US Clamp-on

High Voltage DC Meter

BACnet. b3867 Terminal Controllers

WHIRLYBIRD AUTOMATIC WEATHER STATION. Whirlybird Electronics Pvt Ltd 140, 2 nd Cross 13 th Main, BTM-I Bangalore

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

FB2100 Flow Computer. Mobile SCADA with Wi-Fi. Features. Product Data Sheet D301791X012 March Remote Automation Solutions

FloBoss TM 107/107E Flow Manager Overview

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

Meter Scanner & Controller

SCADAPack Modbus multivariable transmitter

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

Simplified information where and how you want it.

SCADAPack Modbus multivariable transmitter

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

HIGH-VOLTAGE DC METER

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

XBTGC2330T 5 7 LCD TFT color controller panel - 16 inputs/16 outputs source

iologik 2500 Series Quick Installation Guide

Multi-Point Gas Detection and Control System

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

SCADAPack 350E 357E. Smart Remote Terminal Units. Distributed by Relevant Solutions relevantsolutions.com

VC211L ELECTRONIC VOLUME CORRECTOR.

General information. Display. Supply voltage. Input current

Andover ContinuumTM Infinet II

Redundant System Redundant System P9-1-1

PDW30 Point-To-Point Wireless Bridge

System Components Guide

Temperature and Humidity Sensor

Nokeval. Where accuracy counts... Product Summary 2005 for Wireless Transmitters

Features and Benefits. Certifications

Yokogawa Y-Flow Y-Flow and Accessories

HMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs

Carbon Monoxide (CO) Gas Detection and Control System

TOTALFLOW Technical Bulletin 109

HMIGTO6315 advanced touchscreen panel stainless 800 x 600 pixels SVGA- 12.1" TFT - 96 MB

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

Transcription:

General Specifications -A Yokogawa Y-Flow YFFC Orifice Flow Computer Overview Yokogawa s low power orifice flow computer offers flexible I/O points and superior data collection with a wide range of connectivity options. By combining Yokogawa s EJX910A multivariable transmitter (DP and SP) and Y-Flow YRTU, the accuracy and stability specifications make the Y-flow a superior product with market. Whether you are measuring gas flow for custody transfer or need wellhead control and monitoring, Yokogawa offers both the performance and stability required in the most rigorous environment. API Chapter 21 compliancy AGA 3 & 5 capability AGA 8 (Detailed & Gross Methods I & II) & NX-19 Single and Bi-Directional (total vol. + avg. vol.) measurement Multiple run capability Solar panel with battery back-up or AC powered with battery back-up Wide array of wireless connectivity options (Cellular, wireless radio and satellite) Pole mount, wall mount or direct mount options Wide variety of enclosure size options Yokogawa EJX910A Multivariable Transmitter Accuracy Specifications Specifications for the EJX910A are condensed for the purpose of this document. Please see GS01C25R01-01EN for more detailed information. The EJX910A uses the established DPharp pressure sensor technology that allows for simultaneous measurement of differential pressure and static pressure (absolute or gauge) from one sensor. Out of all the Yokogawa pressure transmitters, the EJX910A has the best accuracy for combined DP and SP measurement, which makes it an excellent choice for flow calculations with a YRTU. Reference Accuracy Measurement Span/Range M H DP inh20 SP psia Span 2 to 400 145 to 3300 Range -400 to 400 0 to 3300 Span -10 to 2000 145 to 3300 Range -2000 to 2000 0 to 3300 (Includes terminal-based linearity, hysteresis, and repeatability) DP Up to ±0.04% of span standard SP ±0.1% of span (Absolute) Long Term Stability (All normal operating conditions, including overpressure effects) DP ±0.1% of URL per 10 years Turndown DP 200:1 SP 25:1 Yokogawa Corporation of America 2 Dart Road, Newnan, Georgia U.S.A. 30265

2 YFFC Technical Specification Input Power Supply Input Power: 12-30 VDC One (1) power supply/rechargeable battery input with screw terminals Integrated solar panel charger supporting up to 20W solar panel Power Monitoring and Battery Backup Supply voltage monitoring through A/D with low supply voltage alarm 3.6 VDC lithium ion battery backup for database, history, audit trial, time/date and RAM 20W on board battery charger, 90W maximum 32AH solar panel battery (optional) Performance Processor: ARM Dual Core 32 bit @ 48 Mhz SRAM Memory: 32MB SPI Flash Memory: 32MB A/D: 16-bit with optional HART filtering Display Options 4 line alphanumeric display with push button keypad Enclosure ARCA-JIC Series NEMA 4X Non-Metallic, UL 50 Compliant. Designed to NEMA 3R after milling and external mechanisms are added. Stainless steel lockable latch & continuous hinge with FIP door gasket. culus Approval: E488925 (Type 1) Enclosure Vibration Test Sweep frequency endurance test on x,y, and z axis from 10 Hz-2000Hz; with Endurance Dwell test for 15 mins at 0.5G. Based on IEC60654-3. Operating Temperature -40C to 70C (-40F to 160F) Communications Options Standard: Two (2) Serial RS-232/RS-485 One (1) Ethernet port, (1) USB Host Port, (1) USB Device Port Wireless Communication: Cellular (CDMA/GSM), Radio (spread spectrum licensed & unlicensed frequency), Satellite (LEO &GEO) Protocols: MODBUS TCP/IP, MODBUS Serial, ERC Hex ASCII (native) Input and Output (I/O) Analog Inputs: Four (4) universal analog inputs, 0-5VDC or 4-20mA (Requires 250 ohm resistor) RTD Inputs: One (1) temperature probe Digital Input/Output: Two (2) form A/C pulse input, Two (2) form C relays, Two (2) DI, Two (2) DO Optional I/O Extender Board Two (2) Serial RS-232/RS-485 Four (4) universal analog inputs One (1) analog output One (1) RTD temperature probe Two (2) form A/C pulse input Three (3) DI, Three (3) DO Opto 22 G4 Voltage Signal Conditioner Approval UL and cul Class I Div II Group A,B,C,D Software Field Manager Warranty 4 years limited warranty

3 Model Codes Model Connection 1 R/YFFC EFM- Flow Computer Multi-variable Transmitter; Range Omni (Stubby) -A7 400 0.04% 3300G 0.1% -A8 +/- 400 0.04% 3300G 0.1% -A9 2000 0.04% 3300G 0.1% -B1 +/- 2000 0.04% 3300G 0.1% Temp 1 Bulkhead Ext Serial Port 1 ESP 2 ESP Com Gear 2 6 10 A3 15 Freewave FGR Freewave MM2 Mounting A3 Freewave MM2-P-T A9 MDS EL805 Pole Mount B1 Iridium 9602 Direct Mount B2 Multi-Tech V A3 Wall Mount B3 Multi-Tech A LCD Display B5 MDS Kit B6 Freewave FGR Kit 4 Line Connection 2 A3 Keypad & 4 Line Laptop Connection Omni (Stubby) Bulkhead RS232 (MS) E3 Processor A3 USB Ethernet -A3 Full (Both) E3UES Relays; Form C Com Gear 1 - - Freewave FGR (1) Form C (2) Form C - Freewave MM2 Battery (with tray, wire & fuse) Note -A3 Freewave MM2-P-T -A9 MDS EL805 7AH -B1 Iridium 9602 -B2 Multi-Tech V -B3 Multi-Tech A -B5 MDS Kit -B6 Freewave FGR Kit A3 17AH 1 A4 32AH 2 Sample MS Code: R/YFFC-A7--A3--A4/ Notes: Note 1: 17 Ah Battery requires minimum 12x10x6 enclosure Note 2: 32 Ah Battery requires minimum 14x12x7 enclosure Note 3: Increase the enclosure size by 2

4 A6 Solar Not Attached Pressure 1 50G A8 3 Modules - 8 VDC 3 A9 3 Modules - 2x8 ; 1x35 VDC 3 B2 3 Modules - 1x8 ; 2x35 VDC 3 B4 3 Modules - 35 VDC 3 Extender A8 200G B2 500G (4) 8 VDC B5 1500G Temp 2 B7 3000G C2 C4 150HG 300HG 6 10 Pressure 2 A3 15 - Optos -A6 50G -A8 200G -B2 500G -B5 1500G -B7 3000G -C2 150HG -C4 300HG - - Red (DC Out) - Wht (DC In) -A3 Yel (AC In) -A4 Blk (AC Out) -A5 Red \ Red -A6 Red \ White Analog Out -A7 White \ White Enclosure; Dimensions in Inches Analog Output (3 chan) A4 10x10x6 SPM Signal Protection Module A5 12x10x6 A6 14x12x7 (4) 8 VDC A7 16x14x8 (4) 35 VDC A8 18x16x10 A4 8 & 35 Power Option A6 35 & 35 / Y-Flow Accessories Sample MS Code: R/YFFC-A7--A3--A4/ Notes: Note 1: 17 Ah Battery requires minimum 12x10x6 enclosure Note 2: 32 Ah Battery requires minimum 14x12x7 enclosure Note 3: Increase the enclosure size by 2 M1274XE M1274XF M1274XG M1274XH M1274XJ RS- 232 Serial PC Cable; 10 ft RS- 232 Serial PC Cable; 15 ft RS- 232 Serial PC Cable; 25 ft USB to Serial Adapter Cable USB 2.0 A-Male to B-Male 10 ft

5 YFFC Dimensional Drawing

6 E3 Processor Board Wiring

7

8 Yokogawa Corporation of America 12530 W. Airport Blvd., Sugar Land, TX 77478 yokogawa.com/us Yokogawa Canada, Inc. Bay 4, 11133 40th Street SE, Calgary, AB T2C 2Z4 yokogawa.com/ca Yokogawa de Mexico, SA de CV Urbina No. 18 Parque Industrial Naucalpan Naucalpan de Juarez, Estado de México C.P. 53370 yokogawa.com/mx