MEV Limited USB232/485 INSTRUCTION MANUAL

Similar documents
PCI247H 2-9H 2 SERIES

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M

EasySYNC Ltd. USB to Serial Converters Manual

EZL-200F Application Notes (003) Serial Interface (RS232/RS422/RS485)

EasySYNC Ltd. USB to Serial Converters Manual

3.1 I-7560 Pin Assignment and Specifications: Introduction

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

PCI Express 4-Port Industrial Serial I/O Cards

MODEL USB-FLEXCOM4. USB to Four RS-232/422/485 Serial Ports and MODEL USB-COM232-4A USB to Four RS-232 Serial Ports USER MANUAL

CS485. User s Manual. Version ZYPEX, Inc.

EX & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card

Product Manual. USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4

MODEL 485HF9 PLUG-IN SIGNAL LEVEL ADAPTOR 9 PIN RS-232 TO RS-422/485

MODELS 485HF25/M25. PLUG-IN SIGNAL LEVEL ADAPTOR RS-232 to RS-422/485

General Specifications. P2-SCM Serial Communications

BeagleBone Black USB Expansion RS232 Module Cape Coolgear, Inc. Version 1.1 September 2017 Model Number:

ELAN DIGITAL SYSTEMS LTD. CF428 COMPACT FLASH CF+ CARD USER S GUIDE

USB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual

W&T Manual Interface modules W&T

MODEL USB-COM-2SM USER MANUAL

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

8S RS232/422/485 Combo to USB2.0 Module Box Installation Guide

Introduction & Specifications of Hi-Speed USB to Serial Adapters

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US

Manual Industry Interfaces

Future Technology Devices International Ltd. USB to RS422 Serial Converter Cable. Datasheet

Installation Guide of Hi-Speed USB to Octal RS-232/422/485 Adapter

MODEL USB-FLEXCOM4 USB to Four RS-232/422/485 Serial Ports. and. MODEL USB-COM232-4A USB to Four RS-232 Serial Ports USER MANUAL

IC232 PC- CARD USER S GUIDE

Serial Communication Converters & Adapters Instruction Manual

User s Manual INT131

MEC-COM-M134. User s Manual

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

PCI Express 16-Port Serial I/O Cards

ICD200A Quick Start Guide. Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas.

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

Product Manual. 2 Port USB to RS-422 /485 Optical Isolated Adapter. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-2COMi-Si-M

PC231/PC241 EIGHT CHANNEL SERIAL COMMUNICATIONS BOARD WITH ISOLATION OPTION

Sender Receiver Sender

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

OnCell G3100 Series Quick Installation Guide

Preliminary. PACKAGE - 28-pin MLP (5mm X 5mm) Example Circuit Diagram CP V. 48MHz Oscillator. USB Function Controller 512B EEPROM

TRP-C08M. USB To 4 RS232/422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.0

P3-SCM. General Specifications

Model:UT-8814 USB/RS-232 Commercial interface converter. Instruction Manual

Installation Guide of Hi-Speed USB to Industrial I/O Adapter

NMEA 2000 to NMEA 0183 Gateway NGW-1-ISO. Installation Manual

PCIe Card Selection Guide. PCIe-CAN Card. PCIe-COM Card. Taiwan Pulse Motion Co.,Ltd. Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T

SUNIX DEL2S00PL meets the PCI Express Base Specification Revision 2.0. It is compatible with PCI

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

Xtreme/104. PC/104 Serial Communications. User Manual

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date:

GNS-MC35iT, GNS-MC35iU Terminals datasheet

PCIe-400 USER S MANUAL

DATA CONNECT ENTERPRISE

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

BOARD LEVEL PRODUCTS GPIB<->RS-422/RS-485 INTERFACE BOARD

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

Installation Guide of Hi-Speed USB-to-Optically Isolated RS-422/485 Adapter

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

TRP-C08S. USB To 1* RS232 and 1*RS422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.2

RS485 3 click. How does it work? PID: MIKROE-2821

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company

User s Manual Printed Sep Rev 1.2

converter Tel: Fax:

USB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual. Features and Specifications. Power Supply

Installation Guide of Hi-Speed USB to Industrial Single RS-422/485 Adapter

EMERALD-MM-8P. 8-Channel Software Programmable Protocol. Serial Port PC/104 TM Module. User Manual V1.20

MAP/950 SERIAL I/O CARD INSTALLATION MANUAL

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

SeaLINK+8/USB. Sealevel Systems, Inc 155 Technology Place P.O. Box 830 Liberty, SC USA

CONNECT WITH RELIABILITY. USB-to-Serial Adapter User s Manual

SERIAL I/O PRODUCTS SEALEVEL I/O FAMILY NEW PRODUCT. RS-422/485 Serial I/O. RS-422/485 Specification

Integrity Instruments Application Notes. Release 1

User Guide. Date Apr BlueEva+C11/G2. Stollmann. E + V GmbH. User Guide

Serial Interface Modules TTL to RS232/RS485/RS422

Introduction. General Ratings

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

Introduction & Specifications of Hi-Speed USB to Industrial Dual Ports RS-422/485 Adapter

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

Korenix JetCard Series Multiport Serial Card/Ethernet Switch Card User s Manual

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

ELAN DIGITAL SYSTEMS LTD.

HomeVision-Serial. Add-On Card. Installation and Operation Manual

USB-2COM-BB USER S MANUAL

RTU560 Remote Terminal Unit Connections and Settings

Integrity Instruments

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

TRP-C08S. USB to 1 RS232 and 1 RS422/485 Isolated Converter. User s Manual

For technical support and service, please visit our support website at:

Manual Fiber Optic Interfaces

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

RTU560 Connections and Settings DIN Rail RTU 560CIG10

PCIEMODBOX232 RS232 to PCI Module Box Introduction

ELAN DIGITAL SYSTEMS LTD. CF232 COMPACT FLASH CF+ CARD USER S GUIDE

USB MOD1 - USB Plug and Play Serial Development Module

SCB-C08 USB to RS232/422/485 Converter

Transcription:

MEV Limited USB232/485 INSTRUCTION MANUAL USB TO RS232 / RS485 SERIAL COMMUNICATIONS INTERFACE WITH ISOLATION OPTION Issue 5

LIST OF CONTENTS 1 INTRODUCTION 1 1.1 The Products Described in this Manual 1 1.2 Features of the USB232/485 Series of Data Communications Interfaces 1 1.3 General Description 2 1.3.1 Enhanced Features 3 1.4 What the Package Contains 3 1.4.1 Contacting MEV Limited for Technical Support or Service 3 1.4.2 Technical Support 3 2 GETTING STARTED 4 2.1 General Information 4 2.2 Installing the Interface 4 2.2.1 Windows 98/ME Installation 4 2.2.2 Windows 2000/XP Installation 4 2.2.3 Linux Installation 4 2.3 USB232/485 Configuration Jumper Settings 5 2.3.1 RS-485 Full Duplex / Half Duplex Operation 5 2.3.1.1 Jumper Selection For Full Duplex Operation 5 2.3.1.2 Jumper Selection For Half Duplex Operation 5 2.3.1.3 Selection of Local Echo On/Off in Half Duplex Operation 5 2.3.2 Transmission Line Termination 6 2.3.2.1 Termination Resistors for RS-422/485 Receivers 6 2.3.3 Jumper Factory Settings Summary 6 2.4 Application Software 7 2.4.1 Installation Testing 7 3 MAKING THE CONNECTIONS 8 3.1 External Connections 8 3.1.1 USB Connector 8 3.1.2 RS-232 9 way Port 8 3.1.3 RS-422/485 9 way Port 9 3.2 The Ground Connections 9 3.2.1 USB 232 Ground Connections 9 3.2.2 USB485 Ground Connections 10 3.2.3 USB485i Ground Connections 10 3.3 Choice of Cable 10 4 PROGRAMMING 11 4.1 Programming with Windows 98, ME, 2000 and XP Device drivers. 11 4.2 Half Duplex Transmission Turnaround 11 Appendix A - TECHNICAL SPECIFICATIONS i A.1 HARDWARE SPECIFICATION i A.1.1 USB i A.1.1.1 Series B connector i A.1.1.2 Power (VBus) i A.1.1.3 Input Levels i A.1.1.4 Output Levels i A.1.2 USB232 RS-232 Port ii A.1.2.1 9 way Connector ii

A.1.2.2 Configuration ii A.1.2.3 Rx Voltage Levels ii A.1.2.4 Tx Voltage Levels ii A.1.2.5 Data Rate ii A.1.2.6 I/O Protection ii A.1.2.7 ESD Protection ii A.1.3 USB485 and USB485i RS-422/485 Port iii A.1.3.1 9 way Connector iii A.1.3.2 Rx Voltage Levels iii A.1.3.3 Rx I/P Termination iii A.1.3.4 Tx Voltage Levels iii A.1.3.5 Tx O/P Protection iii A.1.3.6 I/O Isolation iii A.1.3.7 ESD Protection iv A.1.3.8 Modes iv A.1.3.9 Transmit Turnaround iv A.1.4 UART iv A.1.4.1 Baud Rates iv A.1.4.2 Data Bits iv A.1.4.3 Stop Bits iv A.1.4.4 Parity iv A.1.5 PC INTERFACE iv A.1.5.1 Compatibility iv A.1.5.2 Host resources iv A.1.5.3 USB Frame Rate v A.1.5.4 USB packet size v A.2 SOFTWARE v A.3 ENVIRONMENTAL CONDITIONS v A.3.1 Specific conditions v A.3.1.1 Dimensions v A.3.1.2 Temperature Range v A.3.1.3 Power Requirements v A.3.1.4 Dissipation v A.3.1.5 Electro Magnetic Compatibility v LIST OF FIGURES Figure 2.1 Jumper Settings For Full Duplex Operation 5 Figure 2.2 Jumper settings for Half Duplex Operation 5 Figure 2.3 Jumper settings for Local Echo On/Off in Half Duplex Operation 5 Figure 2.4 Jumper Settings for Termination Resistor Selection 6 Figure 2.5 Factory Jumper Setting Summary 6 Figure 3.1 USB Connector Termination Assignment 8 Figure 3.2 RS-232 9 way Port Pin Designations 8 Figure 3.3 RS-422/485 Amplicon Standard Port Pin Designations 9

1 INTRODUCTION The USB232 and USB485 serial communications interfaces are a range of USB peripherals that provide legacy RS232 or RS485 serial communication interfaces to computers with USB support. 1.1 The Products Described in this Manual There are three variants of USB232/485. Each supports a single serial communications interface that appears to operating system as a standard serial port. USB232 USB485 USB485i A non-isolated RS232 interface. A non-isolated RS485 interface. An isolated RS485 serial interface. 1.2 Features of the USB232/485 Series of Data Communications Interfaces Each of the USB232/485 series of interfaces is designed to meet stringent performance requirements and ease of use while maintaining compatibility with standard serial communications boards. USB 1.1 specification compliant Windows 98, ME, 2000, XP and Linux compatible Data rates selectable up to 920 k baud (RS232) and 1,500 k baud (RS485) FIFO modes supporting a 384 character receive buffer and 128 byte transmit buffers Three point isolated serial communications on isolated versions Full Duplex, Half Duplex, Multi-drop applications RS485 transmitter enabled automatically in Half Duplex mode Full specification signal levels Implementation of all RS-232 primary control lines Low power consumption Page 1

1.3 General Description The USB232/485 are advanced RS232 / RS485 serial communications interfaces suitable for any IBM PC or compatible computer that supports USB 1.1. The RS485 ports have a link selectable Half Duplex mode that causes the transmit buffer to be enabled automatically, by the UART, whenever data is waiting to be sent from the UART Transmit buffer. All models are supported by 3 rd party Windows and Linux drivers. Microsoft Windows drivers are distributed on the CD that accompanies this product, and are also available on the MEV website at http://www.mev.co.uk/download.htm. The Linux drivers are available as standard as part of the 2.4.0 kernel and above. These drivers are a superset of the Microsoft serial drivers and allow the devices to operate as standard serial ports. These drivers also allow the advanced features of the devices to be fully utilised by the application software. There are three models available in the range. USB232 USB485 USB485i provides a 9 pin RS-232 port provides a 9 pin RS-422/485 port, jumper configurable to be half-duplex. provides an isolated 9 pin RS-422/485 port, jumper configurable to be halfduplex. The USB485i is designed to isolate the serial communications from the computer power. The design is such that it will sustain common mode voltages up to 75Vdc, which is outside of the low voltage directive (73/23/EEC). However in fault conditions they are protected to sustain common mode voltages up to peaks of 1KVdc. It provides isolation of the data and can be used in serial communications systems where high integrity data transmission and reception are required in an electrically severe environment. Each interface consists of a small self powered unit that connects to the USB interface via a standard USB interface cable and one serial port designed to meet one of the following standards: RS-232 full duplex serial port furnished with a 9 pin D-type male connector conforming to IBM practice. The port is fully configured with two data, six control I/O lines and one signal return. RS485 full duplex, half-duplex, multi-drop operation or RS422 full duplex without RTS- CTS control lines. Depending on the application, RS485 or RS422 operation is selected by making the appropriate connections. Each RS422 / 485 port is furnished with a 9 pin D-type male connector. Each interface takes up to one unit load, 100mA, from the PC USB interface. Page 2

1.3.1 Enhanced Features The USB232 supports data rates up to 920k baud. The USB485 and 485i support data rates up to 1.5M Baud. There is a 384 byte receive FIFO buffer and 128 byte transmit FIFO buffer associated with each port. This allows the processor to service the ports in a timely manner over the USB bus. The range has another special feature if you have an RS485 Half Duplex or Multi-drop Application. There is a link selectable Half-Duplex mode. In this mode the RS485 transmit buffer is enabled automatically, by the UART, whenever data is waiting to be sent in the UART Transmit buffer. This feature makes efficient multi-drop communication simple to implement by removing the burden of the Transmit buffer enable control from the software. 1.4 What the Package Contains The package as delivered contains: 1. The USB serial interface as ordered, in a protective bag. The model will be one of the following, and is identified by the type number printed on the PCB. USB232 USB485 USB485i USB to RS-232 Serial Communications Controller USB to RS-422/485 Serial Communications Controller USB to RS-422/485 Serial Communications Controller with I/O signal isolation 2. The included distribution software and manual on CD 3. Any additional accessories (mating connectors, software etc.) may be packed separately. 1.4.1 Contacting MEV Limited for Technical Support or Service The USB Series of interfaces are designed and manufactured by MEV Ltd and maintenance is available throughout the supported life of the product. 1.4.2 Technical Support Should the device appear defective, please check the information in this manual and any 'Help' or 'READ.ME' files appropriate to the program in use to ensure that the product is being correctly applied. If an application problem persists, please request Technical Support in one of the following ways: Telephone: UK 0161 477 1898 International +44 161 477 1898 Fax: UK 0161 718 3587 International +44 161 718 3587 Email: Web: cooperd@mev.co.uk www.mev.co.uk Page 3

2 GETTING STARTED 2.1 General Information All of the USB232/485 series are Plug and Play and come complete with all the software to install and operate the device in any USB version 1.1 compliant host PC running under Windows or Linux and allow execution of normal serial communications programs. Each device connects to the USB port with a standard USB Type B cable and does not need an external power supply. When installing one or more USB232/485 Series Data Communications interfaces, ensure that the host computer has sufficient capacity. The USB 1.1 standard has support for up to 127 physical devices attached to the bus, however the bandwidth and performance of the port will be affected by bus loading, especially if high bandwidth devices are used as well. The USB serial communications interfaces are suitable for use in any PC compatible computer that can provide a single USB 1.1 compliant interface. The computer must run under a one of the following operating systems: Windows 98, Windows ME, Windows 2000, Windows XP or Linux. 2.2 Installing the Interface Connect a USB Type B cable between the USB232/485 serial communications device and the host computer. The USB232/485 interfaces are Plug and Play devices. The installation software supplied will handle all configuration of the device. When the device is physically connected to the PC the Windows operating system will discover new hardware. From then on respond to the questions asked. When prompted for a disk use the disk supplied. Exact installation instructions are operating system dependent. 2.2.1 Windows 98/ME Installation Please refer to Installing FT8U232/245 devices under Windows 98 (AN232-03.pdf) which can be found on the associated CD or at http://www.mev.co.uk/download.htm. 2.2.2 Windows 2000/XP Installation Please refer to Installing FT8U232/245 devices under Windows 2000 (AN232-05.pdf) which can be found on the associated CD or at http://www.mev.co.uk/download.htm. 2.2.3 Linux Installation Linux Drivers for FT8U232/485 devices have been added to Linux Kernel 2.4.0 and above. The devices will be detected automatically and will typically be configured as /dev/ttyusbn devices. Page 4

2.3 USB232/485 Configuration Jumper Settings Most configuration settings on the USB232/485 are performed by the plug and play installation program. However the USB485 and USB485i have some jumpers and these need to be set before connecting the unit to the host. The functions of the jumpers on the USB485 and USB485i control whether the unit operates in Full Duplex or Half Duplex mode and whether or not the RS485 port is terminated. The USB232 does not have jumpers. 2.3.1 RS-485 Full Duplex / Half Duplex Operation The RS-485 port on a USB485 or USB485i can be used in either full duplex (simultaneous transmission and reception over two independent wire pairs) or half duplex (sequential transmission or reception over a single wire pair). In full duplex operation the transmitter can be left in its enabled state at all times. In half duplex receive operation, the transmitter must be disabled by switching to its high impedance state. This allows reception of data over the same serial lines. 2.3.1.1 Jumper Selection For Full Duplex Operation Link JP2 2-3 JP3 2-3 JP4 1-2 JP5 2-3 Function Full Duplex (4 wire) operation Receiver enabled when device is awake Transmitter enabled when device awake Figure 2.1 Jumper Settings For Full Duplex Operation 2.3.1.2 Jumper Selection For Half Duplex Operation Link Function JP2 1-2 JP3 1-2 2 wire operation TxA is connected to RxA and TxB is connected to RxB JP5 1-2 Transmitter only enabled when device is transmitting Figure 2.2 Jumper settings for Half Duplex Operation 2.3.1.3 Selection of Local Echo On/Off in Half Duplex Operation Normally in half duplex operation it is not desirable to see the characters being transmitted. JP4 controls the operation of the receiver during half-duplex operation. Link JP4 2-3 JP4 1-2 Function LOCAL ECHO OFF Receiver disabled when device is transmitting LOCAL ECHO ON Receiver enabled when device is transmitting Figure 2.3 Jumper settings for Local Echo On/Off in Half Duplex Operation Page 5

2.3.2 Transmission Line Termination 2.3.2.1 Termination Resistors for RS-422/485 Receivers Operation of RS-422/485 systems requires that the lines be terminated at the final receiver. The simplest termination is by a line-to-line resistor, and provision is made to connect this 120Ω terminator on the data of each RS-422/485 channel. The data input terminator resistors can be configured using jumper, JP1, which is factory fitted. Link JP1 1-2 JP1 2-3 Function Data line is terminated Data line is NOT terminated Figure 2.4 Jumper Settings for Termination Resistor Selection Correct termination is built into the RS-232 receivers. 2.3.3 Jumper Factory Settings Summary The USB485 and USB485i interfaces can be reset to their factory defaults by re-configuring the device according to the following tables. These settings allow the device to be used in full or half duplex with local echo without changing the jumpers. Link JP1 1-2 JP2 2-3 JP3 2-3 JP4 1-2 JP5 1-2 Function Data Line Terminated Full Duplex (4 wire) operation Receiver enabled when device is awake Transmitter only enabled when device is transmitting Figure 2.5 Factory Jumper Setting Summary Page 6

2.4 Application Software The HyperTerminal program supplied with Windows is compatible with the USB232/485 interfaces and is useful for testing and operation on COM1 to COM4 channels. The device will operate in conjunction with all commercially available communications and data acquisition packages that support Windows 98, ME, 2000 & XP serial ports. The device will operate with DOS programs that use the standard serial ports and will run inside a DOS window under Windows 98, ME, 2000 or XP. Install the required application software in accordance with the vendor s instructions, assigning communications to the required COM port. Source code and executable versions of a simple terminal application for Windows and Linux written in Delphi/Kylix is available for download from the MEV web site http://www.mev.co.uk/download.htm. 2.4.1 Installation Testing Many applications packages include a self-test feature, and when the hardware and software have been satisfactorily installed, any such test should be performed to check correct operation. Page 7

3 MAKING THE CONNECTIONS This chapter describes the signal and control connections that the user must make between the USB232/485 interfaces and any external serial communications devices. 3.1 External Connections 3.1.1 USB Connector Connection to the USB port is made using a standard type B cable. Contact Number Signal Name Typical Wiring Assignment 1 VBUS Red 2 D- White 3 D+ Green 4 GND Black Shell Shield Drain Wire Figure 3.1 USB Connector Termination Assignment 3.1.2 RS-232 9 way Port Connections to the RS-232 are made via 9 pin D type connectors on the interface. The onboard connectors are male and the mating sockets are available as accessories. Provision is made for securing by screw jacks. The 9 pin D connector pin-out conforms to the industry standard and will support commercially available cables and adapters. Reference Signal Ground (SG) Data Terminal Ready (DTR) Transmitted Data (TXD) Received Data (RXD) Data Carrier Detect (DCD) 5 9 4 8 3 7 2 6 1 Ring Indicator (RI) Clear To Send (CTS) Request To Send (RTS) Data Set Ready (DSR) PC Chassis Ground Figure 3.2 RS-232 9 way Port Pin Designations Page 8

3.1.3 RS-422/485 9 way Port Connections to the RS-485 are made via 9 pin D type connectors on the interface. The onboard connectors are male and the mating sockets are available as accessories. Provision is made for securing by screw jacks. The 9 pin D connector is pin-out compatible with the default pin-out of the Amplicon PC248/PC249(i) series cards. Transmitted Data - B Transmitted Data - A Reference Ground 5 9 4 8 3 7 2 6 1 Received Data - B' Received Data - A' PC Chassis Ground In full duplex operation, pins 4 and 5 provide the balanced Tx O/P, pins 8 and 9 provide the balanced Rx I/P In half duplex operation, pins 4 and 5 must be externally linked to pins 8 and 9 to provide transceiver I/P and O/P Figure 3.3 RS-422/485 Amplicon Standard Port Pin Designations 3.2 The Ground Connections Each connector is equipped with two or more different ground connections and care must be taken in the use of these grounds and the cable design to ensure that the EMC requirements are met, and that isolation integrity is maintained in the case of the devices with isolated input/output. The connector pin-out is such that commercially available cables and adapters are normally usable without modification, but the user must be aware of the requirements to maintain isolation when the devices at each end are not at nominal earth potential. The choice of proper, screened cables is also important for the system to maintain Electro-Magnetic Compatibility. 3.2.1 USB 232 Ground Connections Reference Signal Ground (pin 5 of 9 way) is internally connected to the PC USB signal ground and should be externally connected to the Signal Ground pin of the RS-232 device at the other end of the link. The Connector Shell is internally connected to the PC USB chassis ground. Protective ground should be externally connected to the protective ground pin of the RS-232 device at the other end of the link. To maintain shield integrity, metal connector hoods should be used, preferably at both ends. These hoods make contact with the connector shell and the cable screen so maintaining an overall shield. Page 9

3.2.2 USB485 Ground Connections Reference Ground is internally connected to the PC USB signal ground that is not normally required for the differential operation of RS-422/485 line pairs. This pin may be left unconnected. Connector Shell is internally connected to the PC USB chassis ground. To maintain shield integrity, metal connector hoods should be used, preferably at both ends. These hoods make contact with the connector shell and the cable screen so maintaining an overall shield. 3.2.3 USB485i Ground Connections Reference Ground is internally connected to the isolated signal ground that must be connected to the signal ground of the remote RS-422/485 device. Any voltage appearing between this reference ground and the host PC USB ground is common mode and must not exceed 250 V peak. The internal resistance between these grounds is 1 MΩ. Connector Shell is not connected. To maintain shield integrity, a metal connector hood should be used which must be connected to the cable screen at the remote device. 3.3 Choice of Cable As speeds and distances of communication increase the choice of cable over which the communication is to take place becomes critical. Belden Cable, part no. 8132 is recommended for use in long distance high speed RS422 & RS485 networks. This is multi-shielded twisted pair cable. It has a capacitance of 20pF/m and characteristic impedance of 120 ohms. In order to maintain compliance with the EMC directive, 89/336/EEC, it is mandatory that the final system integrator uses good quality screened cables for external connections. It is up to the final system integrator to ensure that compliance with the Directive is maintained. Please contact Technical Support (paragraph 1.4.2) for further information. Page 10

4 PROGRAMMING The USB232/485 interfaces are supplied with Windows 98, ME, 2000, XP and Linux specific drivers. Programming for use under other operating systems is beyond the scope of this manual. 4.1 Programming with Windows 98, ME, 2000 and XP Device drivers. Application programmers writing programs to run under these operating systems will simply treat the port as a standard COM port. All Programs written to run under these operating systems will be able to use the advanced features of the device. 4.2 Half Duplex Transmission Turnaround In a multiple RS-485 transmitter installation, the application program controls the data communication turnaround and the selection of the bus 'talker'. Two common ways of providing program control are the 'Master/Slave' and 'Token Ring' methods. The 'Master/Slave' method designates one device on the network as Master, and this device supervises all transmissions by communicating with each of the Slaves in turn and offering it a transmission slot. In token ring operation, each device knows its ID neighbour and only talks directly to this next device. Thus communication only occurs between adjacent pairs of devices and this makes for a flexible network but can be a more difficult method to implement. In half duplex mode the RS485 transmit buffer is enabled automatically, by the FT8U232AM UART, whenever data is waiting to be sent in the UART Transmit buffer. This feature makes efficient multi-drop communication simple to implement by removing the burden of the Transmit buffer enable control from the software. Programmers may find this feature useful when trying to implement multi-drop systems using Application software that does not support control of the transmitter. The port can simply be configured as a Half-Duplex port using jumpers. The application software will then treat the port as it would any other. Transmit buffer enabling and disabling will then take place automatically. Page 11

Appendix A - TECHNICAL SPECIFICATIONS Figures given in the specification are typical at 25 C, except where otherwise stated. A.1 HARDWARE SPECIFICATION There are three interfaces available in the range: USB232 Communications RS-232 I/O Connector 9 way male D USB485 Communications RS-485 I/O Connector 9 way male D USB485i Communications Isolated RS-485 I/O Connector 9 way male D A.1.1 USB A.1.1.1 Series B connector A.1.1.2 Power (VBus) 4 way series B connector, Pinout to USB 1.1 input/output standard. The connector shell is connected to the USB chassis ground. Min Typ Max High power port(v) 4.75 5.25 Low power port(v) 4.40 5.25 A.1.1.3 Input Levels Min Typ Max High driven(v) 2.00 High floating (V) 2.7 3.6 Low(V) 0.8 Differential input sensitivity(v) 0.2 Differential common mode range(v) 0.8 2.5 A.1.1.4 Output Levels Min Typ Max High driven(v) 2.8 3.6 Low(V) 0.0 0.3 Output signal crossover(v) 1.3 2.0 Page i

A.1.2 USB232 RS-232 Port A.1.2.1 9 way Connector A.1.2.2 Configuration A.1.2.3 Rx Voltage Levels 9 way, male D connector with metal shell. Pinouts to IBM input/output standard. The connector shell is connected to the local PC chassis ground. USB232 ports is configured as Data Terminal Equipment (DTE) RS-232 receivers - RXD, DCD, DSR, CTS and RI Min Typ Max Input threshold low (V) 0.8 1.3 Input threshold high (V) 1.7 2.4 Input hysteresis (V) 0.1 0.4 1.0 Input resistance (kω) 3 5 7 A.1.2.4 Tx Voltage Levels RS-232 drivers - TxD, DTR and RTS Min Typ Max Output voltage swing Pos (V) +5.0 +7.3 (Loaded 3 kω to Gnd) Neg (V) 6.5 5.0 Output short circuit current (ma) ±17 A.1.2.5 Data Rate The port is capable of error free transmission at data rates up to 920 k Baud. A.1.2.6 I/O Protection Driver outputs and receiver inputs can be shorted beyond the RS-232 fault limits to ±30 V without damage. A.1.2.7 ESD Protection The RS-232 line input/outputs have on-chip protection from ESD transients up to ±8 kv for human body model discharges. Page ii

A.1.3 USB485 and USB485i RS-422/485 Port A.1.3.1 9 way Connector A.1.3.2 Rx Voltage Levels 9 way, male D connector with metal shell. For the isolated versions, all signals are referred to the remote device signal ground. RS-422/485 receiver - RXD Differential threshold voltage (V) ( 7 Vcm 12 V) Receiver input hysteresis (mv) (Vcm = 0 V) Receiver input resistance (kω) ( 7 Vcm 12 V) Min Typ Max 0.2 0.2 70 12 A.1.3.3 Rx I/P Termination A.1.3.4 Tx Voltage Levels 120 Ω resistor across differential input terminals of both Rx Data and CTS receivers. For multi-drop applications, the Rx data line termination resistor can be disconnected by removing a jumper. RS-422/485 driver - TXD Differential driver output (no load) Differential Load = 50 Ω driver output (RS-422) (with load) Load = 27 Ω (RS-485) Driver common mode output voltage Differential output load resistance Min Typ Max 5 V 2 V 5 V 1.5 V 5 V 3 V 27 Ω A.1.3.5 Tx O/P Protection Excessive output current and power dissipation caused by faults or bus contention are prevented by two mechanisms. A fold-back current limit provides immediate protection against short circuits and thermal protection forces the driver into a high impedance state if the die temperature exceeds the limits. A.1.3.6 I/O Isolation For the isolated versions, each RS-485 interface is electrically isolated, with no common connections to the other port. Signal isolation is by opto-couplers on the data lines and power to the drivers/receivers is supplied through an isolated DC-DC converter. Page iii

Isolation specifications measured between Reference Signal Ground of the external device and Chassis Ground of the USB are: Maximum test voltage Maximum user applied voltage (Short duration) Maximum user applied voltage DC (Sustained) Maximum user applied voltage AC (Sustained) Typical on-board common mode Impedance ±400 Vpk ±250 Vpk ±75 VDC 50 VAC 1 MΩ in parallel with 1 nf A.1.3.7 ESD Protection A.1.3.8 Modes The RS-422/485 line input/outputs have on-chip protection from ESD transients up to ±8 kv for human body model discharges. Full Duplex, Half Duplex, Multi-drop, Broadcast. The mode of operation is jumper selectable see 2.3.1.1 and 2.3.1.2. A.1.3.9 Transmit Turnaround Transmission turn around is internal to the device. When in half duplex mode, the transmitter is automatically enabled when there is data to transmit. A.1.4 UART One FDTI FT8U232AM USB UltraBaud Data Transfer IC. A.1.4.1 Baud Rates A.1.4.2 Data Bits A.1.4.3 Stop Bits A.1.4.4 Parity All standard rates from 50 baud to 1.5Mbaud can be generated. Programmable 5, 6, 7 or 8. Programmable 1 or 2. Programmable Even, Odd or None. A.1.5 PC INTERFACE A.1.5.1 Compatibility A.1.5.2 Host resources USB Bus revision 1.1 compatible. Fully plug and play configurable. Page iv

A.1.5.3 USB Frame Rate A.1.5.4 USB packet size 1 millisecond. 64 bytes. A.2 SOFTWARE The distribution software is supplied on a CD-ROM. Windows 98, ME, 2000 and XP Driver Software provides Application level access to all the advanced features of the device from these operating systems. A.3 ENVIRONMENTAL CONDITIONS A.3.1 Specific conditions A.3.1.1 Dimensions Length Width Height 87 mm plus edge connectors. 43 mm. 26 mm. A.3.1.2 Temperature Range Operating 0 C to +50 C. Storage 20 to +60 C. A.3.1.3 Power Requirements +5 VDC from USB. Current required is less than one load unit, < 100 ma. A.3.1.4 Dissipation Each device will dissipate less than 0.5 Watts of heat. A.3.1.5 Electro Magnetic Compatibility (89/336/EEC) Electro-Magnetic Compatibility All devices in the USB232/485 Series comply with the European directive 89/336/EEC. Page v