URGENT IMPORTANT FIELD SAFETY NOTIFICATION

Similar documents
URGENT IMPORTANT FIELD SAFETY NOTIFICATION

Monaco VMAT. The Next Generation in IMRT/VMAT Planning. Paulo Mathias Customer Support TPS Application

URGENT IMPORTANT FIELD SAFETY MODIFICATION

Real-time monitoring of linac performance using RT plans and logfiles

Computational modelling and analysis: IOP Medical Physics Group

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS

Hugues Mailleux Medical Physics Department Institut Paoli-Calmettes Marseille France. Sunday 17 July 2016

THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER!

FAST, precise. qa software

IMPORTANT FIELD SAFETY MODIFICATION

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE

Using a research real-time control interface to go beyond dynamic MLC tracking

8/2/2017. PerFRACTION from Sun Nuclear Automated Transit Dosimetry for In-Vivo QA

Elekta. DICOM Conformance Statement for Elekta Precise Treatment System TM Release 4.0 and 4.1. Document Number: Date: 05 August 2002

IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays

ADVANCING CANCER TREATMENT

Radiation therapy treatment plan optimization

PrecisePLAN 2.00 Import

Dynalog data tool for IMRT plan verification

Treatment Planning Optimization for VMAT, Tomotherapy and Cyberknife

Machine and Physics Data Guide

DICOM Conformance Statement For Integrity Release 3.0

PrecisePLAN 2.15 Export

IHE Radiation Oncology Technical Framework Supplement. Treatment Delivery Plan Content (TDPC) Rev. 1.1 Trial Implementation

Facility Questionnaire PART I (General Information for 3DCRT and IMRT)

Volumetric Modulated Arc Therapy - Clinical Implementation. Outline. Acknowledgement. History of VMAT. IMAT Basics of IMAT

PyCMSXiO: an external interface to script treatment plans for the Elekta CMS XiO treatment planning system

ADVANCING CANCER TREATMENT

ICARO Vienna April Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588

Delta 4. DICOM Conformance Statement D (7)

Table of Contents. About AQUA

Data. ModuLeaf Mini Multileaf Collimator Precision Beam Shaping for Advanced Radiotherapy

Acknowledgments. Ping Xia, Ph.D., UCSF. Pam Akazawa, CMD, UCSF. Cynthia Chuang, Ph.D., UCSF

PCRT 3D. Scalable Architecture System. User-Friendly. Traceable. Continuos Development

INTEGRATED DATA MIGRATION:

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT

Image Quality Assessment and Quality Assurance of Advanced Imaging Systems for IGRT. AAPM Penn-Ohio Chapter Sep 25, 2015 Soyoung Lee, PhD

Technical Publications

Evaluation of 3D Gamma index calculation implemented in two commercial dosimetry systems

DAILY LINAC QA BEAM QA

Technical Publications

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC

An Optimisation Model for Intensity Modulated Radiation Therapy

Description of the Issue:

XiO DICOM Conformance Statement

Digital Imaging and Communications in Medicine (DICOM) Supplement 176: Second Generation Radiotherapy. Additional RT Treatment Modalities

Available online at ScienceDirect. Procedia Computer Science 100 (2016 )

IAEA-TECDOC-1583 Commissioning of Radiotherapy Treatment Planning Systems: Testing for Typical External Beam Treatment Techniques

Initial Clinical Experience with 3D Surface Image Guidance

Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon

FocalSim DICOM Conformance Statement. Table of Contents:

Advanced Radiotherapy

Open-source software for collision detection in external beam radiation therapy Vinith M. Suriyakumar, Renee Xu, Csaba Pinter, Gabor Fichtinger

Screening Procedures for Access to ISO Register of Transmission Facilities and Entitlements

Laser Systems for Patient Alignment

DICOM Conformance Statement. Leksell GammaPlan & Leksell SurgiPlan 10.2

3DVH : SUN NUCLEAR On The Accuracy Of The corporation Planned Dose Perturbation Algorithm Your Most Valuable QA and Dosimetry Tools *Patent Pending

TG-148 overview. Introduction. System Overview. System Overview. QA for Helical Tomotherapy: Report of the AAPM Task Group 148. Conflict of Interest:

TEPZZ Z754_7A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (51) Int Cl.: A61N 5/10 ( )

CLINICAL ASPECTS OF COMPACT GANTRY DESIGNS

MapCHECK 2 & 3DVH. The Gold Standard for 2D Arrays

URGENT FIELD SAFETY NOTICE

Use of Monte Carlo modelling in radiotherapy linac design. David Roberts, PhD Senior Physicist Elekta

MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays

3D SCANNER. 3D Scanning Comes Full Circle. Your Most Valuable QA and Dosimetry Tools

Raising the Bar in IMRT QA

Elekta Limited DICOM Conformance Statement For Elekta Synergy Release 4.2

Disclosure. Outline. Acknowledgments. Ping Xia, Ph.D., Page 1. LINAC and MLC QA for IMRT. Received research support from Siemens Medical Solutions

CARS 2008 Computer Assisted Radiology and Surgery

COMPARISON OF DOSE CALCULATION ALGORITHMS FOR LEKSELL GAMMA KNIFE PERFEXION USING MONTE CARLO VOXEL PHANTOMS

INSTRUCTIONS RPD INFORMATION RPD PRODUCT INFORMATION. Address 5218 Barthel Industrial Drive Albertville, MN Website

PURE. ViSION Edition PET/CT. Patient Comfort Put First.

Monaco Concepts and IMRT / VMAT Planning LTAMON0003 / 3.0

Dose Calculation and Optimization Algorithms: A Clinical Perspective

Radiation therapy plan checks in a paperless clinic

A Geant4 based treatment plan verification tool: commissioning of the LINAC model and DICOM-RT interface

Tumor motion during liver SBRT

Customer Technical Reference. DICOM Conformance Statement: Proton Treatment Console

Technical Publications

Future is Effortless

Chapter 1 General Information

TOMOHD. Product Specifications

Integrated proton-photon treatment planning

SRI GURU RAMDAS INSTITUTE OF MEDICAL SCIENCES & RESEARCH MEHTA ROAD, VALLAH, SRI AMRITSAR

Future Topics. Projection Imaging Dose Reporting, XA 3D Volume Objects. for DICOM WG-02. Presented by Heinz Blendinger, Siemens Medical Solutions

State-of-the-Art IGRT

DF/HCC Operations for Human Research Subject Registration Procedures

Technical note: Using k-means clustering to determine the number and position of isocenters in MLC-based multiple target intracranial radiosurgery

A secondary monitor unit calculation algorithm using superposition of symmetric, open fields for IMRT plans

Acceptance Checklist for Special 510(k)

MARPA DOCUMENT MARPA Revision 1.1

TRAJECTORY- BASED TREATMENT PLANNING AND DELIVERY FOR CRANIAL RADIOSURGERY

An experimental evaluation of the Agility MLC for motion-compensated VMAT delivery

Optimization approaches to volumetric modulated arc therapy planning

Version 5.6. Quick Start Guide

Code of practice: Create a verification plan for OCTAVIUS Detector 729 in Philips Pinnacle³

A Mimetic Algorithm for Simultaneous Multileaf Collimator Aperture Shape and Dosimetric Optimization in CyberKnife Robotic Radiosurgery

An experimental investigation on the effect of beam angle optimization on the reduction of beam numbers in IMRT of head and neck tumors

Photon beam dose distributions in 2D

Complete the Confirmation Sheet, and return it to Physio-Control using the information on the form.

Transcription:

Subject: Product: Incorrect Rotation of the Collimator or Couch ERGO Scope: Sites affected will be those: 1. Running ERGO version 1.7.3 and higher and, 2. Using a Multileaf Collimator (MLC) device for planning Notification Released: September, 2017 Description of Problem: Elekta has become aware of the potential for incorrect DICOM mapping of the exported collimator or couch angles from ERGO, which would lead to incorrect rotation of the collimator or couch when using a MLC device for planning. Verification tests are included with this notice. It is recommended that you complete these tests before proceeding with any further patient treatments. Details: If the DICOM export values are not mapped correctly, it is possible that treatments could be delivered with the wrong collimator or couch angle. Clinical Impact: Patients can be treated with the wrong collimator or couch angle. This would result in a geometric miss with the tumor potentially underdosed and normal structures overdosed. This document contains important information for the continued safe and proper use of your equipment. Please post this notice in a place accessible to all users, e.g. Instructions for Use, until this action is closed. Advise the appropriate personnel working with this product the content of this letter FCO: 382-01-ERG-001, VID: 1.0 Elekta, Inc. Page 1 of 6

Recommended User Action: If you are using a MLC for dose planning in ERGO, please run the verification test below to ensure that your collimator and couch are rotating correctly. If the test passes successfully, please sign the Acknowledgement form and return the form to Elekta. If the test fails please contact your local Elekta Care Support Center for assistance. If you are not using a MLC in ERGO, please sign the Acknowledgement form, add a note to confirm that you are not planning with an MLC at your clinic and then return the form to Elekta. If you have questions about the applicability of this customer notification, please contact your local Elekta Care Support Center before completing and returning the Acknowledgement form to Elekta. FCO: 382-01-ERG-001, VID: 1.0 Elekta, Inc. Page 2 of 6

Test Purpose ERGO Elekta Customer Verification Test This document specifies the test for customer verification that collimator and couch angles are configured correctly inside ERGO and can be delivered consistently when exported to the Linac console. This verification checklist outlines the necessary tests for Elekta Service personnel and customers to ensure the integrity of the installed applications in the configured environment. The intent is that the site personnel test each item and, if satisfied, initial and date to confirm their verification. Before running tests it is necessary to make sure that the MLC and Linac in use are properly configured so that angles inside DICOM plans created by ERGO match those in the actual devices. Test description and verification checklist Rows inside the table contain set-up of the beams that must be created with ERGO Dynamic Multileaf (DMS) module and exported as DICOM plans to the Record & Verify console. The last two columns of the table must contain results of the verification (passed or failed): - Record & Verify check All plan angles displayed inside the DMS window must be equal to those appearing inside the Record & Verify and MLC controller units - Light Field check Positions of the leaves planned inside DMS must be consistent (field shape and orientation) with those appearing with the light field on the Linac couch. To facilitate execution of this test it is suggested to create shapes with asymmetries like the example in figures 1 and 2. Test execution In ERGO TPS push the images of Uterus demo patient (or another patient proven to be HFS - View From Gantry) and create a new patient inside the database. Open DMS module and put a single beam with angles as specified inside the table. Create a separate beam for each row and send the DICOM plan(s) to the controller unit. You can export a single plan with all beams inside the table or a separate plan for each row. FCO: 382-01-ERG-001, VID: 1.0 Elekta, Inc. Page 3 of 6

First perform beam verification on the Record & Verify console and then check shape correctness with the light field. Light field verifications are only possible using plans with gantry angle 0. Field Number Setup Gantry Angle Collimator Angle Couch Angle R&V Pass/Fail Light Field Checks Pass/Fail 1 0 Default Position 0 2 0 Default Position +30 0 3 0 Default Position 30 4 0 Default Position + 20 315 5 0 Default Position - 20 45 6 34 Default Position +56 66 N/A 7 238 Default Position -37 321 N/A Default collimator angle (Default Position) for integrated BLD is 0, for APEX is 270. For other add-on collimators the default position may change depending on the collimator model in use, refer to documentation applicable to the product. Tester Name:.. Tester Signature:.. Test Date: FCO: 382-01-ERG-001, VID: 1.0 Elekta, Inc. Page 4 of 6

Exemplificative figures Figure 1 - Screenshot of ERGO Figure 2 - Light field FCO: 382-01-ERG-001, VID: 1.0 Elekta, Inc. Page 5 of 6

Acknowledgement Form In order to meet regulatory requirements, you are required to complete this form and return it to Elekta immediately upon receipt but no later than 30 days. Classification: Important Field Safety Notification FCO Reference Number: 382-01-ERG-001 Description Incorrect Rotation of the Collimator or Couch Hospital: Device Serial No(s): (if applicable) Location or Site: I acknowledge that I have read and understood this Notice and accept implementation of any given recommendations. Name: Customer Signature: Title: Date: New installation confirmation to be signed by the installing Elekta engineer or Representative employee when the installed product has a physical IFU/manual: I acknowledge that the customer is informed on the content of this notice and that it has been inserted into the applicable copy of the User Manual or added to the record with the applicable User Manual: Name: Title: Signature: Date: FCO: 382-01-ERG-001, VID: 1.0 Elekta, Inc. Page 6 of 6