Simulation Based POD Estimation for Radiographic Testing of Turbine Blades

Similar documents
Reliability Investigations of Radiographic Testing Using artist as a Simulation Tool

Radiographic Simulator artist: Version 2

Combining Analytical and Monte Carlo Modelling for Industrial Radiology

Simulation of Radiographic Testing for POD Assessment

CIVA Computed Tomography Modeling

EVALUATING PERFORMANCE CHARACTERISTICS OF X-RAY EQUIPMENT AND FILM SYSTEMS WITHOUT THE USE OF ELECTRONIC MEASUREMENT AND/OR SPECIAL INSTRUMENTS

Mr. Chaobin Li China Lucky Film Corp. No. 6 Lekai South Street 6, Baoding, Hebei Province, PRC Tel.:

COMPUTER SIMULATION OF X-RA Y NDE PROCESS COUPLED

Fracture Mechanics and Nondestructive Evaluation Modeling to Support Rapid Qualification of Additively Manufactured Parts

Pipe Inspection with Digital Radiography

Investigation of the film AGFA D4 in TETENAL machine processing

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system

PICASSO improved reliability inspection of Aeronautic structure through Simulation Supported POD

Coordinate Measuring Machines with Computed Tomography

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL

STATUS 5. A Reliability Assessment Tool For NDT Inspection Systems

Modelling I SPECIFIC REQUIREMENTS ON COMPUTER MODELING OF RADIOGRAPHIC INSPECTIONS OF NUCLEAR COMPONENTS

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

Industrial Computed Tomography Innovations

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS

Quality control phantoms and protocol for a tomography system

Reconstruction Methods for Coplanar Translational Laminography Applications

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications

Supercomputing the Cascade Processes of Radiation Transport

Laminographic Inspection of Large Carbon Fibre Composite Aircraft-Structures at Airbus

Automatic Ultrasonic testing for Metal Deposition

Evaluating RT systems with a new POD approach

Industrial Radiography Simulation by MCNPX for Pipeline Corrosion Detection

EMULATION OF POD CURVES FROM SYNTHETIC DATA OF PHASED ARRAY ULTRASOUND TESTING

ASSESSMENT OF MEASUREMENT UNCERTAINTY CAUSED IN THE PREPARATION OF MEASUREMENTS USING COMPUTED TOMOGRAPHY

Dr. Javier Santillan, San Carlos, CA

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China

Industrial Computer Tomography for Dimensional Metrology: Overview of Influence Factors and Improvement Strategies

Shielding factors for traditional safety glasses

Precise laser-based optical 3D measurement of welding seams under water

UMASIS, AN ANALYSIS AND VISUALIZATION TOOL FOR DEVELOPING AND OPTIMIZING ULTRASONIC INSPECTION TECHNIQUES

Radiographic Modelling for NDE of Subsea Pipelines

INFLUENCE OF GEOMETRICAL MAGNIFICATION ON COMPUTED TOMOGRAPHY DIMENSIONAL MEASUREMENTS

Simulation Supported POD Methodology and Validation for Automated Eddy Current Procedures

Vajira Jayasinghe, Chris Eaton, & Brian Millejours. Application of Flexible PAUT probes for small diameter FAC elbow inspection II

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Advanced Reconstruction Techniques Applied to an On-Site CT System

Calypso the Easy Way to Create Part Programs

Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator

Optimized Design of 3D Laser Triangulation Systems

X-ray simulation and applications

Lorad FFDM QC Procedures for Medical Physicist. Tao Wu, Ph.D. Hologic, Inc.

VALIDATION OF THE SIMULATION SOFTWARE CIVA UT IN SEPARATED TRANSMIT/RECEIVE CONFIGURATIONS

Forward Time-of-Flight Geometry for CLAS12

Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct

SAFT-Reconstruction in ultrasonic immersion technique using phased array transducers

Model-Based POD Studies. Objective: Develop a list of model-based POD studies that have been completed to date

Digital Scatter Removal in Mammography to enable Patient Dose Reduction

DUE to beam polychromacity in CT and the energy dependence

RT Modelling for NDT Recent and Future Developments in the CIVA RT/CT Module

High-resolution X-ray CT Inspection of Honeycomb Composites Using Planar Computed Tomography Technology

BME I5000: Biomedical Imaging

Use of Monte-Carlo Methods to Derive Quantitative Probability of Defect Detection Data

Analysis of Combined Probing Measurement Error and Length Measurement Error Test for Acceptance Testing in Dimensional Computed Tomography

New developments in industrial radiography at EDF

High Resolution Phased Array Imaging using the Total Focusing Method

New Opportunities for 3D SPI

Frequency-based method to optimize the number of projections for industrial computed tomography

AUTOMATED HIGH SPEED VOLUME COMPUTED TOMOGRAPHY FOR INLINE QUALITY CONTROL

Calibration of Recorded Digital Counts to Radiance

Robot-based real-time ultrasonic tomography for industrial NDT applications

Sizing and evaluation of planar defects based on Surface Diffracted Signal Loss technique by ultrasonic phased array

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China

Introduction to Biomedical Imaging

High Resolution Phased Array Imaging using the Total Focusing Method

Experimental accuracy assessment of different measuring sensors on workpieces with varying properties

Flexible EC Array Probe for the Inspection of Complex Parts Developed Within the European VERDICT Project

Image Acquisition Systems

The smaller, simpler, safer alternative to radioisotope irradiators. Precision s MultiRad160 is ideal for irradiating larger cell cultures and/or

STRENGTH RELIABILITY OF TURBINE ROTOR ENSURING BASED ON MULTIDISCIPLINARY OPTIMIZATION Salnikov Anton* *CIAM

UMASIS, an analysis and visualization tool for developing and optimizing ultrasonic inspection techniques

FLEXIBLE DIRECT RADIOGRAPHY SYSTEM DX-D 300

A study of densitometry comparison among three radiographic processing solutions

Traceable 3D X-Ray Measurements ZEISS METROTOM

Fujifilm develops the new NDT films : Eco-Friendly HD S eries.

Development of EUV-Scatterometry for CD Characterization of Masks. Frank Scholze, Gerhard Ulm Physikalisch-Technische Bundesanstalt, Berlin, Germany

Limited view X-ray CT for dimensional analysis

GUERRILLA DEVELOP CONFERENCE JULY 07 BRIGHTON

DX-D 100 with WITH ITS EXCELLENT IMAGE QUALITY AND

CPSC 695. Data Quality Issues M. L. Gavrilova

POD Transfer Function Approach. Kevin D. Smith Pratt & Whitney MAPOD Meeting - February 4, 2005

Characterization of microshells experimented on Laser Megajoule using X-Ray tomography

Proton dose calculation algorithms and configuration data

Next Generation Phased Array UT Total Focusing Method (TFM)

A new concept for high-speed atline and inline CT for up to 100% mass production process control allowing both 3D metrology and failure analysis

Draft SPOTS Standard Part III (7)

NON-LINEAR ENGINE COMPONENT FAULT DIAGNOSIS FROM A LIMITED NUMBER OF MEASUREMENTS USING A COMBINATORIAL APPROACH

CT vs. VolumeScope: image quality and dose comparison

Vi3 X-Ray Imaging Acquisition and Analysis Software

Summary of New DARWIN TM Capabilities for Surface Damage Tolerance Assessment and Related Enhancements

Challenges of Statistical Analysis/Control in a Continuous Process

GP2Y0A Series / GP2Y0D Series Application Note

Improved Inspection of Miniaturized Interconnections by Digital X-ray Inspection and Computed Tomography

DX-D 100 WITH WIRELESS DETECTOR

Transcription:

5 th European-American Workshop on Reliability of NDE Lecture 12 Simulation Based POD Estimation for Radiographic Testing of Turbine Blades Hans-Uwe BARON *, Benjamin HENKEL *, Carsten BELLON **, Andreas DERESCH **, * MTU Aero Engines AG, ** BAM Bundesanstalt für Materialforschung und -prüfung, Abstract During manufacturing of turbine blades in some cases pores can appear. A pore is a possible starting point of a crack, which can cause breakage of the blade. Here radiographic inspection is employed for finding such pores within the turbine blade roots. As a measure for the reliability of the inspection the probability of detection (POD) is evaluated. There are several disadvantages, like costs and time for preparing and evaluating a lot of parts with defined defects, when carrying out a real POD trial. In addition, not every kind of defect can be manufactured anywhere in the blade. Radiographic simulation software presents an opportunity to estimate the POD without these disadvantages. In this case the simulation software artist is applied to a real example from the aero engine manufacturing industry. In the first step a real X-ray image with film or digital detector is made and this inspection is set up in the simulation software with the same boundary conditions (e.g. geometrical conditions, X-ray spectrum, material composition, detector). Then the image quality of the simulation is adapted to the real X-ray exposure. The adaptation is done based on measurements of contrast to noise ratio (CNR) and signal to noise ratio (SNR) on the 2-2T hole of a step wedge with an IQI according to ASTM 1742. In the simulation a defect is created in the region of interest. This defect can be varied using the SimuPOD module of the artist software. All the simulated images with the defect variations are automatically evaluated relating to flaw detectability. After setting a threshold in the â-vs.-a curve the POD curve and the a 90/95 value are calculated. With this simulation based method a very fast and cheap POD calculation is possible for many kinds of defect and also in every region of the inspected part. Only a few calibration and validation images with simple test parts are necessary. License: http://creativecommons.org/licenses/by-nd/3.0/ 1

Simulation based POD estimation for radiographic testing of turbine blades H.-U. Baron, B. Henkel, MTU Aero Engines, München, Germany C. Bellon, A. Deresch, BAM, Berlin, Germany 1 Outline Product Motivation Procedure Real X-ray Image Simulated X-ray Image Validation RT simulation supported POD method Resulting POD Summary and Conclusions 2 2

Product: Airbus A380 Biggest airliner in the world max. speed: 945 km/h max. passengers: 853 max take off weight: 560 t Range: 15000 km 4 Turbofan engines (GP7000) 3 Product: GP7000 Bypass HPC high pressure compressor HPT high pressure turbine LPT low pressure turbine Fan LPC low pressure compressor Combustion Chamber Fan diameter 2.96 m Take-off thrust 311 kn Bypass ratio 9:1 Rotational frequency 18000 1/min Partners: P&W, GE, Snecma, Techspace Aero MTU share 22.5 % 4 3

Motivation: POD of Blade Root Inspection Different defect limits for different zones (e.g. 0.6 mm defect size in blade root) For a reliable statement about detectability of the different defects a POD calculation has to be done Disadvantages when using real POD calculation Large number of parts have to be prepared Time consuming Costs Not every defect can be manufactured in different sizes and at different positions Solution = Simulation based POD 5 Motivation: RT Simulator is an easy to use and practical simulation tool generating realistic radiographic images from virtual scenes analytical + Monte-Carlo model multi core support & GPU usage live preview; undo/redo functionality; mouse interaction 6 4

Procedure: RT simulation supported POD method Exposure of real X-ray image with IQI on step wedge Adapt image quality of simulation to real X-ray image Visibility of 2-2T hole Values for SNR and Contrast Validation by comparison of simulated X-ray image with real X-ray image with defect Simulation and calculation of â-vs-a data Simulation of X-ray image Same geometrical conditions Same X-ray spectrum Same detector Creation of defect in simulated X-ray image Define variation of defect and X-ray parameters Defect size, position, kv, ma Definition of decision threshold in â-vs-a curve POD curve and a 90/95 value 7 Procedure: Real X-ray Image X-ray Tube Type: Isovolt150 Focal Spot Size: 5.5 x 5.5 mm² Voltage: 120 kv Current: 15 ma Time: 60s Film Type: Size: Packing: Screens: Agfa D4 10 x 24 cm Vacupac 0.02 / 0.02 mm Pb Geometry Film Focus Distance: 1000 mm Film Part Distance: Close Contact 8 5

Procedure: Simulation of X-ray Image Simulation of the X-ray image with the same parameters for tube, film, and geometry as in reality. 9 Procedure: Adapt image quality of simulation to real X-ray image Adapt essential image quality parameters to experiment: SNR, contrast and differential contrast Adjustments can be done using simple test exposures Simulator settings Spectrum kilovoltage Material composition, density Scattering scatter ratio Detector unsharpness, noise Exposure tube current, time 10 6

Procedure: Adapt image quality of simulation to real X-ray image Optical Density: 3.13 Optical Density: 3.00 SNR 104 CNR 2-2T Hole: 1,6 Real X-ray image Optical Density: 3.14 Optical Density: 3.00 SNR 92 CNR 2-2T Hole: 1,7 Simulated X-ray image 2-2T Hole Defect with ø 0,508 mm and depth 0,076 mm 11 Procedure: Comparison between simulated and real X-ray image Real X-Ray Image Critical zone Simulated X-Ray Image 12 7

Procedure: Creation of defect in simulated X-ray image Defect: Cylinder Diameter = Depth Exposure direction is parallel to cylinder axis Variation of size and position 13 Procedure: Validation of the simulated X-ray image Defect size 0,4 mm cylinder (depth and diameter) Real X-ray image Simulation CNR: 0,68 SNR: 52,4 CNR: 0,64 SNR: 55,2 Deviation between simulation and real X-ray image 5% acceptable 14 8

Procedure: Simulation and Calculation of POD artist module SimuPOD Generate POD from synthetic radiographs Simulate defects of varying size Overlay random variations User-friendly input Automatic image evaluation Repeated simulation with variation of defect and/or X-ray parameters (deterministic/stochastic distributions) Applied variations for this test case: Defect size from 0.25 to 0.6 mm Defect position linear, uniform Tube position ± 2 cm, uniform 15 Procedure Determination of â from simulated radiographs Visibility of defects must be estimated by software Use a model observer (derived from the Bayesian ideal observer) Models characteristics of human observer background & defect known background defect test image simulated radiograph Compute and standard deviation via linear regression t-test for significance of defect: 16 9

Procedure Definition of decision threshold for POD Human observer evaluates synthetic images to find threshold Threshold 17 Procedure: Final POD N=30 N=150 Using 150 instead of 30 data points change the a90/95 value from 0.45mm to 0.44mm 18 10

3. Summary and Conclusions RT simulation supported POD method is possible Simulation needs to be calibrated to reproduce the experimental image quality Method works well for film and digital radiography of compact defects and automated defect recognition Ongoing validation of the method is necessary (influence of the human inspector unknown) Only simple calibration and validation images are required -> fast and cheap 19 11