Richter Optica. Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models

Similar documents
Richter Optica. Instructions for Model: S-2 Dual Power Stereo Microscope

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

INSTRUCTIONS FOR STEREOSCOPIC MICROSCOPES CATALOG NUMBERS (120V) (220V) (120V) (220V)

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Richter Optica. Instructions for Model F-1 Compound Microscope

Richter Optica. Instructions for Model: MDS1 Compound Microscope

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

INSTRUCTIONS FOR MODEL C-1028 COMPOUND MICROSCOPE

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Richter Optica. Instructions for Model: HSX1 High School Microscope

Richter Optica. Instructions for Model: MDS2 Middle School Microscope

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Instruction Manual. B1 Series. Copyright 02/02 Motic Microscopes, European Division

User Manual. Binocular Zoom Stereo Microscope with Boom Stand. MicroscopeNet.com

User Manual. Binocular Stereo Microscope. MicroscopeNet.com

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Eco D-ELS-4 Stereo Microscope. Instruction Manual

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, TX Phone (210) Fax (210) INSTRUCTIONS FOR

Swift SM100 Series Stereo Microscope

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

M40 Microscope User s Manual

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

MANUAL Series ZOOM STEREO MICROSCOPE MANUAL

Richter Optica. Instructions for Models: UX1B Binocular and UX1T Trinocular Laboratory and University Biological Microscope

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Instruction Manual. B3 Series. Copyright 02/02 Motic Microscopes, European Division

User Manual. Trinocular Stereo Microscope

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Swift SM100 Series Stereo Microscope

User Manual. Trinocular Stereo Microscope

M20 Metallurgical Microscope User s Manual. Fein.

G500 SERIES MICROSCOPE OPERATION MANUAL For use with MFR# G502, G502T, G504, G504T, G505, G505T.

ACCU-SCOPE INC. 73 Mall Drive Commack, NY Phone: (631) Fax: (631)

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

MANUAL 3072 STEREO MICROSCOPE SERIES

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

SM-6 Series. User s Manual

Polarization Microscope. Omano OM349P Series. User Guide

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Mi50 Inverted Microscope User s Manual. Fein.

OMM200 and OMM200T. Metallurgical Microscope

SM-4 Series. User s Manual

Z10 SERIES Z10 Z8 Z6 MANUAL ZOOM STEREO MICROSCOPES

OLYMPUS STEREO MICROSCOPES I INSTRUCTION MANUAL I MODELS VMF,VMT&VMZ OLYMPUS

STEREO MICROSCOPE MODEL K400 / K500 / K700 INSTRUCTION MANUAL

R40POL Microscope User s Manual

3025 MICROSCOPE SERIES INSTRUCTIONS

INSTRUCTION MANUAL for STEREO MICROSCOPE FUTURO EDU CAM

Operation Manual. for Micromas ter I Micros copes. T his manual covers catalog numbers : S 11031, S 11033, and S 11035

Comprehensive Scope 2. Instruction Manual T-19011C - Monocular T-19021C - Dual Viewing T-19031C - Binocular T-19041C - Trinocular

EXAMET-4 MANUAL MICROSCOPE SERIES. 73 Mall Drive, Commack, NY (P) (F)

For documentation the instrument is available with a trinocular head which permits mounting of a video or digital camera system.

User Manual. Binocular Compound LED Microscope. MicroscopeNet.com

Therefore, all descriptions and illustrations in this instruction manual, including all specifications are subject to change without notice.

GTA PREVENTIVE MAINTENANCE CHECKS AND SERVICES ON THE ZOOM STEREOSCOPE 95R

For documentation, both instruments are available with a trinocular head which permits mounting of a video or digital camera system.

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

MANUAL EXS-210 STEREO MICROSCOPE SERIES

6600 SERIES STEREO ZOOM

148 Series. User s Manual

User instructions Stereo microscope

EXAMET-5 MANUAL MICROSCOPE SERIES. 73 Mall Drive, Commack, NY (P) (F)

User instructions Stereo microscope

INSTRUCTION MANUAL POLARIZING & ORE MICROSCOPES. Polarizing Microscopes. Ore Microscopes. Model: NYMC62B00

optech Reflected Metallurgical Microscope Model SM lnstruction Manual OPTICAL TECHNOLOGY

For your safety! General information

Cordless Comprehensive Dual Purpose Scope. Instruction Manual T-1931C T-1932C T-1933C

12100 Polarizing MANUAL MICROSCOPE SERIES. 73 Mall Drive, Commack, NY (P) (F)

Symbio Microscope. L1500 Series. Biological Upright Compound Microscopes. Operating Manual

Operation Manual (Version 1.0.0)

MANUAL HDR (1080p) MANUAL ZOOM STEREO MICROSCOPE

IM Series INSTRUCTION MANUAL. Model IM-3MET

User instructions Stereo microscope set

Lab 4 - The Microscope

User instructions Stereo zoom microscope

Teaching Microscope Instruction Manual OMTM85 and OMTM85L

NexiusZoom (EVO) HIGHLIGHTS TECHNICAL SPECIFICATIONS EYEPIECES HEAD OBJECTIVES STAND STAGE ILLUMINATION PACKAGING PRODUCT DATASHEET

40x, 400x, 1600x 3MP Digital Microscope with Screen

The Viper Spotting Scope For long-range observation, put high performance at your fingertips with the Viper spotting scope.

BPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

Operation Manual. VWR Inverted Microscope. (Version 1.0.0) VWR Inverted Microscope VWR Inverted Microscope.

User instructions Stereo zoom microscope

User instructions Stereo microscope

MICROSCOPE USER MANUAL

Lab 5 Microscopy. Introduction. Carrying the Microscope. Depth of Focus. Parts of the Compound Microscope. Magnification

Compound Microscope Instruction Manual

Transmission Polarizing Microscope OM239

Operation Manual (Version 1.0.0)

User instructions Stereo zoom microscope

Binocular Compound Microscope Instruction Manual

Swift M3600, M3700 Series Digital & Compound Microscope

EMF EMT EMTR EMX Series

Great Bay Community College Document Number: Corporate Drive Revision Number: 3

The Eye Com 7000 Dual Page Reader Operating and Maintenance Instructions

Transcription:

Richter Optica info@richter-optica.com Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models

Trinocular port for c-mount adapter Zoom Knob Focusing Holder Clamp Diopter adjustable eyepieces Magnification locking screw Separate light intensity control switches for reflected & transmitted light LED Lights Focusing Knob Built-in Ring Light Adapter Focusing Knob S6T-BL S6-SPS Zoom Knobs Focus Knobs Trinocular port for C-Mount Adapter Ring Light Attaches Here Head locking screw Track Stand Focusing Knob Magnification Adjustment Head Locking Screw Auxiliary Lens Attachment S6-TS Stage Clips LED Lights Glass Stage Plate Intensity Controls Base S6T-ILST On / Off Switch

Thank you for your purchase of a Richter Optica S6 stereo microscope. The information in this manual is provided to answer most questions that can arise when operating your microscope and to help you avoid unneccesary maintenance expenses in the future. Based on your microscope purchased, the stand may look slightly different. Please carefully read instructions before operating microscope. Nomenclature used to describe components and controls are identified on opposite page. UNPACKING Do not discard styrofoam container or packing materials until you are sure shipment is complete and undamaged (retain stryrofoam shipping container to store your microscope when it is not in use). Remove all tape and packing material used to protect microscope during shipment. Make certain lens surfaces do not come in contact with dirt, fingerprints or oil. Damage of lens surfaces occur when they come in contact with such contaminants, and image quality is reduced. ASSEMBLY Eyeshields Eyepieces Remove eyepiece covers Remove objective cover Body Upper Light Source Wire Power cord Glass Plate 1

OPERATION 1. Illumination (only for S6-BL, S6-ILST & S6-TD-LED Models) a. Before operating the microscope, adjust the intensity controls located on each side of the base to the minimum position. This should be done prior to each time light is turned on or off. Failure to do so will signifcantly shorted the life of the bulb. b. Make certain that the main voltage of your microscope corresponds to the voltage of your power outlet, either 120v or 220v. Insert microscope power cord into power outlet. c. The S6 on lighted LED stand includes a glass stage plate. This plate is ideal for viewing. transparent specimen slides or specimens that are thin enough for light to pass through them (insect wings, plant leaves, etc.) Alternate black/white contrast plates can be used when viewing opaque objects or for dissecting. To remove the stage plate on ILST stand: loosen locking set screw on front of base by unscrewing it to the left. d. For models S6-BL & S6-ILST, there are rocker switches on the base of the microscope. These switches are used to turn the light on/off. The rheostat control knobs will not work if the rocker switch is in the off position. 2. Interpupillary Adjustment This will permit each user to adjust the spacing between eyepieces to accommodate distance between their eyes. While looking through the microscope eyepieces with both eyes, grasp eyepiece tube housings with both hands and rotate them, moving eyepieces apart or together until a full field of view is observed and the images blend into one. Interpupillary distance is now corrected for your own inter-ocular distance and does not require further adjustment unless another user changes the adjustment. 3. Focusing a. Adjust zoom control knobs (located on both sides of the head) so that the lowest magnification number 0.7 is positioned at the white notch index on head. Lower magnifications have larger fields of view, making it easier to position and locate area to be viewed. b. Place object on stage plate. 2

Focusing Continued: c. Position focusing knobs in the center of focusing range. d. Use included allen key to lock and set magnification if desired. d. On mounted post models, the height of the viewing head can be adjusted up or down on the post in order to focus on different sized objects. Loosen the locking knob located on the locking support collar, allowing the support collar to slide down to bottom of post. While firmly holding focusing holder containing viewing head with one hand, loosen locking knob located on back of focusing holder so that head can move freely up or down on post. While looking through microscope, move viewing head up or down on post until object can be seen in approximate focus. Tighten focusing holder locking knob. Position the support collar under the focusing block and tighten locking knob on support collar. It is not necessary to make this adjustment every time you change objects to be viewed, so long as the different objects are of similar thickness or height. e. On models with lighted post stands, the up/down movement of the viewing head is limited to the traverse permitted by the regular focusing knobs. f. Both eyepieces have a knurled diopter adjustment ring. Rotate the diopter until the zero (0) lines up with the notch on the diopter. g. Adjust zoom control to the highest magnification by aligning the number 4.5 on the zoom knob. h. While looking through the right eyepiece with one eye, rotate focusing knob until specimen comes into sharp focus through the right eyepiece. i. Adjust zoom control knob to the lowest magnification. j. Adjust the right diopter until the image is sharp. Do not change the focusing knob position. Repeat to adjust the right diopter. k. The image should now be sharp throughout the zoom power range. 3

MAINTENANCE WARNING: For your own safety, turn switch off and remove plug from power source before maintaining your microscope. If the power cord is worn, cut or damaged in any way, have it replaced immediately to avoid shock or fire hazard. 1. Optical Maintenance a. Do not attempt to disassemble any lens components. Consult a microscope service technician when any repairs not covered by instructions are needed. b. Prior to cleaning any lens surface, brush dust or lint off lens surface using a camel hair brush. You can also use an ear syringe or canned compressed air, sold by computer stores. c. To clean eyepiece lenses, do not remove from eyepiece tube. Clean only the outer lens surface. Breathe on lens to dampen surface, then wipe with lens paper or use a cotton swab moistened with distilled water. Wipe lenses with a circular motion, applying as little pressure as possible. Avoid wiping dry lens surface as lenses are scratched easily. If excessive dirt or grease gets on lens surfaces, a small amount of Windex can be used on a cotton swab or lens tissue. To clean objective lenses, do not remove objectives from microscope. Clean front lens element only, following same procedure. 2. Mechanical Maintenance The only mechanical adjustment the microscope might require is the tension of the focusing mechanism. This has been adjusted at the factory, but over the course of time it may loosen and cause the head of the microscope to slip downward on the focusing block. The tension adjustment collar is located between arm and focus knob on left side of microscope when the stage is facing towards you. With a jewelers type screwdriver, loosen slotted set screw located on knurled surface of the tension adjustment collar. Turn collar clockwise to tighten tension, counter-clockwise to loosen tension. After adjusting, tighten set-screw to lock collar into place. NOTE: It is recommended that you leave the tension as loose as possible for ease of focusing, yet not so loose that it permits the head of the microscope to drift downward from its own weight and cause the microscope to drift out of focus. 4

TROUBLESHOOTING Problem Reason for Problem Solution OPTICAL SYSTEM Too Bright / Dark Brightness degree is not set appropriately Adjust rheostat intensity control Dirt in Field of View Double Images Dirt on Specimen Dirt on Eyepieces Dirt on Objective Lens Dirt on Stage Incorrect Interpupillary Distance Incorrect Diopter Setting Two Different Magnification Eyepieces Clean the sample Clean the Eyepieces Clean the Objective Clean the Stage Readjust Interpupillary Distance Readjust Diopters Insert Same Eyepieces Unclear Image Dirt on Objective Lens Clean the Objective Images Blurs on Zoom FOCUSING UNIT Incorrect Diopter Setting Incorrect Working Distance or Focusing Setting Readjust Diopters Check Working Distance & Focusing Focusing Knob is Stiff Focusing Knob Tension is Too Tight Loosen tension* Microscope Head is Falling Focusing Knob Tension is Too Loose Tighten tension* ADJUST MAGNIFICATION Zoom Control Knob Will Not Turn Magnification lock may be Activated Loosen Magnification Lock Screw on Front of Microscope Body *Loosening & Tightening focusing tension depends on the microscope stand you have. The BL stand adjusts the focus tension by holding both focus knobs (left & right) and while holding the left steady, rotating the right knob. The ILST microscope stand focus is adjusted similarly by holding both knobs and rotating the right knob forward or back to tighten or loosen. 5

EYEPIECE RETICLE INSTALLATION The Richter Optica S6 stereo microscope widefield high-eyepoint 10x and 15x eyepieces both accept a 25mm diameter reticle. To install the reticle: 1. Remove the eyepiece from the eyetube and turn the eyepiece upside down. 2. Twist out and remove the threaded retaining ring from the bottom of the eyepiece. 3. Place the eyepiece reticle in the eyepiece with the inscription side facing the front of the eyepiece. 4. Screw the retaining ring back into the bottom of the eyepiece to hold the reticle in place. 6

S6 STEREO MICROSCOPE MAGNIFICATION The Richter Optica S6 stereo microscope can acheive different magnifications based on the eyepieces and auxiliary lenses used. Refer to the chart below in order to select the proper eyepiece and auxiliary lens accessories to meet your needs. Auxiliary Lens 0.5x 1x (none) 1.5x Working Distance 177mm 100mm 47mm Total Magnification 3.5x - 22.5x Eyepieces Widefield 10x Widefield 15x Widefield 20x Field Size (mm) 7x - 45x 28.5-4.4 10.5x - 67.5x 19-3 Total Magnification 57.1-8.9 5.25x - 33.75x 10.5x - 67.5x 15.75x - 101.25x Field Size (mm) 42.9-6.7 21.4-3.3 14.2-2.2 Total Magnification 7x - 45x 14x - 90x 21x - 135x Field Size (mm) 28.6-4.4 14.3-2.2 9.5-1.5 7