UV-VIS Spectrophotometer

Similar documents
UV-VIS Spectrophotometer

Affordable Lab Technology

UV-6 Series Double Beam UV/Vis Spectrophotometers

UV / VIS SPECTROPHOTOMETER

Thermo Scientific GENESYS 10S Series UV-Visible Spectrophotometers

Precise & Affordable

Thermo Scientific GENESYS 30 Visible Spectrophotometer Legendary Reliability Unrivaled Usability

Thermo Scientific Evolution 60S UV-Visible Spectrophotometer

USER S MANUAL. SP-8001 UV-VIS Spectrophotometer. Metertech Inc. Version 1.08

Table of Contents 1. PRINCIPLE, APPLICATION AND FEATURES PRINCIPLE APPLICATION FEATURES SPECIFICATIONS AND ACCESSORIE

Cecil Dissolution 4/9/06 4:51 pm Page 1 DISSOLUTION SYSTEMS

Operating instructions - Cary 100 Bio UV-visible Spectrophotometer

Contents Safety.. 1 General. 1 Electrical.. 1 Warning 1 Working Principle 2 Unpacking Instructions 2 Specifications 3 Installation.. 3 Introduction..

Thermo Scientific Spectronic 200 Visible Spectrophotometer. The perfect tool. for routine measurements

Diving into a new dimension: Quality meets efficiency

MODELS 6500/6505 SPECTROPHOTOMETERS OPERATING MANUAL

7310 and 7315 Glossary of Icons. Operating Manual

Double Beam UV-VIS Spectrophotometer. Spectro 3366 plus EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

UV WinLab Software The Lambda Series

Operational Manual Spectrophotometer Model: SP-830 PLUS Metertech Inc.

TL6 Ultra Micro-volume Spectrophotometer

Model : LUV-300 Please read this manual carefully before using the instrument Labnics Equipment

Thermo Scientific GENESYS UV-Vis Spectrophotometer Accessories. Make the most of every sample

V-600 Operation. JASCO V-600 for Windows Software Manual

SP-VIS 200. Operating Manual. SP-VIS 200 Series UV-Vis Spectrophotometer. Instruments. User s Manual SP VIS Spectrum Instruments

now the only difficult thing about spectrophotometry is how to say it

Seized Drugs Operational Guidelines for the Shimadzu UV/VIS Comparative and Analytical Division

67 Series Spectrophotometer PC Software

Dissolution Automation: Off line Hybrid Systems

Libra S21 Visible and Libra S22 UV/Visible Spectrophotometers

NANO SPECTROPHOTOMETER

Jenway 6400/05 Spectrophotometer Service Manual

SoftWare. M.Wave Professional PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

UNICO 2100 SERIES SPECTROPHOTOMETER Model 2100 Spectrophotometer Model UV 2100 Spectrophotometer

SOLUTIONS RECERTIFICATION CALIBRATION AND UV/VIS REFERENCE MATERIALS. Photometric and Wavelength Accuracy Reference Material Set

AnalytPro. Analysis software. User Manual

GENESYS ON-BOARD SOFTWARE RELEASE NOTES

UV/VIS 8500 DOUBLE-BEAM SPECTROPHOTOMETER OPERATION MANUAL TECHCOMP

SPEKOL UV VIS Spectrophotometer

S800 Spectrawave Visible Diode Array Spectrophotometer

Hitachi U-2001 UV/Vis Spectrometer Updated November 14, 2017

NANOCOLOR VIS II and NANOCOLOR UV /VIS II

Libra S21 and S22 User Manual

Multiskan Sky Microplate Spectrophotometer

Provide Accurate Results. Operational Manual. Visible Spectrophotometer. SP-880 Mate. PC Software. Metertech Inc. Version 1.2.3

Model FP-6500 Spectrofluorometer Instruction Manual. FP-6500 for Windows

SPECTROMETERS USER MANUAL. Ver. 1.2_09/16. Making spectroscopy brighter

Ultrospec 10 User Manual. English. Deutsch. Français. Español. Italiano

Spectro-115E TM and Spectro-115U TM Spectroelectrochemical System. Operator s Manual

Compatible Visible Spectrophotometer T3/T3M. Operation Instruction Manual

powered by TAS Technology

What is IDS 1000 In-Situ Dissolution?

Smart. Simple. Easy. Hitachi Double-Beam Spectrophotometer

SPECTROPHOTOMETER UV-1600PC UV-VIS INSTRUCTION MANUAL

Spectrograph overview:

Microplate Readers INSTRUMENTS. Description Catalog # Description DAR800 SF2100 SF4700

Declaration of Conformity

The Libra Range of UV/Visible Spectrophotometers

Jenway 6310 Spectrophotometer Service Manual

Provide Accurate Results. Operational Manual. Visible Spectrophotometer SP-880. Metertech Inc. Version 1.10

The Libra Range of UV/Visible Spectrophotometers

Cary Fiber Optic Probes

Sepacore X10 / X50 system Technical data sheet

STANDARD SERIES MONOCHROMATOS FEATURES. Highly Customizable Modular Design. Two Configurable Input and Output Ports

Technical Overview. Introduction

Каталог спектрофотометров

The Libra Range of UV/Visible Spectrophotometers

C101-E137 TALK LETTER. Vol. 14

Operation Manual for UV Spectrometer SPECTRO-UV3 Series

Product Specifications and Usage Information P4300 Evolution 220 Spectrophotometer

Moisture Analyzers EM 120-HR

FULLY AUTOMATED FIBRE OPTIC INSITU DISSOLUTION TESTING

Light Sources opmaak.indd :32:50

6 x 6 Peltier-Thermostatted Multicell Holder Series II Accessory

CH142 Spring Spectrophotometers with Vernier Data Acquisition Software

User Manual. HP 8453E UV-visible Spectroscopy System

Technical Specifications

that runs under the Microsoft

Mercury Tracker-3000 XS

FTIR Spectrophotometer. analytical instruments for science

Chapter 3. Experimental Procedure

Agilent 8453 UV-visible Spectroscopy System. Installing Your UV-visible Spectroscopy System

Agilent 1260 Infinity Diode Array Detector

Dissolution Testing PT DT70

Photo Emission Tech., Inc. 760 Calle Plano, Camarillo, CA USA Tel: (805) Fax: (805)

Jasco FP-6500 Spectrofluorimeter Updated November 14, 2017

Libra S2 Colorimeter User Manual. English. Deutsch. Français. Español. Italiano

Dissolution Automation: Off line Systems

Biolight Luminescence System GmbH ( SOFTWARE MANUAL. BioLight Studio Software. Version

Specifications August 2011

BYK-mac. Total color impression of effect finishes. Ergonomic design and easy operation. Reliable readings at any time

Microplate Absorbance Reader Labtech LT-4500

ELECTRONIC CATALOGUE CUSTOMER S AMENDMENTS ISSUE 04 JULY 2010 Page 1 of 4 pages

The Autopol VI Automatic Polarimeter

Model KBW 720 Growth chambers with light

Standard Operating Procedure for the Horiba FluroMax-4

ANALYTICAL SYSTEMS. L3320 Autosampler with excellent accuracy and linearity. System configuration examples

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Module

Laboratory Line. Multipurpose Laboratory Equipment. > For all kinds of laboratories > Robust and versatile > Equipment in HUMAN quality

SPECTROPHOTOMETER V-1200 INSTRUCTION MANUAL

Transcription:

T60 UV-VIS Spectrophotometer LOW STRAY LIGHT EXCELLENT STABILITY EASILY UPDATED MANY APPLICATIONS LOW COST HIGH QUALITY SMALL FOOTPRINT USER FRIENDLY SOFTWARE T60 UV-VIS Spectrophotometer

1/2 PG INSTRUMENTS LIMITED has developed its latest Spectrophotometer, the T60, based on advanced technology. The advanced modular design ensures outstanding performance combined with quality and an excellent specification. The T60 provides the functionality of an advanced instrument, at an affordable price. The superior flexibility, high level of automation and user friendly software, backed up with excellent service makes the system the "Professionals" Choice. PG INSTRUMENTS LIMITED

Low stray light Stray light below 0.05% The advanced optical system ensures very low stray light High Quality optic reliable analytical Stray light is controlled by a very low noise electronic circuit T60 UV-VIS Spectrophotometer

3/4 Excellent stability Superior material makes it stable and durable A micro-step motor positions the grating very precisely. This motor is free from maintenance. Deuterium and Tungsten lamps are used as the light source. y optical components ensure accurate lytical data The monochromator is totally sealed and the optical surfaces are protected with a silicon dioxide membrane. The Spectrophotometer shell is made from an environmentally friendly non corrosive material. PG INSTRUMENTS LIMITED

Hardware and Software easily updated Pre-programmed application cards to perform analysis such as DNA/Protein, photometric, kinetics etc can be easily inserted by the user. The cell compartment is easily opened to allow other accessories to be used. System is easily interfaced to a PC via a standard RS232 interface. Can be easily interfaced to many different printers. The user can easily receive program updates from the PG Instruments internet site. T60 UV-VIS Spectrophotometer

5/6 User friendly design Offers ease of use and simple maintenance FULL AUTOMATION Automatic wavelength positioning, lamp change over, wavelength calibration, motorised sample changer etc. FAST SCAN The speed of the wavelength drive is up to 7000nm/min and the speed of the wavelength scan is up to 2500nm/min. Built in Cell Holder Storage The cell holder on one side of the sample compartment allows for easy access. Cleanable Dust Filter The Dust Filter ensures the internal parts of the instrument remain contamination free. Automatic Lamp Usage detection system The user allows to check the lamp usage information. For example, if the tungsten lamp has operated for 201 hours and the deuterium lamp for 197 hours, it will display as following. Simple Maintenance The retaining mechanism at the bottom and the back of the instrument make maintenance a simple process. PG INSTRUMENTS LIMITED

Analysis with UVWin Software Powerful Functions with user friendly operation Four regular functions 3D Presentation 3D Presentation by combining multiple spectrum Spectra can be fully and easily manipulated Peak Picking Graphics printout Photometric measurement Kinetics measurement DNA/Protein Analysis Measurement of absorbance ratios at 260nm and 230nm, at 260nm and 280nm, and at custom defined wavelengths Background correction using absorbance at 320nm (Optional) Absorbance ratio calculation for user selected wavelengths Concentration calculation using arbitrary factors when selecting custom defined wavelengths Quantitative measurement Spectrum scan T60 UV-VIS Spectrophotometer

7/8 Software packages for various industries Gene analysis Drug analysis Pesticide analysis Foods analysis Environmental analysis DNA/Protein analysis software package Pharmacopoeia software package Pesticide residues software package Foods analysis software package Environmental analysis with environmental software package Log Record Automatically records each operator s usage Reliable database format to save the log The administrator can sort the log records and perform many other useful tasks Software Conforming to GLP Multi-user management Log record Quality control Printout record Binary File Save Binary format to save measurement data Binary format improve the data secrecy Save the disk space Multi-User Management Allows the administrator to create users and groups with different privileges Access control by user ID and password Quality Control Monitor the data according to the user s setup The system will take corrective measures if the data is out of range Data Printout Share data with other software The results can be saved in Microsoft Word Microsoft Excel Text Printout Records Printout measurement results Personal settings for the report format Print preview

Specifications Optical system Wavelength range Wavelength accuracy Wavelength reproducibility Spectral bandwidth Stray light Photometric range Photometric accuracy Photometric reproducibility Baseline flatness Noise Baseline stability UV-Visible The split beam monitoring ratio system 190 1100nm 1nm 0.2nm 2nm 0.05%T -0.3 3Abs 0.002Abs(0 0.5A) 0.004Abs(0.5 1A) 0.3%T(0 100%T) 0.001A(0 0.5A) 0.002A(0.5 1A) 0.15%T(0 100%T) 0.002A (200 1000nm) 0.001A (500nm,p-p), half an hour warm-up 0.001A/h (500nm,0Abs), 2hr warm-up Visible The split beam monitoring ratio system 325 1100nm 2nm 0.4nm 2nm 0.1%T -0.3 3A 0.002A (0 0.5A) 0.004A (0.5 1A) 0.3%T(0 100%T) 0.001A 0 0.5A 0.002A 0.5 1A 0.15%T(0 100%T) 0.002A (325 1000nm) 0.001A (500nm,p-p), half an hour warm-up 0.002A/h (500nm,0Abs), 2hr warm-up Performance Photometric measurement Program card(dna/protein analysis, Quantitative measurement, Photometric measurement, Multi-wavelength analysis) Life check for Tungsten-Halogen lamp and Deuterium lamp Auto 8-cell changer Backlight digital LCD Mini-printer, HP Deskjet printer and laserjet printer,via parallel port PC interface via RS232 link Photometric measurement Quantitative measurement LCD digital display Mini-printer, HP Deskjet printer and laserjet printer,via parallel port PC interface via RS232 link T60 UV-VIS Spectrophotometer

9/10 Optional accessories UVWIN5 UV/Win 5 Software & RS232Communication Cable PC161-1 T60U Quantitative PCMCIA Program Card PC161-4 T60U DNA/Protein PCMCIA Program Card PC161-2 T60U Multi Wavelength PCMCIA Program Card Program Card Sipper Pump PC161-3 T60U Scanning and Kinetics PCMCIA Program Card PS16-2 T60 Sipper Pump Accessory (Pump, Tubing, Cassette, Front Panel, Flow Cell) CH16-1 T60 Constant Temperature Holder Constant-temperature Cell Holder Adjustable Angle Solid Sample Holder DS16-1 T60 Adjustable Angle Solid Sample Holder 21601-00 T60 Universal 5 Position 5-100mm Cell Changer Motorised Assembly 21603-00 T60 8 Position 10mm Path length Cell Changer Motorised Assembly TR16-2 T60 Single Position Cell 5-100mm / Test Tube HolMder Long Pathlength 5-cell Holder Automatic 8-cell Holder TR16-1 T60 Single Position Variable 13-16mm Test Tube Holder PTC-2 Peltier Module UP16-1 Micro Printer Accessory (UP) Test Tube Holder Peltier Dimensions Width Depth Height = 476(mm) 362(mm) 225(mm) Weight = 11 kg Micro Printer

2008-12 - b