PRODUCT SHEET. ! OXY-MRI is not intended for animal use.

Similar documents
PRODUCT SHEET. NON-INVASIVE SMALL ANIMAL TAIL BLOOD PRESSURE SYSTEMS NIBP250 Blood Pressure Amplifier NIBP200A Blood Pressure System

PRODUCT SHEET. 40HP Monaural Headphones OUT01E Foam Ear Inserts: LED

INTRODUCTION The Monitor, interchangeable modules and storage batteries are described below. Refer to the table below for specifications.

PRODUCT SHEET INTERFACE MODULES

BSL Hardware Guide for MP35 and MP30-1 -

Weight Height WxDxH Cuff Size. Housing Program Environmental Conditions

Tesla M3 MRI Patient Monitor

IX-228/S Data Acquisition Unit

Argentine Manufacturer of Hospital Equipment. Electrocardiograph Pulse Oximeters Vital Signs Monitors

Infusion Pumps. Website: Kizlon Medical

TRANQUILITY VS VERSATILITY IN VITAL SIGNS A M E R I C A S TRANQUILITY VS A M E R I C A S

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box

MD300 C5 Pediatric Oximeter

Continuous Noninvasive Blood Pressure for Human MRI Applications

DATA ACQUISITION USING THE BIOPAC DATA SYSTEM

POWERFUL - VERSATILE - INTUITIVE

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

Siemens BACnet Programmable TEC Unit Conditioner Controller

Vet BP. Vet30 VITAL SIGNS. Continuous Vital Signs Monitor for Companion Animals

TALON Network Manager- 2 & 6 Express

Model SC500. Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION FEATURES

medlab PEARL200 Technical Manual Pulse Oximeter OEM Board Copyright Medlab 2014 PEARL200 Pulse Oximeter OEM Module Technical Manual

MODEL SELECTION SINGLE-PHASE, TWO-WIRE (ONE-ELEMENT) MODELS WITH INTERNAL CURRENT SENSOR

EG medlab. Pulse Oximeter OEM Board. Technical Manual. Copyright Medlab. Version

Product Specifications

Stand-Alone, Low-Cost Data Loggers and Accessories. USB-500/600 Series Comparison Chart

Weighing Indicator. Features. Description. Applications

WI-130 WDAC User s Manual

iworx RA-834 Recorder

WebDAQ 316. Internet Enabled Thermocouple Logger. Remote Configuration and Monitoring. Virtually Unlimited Storage. Integrated HW and SW

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

Technical Note Series

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

TITLE PAGE I. Safety Information II. General Description III. Specifications IV. Controls V. Calibration Procedures VI. Measurement Preparation

analytical bulk flow distance FLOW level pressure temperature industrial communication

power quality Models 8230 & 8220

Service Manual. Vital Signs Monitor (52000 Series) Protocol QuikSigns (52000 Series)

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Tachometer Panel, PE3

Cardiostart. Biphasic Defibrillator Monitor

RT4F-120V/20A-WAC RECTIFIER

w w w. z i g s e n s e. c o m. a u

Chapter 1 MP Systems. 5

SINGLE-PHASE, TWO-WIRE (ONE ELEMENT) MODELS WITH INTERNAL CURRENT SENSOR

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

OPERATION MANUAL. Pen type, air oxygen and Temp. O2 METER. Model : PO2-250

Duo is a U.S. trademark of Mindray DS USA, Inc. Navigator is a U.S. trademark of Mindray DS USA, Inc.

INSTRUCTION MANUAL FOR GUARDIAN INFINITY SIM PROGRAM

Fully-Automated Multi-Function Electrical Safety Compliance Analyzers

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

HWS Series Wall Mount with Relay Setpoints, LCD, and Humidistat Control

etco 2 SpO 2 IBP medlab 2017/2018 OEM Modules for Patient Monitoring medizinische Diagnosegeräte GmbH

Slick Line Acquisition System Manual

EQUITY SERVICES & SOLUTIONS CO.,LTD. cono Flow

Propaq LT Monitors. Propaq LT Base Model. Propaq LT with Wireless Option/ Legendary quality and durability Heart rate, 3-or 5-lead ECG, SpO 2

RT4F-110V/25A RECTIFIER

RT12-240V/2.4kW Rectifier Specification

Quick Guide. NomaSense or O 2. USB cable. Temperature probe PT100. Short optical fiber

Student Quick Reference Guide

Siemens BACnet Programmable TEC Constant Volume

Siemens BACnet Programmable TEC Unit Vent Controller

Three-Phase Power Quality Analyzer PowerPad Model 3945-B

Meter Scanner & Controller

Biopac Student Lab 4.1 BSL PRO TUTORIAL. BIOPAC Systems, Inc. Windows 10, 8, 7 Mac OS X

BACnet Terminal Box (VAV) Controller

USB-500/600 Series Low-Cost Data Loggers and Accessories

CLEVELAND CONTROLS MODEL 6650 DIGITAL MANOMETER INSTRUCTION MANUAL DM

Sentinel Data Loggers

6224 Ethernet-Based Strain Measurement Module

THREE-PHASE POWER QUALITY ANALYZER

Andover ContinuumTM Infinet II

Pulse Oximetry Testing. Pulse Oximetry Testing. Coming Soon! Available 4th Qtr bcgroupintl.com. Features - FSX-1200 FSX-1200

medlab PEARL100 Pulse Oximeter OEM Board Technical Manual Copyright Medlab PEARL100 Pulse Oximeter OEM Module Data Sheet

SOUND LEVEL CALIBRATOR DVM1356 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1356 SOUND LEVEL CALIBRATOR 1

NL-01 NL-01. The NL-01 InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement.

AWA6223S Sound Level Calibrator. Instruction Manual HANGZHOU AIHUA INSTRUMENTS CO., LTD

BSL PRO 3.7 BSL PRO TUTORIAL. BIOPAC Systems, Inc. PC/Windows 98SE, Me, 2000 Pro, XP Mac OS X

CDD Carbon Dioxide Transmitter

RT4F-48V/50A-WAC RECTIFIER

7561-PSD Manual Portable Battery Powered Indicator

ADJUSTABLE SPEED DRIVES. QX7 Series. HVAC 18-Pulse. Phone: Fax: Web:

ZENSOL CIRCUIT BREAKER PERFORMANCE ANALYZER

#AS219 - Known Issues for AcqKnowledge

Wireless 0-1 ma Current Meter

2 Product Overview. 5 User Interface. 14 Logging Data. 17 Viewing Data. 19 Managing Data. 24 Device Settings. 26 Specifications.

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

Series TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel

PHASED OUT PRODUCT DC2. Microcontroller DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: June 1995

( F L O W I Z F A M I L Y )

INSTRUCTIONS. High Performance Electronic Components 9630 W. Irving Park Rd., Schiller Park, IL Phone (847) Fax (847)

NL-02 NL-02. The NL-02 InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement.

NannyCam V24. Instructions 1 For Use

DIGITMR S2 PC. digital circuit breaker analyzer. Vanguard Instruments Company, Inc.

icp 1000 Wireless GSM Based Remote Monitoring Unit for Transformer Rectifier Unit

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

T2214. Instruction Manual

FLOW MONITOR & TRANSMITTER

Transcription:

OXY-MRI SPO 2 MODULE WITH SENSOR FOR HUMAN MRI MRI Use: MR Conditional Condition: Must use MR finger sensor and max MR field strength 3T; module stays in control room. OXY-MRI is a stand-alone system for adult human pulse oximetry (SpO 2 ) in the MRI; it can also be used with a BIOPAC MP160/150 Research System. The system includes a SpO 2 amplifier and a fiber-optic oximetry sensor for the finger, plus a signal isolation adapter INISO and interface cables to connect to an existing BIOPAC HLT100C (high level transducer interface module) for MP Research Systems. Additional finger sensors are available as OXY-MRI-SENSOR. The SpO 2 amplifier is used in the MRI control room, the 9 m fiber-optic sensor cable is passed through the wave guide, and the finger sensor is attached to the subject in the MRI chamber room. MRI-rated to 3.0 Tesla.! OXY-MRI is not intended for animal use. SYSTEM COMPONENTS System includes: SpO 2 amplifier and pulse oximetry sensor for stand-alone use, plus INISO signal isolator and dsub9 cable to connect SpO 2 amp analog out to INISO for use with a BIOPAC Research System. Note: When simultaneously recording biopotential signals from a subject, or for safety in cases when the system is electrically connected to the subject (for recording or stimulation,) a BIOPAC HLT100C (not included) is required in order to connect the INISO to the MP160/150 unit. If more than one OXY-MRI signal is to be recorded using the HLT100C, an additional INISO can be obtained by contacting BIOPAC. (Only one INISO is included in the OXY-MRI system.) If not recording biopotential signals, the OXY-MRI cable can be connected directly to the UIM100C. BIOPAC Hardware OXY-MRI Page 1-5 Updated: 4.22.2016

SPECIFICATIONS Oxygen Saturation Display Range: 0 100% SpO 2 Pulse Rate Range: 18 321 BPM Saturation Accuracy (Arms): 70 100% ± 2 digits Note: ± 1 Arms represents approximately 68% of measurements Pulse Rate Accuracy: no motion 18 300 BPM ± 3 digits low perfusion 40 240 BPM ± 3 digits Displays: Pulse Strength: LED, Bar graph, tri-color segments Alarm Indicator: LED, bi-color Alarm Silenced: LED, amber Numeric Displays: 3-digit, 7-segment LEDs, green Low Battery: LED, amber Analog Outputs: SpO 2 Output Range: 0-1 VDC (0 100% SpO2), 1.27 VDC (out of track) Pulse Rate Output Range: 0-1 VDC (0 300 BPM), 1.27 VDC (out of track) Event Marker: 0 V (no event), 1 V (event occurred) Accuracy: ± 2% (SpO 2 ), ± 5% (Pulse Rate) Load Current: 2 ma maximum Memory: 70 hours (assuming continuous operation) Temperature Operating: 0 C to +40 C (32 F to 104 F) Storage/Transportation: -30 C to +50 C (-2 F to 122 F) Humidity Operating: 10 90% noncondensing Storage/Transportation: 10 95% noncondensing Altitude Operating: up to 12,000 meters (40,000 feet) Hyperbaric Pressure: up to 4 atmospheres Mains Power Requirements: 100 240 VAC 50 60 Hz Internal Power Requirements Battery: 7.2 volt NiMH battery pack Operating Life (fully charged battery): 16 hours minimum Storage Life: 21 days minimum Recharge Rate: 4 hours maximum Dimensions: Approximately 219 mm (8.6 ) W x 92 mm (3.6 ) H x 142 mm (5.6 ) D Weight: Approximately 900 grams (2 lbs) with battery Warranty: SpO 2 amplifier: 3 years; pulse oximetry sensor: 90 days Classification per IEC 60601-1/CSA601.1/UL60601-1: Type of Protection: Internally powered (on battery power) Degree of Protection: Type BF-Applied Part Mode of Operation: Continuous Enclosure Degree of Ingress Protection: IPX2 BIOPAC Hardware OXY-MRI Page 2-5 Updated: 4.22.2016

ACQKNOWLEDGE CALIBRATION (HLT100C) 1. Launch AcqKnowledge. The Add new module dialog should appear. If it does not, choose MP160/150 > Set Up Data Acquisition > Channels. 2. Choose HLT100C-A1 from the module list and choose Add. 3. Select OXY-MRI SPO2 Module Human-SPO2 from the Transducer list and click OK. 4. Follow the OXY-MRI SPO2 calibration and sensor prompts in order of appearance. (AcqKnowledge 4.4.2 and higher only.) 5. Choose Add new module and choose HLT100C-A2 from the module list and click Add. BIOPAC Hardware OXY-MRI Page 3-5 Updated: 4.22.2016

6. Select "OXY-MRI SPO2 Module Human-Pulse Rate" from the Transducer and click OK. 7. Follow the OXY-MRI Pulse Rate calibration and sensor prompts in order of appearance. (AcqKnowledge 4.4.2 and higher only.) If the sensors are not properly connected, the following dialog will appear. Check the connections and click Retry. BIOPAC Hardware OXY-MRI Page 4-5 Updated: 4.22.2016

ACQKNOWLEDGE CALIBRATION (UIM100C) 1. Launch AcqKnowledge. The Add new module dialog should appear. If it does not, choose MP160/150 > Set Up Data Acquisition > Channels. 2. Choose UIM100C-A1 from the module list and choose Add. 3. Choose Custom from the Transducer list and click OK to open the Scaling dialog. 4. Enter Cal 1, Cal 2, and Units Label as shown below and click OK. 5. Choose Add new module and choose UIM100C-A2 from the module list, and click Add. 6. Choose Custom from the Transducer list and click OK to open the Scaling dialog. 7. Enter Cal 1, Cal 2, and Units Label as shown below and click OK. BIOPAC Hardware OXY-MRI Page 5-5 Updated: 4.22.2016