Agilent U2941A Parametric Test Fixture

Similar documents
Agilent 16442B. User s Guide. Agilent Technologies

Errata. Agilent References in this manual. About this manual. Support for your product

Agilent U2941A Parametric Test Fixture

Agilent E4418/19A Power Meter Hardware Upgrade Kit

Errata. Agilent References in this manual. About this manual. Support for your product

Agilent OBSAI Protocol Tester

Agilent 70612B K18 Switch Matrix

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

Firmware Guide. Keysight PXIe Chassis Family

* * Agilent Power Distribution Unit (PDU) Installation Guide

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

Keysight GUI Data Logger Software for U1731C, U1732C, and U1733C Handheld LCR Meter

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

Keysight U2722A/U2723A USB Modular Source Measure Units

Agilent N2739A 1000 Series Oscilloscope Rack Mount Kit

Agilent Technologies E5385A 100-Pin Probe

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit

Agilent CytoGenomics 2.5

Agilent Gb/s Serial BERT

Agilent SureCall 3.5. Installation Guide. Agilent Technologies. For Research Use Only. Not for use in diagnostic procedures.

Agilent Connector Plate

Agilent U2722A/U2723A USB Modular Source Measure Unit

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

Agilent E2943A/E2944A ATCA Probes for Advanced Switching Interconnect

Test Fixture. User s Guide ABCDE. HP Part No Printed in Japan August Edition 2 E0897

87421/22A Power Supply. Operating and Service Manual

Agilent M9502A and M9505A AXIe Chassis Firmware Revision. Firmware Update Guide. Agilent Technologies

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit

Agilent InfiniiMax II 1168A/1169A Probes

DDR/LPDDR Custom Configuration Creator Tool. User s Guide

Agilent Protocol Analyzer and Jammer for USB. Quick Start Guide

BenchCel Workstations Software

Agilent W2100 Antenna Modeling Design System

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

Agilent OpenLAB Data Store Administration. Guide for Administrators

Agilent 34959A Breadboard Module

Agilent Technologies 11667A DC to 18 GHz Power Splitter

Keysight E7515A UXM Firmware Update Tool

Installation Note. Agilent Technologies 85105A Option 50 Installation Instructions for RF Switch Replacement Kit

Agilent U2600A Series USB Isolated Digital I/O Devices. Data Sheet

Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz

Quick Start/Installation Guide

Agilent N4880A. Reference Clock Multiplier. User s Guide

Agilent G2721AA/G2733AA

Keysight N7015A/16A Type-C Test Kit. User Guide

Keysight 11878A 50 Ohm 3.5 mm Adapter Kit

TETRIS 2500 High Impedance Active Probe. Instruction Manual

TRC-190 User s Manual

Agilent U2751A USB Modular Switch Matrix. Data Sheet

Agilent E5072A Network Analyzer

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Keysight 42941A Impedance Probe Kit

86100 Series Infiniium DCA Oscilloscope

PML 791-RO Low-Z Passive Probe. Instruction Manual

TRC-190 User s Manual

Manual Version: V1.00. Video Decoder Quick Guide

Agilent Softtouch 2.0 Midbus Probe

EVO-TM2A EVO-TM2B Touch Screen Monitor

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Operations and Installation Manual. Keysight 85132E/F 3.5 mm to 7 mm Test Port Return Cables

Agilent E2094M IO Libraries

Agilent OpenLAB. Data Store. Maintenance Guide

Microscan Barcode Reader

Agilent CSV Export Utility

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Installation Note. Configurable Test Set Upgrade Kit. For PNA Series RF Network Analyzers (E8801A, E8802A, and E8803A) Network Analyzer Model Number

Agilent TS-8989 PXI Functional Test System

Keysight Add Source and Receiver Attenuators Upgrade Kit

Getting Started with the Agilent Serial BERT N4906B. You only need a few minutes to get started with the Serial BERT.

Agilent OpenLAB Chromatography Data System (CDS)

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Agilent TS-5000 Functional Test System

±15 V Current-Limited Power Supply

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

Agilent L4411A 6 ½ Digit Multimeter

RZ2 BioAmp Processor. Operator s Manual

Keysight Combiner and Mechanical Switches Upgrade Kit

Keysight 54006A 6 GHz Passive Divider Probe Kit. User s Guide

38 MHz Passive Voltage Probe R&S RT-ZP1X

Keysight N5191A/93A UXG X-Series Agile Signal Generator

Agilent Series Logic Analysis System

Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

Model 2657A-LIM-3 LO Interconnect Module

3M Wrist Strap and Ground Monitor 773. User s Guide

Agilent OpenLAB Chromatography Data System (CDS)

Agilent 34970A BenchLink Data Logger 3

User s Manual Power Supply IM E. 5th Edition

Agilent TS-8989 PXI Functional Test System

Agilent G6011A Quiet Cover MS

Getting Started Guide

Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit

OPERATING AND SERVICE MANUAL SPECIAL SUPPLEMENT

1690-Series Logic Analyzers

Agilent U2751A USB Modular Switch Matrix. Data Sheet

Agilent 89600B VSA. Software Installation Guide

Agilent Technologies. PXI 6½ Digit Multimeters. Startup Guide M9181A, M9182A, M9183A. Agilent Technologies

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

Transcription:

Agilent U2941A Parametric Test Fixture Operating Guide Agilent Technologies

Notices Agilent Technologies, Inc. 2008 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Agilent Technologies, Inc. as governed by United States and international copyright laws. Manual Part Number U2941-90001 Edition First Edition, November 1, 2008 Printed in Malaysia Agilent Technologies, Inc. 3501 Stevens Creek Blvd. Santa Clara, CA 95052 USA Warranty The material contained in this document is provided as is, and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Agilent shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein. Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the separate agreement shall control. Technology Licenses The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license. Restricted Rights Legend U.S. Government Restricted Rights. Software and technical data rights granted to the federal government include only those rights customarily provided to end user customers. Agilent provides this customary commercial license in Software and technical data pursuant to FAR 12.211 (Technical Data) and 12.212 (Computer Software) and, for the Department of Defense, DFARS 252.227-7015 (Technical Data - Commercial Items) and DFARS 227.7202-3 (Rights in Commercial Computer Software or Computer Software Documentation). Safety Notices CAUTION A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. WARNING A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. II U2941A Operating Guide

Safety Symbols The following symbols on the instrument and in the documentation indicate precautions which must be taken to maintain safe operation of the instrument. Direct current (DC) Alternating current (AC) Equipment protected throughout by double insulation or reinforced insulation Off (supply) Both direct and alternating current On (supply) Three-phase alternating current Caution, risk of electric shock Earth (ground) terminal Protective conductor terminal Caution, risk of danger (refer to this manual for specific Warning or Caution information) Caution, hot surface Frame or chassis terminal Out position of a bi-stable push control Equipotentiality In position of a bi-stable push control U2941A Operating Guide III

General Safety Information WARNING Do not load the output terminals above the specified current limits. Do not use the device if it appears damaged or defective. Observe all markings on the device before establishing any connection. Do not operate the device in the presence of flammable gases or fumes. Do not install substitute parts or perform any unauthorized modification to the device. CAUTION Applying excessive voltage or overloading the device will cause irreversible damage to the circuitry. Use the device with the cables provided. Repair or service that is not covered in this manual should only be performed by qualified personnel. IV U2941A Operating Guide

Environmental Conditions This instrument is designed for indoor use and in an area with low condensation. The table below shows the general environmental requirements for this instrument. Environmental conditions Requirements Operating temperature 0 C to 50 C Operating humidity 20% to 85% RH noncondensing Storage temperature 20 C to 70 C Storage humidity 5% to 90% RH noncondensing U2941A Operating Guide V

Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC This instrument complies with the WEEE Directive (2002/96/EC) marking requirement. This affixed product label indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE directive Annex 1, this instrument is classified as a Monitoring and Control Instrument product. The affixed product label is shown below. Do not dispose in domestic household waste To return this unwanted instrument, contact your nearest Agilent Technologies, or visit: www.agilent.com/environment/product for more information. VI U2941A Operating Guide

Contents Introduction 1 Product at a Glance 3 Product outlook (with closed cover) 3 Product outlook (with opened cover) 4 Product dimensions 5 Standard Purchase Items 6 Orderable Items 7 Connection Cables 8 Socket Modules 10 Hardware Installation 12 Attaching the socket module 12 Mounting and wiring the DUT on the socket module 14 Software Installation 18 Hardware requirements 18 Software requirements 18 Installing the Parametric Measurement Manager 19 Product Specifications 20 Maintenance 21 U2941A Operating Guide VII

VIII U2941A Operating Guide

Introduction The Agilent U2941A parametric test fixture is designed for semiconductor device testing. The U2941A has three input channels and a common ground. You can select different types of socket modules for devices- under- test (DUTs) of various pin configurations. By mounting the suitable socket module on the U2941A, you are able to connect the DUTs to the U2722A USB modular source measure unit and U2751A USB modular switch matrix. You can connect the U2722A directly to the U2941A as shown in the following figure. BNC male outer contact (black wire) BNC male inner contact (red wire) CH1 1 S+ O+ S+ O+ G G O S O S U2722A U2941A U2941A Operating Guide 1

You also have the option to connect the U2722A via the U2751A to the U2941A as shown below. U2751A CH1 S+ O+ High Low Row 1 O S U2722A Low High Column 1 High Low Row 2 Column 2 High Low 1 BNC male outer contact (black wire) S+ O+ O S BNC male inner contact (red wire) U2941A For the information on the socket modules, refer to Socket Modules on page 10. To obtain more information on the U2722A and U2751A, refer to the U2722A USB Modular Source Measure Unit User s Guide and U2751A USB Modular Switch Matrix User s and Service Guide respectively. 2 U2941A Operating Guide

Product at a Glance Product outlook (with closed cover) Top view Input connectors Common ground connector Front view U2941A Operating Guide 3

Rear view Kensington lock Product outlook (with opened cover) Top view Terminals Socket module 4 U2941A Operating Guide

Product dimensions Top view 250 mm 53 mm 200 mm Front view 120 mm U2941A Operating Guide 5

Standard Purchase Items Verify that you have received the following items with your U2941A. If anything is missing or damaged, please contact the nearest Agilent Sales Office. Assembly Teflon plate 28- pin dual- in- line package socket module 0.1 inch universal socket module 0.075 inch universal socket module 0.05 inch universal socket module Four pin plug to pin plug cables (black) Four pin plug to pin plug cables (red) Four pin plug to pin plug cables (blue) Four pin plug to miniature clip cables (black) Four pin plug to miniature clip cables (red) Four pin plug to miniature clip cables (blue) Three BNC to two- wire cables, 1 m PCB jumper pins Agilent Parametric Measurement Manager CD (includes installation and operating guides) 6 U2941A Operating Guide

Orderable Items Module options Orderable part number Agilent part number Description U2941A-201 U2941-60002 Assembly Teflon plate U2941A-202 U2941-60003 28-pin dual-in-line package socket module U2941A-203 U2941-60004 0.1 inch universal socket module U2941A-204 U2941-60005 0.075 inch universal socket module U2941A-205 U2941-60006 0.05 inch universal socket module Cable options Orderable part number Agilent part number Description U2941A-101 U2941-20001 Four pin plug to pin plug cables (black) U2941A-102 U2941-20002 Four pin plug to pin plug cables (red) U2941A-103 U2941-20003 Four pin plug to pin plug cables (blue) U2941A-104 U2941-20004 Four pin plug to miniature clip cables (black) U2941A-105 U2941-20005 Four pin plug to miniature clip cables (red) U2941A-106 U2941-20006 Four pin plug to miniature clip cables (blue) U2941A-107 U2941-61601 Three BNC to two-wire cables, 1 m U2941A Operating Guide 7

Connection Cables BNC to two- wire cable (U2941-61601) 1 m 40 mm 6.4 mm Follow the procedure below to connect the BNC to two- wire cables from the U2722A to the U2941A input connectors. 1 Push the cables through the cable casing. Refer to the U2722A USB Modular Source Measure Unit User s Guide for the details. 2 Insert the black wire ends of the cables into the SENSE connectors of the U2722A. Insert the red wire ends into the OUTPUT connectors. 3 Push the cable casing towards the connector until it firmly envelops the connector. 4 Connect the BNC ends of the cables to the U2941A input connectors. To connect the U2722A via the U2751A to the U2941A, use the U2922A terminal block. Refer to the U2751A USB Modular Switch Matrix User s and Service Guide for details on the U2922A terminal block. 8 U2941A Operating Guide

Pin plug to pin plug cable Residual Resistance: 12 mω typical Black: U2941-20001 Red: U2941-20002 Blue: U2941-20003 4.5 mm 220 mm 4.5 mm 1 mm 1 mm Pin plug to miniature clip cable Residual Resistance: 12 mω typical Black: U2941-20004 Red: U2941-20005 Blue: U2941-20006 4.5 mm 200 mm 40.8 mm 1 mm U2941A Operating Guide 9

Socket Modules Assembly Teflon plate (U2941-60002) This insulation board has minimal leakage current which is suitable for extremely low current measurements, depending on the specifications of the cables and the U2722A. 42.8 mm 85.6 mm 83.6 mm 28- pin dual- in- line package (U2941-60003) This socket module has a 28- pin dual- in- line lever actuated zero insertion force (ZIF) socket. 42.8 mm 85.6 mm 83.6 mm 10 U2941A Operating Guide

Universal socket module 0.1 inch pitch: U2941-60004 0.075 inch pitch: U2941-60005 0.05 inch pitch: U2941-60006 This socket module is used for measurement of virtually any device such as components, DIP IC, CPGA package, or any small- scale circuit. 42.8 mm 85.6 mm 83.6 mm Jumper pin (U2941-20008) It is used with the universal socket module. 0.5 mm 8 mm U2941A Operating Guide 11

Hardware Installation Attaching the socket module After selecting the appropriate socket module for the DUT, install the socket module to the U2941A. The following figure shows the attachment of a socket module to the U2941A. Black plastic fasteners Socket module Use the following procedure to attach the socket module. NOTE Ensure that no voltage or current is applied to the U2941A when attaching the socket module. 1 Open the lid of the U2941A. 2 Check that the black plastic fasteners of the socket module are unlocked (pulled up). 3 Insert the socket module onto the U2941A. 4 Press the black plastic fasteners down to lock the socket module into place. 12 U2941A Operating Guide

Use the following procedure to remove the socket module from the U2941A. NOTE Ensure that no voltage or current is applied to the U2941A when removing the socket module. 1 Open the lid of the U2941A. 2 Remove the connection cables. 3 Pull up the black plastic fasteners on both sides of the socket module. 4 Lift the socket module from the U2941A. NOTE Always unlock the black plastic fasteners when the socket module is not in use. U2941A Operating Guide 13

Mounting and wiring the DUT on the socket module You can mount and wire the DUTs as described in the following. Non-Kelvin connections Connect the pin plug to pin plug cables between the Output terminals on the U2941A and the desired terminals on the socket module. Kelvin connections Connect a pin plug to pin plug cable between the Output terminal on the U2941A and the desired terminal on the socket module, and then connect a pin plug to miniature clip cable between the Sense terminal and DUT lead. The U2941A enables usage of the Kelvin connections for a maximum of three U2722A channels. The following figure shows an example of the Kelvin connection for channel 1. Connected to the O terminal of channel 1 Connected to the S+ terminal of channel 1 Connected to the O+ terminal of channel 1 Connected to the S terminal of channel 1 DUT 14 U2941A Operating Guide

You may also connect an additional pin plug to pin plug cable between the Sense terminal and the hole of the pin plug connected to the terminal as shown in the following figure. Connected to the S+ terminal Connected to the O terminal Connected to the O+ terminal Connected to the S terminal U2941A Operating Guide 15

Connections for a uniquely shaped device If there is no suitable socket module for a uniquely shaped DUT, you can connect the device by using the assembly Teflon plate or universal socket module as described in the following. Assembly Teflon plate Connect the terminals directly to the DUT on the assembly Teflon plate using the pin plug to miniature clip connection cables, as shown in the following figure. Ensure that the DUT is placed on the assembly Teflon plate. Connected to the O terminal Connected to the O+ terminal DUT Assembly Teflon plate 16 U2941A Operating Guide

Universal socket module The provided pitch sizes (0.1 inch, 0.075 inch, and 0.05 inch) offer you the flexibility to mount your DUT on the U2941A. You may either solder the DUT directly or insert an IC holder on the universal socket module. Open the casing of the socket module by removing the screws and use a wire to connect the DUT lead or IC holder lead to the jumper pin which is inserted on the socket module. The jumper pins connection at the bottom layer of the printed circuit board (PCB) is shown in the Bottom view figure. The other end of the jumper pins at the top layer of the PCB allows you to connect the terminals to the jumper pins using the pin plug to miniature clip cables as shown in the Top view figure. Top view Bottom view Pin plug to miniature clips Wires Jumper pins DUT Universal socket module NOTE Do not use the universal socket module for low leakage current measurements (<1 na). U2941A Operating Guide 17

Software Installation System requirements The Parametric Measurement Manager extends the capabilities of the U2941A by allowing you to perform various types of measurements efficiently. Before installing the Parametric Measurement Manager, ensure that your PC meets the following minimum system requirements for installation and operation. Hardware requirements Required hardware Processor Operating system Video Browser Available RAM Hard disk space Specification (Minimum) 1.6 GHz Pentium IV or higher One of the following Microsoft Windows versions: Windows XP Professional or Home Edition, Service Pack 1 or later Windows 2000 Professional, Service Pack 4 or later 1024 768 recommended Microsoft Internet Explorer 5.01 or higher (6.0 or higher recommended) 512 MB (1.0 GB or higher recommended) 1.0 GB free disk space at runtime Software requirements Required software Version (Minimum) Agilent IO Libraries Suite Version 15.0 [1] or higher Agilent VEE Runtime version 8.5 [2], patch 8.5.1 [2] Agilent Measurement Manager Version 1.6 [3] or higher Microsoft.NET Framework Version 1.1 and 2.0 [1] Available on the Agilent Automation-Ready CD. [2] Bundled with the Agilent Parametric Measurement Manager installer. [3] Bundled with the Agilent U2722A USB Modular Source Measure Unit or Agilent U2751A USB Modular Switch Matrix. 18 U2941A Operating Guide

Installing the Parametric Measurement Manager 1 Disconnect any instrument that is connected to your PC and close all other applications on your PC. 2 Insert the Agilent Parametric Measurement Manager CD into your CD- ROM drive. 3 If the installation menu does not appear after a few seconds, go to Start > Run and type <drive>:\ Autorun.exe where <drive> is your CD- ROM drive location. Click OK to begin installation. 4 Click Application on the Agilent Parametric Measurement Manager Installation Menu to begin the installation. 5 Click OK to begin the installation. 6 If you do not have any of the prerequisites installed, the InstallShield Wizard software prerequisite will appear. 7 Click OK to begin the installation of the listed missing prerequisites. 8 Once the above installation has completed, installation of the Parametric Measurement Manager will proceed as normal. 9 The Agilent Parametric Measurement Manager 1.0 InstallShield Wizard dialog will appear. Click Next to begin. 10 Read the License Agreement and select I accept the terms in the License Agreement to proceed. You may click Print to print a hardcopy of the Agilent License Terms for your reference. Click Next to proceed. 11 Fill in the Customer Information Form accordingly, and click Next. 12 Click Next to install to the specified folder or click Change to install to a different folder. 13 Click Install to begin the installation of the Parametric Measurement Manager. 14 Click Finish when the installation has completed. 15 A shortcut to the Parametric Measurement Manager will be created to your desktop. NOTE Refer to the Agilent U2941A Parametric Measurement Manager Application Software Help File for more information on the software features and functions. U2941A Operating Guide 19

Product Specifications The following specifications are valid for a temperature of 23 ±5 C and 85% relative humidity. ELECTRICAL SPECIFICATIONS Voltage rating Current rating 60 VDC 1 A ENVIRONMENTAL SPECIFICATIONS Operating temperature 0 C to 50 C Storage temperature 20 C to 70 C Operating humidity 20% to 85% RH noncondensing Storage humidity 5% to 90% RH noncondensing Altitude Up to 2000 m PHYSICAL SPECIFICATIONS Dimensions (W D H) Weight Warranty 250 mm 200 mm 120 mm 1.33 kg 3 months 20 U2941A Operating Guide

Maintenance To maintain high performance, the U2941A must be kept clean. Oil, perspiration, hair, dust, and dirt will degrade board insulation, which increases leakage current and decreases measurement accuracy. Agilent recommends the following cleaning procedures. Chassis, lid, inner plate, and socket modules 1 Ensure that voltage or current is not applied to the U2941A. 2 Remove all connection cables from the U2941A. 3 Using lint- free paper, gently wipe the chassis, lid, inner plate, and socket module. For any area that will not come clean, dip the lint- free paper into alcohol and wipe the area gently. Connection cables 1 Ensure that voltage or current is not applied to the U2941A. 2 Remove the connection cables from the U2941A. 3 Dip lint- free paper into alcohol and gently wipe the metal contacts of the connection cables. U2941A Operating Guide 21

22 U2941A Operating Guide

www.agilent.com Contact us To obtain service, warranty or technical assistance, contact us at the following phone or fax numbers: United States: (tel) 800 829 4444 (fax) 800 829 4433 Canada: (tel) 877 894 4414 (fax) 800 746 4866 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) 31 20 547 2111 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (080) 769 0800 (fax) (080) 769 0900 Latin America: (tel) (305) 269 7500 Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 6755 0042 Or visit Agilent World Wide Web at: www.agilent.com/find/assist Product specifications and descriptions in this document are subject to change without notice. Always refer to Agilent web site for the latest revision. Agilent Technologies, Inc., 2008 Printed in Malaysia First Edition, November 1, 2008 U2941-90001 Agilent Technologies