Shore D Hardness Tester TH210. Instruction Manual. TIME GROUP INC. Beijing Time High Technology Ltd

Similar documents
ISH-DSA DIGITAL SHORE DUROMETER OPERATION MANUAL

MANUAL SURFACE ROUGHNESS TESTER TR-200 PARTNERS IN PRECISION

5.6" Multi-function Monitor

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443

2 x Dynamic Arms on 135 Post with C-Clamp

Laser Roughness Tester TRL400 Instruction Manual

impact INSTRUCTIONS LiteTrek 4.0 Monolight lighting equipment and accessories

MANUAL TV-100 TV-100

Self-leveling Laser Marker (4V1HXL)

TEL: / FAX:

Mobile Access, TimeTec Smart Flap Turnstile FTS 2100B & 2200B Installation Manual

Flap Barrier User Manual

WEASEL N/B MAINTENANCE

FG-3000R Digital Force Gauge Operation Manual

FG-3000 Digital Force Gauge Operation Manual

RESS. Manual. Rotary-Ball-Camera Pro. The Producer. Visual Inspection Sweep Instruments Measuring Instruments

DOT MATRIX PRINTER SP6000 SERIES

Welch Allyn Connex Vital Signs Monitor 6000 Power Supply Replacement

Removing and Replacing Parts

352 Trackrunner. User Manual. TELEPHONE

ASSET LGA1366 Top-side Probe

SRT5000 Surface Roughness Tester. Instruction Manual

NIR Moisture Analyzer KB-30

VJ-1618 INSTALLATION MANUAL

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

Fuser. Figure Remove the fuser assembly (1 of 2) 184 Chapter 5 Removal and replacement ENWW

Magnetic Upright Bike

FG-7000 Digital Force Gauge Operation Manual

Data Sheet: LDS 1367 Date:

X-CAM A10-3H 3 Axis Gimbal for GOPRO. User Manual ( V2.00 )

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

FPC connectors (0.2mm pitch) Back lock

V1.0. User Manual Sparkular mini. Liuyang Xiaowen Electronic Technologies Co., Ltd

Table of Contents: TOPIC: Safe Operation: READ THIS FIRST Page: 3 Warranty 4 Specifications 4 Installation 5-7 Operating Instructions 8 Parts Diagram

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT

USER GUIDE 3D PluraView 2,5k und 4k

skyline 70 Fluid Head OPERATOR S MANUAL #1050 Skyline 70 Fluid Head

ft Aspen Fir Item # Commercial ITEM Lights

Power Series Camera Support

REMOTE CONTROLLED HEAD. User Manual. pdf version of the manual available for download: 9/2016

Currency Detector. Operation Manual South Grand Ave., Glendora, CA

Multi-Function Smart Indicator User Manual

FG-7000L Digital Force Gauge Operation Manual

operating instructions

VPC-64/ VPX-64 VIDEO POLE CAMERA OPERATION MANUAL

PRECISION MEASURING INSTRUMENTS

Electric Multipliers Operating Instructions Rev 1.0

Upgrade & Replacement

OPERATING USER MANUAL for PRESSURE RECORDERS

Operation Manual (B) KVR-2418 (24L) Fanuc OiMD CNC. KENT INDUSTRIAL (USA) INC Edinger Ave., Tustin, CA 92780

-42±3dB (0dB=1V/Pa at 1 KHz) 2.0V 2.2KΩ MADE BY CHECKED BY APPROVED BY. Revision level Description of changes Changed date

OMM200 and OMM200T. Metallurgical Microscope

Operation Manual for OPM-1315 Optical Power Meter

Inductive Cylinder Position Sensors

Motorola Moto Z Play Motherboard Replacement

Removal and Installation8

Further Information can be found at

Warning Before Installation. Package Contents EN - 1. Refer to your user's manual for the operating temperature.

High Accuracy Gloss Meter Operation Manual. This manual is only suitable for our single angle and multi-angles gloss meters.

Operating Manual. AdirPro HV8RL Red Beam Horizontal/Vertical Laser level

MANUAL TR-200. Surface roughness tester

Mi Smartphone Gimbal Manual Please read the manual carefully before using the product.

imac Intel 21.5" EMC 2389 Stand Replacement

Model Affected: MedSystem III Infusion Pump Multi-Channel, Model 286X Date: June 2008 Subject: Level of Testing Guidelines/Functional Test Updates

Cheetah Light LLC. (214) Instruction Manual

User's Guide. Model W 3-in-1 Switching DC Power Supply

Written By: Ben Eisenman

Ex-mark:: ATEX Certificate: License: CNEx XK Veilux SVEX-Q20 Explosion Proof Dome Camera

ipad Charge & Sync Cart Model MCC2 ipad Cart 430-MCC2-User Manual-010 Is a Registered Trademark of Apple Inc. ipad

User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at

Operators Guide. Vision 100 Pan & Tilt Head. Vinten Camera Control Solutions

Quick Start Guide V5.1.

VJ-1614 INSTALLATION MANUAL

Mk II 3DR MULTI-LINE LASER INSTRUCTION MANUAL

Alignment Software for Linear Guides

Reflowing Xbox 360 Motherboard

EDUCATIONAL SPECTROPHOTOMETER ACCESSORY KIT AND EDUCATIONAL SPECTROPHOTOMETER SYSTEM

INSTRUCTION MANUAL. * Design and Specifications are subject to change without notice. ver. 1.0 PRINTED IN KOREA

-Direct.com FG-3000 Digital Force Gauge Operation Manual

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

ULTRASONIC. Proximity Sensors. Series UX micro. Key-Features:

Gateway Profile 4 service guide

VJ-1604 INSTALLATION MANUAL

LH 700. Spare parts list. Forward and reversible plate. Valid from serial number. LH 700 Hatz Electric start 810 mm Bio

INDEX WARRANTY CALIBRATION Checking Calibration 7.20 Field Calibration Adjustment 7.30 Special Calibraton

Portable Hardness Tester. User's Manual

optris CoolingJacket Advanced

Andonstar ADSM302 Digital Microscope USER MANUAL

Phone accessories / Photography

C-pan arm USERS INSTRUCTIONS

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK

Moving-Minds.com Treadmill Desk Operation

AVT Model Tripod.

LH 700. Spare parts list. Forward and reversible plate. Valid from serial number. LH 700 Hatz Electric start 810 mm Bio

BPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

DIGITAL HEIGHT GAUGE OPERATION AND MAINTENANCE MANUAL

Digital Menu Board Wall Mount Installation Instructions

Ultra short throw lens installation

ORYON RING LIGHTS. 14 in. Ring Light and 18 in. Ring Light. Quick Start Guide. What s Included

TCT Mobile Limited Martell lite

Transcription:

Shore D Hardness Tester TH210 Instruction Manual TIME GROUP INC. Beijing Time High Technology Ltd 1

Contents Chapter 1. Introduction... 1 1.1 Main features and application...4 1.2 Fundamental...4 1.3 Basis...5 Chapter 2. Technical Specification......5 Chapter 3. Main functions and configuration... 6 3.1 Main functions...6 3.2 Basic configurations...6 3.3 Optional configurations...7 Chapter 4. Composition... 7 4.1 Composition of main unit See figure 2...7 4.2 Usage of protective sleeve...8 4.3 Usage of battery house...8 4.4 Usage of joint cover...10 4.5 Usage of display screen...11 2

4.6 Usage of press button...12 4.7 Usage of communication interface and power adapter... Chapter 5. Functions setting... 13 5.1 Start...13 5.2 Max value function...14 5.3 Test times function and average value function setting...15 5.4 Auto turn off function...18 Chapter 6. Measuring... 19 6.1 Preparation before measuring...19 6.2 Calibration...19 6.3 Operation method...20 6.4 Communication with computer...21 Chapter 7. Attention items... 24 Chapter 8. Maintenance... 24 3

Chapter 1. Introduction 1.1 Main features and application TIME TH210 Shore D hardness tester (hereafter called hardness tester) is a kind of advanced integral digital hardness tester. It includes measuring device and data processing system. It is of the merit of advanced technology, pocketsize, accurate measring data, appearance beatiful, light weight, and easy to operate. It can be connected with computer by RS-232 communication cable. It is mainly used to measure hardness of hard plastic and rubber such as heat plasticity, hard resin, floor materials, bowling etc. Especially suitable for finished products in working situation. 1.2 Fundamental When the steel indenter of certain shape is pushed into the sample surface vertically with testing force, and when surfaces of pressure foot and the sample touched completely (see figure 1), the indenter extends out for a certain length L from the pressure foot plane. Greater length L means lower Shore hardness value and smaller length L means bigger Shore hardness value. The formula is HD=100-L/0.025, HD is Shore D hardness value in the formula.the formula indicates that the hardness value is relevant to displacement of indenter. Displacement of 4

the indenter is measured by the sensor, then the value is given through calculation and processing of the CPU. figure 1 1.3 Basis International standards: Rubber Determination of indentation hardness by means of pocket hardness meter ISO7619 Plastics and ebonite Determination of indentation hardness by means of a durometer Shore hardness ISO868 America standards: Standard Test Method for Rubber Property Durometer Hardness STM D 2240-02 Japenese standards: Hardness Testing methods for rubber vulcanized or thermoplastic JIS K6253 Chapter 2. Technical Specification: Measuring range 0HD 100HD 5

Measuring error within 20HD 90HD, error ±1 HD Resolution: 0.2HD Environmental temperature 0 ºC 40 C Power supply 1.55V 3 button batteries and 5V AC- DC adapter Dimensions: 173mm 56mm 42mm Weight: 230g Chapter 3. Main functions and configuration 3.1 Main functions Peak value locked storage, average value calculating and low-voltage alarming. Data communication with computer by use of RS-232 communication cable of company Shut off automatically. 3.2 Basic configurations TH210 main unit Three SR44 button batteries 6

3.3 Optional configurations: RS-232 communication cable 5V AC- DC power adapter Shore hardness stand of TH210FJ Chapter 4. Composition 4.1 Composition of main unit See figure 2 4 5 6 7 8 BATTERY SR44 1.55V 3 1 2 3 (figure 2) 1. communication interface 2. power plug board 3. protective sleeve 4. display screen 5. press button 6. measuring device 7. battery house 8. joint cover 7

4.2 Usage of protective sleeve The protective sleeve is used to prevent indenter from damage under non working condition. Before put into service, first take off protective sleeve. Grasp and pull out it by hand. When finished measuring, protective sleeve should be pulled on in time. Put protective sleeve on cylinder and push up untill it clamped closely with main unit, see figure 3. figure 3 4.3 Usage of battery house Pull out and turn the battery house slightly to make it rotate about 90 around axis with thumb, see figure 4. Put into three button batteries. Take care of positive pole symbol consistently. At last, turn battery house reversely until clamped closely with main unit, see figure 5. 8

figure 4 figure 5 9

4.4 Usage of joint cover The joint cover is mainly used to close joint hole on the top of main unit. When measuring by operating stand, it must be removed and let out screw. Press the arris on the cover by thumb and push it down ( reverse screen direction), see figure 6. Then completed removal. The assembling method of joint cover is similar with disassembling. figure 6 10

4.5 Usage of display screen Screen is used to display results as well as working states of tester. The screen is divided into 5 displaying areas which is stated as follow, see figure 7 1 2 3 4 5 figure 7 1---MAX Max value function (tester locked automatically and stored peak value), 2---AVE Average value function, 3---BATT Low-voltage indication, 4---Hardness value 5---Test times, 11

4.6 Usage of press button Buttons is used to turn on or turn off power as well as set functions, see figure 8: N/AVE---- Test times function and Average function button, MAX------Max value function button, ON/OFF---Switch button red. figure 8 4.7 Usage of communication interface and power adapter It can communicate with computer by RS-232 communication cable. It can use 4.5V AC-DC power adapter instead of batteries, see figure 9. 12

1 2 3 4 5 figure 9 1. Computer 2. Communication cable 3. AC-DC power adapter 4. Hardness tester 5. Sample Chapter 5. Functions setting 5.1 Start Press button ON/OFF screen displays 0 firstly after seconds,the data displayed changed as 00.0. At same time, the program of hardness tester starts to work, see figure 10. Press switch button ON/OFF again, the machine power off. 13

figure 10 5.2 Max value function Press MAX button, screen displays MAX symbol, see figure 11. The value is the maximum of once test (auto locks peak value function). If you want to cancel this function, only need to press MAX again(max symbol vanishes). Under MAX situation (when do not set Ave. function), it needs to press button MAX to clear zero before next measurement ( MAX symbol vanishes correspondingly), then press MAX again to start measuring. 14

figure 11 5.3 Test times function and average value function setting Press down button N/AVE (the MAX function do not be set), the 00.0 vanishes and displays AVE symbol at same time as well as display test times on right bottom corner ( before setting, it displays the test times to be set last time, the test times is supposed as 7 on illustration), see figure 12. At this moment, the test times setting should be carried on. The setting method sees below 5.3.1. Supposed setting value is 3 shown on screen, see figure 13. Seconds later of completed setting, displaying area restore hardness value as 00.0 and test times changed as 0 at same time, see figure 14. It indicates setting successful and can be put into measuring situation. If want to cancel this function, only need to press button N/AVE again, AVE symbol and test times vanishes at this moment. 15

figure 12 figure 13 figure 14 5.3.1 Setting methods of test times Under figure 12 state, the test times can be set by press button N/AVE continually. The max test times is 9, in which the times can be circled within 0 9 range. There are two kinds of setting method: 16

Method 1 Press button N/AVE for a while, the times circulated among 0 9 range until it reaches requirement, then release button at once and completed. Method 2 Press button N/AVE repeatedly. The value adds one for every times press in which the times circulated among 0 9 range until reaches requirement, then release button at once and completed. After completed test times setting, machine is in ready state for testing, see figure 14. 5.3.2 Average value setting: After test times being set, hardness tester can judge based on test times. When test times is among 3 9, hardness tester displays current measured value and test times of this test. When reached the set times, automatically cancels rough error and displays average value. If rough error is too larger, displays E., see figure 15. When test times is set as 2, arithmetical mean of the two tested data will be displayed. When test times is set as 1, tester displays the measure value only. After average value displays for 8 seconds,hardness tester clears zero automatically and restores ready state. The times to be set is still valid. User can record measured data by manual and calculates arithmetic mean. The average value is divided as max average value and random average value. When calculating max average value, the max function and 17

average function should be set and displays MAX and AVE symbol at same time, see figure 16. Their setting method is the same as above mentioned and setting order is not required. When calculating random average value, only need to set average function and displays AVE on screen, see figure 14. The setting method is the same as above mentioned figure 15 figure 16 5.4 Auto turn off function If tester is in ready state for three minutes, and flashes on screen for fifteen seconds then turns off automatically. 18

Chapter 6. Measuring 6.1 Preparation before measuring The preparation of sample: The sample thickness should be equable, surface smooth, no bubble inner, no damaged, no impurities and so on. Tester preparation: disassemble protective sleeve and put into batteries or connect power adapter. 6.2 Calibration 6.2.1 Zero point calibration: After switch on power, hardness tester is in ready state. The protrusion length of indenter needle is max, the hardness value displayed on the screen is zero. 6.2.2 Non zero point calibration Make bottom surface of pressure foot of hardness tester touch glass surface completely. At this moment, hardness value displayed should be 100 on the screen, see figure 17. Note: when calibrating in this method, in order to protect indenter, it should avoid indenter point to touch glass promptly and rudely. Otherwise, it is easy to damage the point of indenter needle of hardness tester and operate abnormally. 19

figure 17 6.3 Operation method 6.3.1 Manual measure: Place the sample on the slab. Hold the tester and press indenter needle into sample vertically and slowly to avoid any shake. When the bottom of pressure foot touches the sample surface completely, read the value within 1 20

second. The displayed value then is the hardness value of the sample. 6.3.2 Measuring by the operating stand: Before using Shore hardness operating stand for measurement, the hardness tester should be assembled with the operating stand firstly, the assembled state see figure 18. Assemble 5 kg balancing weight on top of fixing rod through its middle hole. Place sample 3 on working table 2, then loosen locked wheel. Adjust height between hardness tester 4 and sample 3 by using of lifting and decending sliding arm 9. Make proper distance between indenter point and sample surface (forbid to touch). Fasten locked wheel 10. Fix sliding arm 9, then press down handle 7. At this moment, test sample 3 moves up with working table 2 until the pressure foot 4 touches sample 3 surface with balancing weight 5 lifted up slightly. The value displayed on the screen is hardness value, read it within 1 second. 6.4 Communication with computer This tester can communicate with computer which the band rate is 9600. The data is trasfered by text file which can receive by common communication software (such as super tecnical device of WINDOWS). The RS-232 communication cable is needed to connect the tester with a computer, see figure 9. It can send signal to computer when gets the reading value. The operation procedure is as follow when using super terminal device of WINDOWS: 21

6.4.1 Connect the nine cores bottom of RS-232 communication cable to series interface of computer. Insert the other bottom into communication interface of hardness tester (series interface), see figure 9. Switch on the tester. 6.4.2 Click start program Accessories communication on WINDOWS to Hyperterminal. 6.4.3 Run Hyperterminal, type in a file name at new established connection,then press Enter. 6.4.4 Select the series interface of communication cable, then select band rate 9600, press Enter. At this moment, the measured value should be displayed on computer. 6.4.5 If you want to store the measured result, select Disconnect under dial menu of Hyperterminal, select save as under file menu. Type in a file s name. That is OK. 22

BATTERY SR44 1.55V 3 figure 20 1. base 2. work table 3. sample 4. hardness tester 5. balancing weight 6. balancing weight fixing rod 7. handle 8. upright post 9. sliding arm 10. lock wheel 23

Chapter 7. Attention items 7.1. The indenter of hardness tester is sharp cone, forbid to touch it with glass plate forcely in order to protect it. Otherwise, it is easy to be damaged and to operate abnormally. 7.2. Forbid hardness tester collision and fall break. After service, pull on protective sleeve so as to protect the indenter needle. 7.3. When displays symbol BATT in low-voltage, see figure 8, replace batteries in time and pay attention to the pole of batteries, see figure 5. 7.4 After completed measurement by using operating stand, see figure 7, close the joint cover of hardness tester so as to avoid dust entering into. Chapter 8. Maintenance 8.1. Routine maintenance This hardness tester should avoid impact and heavy loading, and keep away from strong magnetic field, damp or oil environment. If store for long time and do not use it, take out batteries and take care of them. 24

When do not using the tester, please put it into packing box. 8.2. Maintenance If any abnormal phenomenon occurs, please contact the service maintenance center of company. 8.3. The list of non maintenance parts Items Name Quantity Remarks 1 Indenter needle 1 2 Button battery 3 25

Points for consumers attention 1. From purchased date, the products occur any fault except for non guarantee maintenance parts, will free maintain by warranty card and inovice copy within one year. If you could not show above mentioned requirement, company calculates guarantee period in accordance with the date of leaving factory, valid period is one year. 2. If the fault product exceeds maintenance period, in accordance with stipulation of Company, it will be taken charge of maintenance and service. 3. The special configuration out of Company s approved products would take fees in accordance with related standards. 26

4. The product should not receive free maintenance service if belongs to conditions as follow: storage unsuitable, operated incorrectly which is not in accordance with manual book, disassembled, altered by oneself as well as no purchasing proof. 27