FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES

Similar documents
FCD-155. STM-1/OC-3 Terminal Multiplexer DESCRIPTION FEATURES

FCD-155 STM-1/OC-3 Terminal Multiplexer

FCD-155 STM-1/OC-3 Terminal Multiplexer

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

FCD-155 STM-1/OC-3 Terminal Multiplexer

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer

FCD-155E STM-1/OC-3 Add/Drop Multiplexer

FCD-155E STM-1/OC-3 Add-Drop Multiplexer

Optimux-34 Fiber Optic Multiplexer

Optimux-4T1 Four-Channel T1 Multiplexer

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

Gmux Modular TDMoIP Gateway FEATURES

This provides an easily configurable solution, flexible enough to meet the specific requirements of a broad range of applications.

Optimux-34, Optimux-25

Optimux-108, Optimux-106

FCD-E1E Managed E1 and Fractional E1 Access Device

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

IPmux-11. TDMoIP Gateway DESCRIPTION FEATURES

Optimux-1032, Optimux-1025

Optimux-108, Optimux-106 Four-Channel E1/T1 and Ethernet Multiplexers

ASMi-52. 2/4-Wire SHDSL Modem FEATURES

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Where to buy > Product page >

FCD-E1, FCD-T1 E1/T1 or Fractional E1/T1 Access Units

ASMi-52 2/4-wire SHDSL Modem/Multiplexer

ASMi-54 SHDSL.bis Modem

2/4-wire SHDSL Modem/Multiplexer

Optimux-108, Optimux-106

FOMi-40 Fiber Optic Modem with Remote Management

Multiservice Network Termination Unit

ASMi-54L. Data Sheet. SHDSL.bis Modem

Optimux-108, Optimux-106

MARKET SEGMENTS AND APPLICATION

ETX-102 Carrier Ethernet Demarcation Device

ASMi-54L SHDSL.bis Modem

IPmux-14. TDMoIP Gateway FEATURES DESCRIPTION

ASMi-54 SHDSL.bis Modem

Vmux-400 GSM A-bis/A-ter Optimization Gateway

IPmux-16 TDM Pseudowire Access Gateway

Megaplex-2100/2104. Data Sheet. Modular Integrated Access Multiplexers

IPmux-1E TDM Pseudowire Access Gateway

E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

Datasheet. Multi-Service Access Platform OPCOM3500E-12. OPCOM3500E-12 Feature. Raisecom Technology Co., Ltd.

RICi-16 Ethernet over Bonded PDH Network Termination Unit

IPmux-1E. TDMoIP Gateway FEATURES

E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

Vmux-2120 Voice Trunking Gateway

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer

ACE-2002, ACE-2002E. Multiservice Access Concentrators/ ATM Network Termination Units FEATURES

RICi-16 Ethernet over Bonded PDH Network Termination Unit

Vmux-210 Analog Voice Trunking Gateway

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

LA-140. Advanced ATM IAD FEATURES

ATM OVER PACKET CAPABILITIES

IPmux-14. TDM Pseudowire Access Gateway FEATURES

Vmux-110. Voice Trunking Gateway FEATURES

ACE-3000 Family ACE-3100 Cell-Site Gateway

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

ACE-3000 Family ACE-3400 Aggregation Site Gateway

ETX-201A Carrier Ethernet Demarcation Device

IPmux-4LGE TDM Pseudowire Gateway

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH. Product Brochure. Copyright: Valiant Communications Limited U.K. INDIA U.S.A.

ACE-3000 Family ACE-3200 Cell-Site Gateway

V C ALIANT OMMUNICATIONS. Product Brochure & Data Sheet

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

4 E1-4 x 10/100 Ethernet converter with VLAN

V C ALIANT OMMUNICATIONS. VCL-4 E1 + Ethernet PDH Optical Multiplexer. Data Sheet U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

FMUX1001 Modularized 16E1/T1 + 4x GbE Managed Fiber Multiplexer FMUX101 Modularized 16E1/T1 + 4x FE Managed Fiber Multiplexer

Gmux-2000 Hub-Site Pseudowire and Voice Trunking Gateway

Megaplex-4100 Next Generation Multiservice Access Node

V C ALIANT OMMUNICATIONS. VCL-Ethernet over SDH (Ethernet over STM-1) Product Brochure. Copyright: Valiant Communications Limited U.K.

IPmux-24 TDM Pseudowire Access Gateway

ACE-202/2002/2002E ATM STM-1, STM-4, IMA and ATM UNI Modules

ORION TELECOM NETWORKS INC. STM-1 (Optical / Electrical) Add-Drop Multiplexer (with upto 16 E1 & 4 Ethernet) SDH Equipment

Megaplex-4100 Next Generation Multiservice Access Node

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH (GigE) ( Gigabit Ethernet over STM- 4) Product Brochure

Loop-O9330 Fiber Optical Mux

16 x E1 G x Ethernet optical multiplexer

Protocol/interface converter series

BROAD RANGE OF INTERFACES

ORION TELECOM NETWORKS INC.

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

DXC /1/0 modular multiservice cross connect access node up to 1.2 Gbps matrix. Data Sheet. Multiservice Access Node. The Access Company

PSEUDOWIRE PERFORMANCE

RADview. Element Management System Optimux-4E1, Optimux-4T1 Optimux-4E1L, Optimux-4T1L RAD Data Communications Publication 07/05

Vmux-110 Voice Trunking Gateway for Remote Sites

SFP Transceivers Small Form-Factor Pluggable Transceivers

Loop-O 9300 Fiber Optical Mux

IPmux-216 TDM Pseudowire Access Gateway

IPmux-2L, IPmux-4L. IPmux-2L, IPmux-4L are a TDM pseudowire. also serves as an Ethernet-based access device.

ETX-203AX Carrier Ethernet Demarcation Device

SFP Transceivers Small Form-Factor Pluggable Transceivers

ORION TELECOM NETWORKS INC.

D9408 Advanced ATM Adapter

VCL-TP, Teleprotection Equipment

Megaplex-2100/2104 Modular Integrated Access Multiplexers

HS-2. MEGAPLEX-2000/2100 Module. 2-Channel High Speed Data Module DESCRIPTION FEATURES

ACE-3000 Family ACE-3105 Cell-Site Gateway. 2G, 3G and HSDPA cellular traffic over packet-switched networks (PSNs) and ATM, using DSL uplinks

Note: IPmux-155L equipped with the AC or 48 power supply modules supports up to 16 MiRICi-E3T3 units.

FOM-FXO32 / FOM-FXS32 32 Voices (FXS/FXO) POTS Fiber Multiplexer

Transcription:

FEATURES SDH/SONET terminal multiplexer for grooming LAN and legacy traffic (TDM) over SDH/SONET networks Demarcation point between the carrier and the customer networks GFP (G.7041), LAPS (X.85/86) encapsulation of Ethernet over SDH/SONET High order payload virtual concatenation mapping the Ethernet traffic over up to 3 VC-3/STS-1 links High order payload without virtual concatenation mapping the Ethernet traffic over a single VC-3/VC-4/STS-1 link Low order payload with virtual concatenation mapping the Ethernet traffic over up to 63 VC-12 or 84 VT1.5 channels Channelized STM-1/OC-3 standard main link with copper or fiber interface Optional 1+1 redundant network interface (single-ended MSP/APS) 4 E1/T1 (G.703), or single E3/T3 optional module for supporting traditional services Up to six 10/100BaseT interfaces conforming to IEEE 802.3u and 802.3x standards, two basic interfaces also supporting VLAN according to IEEE 802.1Q and 802.1p Built-in switching mechanism serves up to four remote sites in point-to-multipoint topology QoS via four priority queues per virtual group supporting 802.1p, IPv4 TOS/DiffServ and port ID Management of multiple nodes over a single shared VC-12/VT-1.5 channel, or multiplexed into virtual group traffic Management via ASCII terminal, Telnet host, Web terminal, SNMP-based network management station, or over DCC STM-1/OC-3 system clock synchronization to the network port, one of the PDH ports, or internal oscillator

DESCRIPTION FCD-155 is an SDH/SONET terminal multiplexer that enables transport of LAN and traditional (TDM) traffic over SDH/SONET networks. With bandwidth of the Ethernet channel configured in 2 Mbps (VC-12) or 1.5 Mbps (VT-1.5) increments, FCD-155 utilizes the SDH/SONET infrastructure for cost-effective Internet access and LAN connectivity. Additionally, FCD-155 supports legacy TDM-based services in the SDH/SONET environment. The basic unit includes two LAN interfaces, a single STM-1/OC-3 interface, and an AC or DC power supply. The following optional interfaces can be added to the basic unit: Four E1 or T1 interfaces Single E3 or T3 interface Second STM-1/OC-3 uplink for 1+1 link redundancy of the main link (single-ended MSP/APS). WAN INTERFACE For direct connection to the SDH/SONET network, FCD-155 has one standard network port with a software-configurable STM-1/OC-3 interface. It provides the customer with a high quality and high availability link, and performance monitoring of the traffic path. The STM-1/OC-3 link is available with a variety of fiber optic and copper coaxial connector options (see Table 1). The user can define the following SDH/SONET clock sources: Internal Recovered from the STM-1/OC-3 interface External E1. FCD-155 supports optional single-ended 1+1 redundancy mechanism (MSP/APS). Maintenance capabilities include user-activated local and remote loopbacks on the tributary E1 links. LAN INTERFACE The 10/100BaseT LAN interface supports autonegotiation for plug-and-play Ethernet connectivity. Ethernet interfaces comply with the IEEE 802.3/Ethernet V.2 standards. The two basic interfaces also include a built-in Ethernet bridge supporting VLAN according to IEEE 802.1Q and 802.1p. The Ethernet traffic is mapped into SDH/SONET containers using the following link layer protocols: Generic Framing Procedure (G.7041, FP-T1X1.5/2001-186, GFP-F) Framed mode Link Access Procedure for SDH (LAPS) protocols as per the ITU-T X.85/X.86 draft recommendations. Ethernet traffic of each user can be mapped into SDH/SONET virtual containers in any of the following ways: Up to 63 VC-12, or 64 VT-1.5 3 VC-3/STS-1 1 VC-4. APPLICATIONS Figure 1. Point-to-Point Transparent LAN and TDM Interconnection

Ethernet traffic can be switched to different bundles of virtually concatenated VCs (up to 8 bundles), according to a predefined group. Link Capacity Adjustment Scheme (LCAS) is supported in compliance with G.7042 standard, allowing adjustment of bandwidth allocated for Ethernet traffic. Ethernet packets of up to 1536 bytes can be transported over SDH media to enable connection to MPLS networks. A transparent LAN option adds four additional LAN ports directly connected to four additional virtual groups in the Ethernet mapper. This option provides totally transparent LAN extension over SDH, without bridge functionality, to create total separation between customers, for security. The maximum frame length is 2 kb. Spanning Tree Protocol (STP) and Rapid Spanning Tree Protocol (RSTP) enable Layer 2 ring applications. TDM MODULES FCD-155 has an optional four balanced E1/T1 interface ports that support transparent data transfer in compliance with G.703. A jumper-selectable unbalanced E1 interface is also available, which requires an adapter cable (see Ordering). An optional E3/T3 interface port adds support of unframed E3/T3 links over SDH/SONET. The TDM traffic is mapped into SDH VC-12/VC-11/VC-3 or SONET VT1.5/STS-1 containers that can be placed anywhere within the STM-1/OC-3 bandwidth. MANAGEMENT Remote units can be managed in the following ways: IP over DCC protocol Via dedicated virtual group containing at least one VC-12/VT-1.5 channel Inside the user traffic in a virtual group, separated from the user traffic by the GFP Channel ID or VLAN tag Out-of-band, via direct connection to one of the LAN management ports. Status and diagnostic information is defined, configured, and monitored using one of the following methods: ASCII terminal connected to the V.24/RS-232 control port Telnet host via management platform or LAN port Network management station running RADview, RAD s SNMP network management application TFTP applications for software update and remote configuration download and upload ConfiguRAD via a Web browser. DIAGNOSTICS FCD-155 has comprehensive diagnostic capabilities, including: Real-time alarms to alert the user on fault conditions. Alarms are reported to the management station and simultaneously relayed via a dry contact port. Ethernet and SDH/SONET link monitoring. Figure 2. Point-to-Multipoint Corporate Application

GENERAL An AC or DC power supply is available with an alarm-activated fan for forced air cooling. FCD-155 is a compact standalone unit. One or two units can be installed side-by-side in a 19-inch rack using the optional rack-mount adapter kit (see Ordering.) SPECIFICATIONS STM-1/OC-3 MAIN LINK (NETWORK) 1 (second link available for 1+1 MSP/APS protection) Bit Rate 155.52 Mbit/s ±20 ppm Electrical Interface Line attenuation: less than 12.7 db at 78 MHz Impedance: 100Ω Connectors: BNC coax Fiber Optic Interface Characteristics: See Table 1 Connectors: Two ST, SC, or FC/PC connectors (see Ordering) Timing Internal clock Recovered from the STM-1/OC-3 interface External E1 clock from PDH tributary Compliance SDH: ITU-T G.957 SONET: GR-253-core Framing SDH: ITU-T G.707, G.708, G.709 SONET: ANSI T1.105-1995 and GR-253-core Line Code NRZ LAN INTERFACE 2 standard, with VLAN support 4 optional, without VLAN support Compatibility Relevant sections of IEEE 802.3u, 802.3x, 802.1p, and 802.1Q Type 10BaseT: 10 Mbps 100BaseT: 100 Mbps Autonegotiation LAN Table 1,024 MAC addresses with selectable automatic aging time Connectors (per Port) RJ-45, shielded E1/T1 PDH INTERFACE (OPTION) 4 Compatibility ITU-T Rec. G.703, unframed Nominal Data Rate E1: 2.048 Mbps T1: 1.554 Mbps Line Code E1: HDB3 T1: B8ZS Interface Type Jumper selectable: E1: 120Ω balanced or 75Ω unbalanced (via adapter cable) T1: 100Ω balanced Maximum Line Attenuation 36 db (LTU mode) 12 db (DSU mode) Connectors RJ-45, shielded Timing Source clock is recovered from the receive signal coming from the remote E1/T1 side Locked to the SDH/SONET interface clock E3/T3 PDH INTERFACE (OPTION) 1 Compatibility ITU-T Rec. G.703, unframed Data Rate E3: 34.368 Mbps T3: 44.736 Mbps Framing Option Unframed Line Code E3: HDB3 T3: B3ZS Line Impedance 75Ω Connector Two BNC, female Timing Source clock is recovered from the receive signal coming from the remote E3/T3 side Locked to the SDH/SONET interface clock

INDICATORS General PWR (green) Power TST (yellow) Test MAJ ALM (red) Major alarm MIN ALM (red) Minor alarm LOC SYNC LOSS (red) Local loss of synchronization on the STM-1/OC-3 links REM SYNC LOSS (red) Remote loss of synchronization on the STM-1/OC-3 links LAN (per port) LINK (green) LAN link integrity ACT (yellow) LAN data activity E1/T1 PDH Interface (per port) SIG LOSS (red) E1 link signal loss AIS (red) AIS on E1 link E3/T3 PDH Interface SIG LOSS (red) E3/T3 link signal loss STM-1/OC-3 Main Links SIG LOSS (red) STM-1 link signal loss ON LINE (green) STM-1 link is active (indicator is on) or on standby (indicator is blinking) GENERAL Power AC: 100 to 240 VAC (±10%), 50 to 60 Hz DC: 48 VDC ( 40 to 72 VDC) Power Consumption 30W Alarms Last 100 alarms are stored and available for retrieval. Each alarm is time stamped. Alarm Relay Port Operation: normally open, normally closed, using different pins Connector: 9-pin, D-type, female Physical Height: 4.4 cm / 1.7 in Width: 21.5 cm / 8.5 in Depth: 30.0 cm / 11.8 in Weight: 2.4 kg / 5.3 lb Environment Temperature: 0 50 C/32 122 F Humidity: Up to 90%, non-condensing Wavelength [nm] Fiber Type [µm] Table 1. FCD-155 Fiber Optic Interface Characteristics Transmitter Type Power Coupled into Fiber [dbm] Receiver Sensitivity [dbm] Maximum Range [km] [miles] 1310 62.5/125 multimode LED -20 to -18-30 2 1.25 1310 9/125 single mode Laser -15 to -8-34 20 12.5 1310 9/125 single mode Laser (long haul) -5 to 0-35 40 25.0 1550 9/125 single mode Laser -15 to -8-32 20 12.5 1550 9/125 single mode Laser (long haul) -5 to 0-36 80 50.0

ORDERING FCD-155/*/&/$/#+/% STM-1 Terminal Multiplexer * Specify power supply: AC for 100 to 240 VAC 48 for 48 VDC & Specify the LAN module: 2U for 2 10/100BaseT ports 6U for 6 10/100BaseT ports $ Specify PDH module (not available with CX main link): 4E1 for 4 E1 G.703 ports 4T1 for 4 T1 G.703 ports E3 for 1 E3 G.703 port T3 for 1 T3 G.703 port Note: FCD-155 with 4 E1 ports option is delivered with balanced E1 interface. To convert a balanced interface to unbalanced, adapter cable CBL-RJ45/2BNC/E1 is available from RAD. # Specify main link connector type: CX for electrical interface with coaxial BNC connectors ST for ST type fiber connectors FC for FC/PC type fiber connectors SC for SC type fiber connectors + Specify main link optical interface wavelength and transmitter type (not relevant with CX option): 13M for 1310 nm, multimode, LED 13L for 1310 nm, single mode, laser 15L for 1550 nm, single mode, laser 13LH for 1310 nm, long haul, single mode, laser 15LH for 1550 nm, long haul, single mode, laser % Specify D for optional redundant main link (not available with CX main link) RM-35 Hardware for mounting one or two units in a 19-inch rack data communications www.rad.com International Headquarters 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel: (972) 3-6458181 Fax: (972) 3-6498250, 6474436 Email: market@rad.com U.S. Headquarters 900 Corporate Drive Mahwah, NJ 07430 Tel: (201) 529-1100 Toll free: 1-800-444-7234 Fax: (201) 529-5777 Email: market@radusa.com 180-100-10/04 1988 2004 RAD Data Communications Ltd. Specifications are subject to change without prior notice. All other trademarks are the property of their respective holders.