GUIDE 63. Guide to the development and inclusion of safety aspects in International Standards for medical devices

Similar documents
Sýnishorn ISO/IEC INTERNATIONAL STANDARD. Information technology Security techniques Information security risk management

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD

This document is a preview generated by EVS

ISO/IEC INTERNATIONAL STANDARD. Systems and software engineering Measurement process. Ingénierie des systèmes et du logiciel Processus de mesure

ISO/IEC INTERNATIONAL STANDARD. Information technology Security techniques Information security risk management

ISO INTERNATIONAL STANDARD. Information and documentation International standard name identifier (ISNI)

ISO INTERNATIONAL STANDARD. Information and documentation International Standard Musical Work Code (ISWC)

INTERNATIONAL STANDARD

ISO/IEC INTERNATIONAL STANDARD. Information technology Security techniques Governance of information security

INTERNATIONAL STANDARD

ISO/IEC TR TECHNICAL REPORT. Information technology Telecommunications and information exchange between systems Managed P2P: Framework

ISO 4395 INTERNATIONAL STANDARD. Fluid power systems and components Cylinder piston rod end types and dimensions

ISO/IEC Information technology Security techniques Network security. Part 5:

ISO/IEC INTERNATIONAL STANDARD. Information technology Cloud computing Reference architecture

INTERNATIONAL STANDARD

ISO Aseptic processing of health care products Part 6: Isolator systems AMENDMENT 1

ISO 5208 INTERNATIONAL STANDARD. Industrial valves Pressure testing of metallic valves

This is a preview - click here to buy the full publication GUIDE 51. Safety aspects Guidelines for their inclusion in standards. Second edition 1999

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Marking of performance characteristics on hydraulic filters

ISO INTERNATIONAL STANDARD. Ophthalmic optics Contact lenses and contact lens care products Fundamental requirements

ISO INTERNATIONAL STANDARD. Cleanrooms and associated controlled environments Part 5: Operations

ISO INTERNATIONAL STANDARD. Wheat and wheat flour Gluten content Part 1: Determination of wet gluten by a manual method

This document is a preview generated by EVS

ISO/IEC TR TECHNICAL REPORT. Systems and software engineering Life cycle management Part 1: Guide for life cycle management

ISO/IEC INTERNATIONAL STANDARD. Information technology Security techniques Information security incident management

ISO INTERNATIONAL STANDARD

ISO/IEC INTERNATIONAL STANDARD. Information technology Cloud computing Overview and vocabulary

ISO INTERNATIONAL STANDARD. Glass in building Silvered, flat-glass mirror. Verre dans la construction Miroir argenté en verre plat

ISO INTERNATIONAL STANDARD

ISO/IEC TR TECHNICAL REPORT. Information technology Database languages SQL Technical Reports Part 1: XQuery Regular Expression Support in SQL

ISO INTERNATIONAL STANDARD. Road vehicles Open interface for embedded automotive applications Part 6: OSEK/VDX Implementation Language (OIL)

PROOF/ÉPREUVE. Safety of machinery Relationship with ISO Part 1: How ISO relates to type-b and type-c standards

ISO INTERNATIONAL STANDARD. Ergonomics of human-system interaction Part 110: Dialogue principles

Information technology Guidelines for the application of ISO 9001:2008 to IT service management and its integration with ISO/IEC :2011

This document is a preview generated by EVS

ISO/IEC TS Conformity assessment Guidelines for determining the duration of management system certification audits

ISO INTERNATIONAL STANDARD. Textile machinery Opener and cleaner for staple fibres preparation Vocabulary and principles of construction

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Ergonomic design of control centres Part 2: Principles for the arrangement of control suites

ISO/IEC INTERNATIONAL STANDARD. Information technology Security techniques Information security management systems Overview and vocabulary

ISO/IEC INTERNATIONAL STANDARD. Information technology MPEG extensible middleware (MXM) Part 3: MXM reference software

ISO INTERNATIONAL STANDARD. Road vehicles FlexRay communications system Part 1: General information and use case definition

ISO INTERNATIONAL STANDARD. Machine tools Connecting dimensions of spindle noses and work holding chucks Part 4: Cylindrical connection

ISO AMENDMENT 1 Ergonomic requirements for office work with visual display terminals (VDTs) General introduction

ISO/IEC INTERNATIONAL STANDARD. Information technology Learning, education, and training Content packaging Part 2: XML binding

ISO/IEC INTERNATIONAL STANDARD. Information technology Security techniques Lightweight cryptography Part 2: Block ciphers

ISO 7251 INTERNATIONAL STANDARD

Mobile robots Vocabulary

ISO/IEC Systems and software engineering Systems and software Quality Requirements and Evaluation (SQuaRE) Planning and management

ISO/IEC INTERNATIONAL STANDARD. Information technology Guideline for the evaluation and selection of CASE tools

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD. Graphical symbols for diagrams Part 8: Valves and dampers

ISO 1173 INTERNATIONAL STANDARD

SANS 3779:2010 Edition 2 ISO 3779:2009 Edition 4

ISO INTERNATIONAL STANDARD. Corrosion of metals and alloys Determination of the critical pitting temperature under potientiostatic control

ISO INTERNATIONAL STANDARD. Condition monitoring and diagnostics of machines General guidelines on using performance parameters

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Sensory analysis Methodology General guidance for establishing a sensory profile

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD. Rotary shaft lip-type seals incorporating elastomeric sealing elements Part 3: Storage, handling and installation

Transcription:

GUIDE 63 Guide to the development and inclusion of safety aspects in International Standards for medical devices Second edition 2012 ISO/IEC 2012

ISO/IEC GUIDE 63:2012(E) This is a preview - click here to buy the full publication COPYRIGHT PROTECTED DOCUMENT ISO/IEC 2012 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO's member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyright@iso.org Web www.iso.org Published in Switzerland ii ISO/IEC 2012 All rights reserved

ISO/IEC GUIDE 63:2012(E) Contents Page Foreword... iv Introduction... v 1 Scope... 1 2 Terms and definitions... 1 3 Principles for preparing medical device safety standards... 4 3.1 General considerations... 4 3.2 Scope of safety standards... 5 3.3 Types of standards... 5 3.4 Taking a practical view of safety... 6 3.5 Managing risks... 6 3.6 Risk acceptability criteria... 7 3.7 Risk control methods/methodology... 7 3.8 Coordination of medical device safety standards... 7 3.9 Regulatory implications... 7 4 Risk-based framework for developing a medical device safety standard... 8 4.1 General... 8 4.2 Management of the risk-based framework... 8 4.3 Application and characteristics... 8 4.4 Identification of hazards and hazardous situations... 9 4.5 Types of hazards and hazardous situations... 10 4.6 Systematic or random nature of risks... 12 4.7 Risk estimation... 13 4.8 Risk acceptability criteria... 14 4.9 Risk evaluation... 15 4.10 Risks to be controlled by the standard... 15 4.11 Conclusion... 16 5 Facilitating the implementation of ISO 14971 though product or process standards... 16 5.1 Product standards... 16 5.2 Process standards... 17 5.3 Overview of the application of medical device safety standards in an ISO 14971 framework... 17 Annex A (informative) Product and process safety standards... 19 Annex B (informative) Risk information... 20 Bibliography... 21 ISO/IEC 2012 All rights reserved iii

ISO/IEC GUIDE 63:2012(E) This is a preview - click here to buy the full publication Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. Draft Guides adopted by the responsible Committee or Group are circulated to the member bodies for voting. Publication as a Guide requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO/IEC Guide 63 was prepared jointly by ISO/TC 210, Quality management and corresponding general aspects for medical devices, and IEC/SC 62A, Common aspects of electrical equipment used in medical practice, in a Joint Working Group, Application of risk management to medical devices. This second edition cancels and replaces the first edition (ISO/IEC Guide 63:1999), which has been technically revised. iv ISO/IEC 2012 All rights reserved

ISO/IEC GUIDE 63:2012(E) Introduction ISO/IEC Guide 51 was the first of a series of guides intended to provide a harmonized approach to the concept of safety when preparing International Standards. ISO/IEC Guide 51 anticipated the need for sectoral guides such as this Guide. Consistent with ISO/IEC Guide 51, additional guidance might be needed for sectors within the broad category of medical devices. The concept of safety, including safety-related performance and usability, is closely related to safeguarding the integrity of the patients who are the subjects of medical care, as well as that of those persons who are giving the care and any other persons. As medical devices and medical systems have become more complex, the diligence required to ensure their safety has similarly increased. As different circumstances warrant different approaches to ensuring safety, it is impossible to provide precise requirements and recommendations that apply to every case. However, these guidelines, when followed on a judicious use when applicable basis, will help in developing reasonably consistent standards. ISO/IEC 2012 All rights reserved v

ISO/IEC GUIDE 63:2012(E) Guide to the development and inclusion of safety aspects in International Standards for medical devices 1 Scope This Guide provides guidance to standards writers on how to include safety aspects in the development of medical device safety standards intended to be used within the risk management framework established in ISO 14971. It expands on the concepts developed in ISO/IEC Guide 51 to include safety-related performance and usability. This Guide is intended to be read in conjunction with ISO/IEC Guide 51 and ISO 14971. ISO/IEC 2012 All rights reserved 1