Instruction Manual LeCroy PP007-WR / PP007-WS Passive Probe

Similar documents
LeCroy PP009 Passive Probe Instruction Manual

LeCroy PP008 Passive Probe Instruction Manual

PP007-WR-1 PP007-WR-2 PP007-WS-1 PP007-WS-2. Operator s Manual. PP007 Passive Probe

PMT 201A-RO High Impedance Passive Probe. Instruction Manual

38 MHz Passive Voltage Probe R&S RT-ZP1X

PMT 221A High Impedance Passive Probe. Instruction Manual

designed for OMICRON Lab PML 111O High Impedance Passive Probe Instruction Manual

PML 791-RO Low-Z Passive Probe. Instruction Manual

TA MHz Oscilloscope Probe USER S GUIDE

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Instructions. P MHz 10X Passive Probe

N2870A Series Passive Probes and Accessories

N2870A Series Passive Probes and Accessories

Keysight N2870A Series Passive Probes and Accessories. Data Sheet

TETRIS 1000 / High Impedance Active Probe Order-No: Features:

Instructions. P GHz 10X Active Probe

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL

User s Guide. RP7000S Series Single-Ended Active Probe. Nov RIGOL Technologies, Inc.

KHT 6000 C HV-Probe Calibrator. Instruction Manual

Accessory GP-EXT. EXTERNAL USB PRINTER User's Manual

User's Guide. Extech AM A AC Analog Clamp Meter

P5200A Series High Voltage Differential Probes. Installation and Safety Instructions & Product Documentation CD

HV-CS kv Edge Mount Triaxial Jack

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

Model 2380 Rack-Mount Kit

TCP305A & TCP312A AC/DC Current Probes Instructions

Mini Digital Multimeter

VDS Series PC Oscilloscopes Quick Guide

User s Guide. 600A AC Clamp Meter. Model 38387

PCM-7140 Pulsed Current Source Operation Manual

9040/9040UK. Users Manual. Phase Rotation Indicator

Instruction Manual LeCroy CP150 Current Probe

Keysight 42941A Impedance Probe Kit

User's Guide. Phase Sequence and Motor Rotation Tester Model

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1

DS1000B Series Digital Oscilloscope

Line Impedance Stabilization Network (LISN)

2019 RIGOL (SUZHOU) TECHNOLOGIES INC.

OPERATION MANUAL SERIES BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

Visit us at

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

OPERATION MANUAL SERIES MICRO BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

Quick Start/Installation Guide

User s Guide Tenma USB PC Based Digital Oscilloscope Operation Manual

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

User's Guide. MiniTec TM Series Model MN25 MultiMeter

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

2016 SIGLENT TECHNOLOGIES CO.,LTD

200B-G Tone Probe. 200EP-G Tone Probe INSTRUCTION MANUAL. with Adjustable Volume

NX8 Pocket Toner Users Guide

DM3058/DM3058E Digital Multimeter

EA003 OPTICAL TACHOMETER CALIBRATION ADAPTER OPERATION MANUAL

Instruction Manual. ZD Series Differential Probes (ZD500, ZD1000, ZD1500)

RZ2 BioAmp Processor. Operator s Manual

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

DCS200/DCS200-09/DCS DCS300/DCS300-09/DCS355

50 Amp AC/DC Current Probe PA-655 INSTRUCTION MANUAL 安培交流 / 直流電流探測鉗. DC 500KHz. 5mA 50A.

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

TSD-DA28 2x8 Balanced Line Distribution Amplifier

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

DC 100 A Current Probe

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

Fiber Optic Prism Switch USER S MANUAL

PIM-Mini Pulsed Current Source Operation Manual

Model 7705 Control Module

User's Guide. Model High Precision Quad Output DC Power Supply

PicoScope 9000 Series PC Sampling Oscilloscopes. Quick Start Guide

Model 2380 Rack-Mount Kit

ETHOS Auto Ranging Digital Multimeter

DC 100 A Current Probe

SmartBoom PRO PHS-SB100-4F, PHS-SB100-5M, PHS-SB100-U, PHS-SB200-4F, PHS-SB200-5M, PHS-SB200-U. Operating Manual

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

MTP INSTRUCTION MANUAL

OX 5022-CK OX 5042-CK

Model GHz 50 Ohm RF Module

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

7032 Digital-Analog Multimeter

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

Model 7701 Multiplexer Module

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

Variable-Speed Vortex Mixer

1. Safety Precautions (Read these precautions before use.)

MulTI-Touch Projected Capacitive Touch Screen Integration Guide

ENGLISH. User manual.

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable

Autoranging Mini Multimeter Model MN16A

AC/DC Current Probe Model SL206 USER MANUAL

NX1 Pocket Toner Users Guide

Conductive Level Controller

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Mini Digital Multimeter

Model 2657A-LIM-3 LO Interconnect Module

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging

Transcription:

PP007-WR-1 PP007-WR-2 PP007-WS-1 PP007-WS-2 Instruction Manual LeCroy PP007-WR / PP007-WS Passive Probe Revision D July 2004

Warranty LeCroy warrants this oscilloscope accessory for normal use and operation within specification for a period of one year from the date of shipment. Spare parts, replacement parts and repairs are warranted for 90 days. In exercising its warranty, LeCroy, at its option, will either repair or replace any assembly returned within the warranty period to the Customer Service Department of an authorized service center. However, this will be done only if the product is determined by LeCroy s examination to be defective do to workmanship or materials, and the defect is not caused by misuse, neglect, accident, abnormal conditions of operation, or damaged resulting from attempted repair or modifications by a non-authorized service facility. The customer will be responsible for the transportation and insurance charges for the return of products to the service facility. LeCroy will return all products under warranty with transportation charges prepaid. This warranty replaces all other warranties, expressed or implied, including but not limited to any implied warranty of merchantability, fitness or adequacy for any particular purposes or use. LeCroy shall not be liable for any special, incidental, or consequential damages, whether in contract or otherwise. Corporate Headquarters 700 Chestnut Ridge Road Chestnut Ridge, NY 10977-6499 Tel: (845) 425-2000 Fax: (845) 425-8967 Internet: www.lecroy.com Copyright 2003, LeCroy Corporation. All rights reserved. Contents of the publication may not be reproduced in any form without permission of LeCroy Corporation. LeCroy, Easywave, SMART Trigger and ProBus are registered trademarks of LeCroy Corporation. LeCroy products are covered by International and U.S. patents, issued and pending. PK007-OM-E Rev D 07/04 2

Safety Information This symbol appears on the product:! This refers you to additional information contained in this manual. The corresponding information in the manual is similarly denoted. To avoid personal injury and to prevent fire or damage to the probe or any products connected to it, review and comply with the following safety precautions. Connect to properly grounded instruments. This probe is to be only used with test instruments with input connectors which the BNC shield (ring) is connected to earth ground. Connect the probe properly: Connect the probe to the measurement instrument before connecting probe input to test circuit. Do not disconnect probe from test instrument while the input is connected to test circuit. Do not connect the probe ground terminal to any point in the test circuit which is at a potential other than earth ground. Do not apply any potential to the input which exceeds the maximum ratings of the probe. Comply with the voltage derating curve. When measuring high frequency signals, be sure to comply with the voltage versus frequency derating curve found on page 8. Do not use in wet or explosive atmospheres. For indoor use only. This probe is intended for indoor use and should be operated in a clean, dry, environment. Do not use the probe if any part is damaged. All maintenance should be referred to qualified service personnel. Avoid physical injury. The probe tip is extremely sharp. Use care when handling to prevent injury, including accidental skin puncture. Use of the probe and or the test instrument it is connected to in a manner not specified by the manufacturer may impair the protection mechanisms. 3

Introduction The PP007-xx is a miniature high impedance passive probe. Its high input resistance and low capacitance make it ideal from general purpose probing of signals with frequency content from DC through several hundred MHz. The PP007 has a large selection of connection accessories, both supplied standard with the probe and available from LeCroy as optional accessories. The PP007-xx is available in two models, differing only in the design of the compensation network. The PP007-WR is designed for use with LeCroy WaveRunner 6000 series oscilloscopes. The PP007-WS is designed for use with LeCroy WaveSurfer 400 series oscilloscopes. All of the standard and optional accessories are interchangeable between all models Specifications! Electrical Characteristics Attenuation 10 ±1% Input Resistance 10 MΩ ±1% Input Capacitance 9.5 pf Input Impedance (see plot on page 5.) Compensation Range Bandwidth Maximum Input Voltage Electrical Ratings Pollution Degree 2 10 20 pf 500 MHz (-3 db) Measurement category I: 400 V rms, 1250 V transient overvoltage (see voltage derating curve on page 5) Measurement category II: 300 V rms CAT II Measurement category I is for measurement performed on circuits not directly connected to a mains supply. Measurement category II (CAT II) is for measurement performed on circuits directly connected to a low voltage installation. This refers to local distribution level, applicable to equipment connected to the mains (AC power source) through a power cable. Pollution Degree 2 refers to an operating environment where normally only dry non-conductive pollution occurs. Occasionally a temporary conductivity caused by condensation must be expected. 4

Specifications (continued) V IN (Vrms) 400 350 300 250 200 150 100 50 0 100 K Certifications Operating Temperature Storage Temperature Altitude, Operating Cable Length Weight (probe only) Max. V IN versus Frequency, Measurement category I 1 M General Characteristics 0 o to +50 o C -40 o to +71 o C up to 2000 m (6560 ft) 1.3 m 42 g Z IN (Ω) 10 M 1 M 100 k 10 k 1 k 100 Typical Input Impedance 10 10 M 100 M 1 k 1 M 100 M Frequency (Hz) Frequency (Hz) This probe is designed to conform to 73/23/EEC + amendment 93/68/EEC Low Voltage Directive (LVD) per the following standards: CEI/IEC 61010-031:2002-01 Safety requirements for electrical equipment for measurement control and laboratory use: Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test. 5

Connectivity Accessories LeCroy provides over 30 individual accessories for the PP007-xx probe, which enable reliable connections to any physical requirement. In addition to those provided with the standard probe, several optional varieties are available either individually, or grouped in sets related to specific application needs. The PK007 series of connectivity accessories are compatible with any LeCroy 2.5 mm PP0x7 series probe. Accessories are shown with the LeCroy part number followed by the description. Standard Accessories 1 2 3 PK007-001 PK007-002 PK007-003 Sprung Hook Standard Ground Lead Adjustment Tool 4 5 6 7, 8, 9, 10, 11 PK007-004 Rigid Tip, 0.5 mm PK007-007 PK007-008 IC Cap, 0.5 mm pitch, (green) PK007-005 Spring Tip, 0.5 mm Insulating Cap PK007-008 IC Cap, 0.65 mm pitch, (blue) PK007-010 IC Cap, 0.8 mm pitch, (gray) PK007-011 IC Cap, 1.0 mm pitch, (brown) PK007-012 IC Cap, 1.27 mm pitch, (black) 6

Standard Accessories (continued) 12 13 14 15 PK007-006 PL007-013 PK007-016 PK007-014 Color Coding Rings (set) Ground Blade Ground Spring Copper Pad 16 (Not shown) PK007-015 PP007-OM-E PCB Adapter Instruction Manual Use of PCB Adapter The PCB adapter (LeCroy P/N PK007-015) is intended to be designed into and permanently installed in circuit boards to provide a reliable, high frequency test point which eliminates the need to hand hold the probe. 5.8 mm (0.200 ) 1.5 mm (0.059 ) 1.0 mm x 4 (0.039 ) Probe connected using PCB Adapter PC Board hole size and pattern 7

Optional Accessories Input Adapters and Clips 17 18 19 20 PK007-017 PK007-018 PK007-022 PK007-023 Single Lead Adapter Dual Lead Adapter Adapter, 2 mm plug Adapter, 4 mm plug 21 22 23 PK007-019 PK007-020 PK007-021 Pico Hook Micro Clip, Long Micro Clip, Short 24 PK007-031 BNC Adapter (For low voltage use only 42 V pk AC + DC) 8

Ground Leads 25 26 PK007-024 PK007-025 Probe Tip Ground Lead w 0.8 mm Socket Probe Tip Ground Lead with Alligator Clip 28 29 30 PK007-026 PK007-027 PK007-028 Ground Llead with mini clip Ground Lead with 8 mm socket Ground Lead with 2 mm plug 31 32* PK007-029 PK007-030 Ground lead with 4 mm plug High Frequency Compensated Ground Lead *The PK007-030 High Frequency compenated ground lead allows operation with long ground lead wiith minimum signal distortion. 9

Probe Connectivity Kits The following kits containing an assortment of probe connection accessories can be ordered directly from LeCroy. Refer to the illustrations on pages 6-9 for identification. PK701 Basic Adapter Kit replaces the common standard accessories, with 2 each of designators 1, 2, 4, 5 and 14; plus one adjustment tool (designator 3). PK702 Advanced Adapter Kit contains a large assortment of accessories: 1 each of the designators 1, 2, 3, 5, 7, 8, 9, 10, 11, 13, 14, 15, 18, 21, 25, 29, 32; 2 each of designators 4, 12, 22, 23, 24; and 5 each PCB adapter 16. PK703 SMD Adapter Kit contains an assortment useful for attaching to surface mounted ICs and components: 1 each of designators 14, 17, 18, 22, 23, 25, 28, 29, 32; and 2 each of designators 5, 6, 7, 8, 9, 10, 11, 13, 15. PK704 Micro Clip Kit adapts the probe for use with 0.5 mm IC lead clips. It contains 1 each of designators 16, 17, 18; and two of each micro clip, designators 22 and 23. Use and Maintenance This probe is a high quality, precision instrument. To maintain accuracy and signal fidelity, mechanical shock should be avoided, as well as damage to the cable through excessive bending. To achieve the small 2.5 mm tip size, the input tip diameter is narrower than those in larger probes. Avoid placing excessive force sideways on the tip. Should the tip become damaged, it may be replaced by the user using the procedure listed on the last page. Other maintenance and component replacement should be referred to qualified personnel. Cleaning The outside of the probe should cleaned with a soft cloth dampened with either deionized / distilled water or isopropyl alcohol. Allow the surface to dry completely before returning the probe to service. Never immerse the probe in any liquid. 10

Probe Compensation Proper compensation of the probe is required to assure good amplitude accuracy in the dynamic portions of the waveform being measured. LF compensation matches the probe to differences in oscilloscope input capacitance. The LF compensation should always be checked and adjusted as needed when first connecting a passive probe to the oscilloscope input. HF compensation matches time constants within the probe to compensate for normal component tolerances. It is typically not necessary to adjust HF compensation unless the probe is being used with an oscilloscope with large differences in input characteristics than the oscilloscope model it was designed for. LF compensation is performed by connecting the input of the probe to a low frequency square wave, such as the oscilloscope calibrator signal set to 1 khz. The compensation is adjusted by rotating the adjustment accessible through the small hole in the center of the housing near the BNC connector. Use the tool supplied with the probe for this adjustment. Undershoot Overshoot Correct adjustment Should HF compensation be required, access the adjustments by sliding the black plastic cover off the compensation housing near the BNC connector. A pulse generator with low overshoot and a 300 ps risetime is the required signal source, along with a set of attenuators. The probe must be connected to a terminated probe tip to BNC adapter. Some overshoot and ring will be present at some settings of V/Div. Adjust both trimmers for the overall best response on all ranges. Typical optimum HF adjustment 11

Tip Selection and Exchange The PP007-xx probe is supplied with two tip styles. The spring tip, which is installed when the probe is shipped, combines a sharp point with on-axis compliance. This provides reliable connection under a wide range of physical interconnect situtations. A rigid tip is also supplied. While lacking the on-axis compliance feature of the spring tip, the rigid tip has a larger diameter and is more robust when exposed to physical stress at the tip. The user should select the proper tip for their application needs. To change the or replace it when damaged, carefully grip the outer most portion of tip and pull straight out, along the axis of the probe, using needle nose pliers. Do not attempt to grip the plastic insulator with pliers when removing the tip, as this will squeeze the tip, which will make it difficult or impossible to remove. Do not grip the outer gold plated tube which the tip slides into. With the tip removed, align the replacement tip with the hole and begin the insertion with the pliers. The tip may be fully seated by placing the probe against a hard surface and gently applying pressure. To remove tip, grip the spring-loaded portion of the tip, beyond the outer sleeve, and pull straight out. Do not apply pliers to the plastic insulator. 12