P USB 2.0 (Type B) Port - Programming - Online monitoring

Similar documents
P3-RS Remote Slave Module

P3-530 CPU. CPU Specifications. The P3-530 is a high-performance CPU for use with the Productivity3000 Programmable Automation Controller.

Do-more H2 Series PLC System Specifications

P3-RS Remote Slave. Remote Slave Specifications. The P3-RS is a full-featured, highperformance,

P1-540 CPU. CPU Specifications

General Specifications. P2-SCM Serial Communications

P3-SCM. General Specifications

P2-HSO High-Speed Isolated Sinking/Sourcing Output. Connector Specifications

TM221CE40R controller M IO relay Ethernet

TM241CEC24R controller M IO relay Ethernet CAN master

T1K MODBUS Base Controller Specifications

AC/DC Power Adapter: EA-AC. Expansion Assembly: EA-EXP-OPT. CF Card Interface Module: EA-CF-IF. 128 MB CompactFlash Memory Card: EA-FLASH-128MB

TM241CE40R controller M IO relay Ethernet

P2-04DAL-2 Analog Output. Removable Terminal Block Specifications

P2-16AD-2 Analog Input. Connector Specifications

TM241CE24U controller M IO transistor NPN Ethernet

TM241CE40R controller M IO relay Ethernet

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

TM221CE24T controller M IO transistor PNP Ethernet

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE40T controller M IO transistor PNP Ethernet

TM221ME16T controller M IO transistor PNP Ethernet

TM221ME32TK controller M IO transistor PNP Ethernet

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

FEATURES DESCRIPTION FEATURES

Description. 100MBit Ethernet Communication Module. 10Base-T Ethernet Module. Description

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE40R controller M IO relay Ethernet

TM251MESC controller M251 Ethernet CAN

TM241CE40R controller M IO relay Ethernet

TG Technical specifications

General Specifications. P2-8AD4DA-2 Analog Input/Output

TM221ME16RG. Main. Discrete output number. Discrete input current

TM221CE40T controller M IO transistor PNP Ethernet

P2-04AD Analog Input. Removable Terminal Block Specifications

TM221CE40R controller M IO relay Ethernet

TM241CE24T controller M IO transistor PNP Ethernet

C-more Micro-Graphic Panel Accessories

TM221CE24T. Main. Discrete output logic. Discrete input current. <= 7 relay output

Stride Industrial Ethernet Switches

TM221ME16T controller M IO transistor PNP Ethernet

PBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit

TM221M16TG controller M IO transistor PNP spring

TM221CE24R controller M IO relay Ethernet

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

P2-04DA Analog Output. Removable Terminal Block Specifications

TM251MESC controller M251 Ethernet CAN

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

TM221M32TK controller M IO transistor PNP

Installation and Setup

TM241C40U controller M IO transistor NPN

Stepping Systems. 4 components to make a complete system

TM241C24T controller M IO transistor PNP

Analog Voltage Combination Module

TM241C40R controller M IO relay

TM251MESE. Main. [Us] rated supply voltage. 14 with remote I/O architecture W with max number of I/O expansion module

LMC078CECS20T motion controller LMC078-20DIO transistor sercos compact Ethernet Canopen 24Vdc

Do-more H2 Series PLC Overview

DL05 CPU Specifications. Performance Contact execution (Boolean) µs Typical scan (1K Boolean) ms.

GS1 Series Introduction

-C5RS-LC RS232 EXTENDER

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

MGate MB3170/MB3270 Quick Installation Guide

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

MGate 4101-MB-PBS Series

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

MGate 5105-MB-EIP Series

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Optional Accessories 6 2

Communications Quick-Start Guide

Chapter. Modbus. In This Chapter...

Micro-Modular Programmable Controller

TM221M16R controller M IO relay

TM258LF42DT compact base M I/O - 24 V DC - CANopen

MGate 5102-PBM-PN Series

DL405 CPU COMPARISONS

Modular controllers CECX

C-more Operator Panels Overview

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

The C-more Family. Hardware Selection

Appendix D2-262 CPU. In This Appendix...

LMC058LF42 compact base - 42 I/O - 24 V DC supply

TM258LD42DT4L compact base M I/O - 24 V DC

RS-485 Products. ICP Electronics Australia Pty Ltd Communication Cards for PC/IPC P 2-1

Features and Benefits. Certifications

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

TM258LF42DT compact base M I/O - 24 V DC - CANopen

General Specifications. P2-08THM Analog Input

USER S MANUAL TP series

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Redundant System Redundant System P9-1-1

Serial/Ethernet Converter

Features and Benefits. Certifications

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

DIN Rail RTU 540CMD01 Data sheet

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Transcription:

P3-0 CPU Module Company Information Systems Overview P3-0 <---> The P3-0 is a full-featured, highperformance CPU. Features include a line x 10 character LCD and seven communications ports which support USB, Ethernet and serial devices. Each Productivity3000 system requires one CPU module mounted in the controller slot in the first base of the local base group. The CPU stores and executes the user s program. P3-0 Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox The system can be expanded with the P3-RS or P3-EX modules. The local, expansion, and remote I/O are assigned preconfigured or user-defined tagnames which can be easily referenced in the ladder logic program. USB 2.0 (Type B) Port - Programming - Online monitoring LCD - x 10 character - control buttons - User defined messages - User adjustable settings - PAC system errors / information Steppers/ Servos Motor Controls Proximity Photo 10/100 Mbps Ethernet Port - Programming - Online monitoring - Email (SMTP client) - Modbus TCP Client and Server Local Ethernet Network - GS Series drives - Remote IO USB 2.0 (Type A) Port - USB Flash Drive data logger - Project Transfer CPU Status Indicators RS-232 Serial Port (RJ12) - Modbus/ASCII (master or slave) peripheral device RS- Serial Port (TB Style) - Modbus/ASCII (master peripheral device or multiple slave devices) using the same protocol Limit Switches Encoders Current Pressure Temperature Pushbuttons/ Lights Process USB 2.0 (Type A) Port Local expansion bases (connect up to expansion) bases per base group Relays/ Timers Comm. UNLOCK Terminal Blocks & Wiring Power CPU Status Indicators PWR Green LED is illuminated when power is on RUN CPU Green LED is illuminated when CPU is in RUN mode Red LED is illuminated during power on reset, power down, or watch-dog time-out. Circuit Enclosures Tools Pneumatics Safety CPU Run/Stop Switch RUN position Executes user program, run-time edits possible STOP position Does not execute user program, normal program load position www.automationdirect.com/pacs Programmable Controllers e-29 Appendix Product Part #

P3-0 CPU Module LCD Message Display The CPU incorporates a line x 10 character LCD Display for system alarms and information or for displaying user-defined messages. LCD control buttons located beneath the display allow the user to navigate through a menu, and arrow buttons allow for configuration of time and date settings. For user-defined messages, the display is configured using the Productivity Suite Programming Software. An LCD Page instruction allows the user to program text into user-defined tags and display the messages based on the ladder execution. Specifications CPU Specifications User Memory Memory Type Retentive Memory Scan Time Display Communications; Integrated Ports Hardware Limits of System Instruction Types 0MB (Includes program, data and documention) Flash and Battery Backed RAM 100K 600µs (3K Boolean, 1K I/O) LCD, x10 characters, backlit, control buttons; LCD characters are x with a dot pitch of 0.mm; 2.2mm x 3.1mm USB IN: Programming, Monitoring, Debug, Firmware ETHERNET: (10/100Mbps Ethernet) Programming, Monitoring, Debug, Firmware, Email SMTP Client, Modbus TCP Master (6 Slaves) and Slave ( Masters) REMOTE I/O: (10/100Mbps Ethernet) 32 P3-RS Remote Base Groups, and 6 GS Drives USB OUT: (2.0) Data Logging or Project Transfer using SDCZ-20-A10 Pen Drive EXP I/O OUT: (2.0 Proprietary) P3-EX Local Expansion Bases RS-232: (RJ12, 1200-11.2k Baud) ASCII, Modbus RS-: Removable Terminal Included, (1200-11.2k Baud) ASCII, Modbus 33 Base Groups 1 Local (P3-0) + 32 Remote (P3-RS) Bases per Base Group 1 P3-0 or P3-RS + Expansion (P3-EX) 16 Bases Total 1 P3-0, 32 P3-RS, & 132 P3-EX 116,160 Hardware I/O Points (All 6-point I/O Modules) 6 GS Series Drives as Remote I/O Application Functions Array Functions Counters/Timers Communications Data Handling Drum Sequencers Math Functions PID Program Control String Functions System Functions Contacts Coil General Specifications Operating Temperature 0 to 60 C (32 to 10 F) Storage Temperature -20 to 0 C (- to 1 F) Humidity to 9% (non-condensing) Environmental Air No corrosive gases permitted Vibration IEC6006-2-6 (Test Fc) Shock IEC6006-2-2 (Test Ea) Heat Dissipation W Enclosure Type Open Equipment Agency Approvals UL0 file E132, Canada & USA UL160 file E200031, Canada & USA CE (EN61131-2*) This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or non-hazardous locations only. Module Location Controller slot in the local base in a Productivity3000 System EU Directive See the "EU Directive" topic in the Productivity3000 Help File. Information can also be obtained at: www.productivitypac.com Weight 260g (9 oz) *Meets EMC and Safety requirements. See the Declaration of Conformity for details. IMPTANT! Hot-Swapping Information Note: This device cannot be Hot Swapped. e-30 Programmable Controllers 1-00-633-00

P3-0 CPU Module Company Information Systems Overview Battery (Optional) A battery is included with the P3-0 CPU, but is not installed. The battery can be installed to retain the Time and Date along with any Tagname values that are set up as retentive. The battery is not needed for program backup. Step One: Press spring lock and swing battery compartment away from CPU. + Step Two: Insert battery and close compartment. Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Take care to insert battery behind metal tab. Battery (Optional) D2-BAT-1 Coin type, 3.0V Lithium battery, 60mA, battery number CR23 Proximity Photo Limit Switches Encoders CPU Installation Step One: Locate the two sockets next to the power supply; the CPU will be inserted into this location. Current Pressure Temperature Pushbuttons/ Lights Process Step Two: Insert the CPU at a angle into the notch located at the top of the base and rotate down until seated. Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Enclosures Step Three: Snap retaining tab into the locked position. Tools Pneumatics Safety Appendix WARNING: Explosion hazard Do not connect or disconnect connectors or operate switches while circuit is live unless the area is known to be non-hazardous. Do not hot swap. www.automationdirect.com/pacs Programmable Controllers e-31 Product Part #

P3-0 CPU Module - Communications Port Specifications The P3-0 CPU has seven communications ports. The following pages list specifications and pin-out diagrams for these ports. USB IN Port Used exclusively for connecting to a PC running the Productivity Suite programming software. USB Type B Slave Input Specifications Port Name USB IN Description Standard USB 2.0 Slave input for programming and online monitoring, with built-in surge protection. Not compatible with older full speed USB devices. Transfer Rate 0 Mbps Port Status LED Green LED is illuminated when LINK is established to programming software. Cables USB Type A to USB Type B: 3 ft. cable part # USB-CBL-AB3 6 ft. cable part # USB-CBL-AB6 10 ft. cable part # USB-CBL-AB10 1 ft. cable part # USB-CBL-AB1 1 2 3 Mating face of USB type B female 1 + 2 Data 3 +Data GND Ethernet Port RJ- style connector used for: Connection to a PC running the Productivity Suite programming software Modbus TCP Client connections (Modbus requests sent from the P3-0) Modbus TCP Server connections (Modbus requests received by the P3-0) Outgoing E-mail Remote I/O Port RJ- style connector used for connecting to a Remote I/O network consisting of P3-RS Remote Slaves and/or GS-EDRV100 units with GS drives. Crossover Cable TD+ 1 TD 2 /WHT RD+ 3 /WHT RD 6 /WHT RJ Patch (Straight-through) Cable TD+ 1 TD 2 RD+ 3 RD 6 RJ /WHT /WHT /WHT /WHT /WHT /WHT /WHT /WHT /WHT 1 TD+ 2 TD 3 RD+ 6 RD RJ 1 TD+ 2 TD 3 RD+ 6 RD RJ 1 10/BASE-T/100BASE-TX 1 2 3 6 -pin RJ Connector (PC) Ethernet Specifications Port Name ETHERNET REMOTE I/O Description Standard transformer isolated Ethernet port with built-in surge protection for programming, online monitoring, Email (SMTP client) and Modbus/TCP client/server connections (fixed IP or DHCP). Standard transformer isolated Ethernet port with built-in surge protection for connection to the P3-RS Remote I/O system. Supports 32 Remote I/O slaves and 6 GS Series drives. Transfer Rate Port Status LED Cables 10/100 Mbps Green LED illuminated when network LINK is established. Yellow LED is illuminated when port is active (ACT). Use a Patch (straight through) cable when a switch or hub is used. Use a Crossover cable (not offered by ADC) when a switch or hub is not used. e-32 Programmable Controllers 1-00-633-00

P3-0 CPU Module - Communications Company Information Systems Overview Port Specifications USB OUT Port Used for data logging or project transfers to and from a SDCZ-20-A10 Pen Drive. EXP I/O OUT Port USB Type A Master Output Specifications USB port used only for Expansion I/O connections to local P3-EX modules in a Productivity3000 base with I/O. Port Name USB OUT EXP I/O OUT Description Standard USB 2.0 Master output for connection to high-speed Flash drive (Sandisk SDCZ-20-A10) for data logging or program transfer with built-in surge protection. Proprietary USB 2.0 Master output for connection with up to four P3-EX local expansion bases, with built-in surge protection. Not compatible with older full speed USB devices. A 0.m male-to-female port extender cable is included to assist with Flash drive connection. Transfer Rate 0 Mbps Port Status Green LED is illuminated when LINK is established to connected device LED Cables None required USB Type A to USB Type B: 6 ft. cable part # P3-EX-CBL6 (included with P3-EX module) Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity 3 2 1 Mating face of USB type A female USB OUT 1 + 2 Data 3 + Data GND Photo Limit Switches Encoders Current RS-232 Port RJ-12 style connector used for: Modbus RTU Master connections Modbus RTU Slave connections ASCII Incoming and Outgoing communications Custom Protocol Incoming and Outgoing communications 6 1 6-pin RJ12 Female Modular Connector Pin # Signal 1 GND Logic Ground 2 +V 210 ma Maximum 3 RXD RS-232 Input TXD RS-232 Output RTS RS-232 Output 6 GND Logic Ground RS-232 Specifications Port Name RS-232 Description Non-isolated RS-232 DTE port connects the CPU as a Modbus/ASCII master or slave to a peripheral device. Includes ESD and built-in surge protection. Data Rates Selectable,1200, 200, 9600, 19200, 33600, 300, 600, and 11200. +V Cable Power Source TXD RXD RTS GND Maximum Output Load (TXD/RTS) EXP I/O OUT 210mA maximum at V, +/- %. Reverse polarity and overload protected. RS-232 Transmit output RS-232 Receive input Handshaking output for modem control. Logic ground 3K, 1,000pf 1 Reset 2 Data 3 + Data GND Minimum Output +/-V Voltage Swing Output Short +/-1mA Circuit Port Status LED Green LED is illuminated when active for TXD, RXD and RTS Cable Options D2-DSCBL USB-RS232 with D2-DSCBL FA-CABKIT FA-ISOCON for converting RS-232 to isolated RS- www.automationdirect.com/pacs Programmable Controllers e-33 Pressure Temperature Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Enclosures Tools Pneumatics Safety Appendix Product Part #

P3-0 CPU Module - Communications Port Specifications RS- Port A 3-pin removable terminal block used for: Modbus RTU Master connections Modbus RTU Slave connections ASCII Incoming and Outgoing communications Custom Protocol Incoming and Outgoing communications Removable connector included. Spare connectors available (part no. P3-RSCON). RS- Port Specifications Port Name RS- Description Non-isolated RS- port connects the CPU as a Modbus/ASCII master or slave to a peripheral device. Includes ESD/EFT protection and automatic echo cancellation when transmitter is active. Data Rates Selectable, 1200, 200, 9600, 19200, 33600, 300, 600, and 11200. TXD+/RXD+ RS- transceiver high TXD-/RXD- RS- transceiver low GND Logic ground Input Impedance 19K Maximum load 0 transceivers, 19K each, 60 termination Output Short Circuit +/- 20mA, thermal shut-down protection Electrostatic Discharge +/-KV per IEC1000--2 Electrical Fast Transient +/-2KV per IEC1000--. Minimum Differential Output Voltage 1.V with 60 load Fail safe inputs Logic high input state if inputs are unconnected Maximum Common Mode Voltage -.V to 12.V. Port Status LED Green LED illuminated when active for TXD and RXD Cable Options Recommend Belden #91 or equivalent Removable connector included. Spare connectors available (part no. P3-RSCON). G GND TXD-/RXD- + TXD+/RXD+ e-3 Programmable Controllers 1-00-633-00