Retired. Is backup power creating cost and space issues in your data center racks?

Similar documents
QuickSpecs. R5000 Uninterruptible Power System (UPS) Overview

QuickSpecs. R7000 Uninterruptible Power System (UPS) Overview

QuickSpecs. HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

HP Rackmountable 3 Phase Uninterruptible Power Systems Overview

QuickSpecs. HPE Rackmountable 3 Phase Uninterruptible Power Systems. Overview. (UPS R8000/3 and R12000/3)

QuickSpecs. HP R1500 G3 Uninterruptible Power Supply (UPS) Overview

Looking for a simple and intuitive solution that allows you to access and manage servers across your entire network?

QuickSpecs HP T750 UPS. Overview

QuickSpecs. HPE Standard Power Supplies. Overview. HPE Standard Power Supplies

QuickSpecs HP R3000 UPS. Overview

Looking for a simple and intuitive solution that allows you to access and manage servers across your entire network?

R/T2000 G2 HP R/T 2200 UPS INTL HP R/T 2200 UPS JPN/TWN

QuickSpecs. HP Tower UPS T750 G2, T1000 G3, T1500 G3 Overview

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models. Overview. Retired

QuickSpecs. HP R1500 G3 Uninterruptible Power Supply (UPS) Overview. Retired

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

HP UPS R1500 XR. Overview

QuickSpecs. HP Remote Monitoring Power Distribution Units. Overview

QuickSpecs. Models HP UPS R3000 XR. Overview

QuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview

QuickSpecs. HPE Flexible Slot Power Supplies. Overview

HPE Line Interactive Single Phase Uninterruptible Power Systems (UPS) HPE R1500 G4 JP/TWN Uninterruptible Power System

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions

HP G4 Line Interactive Single Phase Uninterruptible Power Systems (UPS)

T1000 G2 and T1500 G2 1. Battery Compartment 1. Battery Compartment 2. LED display 2. LED display HP T1500 UPS INTL HP T1500 UPS JPN/TWN

QuickSpecs. HP Basic Power Distribution Units (bpdu) Overview

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

QuickSpecs. HPE Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions

QuickSpecs. HPE H220 Host Bus Adapter. Overview. Model Host Bus Adapter HP H220 Host Bus Adapter B21

QuickSpecs. HPE Basic Power Distribution Units (PDU) Overview

QuickSpecs. HPE BladeSystem c-class 40G QSFP+ to QSFP + Direct Attach Copper Cable. Overview

QuickSpecs. HPE Serial Console Server. Overview

QuickSpecs. HPE Synergy Interconnect Link Cable. Overview

QuickSpecs HP BladeSystem Breaker Panel

HP 9.5mm SATA DVD RW Optical Drive

The HPE Server Console Switch with Virtual Media is backwards compatible with all HPE Cat5 based Server Console Switches and interface adapters.

QuickSpecs. HPE 10GbE Pass-Thru Module. Overview. What's New. At A Glance

HPE HDD portfolio: Proven performance for every workload Class Enterprise Midline Entry* Workload High Medium Low

HP SATA DVD RW Optical Drives Overview. HP 9.5mm SATA DVD RW Optical Drive

QuickSpecs. Why do you need a KVM Console for your rack? Why HP? HP KVM Console Kit. Overview

HPE HDD portfolio: Proven performance for every workload Class Enterprise Midline Entry* Workload High Medium Low

QuickSpecs. HPE Common Slot Power Supplies. Overview

QuickSpecs. What's New Updating list of supported servers. HP Half-Height SATA DVD RW Optical Drive. Overview

QuickSpecs. What's New Updating list of supported servers. HP Half-Height SATA DVD ROM Optical Drive. Overview

Retired. Full Rack Vertical PDU Model (Ideal for 36U to 47U racks)

QuickSpecs. What's New 300GB 6G SAS 15K rpm SFF (2.5in) Enterprise Hard Drive. HP SAS Enterprise and SAS Midline Hard Drives.

New G2 features allow for greater management of power and environment in IT racks

QuickSpecs. HP Parallel 3 Phase Uninterruptible Power Systems. Overview

HP 10GbE Pass-Thru Module

QuickSpecs. HPE UPS Network Module. Overview. Models HPE UPS Network Module Mini-slot Kit

QuickSpecs. HPE Apollo 6000 Power Shelf. Overview

QuickSpecs. HPE SATA Hard Drives. Overview. HPE Hard Disk Drives

QuickSpecs. HPE G2 Metered Power Distribution Units. Overview HPE G2 Metered Power Distribution Units

QuickSpecs. What's New. Models. HP SATA Hard Drives. Overview. HP 6G SATA SmartDrive Carriers

QuickSpecs. HP SAS Hard Drives. Overview

QuickSpecs. Model Host Bus Adapter HP H222 Host Bus Adapter B21. HP H222 Host Bus Adapter. Overview

HP Uninterruptible Power Supplies Overview

QuickSpecs. HPE Intelligent Power Distribution Unit (PDU) Overview

QuickSpecs. What's New HP 1.2TB 6G SAS 10K rpm SFF (2.5-inch) SC Enterprise 3yr Warranty Hard Drive

QuickSpecs. HPE Synergy QSFP+ Transceiver. Overview. HPE Synergy QSFP+ Transceiver. Page 1

QuickSpecs. What's New. Models. HP SATA Hard Drives. Overview

The HP Server Console Switch with Virtual Media is backwards compatible with all HP Cat5 based Server Console Switches and interface adapters.

QuickSpecs HP Rack 5642

QuickSpecs. HP PCIe IO Accelerators for ProLiant Servers. Overview

QuickSpecs. HP SATA Hard Drives. Overview

QuickSpecs. HP Server Console Switches Overview

QuickSpecs. HPE Single Phase Tower UPS. Overview and Models. HPE Single Phase Tower Uninterruptible Power Systems (UPS) Why HPE Tower UPS solutions?

HPE HDD portfolio: Proven performance for every workload Class Enterprise Midline Entry* Workload High Medium Low

QuickSpecs. HPE KVM IP Console Switch. Overview

PCIe Workload Accelerators HH/HL

QuickSpecs. HPE Synergy 10Gb Pass-Thru Module. Overview. At A Glance

UPS R12000 XR, N+X. Overview

Premium Online Series

QuickSpecs. HPE Intelligent Power Distribution Unit (PDU) Overview

HPE recommended options have best performance, value and availability.

HPE T1500 Gen5 NA/JP UPS with Management Card Slot HPE T1500 Gen5 INTL UPS with Management Card Slot

QuickSpecs. HP PCIe IO Accelerators for ProLiant Servers. Overview

Setting new standards for reliable power distribution and metering

Uninterruptible Power Supplies

QuickSpecs. HPE IP KVM Console Switch G2 with Virtual Media & CAC. Overview

QuickSpecs. HP Modular Cooling System. Overview

Mellanox InfiniBand (IB) EDR Switches are supported to work with HPE InfiniBand Adapters to deliver high performance

QuickSpecs. HPE Ethernet 1Gb 2-port 332T Adapter

QuickSpecs. HPE Ethernet 1Gb 2-port 332T Adapter. Overview

QuickSpecs. HP IP Console Switch with Virtual Media Overview

HPE HDD portfolio: Proven performance for every workload Class Enterprise Midline Entry* Workload High Medium Low

QuickSpecs. What's New New USB interface adapter compatible with CAC and virtual media. HP KVM Server Console Switch G2 with Virtual Media & CAC

HP ProLiant m300 1P C2750 CPU 32GB Configure-to-order Server Cartridge B21

Retired. Models HP NC340T PCI-X 4-port 1000T Gigabit Server Adapter B21

QuickSpecs. What's New New HP221 PCIe 3.0 SAS HBA

QuickSpecs. HPE IP KVM Console Switch G2 with Virtual Media & CAC. Overview

QuickSpecs. What's New New for Smart Array Advanced Pack 2.0: Features are base offering on HP Smart Array P222, P420i, P420, and P421.

QuickSpecs. What's New. Models. HP SATA Hard Drives. Overview

Retired. HP TFT7600 Rackmount Keyboard and Monitor (TFT7600 RKM) Overview

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

QuickSpecs. HPE SAS Hard Drives. Overview. What's New

HPE HDD portfolio: Proven performance for every workload Class Enterprise Midline Entry* Workload High Medium Low

Retired. HP NC7771 PCI-X 1000T Gigabit Server Adapter Overview

Transcription:

Overview Is backup power creating cost and space issues in your data center racks? The HPE DirectFlow (DF) Uninterruptible Power System (UPS) is a scalable and modular UPS that provides a high-density backup power solution for Hewlett Packard Enterprise servers and storage. It features a separate power management unit that integrates the major stages of an UPS - charger, inverter and active filter - into a single compact unit that dramatically reduces both size and cost when compared to a traditional UPS. The DirectFlow UPS provides up to 15kVA (3U) or 19.9kVA (5U) of power, utilizing 1U (Lithium-Ion) or 3U (Valve Regulated Lead Acid) battery pack options. HPE's DirectFlow UPS technology creates a highly efficient backup power solution by removing the active front-end AC/DC power conversion steps, delivering an efficiency exceeding 99%. DirectFlow UPS technology also includes integrated Active Current Correction that enables power factor closer to unity in low-load conditions, providing clean power that ultimately lowers your power costs. Power Unit (1U UPS) NOTE: #0D1 will appear after the part number on the sales order if HPE factory integration is indicated. HPE R12000 DirectFlow - 1U Rackmount Uninterruptible Power System HPE R12000 DirectFlow - POD 1U Rackmount Uninterruptible Power System G9Y75A AF478A Input/Output Module Options for 1U UPS Choose one I/O Module per UPS NOTE: #0D1 will appear after the part number on the sales order if HPE factory integration is indicated. HPE 32A 400-415 Volt Three Phase INTL R12000 DirectFlow UPS IEC309 Input/Output Module AF488A HPE 30A 400-415 Volt Three Phase NA R12000 DirectFlow UPS POD IEC309 Input/Output Module AF489A HPE 32A 380 Volt Three Phase China R12000 DirectFlow UPS Unterminated Input/Output Module AF490A HPE 30A 480 Volt Three Phase NA R12000 DirectFlow UPS L22-30 Input/Output Module AF491A HPE 30A 480 Volt Three Phase NA R12000 DirectFlow UPS IEC309 Input/Output Module AF492A HPE 30A 400-415 Volt Three Phase NA R12000 DirectFlow UPS IEC309 Input/Output Module NOTE:NOTE: All Input/Output Modules support dual output outlets except the AF484A. G9Y76A Power Unit (2U UPS) NOTE: #0D1 will appear after the part number on the sales order if HPE factory integration is indicated. HPE R18000 DirectFlow - 2U Rackmount Uninterruptible Power System AF479A Page 1

Overview Input/Output Module Options for 2U UPS Choose one I/O Module per UPS NOTE: #0D1 will appear after the part number on the sales order if HPE factory integration is indicated. HPE 32A 400-415 Volt Three Phase INTL R18000 DirectFlow UPS IEC309 I/O Module AF483A HPE 30A 380 Volt Three Phase China R18000 DirectFlow UPS Unterminated I/O Module AF485A HPE 30A 480 Volt Three Phase NA DirectFlow UPS NEMA L22-30 I/O Module AF486A HPE 30A 480 Volt Three Phase NA R18000 DirectFlow UPS IEC309 Input/Output Module AF487A HPE 30A 400-415V Three Phase NA R18000 DirectFlow UPS IEC309 Input/Output Module D9Q02A HPE 30A 400-415V Three Phase NA R18000 DirectFlow UPS 1:1 IEC309 I/O Module NOTE:NOTE: All Input/Output Modules support dual output outlets except the AF484A. AF484A Battery Pack Options - Choose up to two Battery Packs per UPS (must be the same) NOTE: #0D1 will appear after the part number on the sales order if HPE factory integration is indicated. HPE DirectFlow UPS - 1U Rackmount Lithium-ion Battery Pack AF480A HPE DirectFlow UPS - 3U Rackmount VRLA Battery Pack AF482A HPE R12000 DirectFlow UPS (front panel) 1 UPS fault LED 5 Up arrow 2 Bypass mode LED 6 Down arrow 3 Battery mode LED 7 Off/ESC/Clear fault button 4 Input LED 8 On/Enter button HPE R12000 DirectFlow UPS (rear panel) Page 2

Overview 1 Cover plate for option slot 5 Battery pack power cable 2 REPO port 6 I/O power module connection 3 DB-9 serial port (firmware 7 I/O power module connection upgrade) 4 DB-15 port (CAN Bus cable) Page 3

Overview HPE R12000 DirectFlow UPS (rear panel with UPS Management Card and I/O Module installed) 1 HPE DirectFlow UPS Management Module card 2 HPE DirectFlow Input/Output Power Module switch 3 HPE DirectFlow Input/Output Power Module connection and cables HPE R12000 DirectFlow UPS (rear panel with UPS Management Card installed, no I/O module) 1 RJ-45 for network or Ethernet communications 2 DB-9 serial port for configuration and flashing card firmware 3 Power LED 4 Health/Alert LED Page 4

Overview HPE R18000 DirectFlow UPS (front panel) 1 UPS fault LED 5 Up arrow 2 Bypass mode LED 6 Down arrow 3 Battery mode LED 7 Off/ESC/Clear fault button 4 Input LED 8 On/Enter button HPE R18000 DirectFlow UPS (rear panel) 1 Cover plate for option slot 5 Battery pack power cable 2 REPO port 6 I/O power module connection 3 DB-9 serial port (firmware 7 I/O power module connection upgrade) 4 DB-15 port (CAN Bus cable) Page 5

Overview HPE R18000 DirectFlow UPS (rear panel with UPS Management Card and I/O Module installed) 1 UPS Management Module card 2 Input/Output Power Module switch 3 Input/Output Power Module connection and cables HPE R18000 DirectFlow UPS (rear panel with UPS Management Card installed, no I/O module) 1 Power LED 2 Health/Alert LED 3 DB-9 serial port (configuration/firmware upgrade) 4 RJ-45 (Network/Ethernet communications) Page 6

Overview 3U Battery Pack (VRLA) 1 DC to DC power cable connector (power unit) 2 DC to DC power cable connector (battery pack) 3 DB-15 ports (CAN Bus cables for battery pack communication) 4 Circuit breaker switch 1U Battery Pack (Li-ion) 1 DC to DC power cable connector (power unit) 2 Circuit breaker switch 3 DC to DC power cable connector (battery pack) 4 DB-15 ports (CAN Bus cables for battery pack communication) Page 7

Standard Features Key Features and Benefits Modular And Scalable Design Creates High Density Backup Power Solution Separate power management unit that integrates the major stages of an UPS - charger, inverter and active filter - into a single compact unit that dramatically reduces both size and cost when compared to a traditional UPS High power density solution that provides up to 19.9kVA in a 5U space and as much as 12kVA in a 2U space Increase system runtime by 3x with parallel able 1U (Lithium-Ion) and 3U (Valve Regulated Lead Acid) battery pack options Modular input/output modules accommodate different regional input voltage requirements using the same power management unit and battery options worldwide Highly Efficient Backup Power Solution That Lowers Your Total Cost Of Ownership Utilizes an advanced technology that removes the active front-end AC/DC power conversion steps and delivers power efficiency exceeding 99% Integrates Active Current Correction (ACC) technology that enables power factor closer to unity in low-load conditions, ultimately lowering the data center power bill Utilizes Digital Signal Processing (DSP) technology that continually conditions and regulates power without using the battery, thereby increasing the life of the battery Flexible Design Allows for Simple Configuration, Management, and Maintenance Easy configuration and user-friendly operation supported through an enhanced LCD display and remote web-based management capabilities Separation of power management unit and battery creates a distributed backup power solution with no single point of failure Hot-swappable power management unit and battery modules that include a Modular Bypass mode that allows loads to be continuously powered while servicing the UPS High Power Density Up to 6kVA of power per U of rack space: 19.9kVA in 5U space = 2U DirectFlow UPS + 3U VRLA Battery option 15kVA in 3U space = 2U DirectFlow UPS + 1U Li-Ion Battery option 12kVA in 2U space = 1U DirectFlow UPS + 1U Li-Ion Battery option Innovative Technology Drives Lower TCO HPE DirectFlow technology creates a highly efficient backup power solution by removing the active front-end AC/DC power conversion steps, delivering an efficiency exceeding 99% Integrated Active Current Correction technology enables power factor closer to unity in lowload conditions, providing clean power that ultimately lowers your power costs Includes HPE exclusive battery management software that helps to extend the service life of the battery Better Reliability Innovative design enables efficient management of unbalanced loads Able to detect and handle generator input on programming, making efficient use of available power for load and charging when required Programmable runtime limits, input types, and charging output power Page 8

Standard Features HPE Battery Management The DirectFlow UPS communicates with the battery management system to learn the voltages and states of charge for each battery module. The helps the UPS to better understand the condition and usability of the battery, and informs the user when it is time for the battery to be serviced. UPS/Battery Monitoring The DirectFlow UPS provides both a serial communications port (RS232) and CAN bus for local connection to the UPS and battery modules. Remote monitoring is also supported via two methods: Optional UPS Management Card (internal) Optional Advanced Power Manager (APM) Kit (external) Compatibility Warranty Compatible with all HPE V142, 11000G2 and Intelligent Series Racks, as well as with all HPE Power Distribution Units (PDUs), servers, networking and storage products. HPE R12000 and R18000 DirectFlow UPS and I/O Module options: covered by a three year warranty (3/1/1), with the first year including parts and labor. HPE DirectFlow 1U Battery Module (Li-Ion): covered by a four year warranty (4/1/1), with the first year including parts and labor. HPE DirectFlow 3U Battery Module (VRLA): covered by a two year warranty (2/1/1), with the first year including parts and labor. Page 9

Service and Support Service and Support NOTE: HPE DirectFlow 1U Uninterruptible power system is supported as a part of the HPE Server Infrastructure. No separate HPE Care Packs needs to be purchased. The Support recommendation listed below are only for the 2U UPS. HPE Technology Services for Industry Standard Servers HPE Technology Services delivers confidence, reduces risk and helps customers realize agility and stability. Connect to HPE to help prevent problems and solve issues faster. Our support technology lets you to tap into the knowledge of millions of devices and thousands of experts to stay informed and in control, anywhere, any time. Protect your business beyond warranty with HPE Pointnext operational services HPE Pointnext operational services enable you to order the right service level, length of coverage and response time as you purchase your new server, giving you full entitlement for the term you select. Recommended HPE Pointnext operational services for 2U Uninterruptible Power System Optimized Care Supports maintaining servers at optimum performance availability HPE Proactive Care Advanced Call to Repair, three year Care Pack Service Achieve a higher return on your product investment with the personal attention from a locally assigned Account Support Manager who delivers recommendations designed to improve availability and performance. Leverage your system s ability to connect to HPE for automated problem detection and rapid critical event management to increase stability and reduce unplanned downtime. This recommendation provides a local customer engineer for onsite hardware repair if required within 6 hours and two-hour callback for supported software. Collaborative call management comes with Proactive Care Advanced or you may choose full support from HPE where we own all cases through to resolution. https://www.hpe.com/h20195/v2/getdocument.aspx?docname=4aa5-3259enw&cc=us&lc=en Standard Care Supports maintaining high level of server availability HPE Proactive Care with 6 hour call-to-repair commitment, three year Care Pack Service HPE Proactive Care helps prevent problems and stabilize IT by utilizing secure, real-time, predictive analytics and proactive consultations when your products are connected to HPE. This Care Pack Service combines three years proactive reporting and advice with our highest level reactive coverage and enhanced escalation management, HPE s 24x7, six hour call-to-repair hardware commitment. Hewlett Packard Enterprise is the only leading manufacturer who makes this level of coverage available as a standard service offering for your most valuable servers. Service includes 24x7 collaborative software support for leading industry standard software running on your HPE ProLiant server. https://www.hpe.com/h20195/v2/getpdf.aspx/4aa3-8855enw.pdf Basic Care Supports maintaining minimum level of server availability Foundation Care 24x7, three-year Care Pack Service HPE Foundation Care 24x7 connects you to HPE 24 hours a day, seven days a week for assistance on resolving issues. Hardware onsite response within four hours if needed; collaborative software included in this Care Pack service provides troubleshooting assistance on industry leading software running on your HPE server. Simplify your support experience and make HPE your first call for hardware or software questions. https://www.hpe.com/h20195/v2/getdocument.aspx?docname=4aa4-8876enw&cc=us&lc=en Get connected to HPE to Connecting products to Hewlett Packard Enterprise will help prevent problems with 24x7monitoring, Page 10

Service and Support improve your support experience Parts and materials prefailure alerts, automatic call logging, and parts dispatch, plus current data will be available for the proactive reports that are part of Proactive Care Services. With Connected products, you can have a dashboard to manage your IT anywhere, anytime, from any device. Hewlett Packard Enterprise will provide HPE-supported replacement parts and materials necessary to maintain the covered hardware product in operating condition, including parts and materials for available and recommended engineering improvements. Parts and components that have reached their maximum supported lifetime and/or the maximum usage limitations as set forth in the manufacturer's operating manual, product quick-specs, or the technical product data sheet will not be provided, repaired, or replaced as part of these services. The defective media retention service feature option applies only to Disk or eligible SSD/Flash Drives replaced by Hewlett Packard Enterprise due to malfunction. Coverage For more information Coverage of the UPS battery is not included beyond the term of the UPS warranty; standard warranty terms and conditions apply. To learn more on services for HPE ESSN Options, please contact your Hewlett Packard Enterprise sales representative or Hewlett Packard Enterprise Authorized Channel Partner. Or visit: http://www.hp.com/services/proliant or http://www.hp.com/services/bladesystem Page 11

Related Options HPE DirectFlow UPS Options NOTE: #0D1 will appear after the part number on the sales order if HPE factory integration is indicated. HPE DirectFlow UPS HPE DirectFlow UPS - 1U Rackmount Lithium-ion Battery Pack Battery Options HPE DirectFlow UPS - 3U Rackmount VRLA Battery Pack NOTE:NOTE: Primary and secondary batteries used in the DirectFlow UPS must be the same type. AF480A AF482A R12000 1U I/O Module Options HPE 32A 400-415 Volt Three Phase INTL R12000 DirectFlow UPS IEC309 Input/Output Module HPE 30A 400-415 Volt Three Phase NA R12000 DirectFlow UPS POD IEC309 Input/Output Module HPE 32A 380 Volt Three Phase China R12000 DirectFlow UPS Unterminated Input/Output Module HPE 30A 480 Volt Three Phase NA R12000 DirectFlow UPS L22-30 Input/Output Module HPE 30A 480 Volt Three Phase NA R12000 DirectFlow UPS IEC309 Input/Output Module HPE 30A 400-415 Volt Three Phase NA R12000 DirectFlow UPS IEC309 Input/Output Module AF488A AF489A AF490A AF491A AF492A G9Y76A R18000 2U I/O Module Options HPE 32A 400-415 Volt Three Phase INTL R18000 DirectFlow UPS IEC309 I/O Module HPE 30A 380 Volt Three Phase China R18000 DirectFlow UPS Unterminated I/O Module HPE 30A 480 Volt Three Phase NA DirectFlow UPS NEMA L22-30 I/O Module HPE 30A 480 Volt Three Phase NA R18000 DirectFlow UPS IEC309 Input/Output Module HPE 30A 400-415V Three Phase NA R18000 DirectFlow UPS IEC309 Input/Output Module HPE 30A 400-415V Three Phase NA R18000 DirectFlow UPS 1:1 IEC309 I/O Module NOTE:NOTE: All Input/Output Modules support dual output outlets except the AF484A. AF483A AF485A AF486A AF487A D9Q02A AF484A Secondary Battery Cable HPE WW DirectFlow Secondary Battery Cable NOTE:NOTE: Required when adding a secondary battery to either the R12000 or R18000 DirectFlow UPS. AF497A Page 12

HPE Directflow Three Phase Uninterruptible Power System Related Options UPS Management Card HP DirectFlow UPS Management Card AF493A (Internal) UPS Management Card (External) HP SL Advanced Power Manager Kit 538084-B21 NOTE: HPE Comm Micro DB9F/DB9M Cable (E2D31A) required when using this external UPS management card. External UPS Management Cable Kit HP Communication Micro DB9 Female to DB9 Male Black 3.0m 1-pack Serial Cable E2D31A NOTE: Cable kit required when HPE SL Advanced Power Manager Kit (538084-B21) is used with R18000 UPS. Page 13

Maximum Output Power UPS Model Input/Output Module Max Power (kva) - VRLA Battery Max Power (kva) Li-Ion Battery HPE R12000 1U HPE 32A 400-415 Volt Three Phase INTL R12000 12000 12000 Direct Flow UPS DirectFlow UPS IEC309 Input/Output Module HPE 30A 400V NA R12000DF IEC309 POD Mod 12000 12000 HPE 32A 380 Volt Three Phase China R12000 DirectFlow 12000 12000 UPS Unterminated Input/Output Module HPE 30A 480 Volt Three Phase NA R12000 DirectFlow UPS 12000 12000 L22-30 Input/Output Module HPE 30A 480 Volt Three Phase NA R12000 DirectFlow UPS 12000 12000 IEC309 Input/Output Module HPE 30A 400-415 Volt Three Phase NA R12000 DirectFlow 12000 12000 UPS IEC309 Input/Output Module HPE R18000 2U HPE 32A 400-415 Volt Three Phase INTL R18000 19900 15000 Direct Flow UPS DirectFlow UPS IEC309 Input/Output Module HPE 30A 380 Volt Three Phase China R18000 DirectFlow 19900 15000 UPS Unterminated Input/Output Module HPE 30A 480 Volt Three Phase NA R18000 DirectFlow UPS 19900 15000 L22-30 Input/Output Module HPE 30A 480 Volt Three Phase NA R18000 DirectFlow UPS 19900 15000 IEC309 Input/Output Module HPE 30A 400 Volt Three Phase NA R18000 DirectFlow UPS 19900 15000 IEC309 Input/Output Module HPE 30A 400-415V Three Phase NA R18000 DirectFlow UPS 1:1 IEC309 Input/Output Module 19900 15000 Page 14

Estimated Runtime (Minutes) R12000 Runtime with 3U VRLA Battery Pack Load Load % (kva) (3UBP) Minimum Minutes (1 B:P) 12 100 4:21 12:53 9 75 6:56 19:04 6 50 11:25 31:32 3 25 29:35 71:22 Minimum Minutes (2 BPs Parallel) R18000 Runtime with 3U VRLA Battery Pack Load Load % (kva) (3UBP) Minimum Minutes (1 B:P) 4.5 25.00 13 42 9 50.00 7 18 12 66.67 4 13 13.5 75.00 4 11 15 83.33 3 10 17.7 98.33 2 8 18 100.00 2 7 Minimum Minutes (2 BPs Parallel) R18000 Runtime with 1U Lithium Ion Battery Pack Load (kva) Load % (1UBP) Minimum Minutes (1 BP) Minimum Minutes (2 BPs Parallel) 3.75 25 9 21 7.5 50 5 10 11.25 75 2 6 12 80 2 6 15 100 1 5 NOTE: Runtimes may change based on aging of the batteries and ambient temperature. Runtimes shown here are conservative values based on test results. Page 15

Technical Specifications HPE R12000 DirectFlow 1U UPS BTU Break Down Based on efficiency of unit on battery BTU On Battery with VRLA Battery Option BTU On Battery with Li-Ion Battery Option Battery String Voltage Battery Type Battery Quantity AC Mode Efficiency = 0.94 DC Mode Efficiency = 0.91 Output Power = 12000 W AC Mode without charging = 2611.91 BTU/hr Battery Mode = 4047.03 BTU/hr AC Mode Efficiency = 0.94 DC Mode Efficiency = 0.90 Output Power 12000W AC Mode without charging = 2611.11 BTU/hr. Battery Mode = 4546.67 BTU/hr. 432V (VRLA), 376V (Li-Ion) 12V 3.5Ah (VRLA), 4.1V, 1.5Ah (Li-Ion) 4 strings with 9 batteries per string (VRLA) per battery tray, 8 modules in series with 12 2-parallel cells in series (Li-Ion) per battery tray. Electrical Input Voltage Range 480/415/400/380V +10/-15% (Wye) Frequency 50/60 Hz Input Plug I/O module with IEC 309 32P/ IEC 309 32R, IEC 309 20P, IEC 309 20R, NEMA L22 30P/ NEMA L22 30C plug depending on operating voltage. The I/O module has one input plug and one output receptacle. Online Efficiency >94% REPO Remote Emergency Power-Off disables AC power to load Electrical Output Voltage Range 480/415/400/380V Wye Line to Line (277/240/230/220V Wye Line to Neutral) Online Regulation ±5% of nominal voltage On-Battery Regulation ±5% of nominal voltage Voltage Wave Form Sine wave Connections I/O module with IEC 309 32P/ IEC 309 32R, IEC 309 20P, IEC 309 20R, NEMA L22 30P/ NEMA L22 30C plug depending on operating voltage. The I/O module has one input plug and one output receptacle. Output Protection Overcurrent and short circuit protection through output current feedback. Inverter and output SCRs, Inverter fuses. Battery Type Maintenance-free, sealed, valve-regulated lead acid (VRLA); Lithium-Ion Phosphate (Li-Ion) Extended Batteries Up to two battery packs in parallel supported must be the same type of battery Backup Time See Estimated Runtime chart Recharge Time <1 hours to 80% usable capacity; <4 hours for complete recharge for Li- Ion; <3 hours to 80% and <24 hours for complete recharge for VRLA batteries Battery Voltage 432V (VRLA), 376V (Li-Ion) Battery Type 12V 3.5Ah (VRLA), 4.1V, 1.5Ah (Li-Ion) Battery Quantity 4 strings with 9 batteries per string (VRLA) per battery tray; 8 modules in series with 12 2-parallel cells in series (Li-Ion) per battery tray. Maximum Power With VRLA Battery With Li-Ion Battery 12000VA 12000VA Communications Serial Ports Standard DB-9 port and DB-15 CAN port Page 16

Technical Specifications Environmental and Safety Optional LCD/LED Indicators Operating Temperature Transit Temperature Storage Temperature Operating Humidity Storage Humidity Operating Altitude Transit Altitude Safety Markings Safety Certifications EMC Markings Emissions REPO Port HPE UPS Management Module Card (Internal) HPE Advanced Power Manager (External) LCD screen with two scroll buttons, one ESC and one RETURN button. 4 LEDs (AC Input On, Battery Mode On, Manual Bypass On, and Fault) 10 to 35 C (50 to 95 F) at sea level with an altitude derating of 1.0 C per every 305 m (1.8F per every 1000 ft.) above sea level to a maximum of 3050 m (10,000 ft.), no direct sustained sunlight. Maximum rate of change is 10 C/hr. (18 F/hr.). The upper limit may be limited by the type and number of options installed. System performance may be reduced if operating with a fan fault or above 30 C (86 F). NOTE: Operating temperature assumes rated load and nominal utility. -25 to 60 C -25 to 55 C 5-95 %, Non-condensing 5-95 %, Non-condensing 10,000 ft. above sea level 30,000 ft. above sea level NA: UL, cul International: TUV, CE UL1778, UL60950-1; CSA22.2 No.107.3-05, EN60950-1 IEC62040-1 NA/JPN: FCC, VCCI, ICES, CISPR International: CISPR FCC CFR 47, Part 15 Class A, ; EN62040-2 Meets NEC code 645-11 intent and UL requirements Status Indicator On/Enter button Press the button for 3 seconds to turn the UPS on; press the button to confirm setup or menu entries UPS fault LED Red light indicates a fault; no light indicates proper function Bypass mode LED Green light indicates Bypass mode; no light indicates AC mode Battery mode LED Yellow light indicates Battery mode; flashing indicates low battery Input LED Green light indicates that the power input is adequate Off/ESC/Clear fault button In AC mode, press the button for 3 seconds to transfer the UPS to Bypass mode; in Battery mode, press for 3 seconds to shut down the UPS output During menu selection, press the button to go back to the previous menu During a UPS fault, press the button for 3 seconds to clear the fault and transfer the UPS to Bypass mode Kit Contents Power Unit (UPS) I/O Modules HPE R12000 DirectFlow 1U UPS unit; documentation; depth adjustable fixed rack mounting rails, mounting brackets; Front bezel HPE DirectFlow 1U I/O Module; documentation HPE R18000 DirectFlow 2U UPS BTU Break Down Based on efficiency of unit on battery BTU On Battery with VRLA Battery Option AC Mode Efficiency = 0.98 DC Mode Efficiency = 0.91 Output Power = 19944 W AC Mode without charging = 1388 BTU/hr Battery Mode = 6726 BTU/hr BTU On Battery with AC Mode Efficiency = 0.98 Page 17

Technical Specifications Li-Ion Battery Option DC Mode Efficiency = 0.90 Output Power 15000W AC Mode without charging = 1044 BTU/hr. Battery Mode = 5683 BTU/hr. Battery String Voltage 432V (VRLA), 376V (Li-Ion) Battery Type 12V 3.5Ah (VRLA), 4.1V, 1.5Ah (Li-Ion) Battery Quantity 4 strings with 9 batteries per string (VRLA) per battery tray, 8 modules in series with 12 2-parallel cells in series (Li-Ion) per battery tray. Electrical Input Voltage Range 480/415/380V +10/-15% (Wye) Frequency 50/60 Hz Input Plug I/O module with IEC 309 32P/ IEC 309 32R, IEC 309 20P, IEC 309 20R, NEMA L22 30P/ NEMA L22 30C plug depending on operating voltage. The I/O module has one input plug and one output receptacle. Online Efficiency >97% REPO Remote Emergency Power-Off disables AC power to load Electrical Output Voltage Range 480/415/380V +10/-15% (Wye) Online Regulation ±5% of nominal voltage On-Battery Regulation ±5% of nominal voltage Voltage Wave Form Sine wave Connections I/O module with IEC 309 32P/ IEC 309 32R, IEC 309 20P, IEC 309 20R, NEMA L22 30P/ NEMA L22 30C plug depending on operating voltage. The I/O module has one input plug and one output receptacle. Output Protection Overcurrent and short circuit protection through output current feedback. Inverter and output SCRs, Inverter fuses. Battery Type Maintenance-free, sealed, valve-regulated lead acid (VRLA); Lithium-Ion Phosphate (Li-Ion) Extended Batteries Up to two battery packs in parallel supported must be the same type of battery Backup Time See Estimated Runtime chart Recharge Time <1 hours to 80% usable capacity; <4 hours for complete recharge for Li- Ion; <3 hours to 80% and <24 hours for complete recharge for VRLA batteries Battery Voltage 432V (VRLA), 376V (Li-Ion) Battery Type 12V 3.5Ah (VRLA), 4.1V, 1.5Ah (Li-Ion) Battery Quantity 4 strings with 9 batteries per string (VRLA) per battery tray; 8 modules in series with 12 2-parallel cells in series (Li-Ion) per battery tray. Maximum Power With VRLA Battery With Li-Ion Battery 19900VA 15000VA Communications Serial Ports Standard DB-9 port and DB-15 CAN port Optional HPE UPS Management Module Card (Internal) HPE Advanced Power Manager (External) LCD/LED Indicators LCD screen with two scroll buttons, one ESC and one RETURN button. 4 LEDs (AC Input On, Battery Mode On, Manual Bypass On, and Fault). Environmental and Safety Operating Temperature 10 to 35 C (50 to 95 F) at sea level with an altitude derating of 1.0 C per every 305 m (1.8F per every 1000 ft.) above sea level to a maximum of 3050 m (10,000 ft.), no direct sustained sunlight. Maximum rate of change is 10 C/hr. (18 F/hr.). The upper limit may be limited by the type and number of options installed. System performance may be reduced if operating with a fan fault or above 30 C (86 F). Page 18

Technical Specifications Transit Temperature Storage Temperature Operating Humidity Storage Humidity Operating Altitude Transit Altitude Safety Markings Safety Certifications EMC Markings Emissions REPO Port NOTE: Operating temperature assumes rated load and nominal utility. -25 to 60 C -25 to 55 C 5-95 %, Non-condensing 5-95 %, Non-condensing 10,000 ft. above sea level 30,000 ft. above sea level NA: UL, cul International: TUV, CE UL1778, UL60950-1; CSA22.2 No.107.3-05, EN60950-1 IEC62040-1 NA/JPN: FCC, VCCI, ICES, CISPR International: CISPR FCC CFR 47, Part 15 Class A, ; EN62040-2 Meets NEC code 645-11 intent and UL requirements Status Indicator On/Enter button Press the button for 3 seconds to turn the UPS on; press the button to confirm setup or menu entries UPS fault LED Red light indicates a fault; no light indicates proper function Bypass mode LED Green light indicates Bypass mode; no light indicates AC mode Battery mode LED Yellow light indicates Battery mode; flashing indicates low battery Input LED Green light indicates that the power input is adequate Off/ESC/Clear fault button In AC mode, press the button for 3 seconds to transfer the UPS to Bypass mode; in Battery mode, press for 3 seconds to shut down the UPS output During menu selection, press the button to go back to the previous menu During a UPS fault, press the button for 3 seconds to clear the fault and transfer the UPS to Bypass mode Kit Contents Power Unit (UPS) HPE R18000 DirectFlow 2U UPS unit; documentation; depth adjustable fixed rack mounting rails, mounting brackets; Front bezel I/O Modules HPE DirectFlow 2U I/O Module; documentation Environment-friendly Products and Approach End-of-life Management and Recycling Hewlett Packard Enterprise offers end-of-life Hewlett Packard Enterprise product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest Hewlett Packard Enterprise sales office. Products returned to Hewlett Packard Enterprise will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard Enterprise web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HEWLETT PACKARD ENTERPRISE OEM customers who integrate and re-sell Hewlett Packard Enterprise equipment. Page 19

Summary of Changes Date Version History Action Description of Change 23-Oct-2017 Version 5 Added Care Pack naming and Service and Support- Parts and Materials updated. 9-Sep-2016 From Version 3 to 4 Changed Technical Specifications section was revised. 11-Dec-2015 From Version 2 to 3 Changed Technical Specifications for eh HPE R12000 DirectFlow 1U UPS were revised. 09-Feb-2015 From Version 1 to 2 Changed Overview, Standard Features, Service and Support, Related Options, Maximum Output Power, Estimated Runtime (Minutes), and Technical Specifications sections were revised. Title was changed from DirectFlow Uninterruptible Power System to HPE DirectFlow Three Phase Uninterruptible Power System. Sign up for updates Copyright 2017 Hewlett Packard Enterprise Development LP. The information contained herein is subject to change without notice. The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein. c04376695-15068 - Worldwide - V5-23-October-2017 Page 20