the Centric 300 An advanced modular UPS up to 1800kVA/kW

Similar documents
GAMATRONIC, A SolarEdge Division.

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

MODULAR UPS SYSTEM KVA

THOR Modular. Modular UPS system. Online double-conversion Scalable Decentralized Parallel. Modular. 10, 20, 30, 40kVA modules kVA systems

LEVELUPS T3 3 UPS. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability with Embedded Isolation Transformer

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

MP7. Uninterruptible Power Supply

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups

DPA UPSCALE TM RI kw Technical Specifications

The Power of Modularity

Modular three-phase UPS system. Conceptpower DPA kva True modular UPS system for critical applications

PowerWAVE 9250DPA. ( N+1 kva/kw) Parallelable up to 1.5 MVA/MW

TME Modular Series UPS System kva/kw - 208/220 VAC

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 100kW 3MW

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Product brochure. Conceptpower DPA Modular UPS DPA 120 UL 208V: 20kW 600kW

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 20kW 600kW

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

Est FlexiPower Maxi UPS FPX Maxi kVA

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

Tel: AC Power for Business-Critical Continuity TM

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

SMARTONLINE E3 UPS SYSTEMS

Galaxy VX. From 500 kw to1500 kw N+1 Parallel solutions up to 4000 kw 480 V. schneider-electric.com

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

Conceptpower DPA TM S kva Technical Specifications

UPS TRIFASE kVA Rev. 8 Serie TPH IGBT

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

Symmetra PX. Symmetra PX 48kW Scalable from 16kW to 48kW. Modular, Scalable, High-Efficiency Power Protection for Data Centers

AIS 3000 APC AIS kVA 400V w/3 Batt. Modules Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA)

MGE Galaxy /900 kva

Power+ Family Products. P+ Family Products: Seth Davis- Global Marketing Manager

Modular UPS S KVA

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Est ComPower Mini. Compact UPS kva

MUST 900 UPS. Finally the benefits of Modular ups are for all. 3 Phase Modular. Hot swappable, scalable 30kVA to 900kVA

Eaton 9EHD Industrial UPS

Est FlexiPower Ultra UPS FPX Ultra kVA

Modular, scalable, high-efficiency power protection for data centers

Critical Power 2017 Catalogue

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

MGE Galaxy /300/400/500 kva Power efficiency for business continuity. schneider-electric.com

SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules

PHASE ONE Series 700: Uninterruptible Power Supply (UPS) Systems

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

ALL PRODUCTS UNINTERRUPTIBLE POWER SYSTEMS

Business continuity made easy

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application

Liebert NX - Next Generation UPS for protecting your Business Critical Systems. AC Power Systems for Business-Critical Continuity

ELEKTRA SMALL FOOT PRINT SERIES. Mission Critical & I.T Grade UPS I.T GRADE ONLINE DOUBLE CONVERSION UPS 10KVA ~ 200KVA (3/3)

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

Intelligent On-Line UPS

CPS kVA TRIFASE EN50171

SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module

The quality management system is. Mitsubishi Electric Corporation Kobe Works has been approved to ISO9001:2000.

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments

Schneider Electric Easy UPS 3S

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

Eaton 9EHD Industrial UPS

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

ZP120N Online UPS. High Power Intensity. Flexibility. High efficiency with low heat dissipation. Smart Energy Solutions

Galaxy VM. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Chloride. FP-60z 5 160kVA 1ph / 3ph Industrial AC UPS System

MAJOR VA Power Inverter

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications

SR Plus series. on-line. SR20 Plus SR20T Plus. SR60 Plus LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS. Industrial PLCS

UPS5000-E (25-75 kva) Series

7011A Series Single-Phase

RT12-240V/2.4kW Rectifier Specification

A. Advanced Features. Configurable High Power Solution

LP 33 Series UPS. Digital Energy. GE Digital Energy

Huawei Energy Powering the Future. Huawei UPS Solutions. Huawei Energy Powering the Future HUAWEI TECHNOLOGIES CO., LTD.

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

ATV1200A kv kva

ATV1200A kv kva

SmartOnline 230V 2kVA 1800W On-Line Double- Conversion UPS, Tower, Extended Run, Network Card Options, LCD, USB, DB9

PowerWAVE 9500DPA. ( kva/kw) Parallelable up to 3 MVA/MW

HYBRID PV INVERTERS HySpirit Series. 4kW-10kW. Hybrid Inverter with Battery Backup Smart Energy for Smart Home

Est FlexiPower Maxi. Modular UPS kw

Liebert NX Series. 30kVA to 200kVA. AC Power for Business-Critical Continuity TM

Conceptpower DPA TM Technical Specifications

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva

MGE Galaxy /30/40/60/80/100/120 kva. The recommended power protection for all critical applications.

Inverter W and 12500W

Zero downtime for mission critical applications? Absolutely.

Schneider Electric Easy UPS 3S

Liebert NXr Series 15KVA to 90KVA (208V/220V) AC Power for Business-Critical Continuity

Single phase UPS. Applications. Highlights. 1ph from 450 VA to 10 kva. Home Office Computers and peripherals Networks and servers Small data centers

VIDI System Controller

The 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN.

Transcription:

the Centric 300 An advanced modular UPS up to 1800kVA/kW 1

Gamatronic, Israel s Leading Power Electronics Company True to the exceptional reputation earned by Israeli technology companies, Gamatronic has been leading the power management industry for more than 4 decades. Establishing its presence globally, Gamatronic exports worldwide thanks to its expertise and certification in the diverse power needs across the continents. High standards and strong emphasis on R&D, together with technological innovation and comprehensive product understanding, are among the many reasons why the most power demanding industries including healthcare, IT, defense, transportation, telecom to name a few, rely on Gamatronic technology. All products are tested in our factory in Jerusalem, allowing full quality control at all times and are manufactured in accordance with CE and ISO 9001 certification. Due to the growing needs of the market, Gamatronic launched the Centric 300, its reliability, flexibility, intelligent features and design make it a great choice for your data center. Our power is your confidence. 2

Introducing the Centric 300 Modular UPS The Centric 300 provides power protection and power backup for loads from 300kVA to 1800kVA. The Centric s double-conversion transformerless topology provides high quality power regulation in accordance with IEC 62040 VFI-SS-111 and AC/AC efficiency up to 96.5%. The Centric battery is true online as per IEC 62040 guaranteeing instant availability of backup power in the event of mains failure and provides high unique DC/AC efficiency of over 98%. The Centric provides reliable, clean, regulated AC power at an attractive price and is available in 10 configurations, (30, 60, 90, 120, 150, 180, 210, 240, 270, 300 kw). Positive battery + - Rectifier Inverter L1 L2 L3 N N N L1 L2 L3 N + - Negative battery The Centric 300 s reliability, flexibility, intelligent features and design make it a great choice for your application. 3

Centric 300 Features: True online battery Up to 96.5% efficiency High power density Small footprint Lightweight 19 design Advanced colorful LCD touch screen Support variant battery types (VRLA, Li-ion, etc.) Support ultra capacitors* Self -loading* Built-in oscilloscope SCALABLE: Static switch:»» Hot swappable»» High short circuit clearance»» Optional internal backfeed protection»» Mimics centralized performance when paralleled Up to 99% efficiency using METS** Internal maintenance bypass switch Maintenance-friendly power modules Seismic brackets Centralized and decentralized battery The Centric 300 is designed to grow as your power requirements increase. Its output capacity is easily scalable on-site by adding a hot plug-in 30kW module. The Centric is vertically scalable, with 1 to 10 UPS modules of 30kW each, providing from 30kW to 300kW. The Centric is horizontally scalable with up to 6 units providing up to 1800kW of power. MODULAR: Centric 300 is a modular, parallel and redundant UPS featuring double conversion architecture. The system is composed of up to ten UPS modules, a system controller and a static switch module. The Centric s vertical and horizontal modularity reduce the downtime thus providing a fault tolerant power source to critical loads and applications. Front View 202 cm Future unit Future unit 4 * Will be available in 2018 ** METS Mode (Maximum Efficiency Tracking System) 360 cm

Centric Efficiency The Centric 300 is an extremely economical UPS system, achieving high efficiency versus load and is an ideal UPS for Tier 3 and 4 data centers with a low load. The Centric 300 can achieve up to 96.5% efficiency at typical data center load levels. 25% LOAD 2 x 300kW 2N+1 (Tier 4) Application 100% IT LOAD 25% LOAD 2 x 300kW Efficiency (%) REDUNDANCY 97 N+0 N+1 N+2 N+3 N+4 N+5 N+6 N+7 N+8 N+9 96.5 96 95.5 95 94.5 94 93.5 0 20 40 60 80 100 Power 300 270 240 210 180 150 120 90 60 30 270 240 210 180 150 120 90 60 30 240 210 180 150 120 90 60 30 210 180 150 120 90 60 30 180 150 120 90 60 30 150 120 90 60 30 120 90 60 30 90 60 30 60 30 30 Load (%) 5

Power Density The capacity of data centers today are expanding to embrace the increased IT load by increasing the data center density with the same footprint. Centric 300 s high power density enables you to save valuable space and supports your increasing IT load density. 78.2 in (198.5 cm) FOOTPRINT: The Centric 300 s footprint is less than 6½ ft 2 (0.6m 2 ). Power Footprint = 50w / cm 2 Power Density = 0.25w / cm 3 Choose the Centric 300 to significantly increase your UPS capacity with minimal floor space. 39.37 in (100 cm) 23.62 in (60 cm) 78.2 in (198.5 cm) 39.37 in (100 cm) 6 23.62 in (60 cm) 7.87 in (20 cm) 7.87 in (20 cm) 23.62 in (60 cm) 23.62 in (60 cm)

The Centric 300 system controller enhances data center management systems with its unique abilities: Built-in flexible connectivity Intuitive and intelligent graphic user interface Fail-safe (non-critical for UPS operation) Hot swappable Configurable 8 input and 8 output dry contacts Embedded web interface SNMP RS 232 SEC MODBUS RS485 and over TCP-IP Unlimited servers shutdown Unlimited email notifications Multi-language interface Generator mode Data-rich system log 7

Static Switch and Maintenance Bypass The static switch is a hot swappable module that is not needed for double-conversion mode. Static Switch Rectifier Inverter Main Output Battery 8

Solutions Vertical and Horizontal with Decentralized or Centralized Battery Full Power 600kW Full Power 900kW Full Power 1200kW Full Power 1500kW Full Power 1800kW Up to 270kW Vertical & Horizontal Up to 300kW Horizontal Up to 540kW Vertical & Horizontal Up to 540kW Vertical Up to 600kW Horizontal Up to 810kW Vertical & Horizontal Up to 810kW Vertical Up to 900kW Horizontal Up to 1080kW Vertical & Horizontal Up to 1080kW Vertical Up to 1200kW Horizontal Up to 1350kW Vertical & Horizontal Up to 1350kW Vertical Up to 1500kW Horizontal Up to 1620kW Vertical 9

CENTRIC 300 UPS SYSTEM SPECIFICATIONS Topology Modular, double-conversion, VFI, on-line battery Operation Continuous hot swappable Input Voltage (V) 3x400 (4 wires + Gnd) Voltage range (%) -20 / +15 Voltage range (Vac) 200 ~ 460; 200 ~ 360, with derating Current (A) 3 46 per module no inrush current at startup Rectifier frequency (Hz) 40 ~ 70 Power walk-in (sec) >60 Power factor correction >0.99 THDI (%) <3 Inrush current None Bypass voltage tolerance (%) ±10, ±15 (when synchronized; user selectable) Output Rated Power (kva/kw) 30 ~ 1800 Nominal frequency (Hz) 50/60 Frequency tracking range (Hz) ±(0.5, 1, 2, 3, 4), selectable Frequency tracking slew rate (Hz/sec) 1 Frequency (in free-running mode) (Hz) 50/60 ±0.1 % Nominal voltage (Vac) 3x380, 3x400, 3x415 (3 or 4 wires + Gnd) Static voltage regulation (%) ±1 Regulation for 100 % unbalanced load (%) ±1 Dynamic response to 100 % load step (%) ±2 Overload withstand Inverter mode 110 % : 10 min, 125 % : 60 s, 150 % : 30 s Bypass mode 125 % : 10 min, 1000 % : 1 cycle THD (%) Linear load: <1; non-linear load: <6 Load CF (max) 6:1 Power factor 1, up to +/-0.7 for reactive loads Ac-Ac efficiency (%) up to 96.5 Batteries Dc-link voltage (Vdc) 320 ~ 405 (405 floating, accuracy to ±1 %) Quantity 60 12 Vdc Type Sealed, lead-acid. Lithium-ion General Maximum power dissipation (Po=25 kw) N*1250 W (N*4265.2 BTU/h), where N = # modules Ambient temperature ( C) -10 to +40 (operating), -20 to +60 (storage) Relative humidity (%) 95 maximum, non-condensing Altitude (m) 1500 without derating Enclosure IP20 Cooling system Multi-fan with speed control (forced air) Design & manufacturing standards Safety IEC 62040-1 EMC IEC 62040-2 Design classification IEC 62040-3 Dimensions # of power modules 1 2 3 4 5 6 7 8 9 10 Power output (kw/kva) 30 60 90 120 150 180 210 240 270 300 Height, width, depth (mm) W=600, H=2015 (w/o wheels), D=1000 Weight (kg) w/o batt. box 230 250 270 290 310 330 350 370 390 410 Weight 1 module (kg) 20 All specifications are subject to change without advance notice. 10

CENTRIC 300: TECHNICAL SPECIFICATIONS FOR THE SYSTEM CONTROLLER Display LCD flat panel, touch-sensitive Other indicators Audible alarm Analog input channels 8 input dry contacts (N.O. / N.C.) Real-time clock (RTC) Yes, with backup Power meter kva, kw, PF Volt-free outputs (dry contacts) 8 outputs, rated 48 V / 1 A Ac failure Dc failure UPS module(s) failure Load on bypass Output dry contacts Battery test failure Over/under temperature Overload (Each system alarm type can be routed to the dry contact of your choice.) Communication ports Serial, Ethernet, USB Communication protocols RS232, RS485, TCP/IP, SNMP, Modbus Communications with system modules Serial, isolated Events log 2000 events System operation without controller Unchanged Load bar-graph 3-phase voltages 3-phase currents On-screen parameters Battery voltage Status of each UPS module Static-switch parameters and status Battery sensor temperature RTC operation without power Indefinitely All specifications are subject to change without advance notice. 11

Gamatronic strives to provide reliable and flexible power solutions to ensure optimal efficiency, empowering your business to help you achieve your goals. Our Power, Your Confidence www.gamatronic.com 12 0118