Metering. Lovato E-1 Socomec E-7. Modular energy (kwh) meters. Lovato E-2 Socomec E-8. Modular multi-meters. Lovato E-3 4 Socomec E-8 9

Similar documents
Metering. Lovato E-1 Socomec E-7. Modular energy (kwh) meters. Lovato E-2 Socomec E-8. Modular multi-meters. Lovato E-3 4 Socomec E-8 9

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

with Backlight Graphic LCD Screen

DIGITAL METERING INSTRUMENTS DMG SERIES

DIRIS Digiware Measurement and monitoring system for electrical installations multi-circuit plug & play

DIRIS Digiware Measurement and monitoring system for electrical installations

Digital multimeters DMG

DIRIS A. Multifunction measurement units for managing your electrical networks

DIRIS A-30 Multifunction power metering & monitoring device - PMD

Expansion modules and accessories

Page Page Page ACCESSORIES Communication devices Remote display unit Protective covers Converters Gateway Connecting cables.

AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

MIC-2 MKII, Multi-instrument DATA SHEET

Digital metering instruments and current transformers

DIRIS Digiware. Energy Measurement & Monitoring System. Plug & Play metering, monitoring and analysis system

DIRIS Digiware. Energy Measurement & Monitoring System. Version 16. Plug & Play metering, monitoring and analysis system

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Switches Unlimited Contact: Phone: * Fax:

E N E R G Y M E T E R S

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

DIRIS N300/N600 Network analysers Network quality control and analysis system

MIC-2 Multi-instrument DATA SHEET

Metering instruments and current transformers

DIRIS A & DIRIS B Power Metering and Monitoring Devices

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

E 1. SPECOM - Network analyser. Content. E.2 Description. E.3 Specom C - Technical data. E.4 Specom M - Technical data. E.5 Data communication

DIRIS Digiware Power metering and monitoring system for AC and DC electrical installations

DIRIS Digiware Power metering and monitoring system for AC and DC electrical installations

DIRIS Digiware D and C Communication and control power interfaces

DIRIS B-10 & B-30. Multifunction meters and associated current sensors INSTRUCTION MANUAL. en/diris-b

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

PQM - Power Quality Monitoring

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Digital Multifunction Meters. Digital Multifunction Meters

DIRIS Digiware Measurement and monitoring system for electrical installations multi-circuit plug & play

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

SUBJECT TO CHANGE WITHOUT NOTICE

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information

Electrical multifunction analysers

METERING INSTRUMENTS DIGITAL MULTIMETERS AND ENERGY METERS NETWORK ANALYZERS DATA CONCENTRATOR COMMUNICATION DEVICES

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

Smart Energy & Power Quality Solutions. UMG 96S Universal flush-mounting measuring instrument

100% electricity. Automatic transfer switch controllers ATL series

Smart Energy & Power Quality Solutions. UMG 505 Power analysis, LON and I/O-Vielfalt

UMG 604. UMG 604 Power analyser. Modbus master, Ethernet gateway. Harmonics. Memory 128 MByte. Homepage. Graphic programming.

AcuRev Multi-Circuit Power and Energy Meter. Shop for Accuenergy products online at:

UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

USER MANUAL 2012 V1.1

EngyVolt RV12 and RV15

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

MDC-20. Maximum Demand predictive Control. Description

SDM630M CT USER MANUAL 2016 V4.7. DIN Rail Energy Meter for Single and Three Phase Electrical Systems

DIGITAL LCD MULTIMETERS AND POWER ANALYZERS Graphic LCD or touch screen Remote display Expandable versions.

WM20. Power analyzer for three-phase systems. Benefits. Description

COUNTIS E. Active and reactive energy meters and multi-utility pulse concentrators

DIRIS N. Electrical network analysis system for quality control of your facilities

ATS Automatic transfer switches Advanced version

Comprehensive Modular Genset Controller

DIRIS Digiware Measurement and monitoring system for electrical installations multi-circuit plug & play

Electronic Submeter with Advanced WiFi Ethernet Capability

Multifunction Transducer MT440

Power Meter PowerMonitor 500

Easy Config. Configuration tool for ATYS, COUNTIS and DIRIS INSTRUCTION MANUAL. easy-config_software

DIRIS Digiware DC Measurement and monitoring system for DC electrical installations

A2000 Multifunctional Power Meter

Voltage Transducer UMT516 / MT516

PM130 PLUS PM130 PLUS POWER METER. Features. Models. Multifunctional 3-phase Power Meter

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

Page measurement up to 15th order Front optical USB and Wi-Fi communication port for PC, smartphone and tablet connection

Modular PDU Smart metering for your IT

A1700 CT Metering. The Power to Change...

Bus Bar Protection Relay B-PRO 4000

AP25-1DO METER (MID CERTIFIED) User Manual - Issue 1.0

ENGINE, GENERATOR AND ATS CONTROLLERS. Engine Protection Controllers p18-1

DIRIS Digiware Measurement and monitoring system for electrical installations multi-circuit plug & play

B+G E-Tech User Manual for SDM630 SDM630. Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 2013 V1.

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application

DIRIS A. The multi-function measurement range MADE TO MEASURE

Energy Division. Crompton Instruments Integra 1630 Low Profile Digital Metering System

INTEGRA DIGITAL METERING SYSTEMS

Power Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser

Power factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port

SOFT STARTERS PLANET -LOGIC

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

PM800 series. Applications

SINGLE PHASE AMR ELECTRONIC METER MEM Electric meter has the following functions: Technical information

Multifuncion Measuring Device 96x96 mm, connection via CT

PMC 530 Series Advanced Multifunction Meter

EM QUICK START GUIDE. Quick Start Guide EM BG0504 REV.A2

Automation control units

AUTOMATIC POWER FACTOR CONTROLLERS AND THYRISTOR MODULES 23

ACUREV Three-Phased DIN-Rail Multifunction Meter FEATURES

VMU-C/Y, Em 2 CARLO GAVAZZI. The evolution in Energy Management. Monitoring system for Energy Management. A u t o m a t i o n C o m p o n e n t s

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

Transcription:

7% Metering E Modular energy (kwh) meters Lovato E-1 Socomec E-7 Modular multi-meters Lovato E-2 Socomec E-8 Panel mount network analysers Lovato E-3 4 Socomec E-8 9 Digital panelmeters Lovato E-5 6 Digiware power montoring system Socomec E-10 12 Current transformers (CT's) MBS E-13 18 EM E-20 Split core (CT's) MBS E-18 J&D E-20 Analog panel meters EM E-21 Portable network analysers Circuitor E-22 Power analyser Socomec E-23

Energy meters (kwh meters) Energy meters are digital instruments for the measurement of electrical energy consumption in single and three phase systems with direct connection or via current transformer (CT) Digital meters with LCD screen static module type input description pulse width x current output 18 mm DMED110T1 Single phase direct connection 40/63A Rated supply voltage: 220-240 VAC +15-20% Input current: 40/63A (direct connection) Active energy: Class 1 (IEC/EN 62053-21) Reactive energy: Class 2 (IEC/EN 62053-23) Compliant with standards: IEC/EN 61010-1, 61000-6-2, 61000-6-3 (modular design DIN rail mountable) DMED100T1 40A direct connection digital energy meter 1 1 1183.00 Multi-measurements: Total and partial active, reactive energy, active, reactive power, voltage, current and power factor. DMED110T1 40A direct connection digital energy meter 1 1 2207.00 DMED120T1 63A direct connection digital energy meter 1 2 1546.00 DMED121 63A as above with RS485 interface 2 2456.00 DMED130 63A expandable with EXM1001 module 2 2137.00 DME120T1 3 phase direct connection 63A/80A (modular design DIN rail mountable) Multi-measurements: Total and partial active, reactive energy, active, reactive power, voltage, current and power factor. Graphic backlit LCD screen with 6+1 digits Tariff selection (2 tariffs) DMED300T2 63A 3ph+N digital energy meter 2 4 3372.00 DMED301 80A 3ph+N digital energy meter (RS485) 4 4365.00 3 phase CT connection /5A (modular design DIN rail mountable) Multi-measurements: Total and partial active, reactive energy, active, reactive power, voltage, current and power factor. DMED300T2 Backlit LCD screen (128 x 80 pixels) DMED310T2 /5A 3ph digital energy meter 2 4 3841.00 DMED330 /5A 3ph digital energy meter (RS485) 4 4684.00 Accepts EXM... (up to 3) plug-in optic expansion modules Data concentrator (modular design DIN rail mountable) DMECD data concentrator designed in combination with energy meters, permitting connection to (up to 8) devices, eliminating online communication interface requirements. The concentrator is able to count static pulse outputs from the connected energy meters, storing data for viewing on its display or directly on a PC through the built-in RS485 port, using Xpress software. DMECD Graphic backlit LCD screen (128 x 80 pixels) 8 inputs for pulse count, expandable up to 14 using EXM type expansion modules 8 total and 8 partial energy meters Built-in RS485 interface (Modbus-RTU or ASCII) Expandable with EXM... (up to 3) plug-in optic expansion modules DMECD data concentrator for up to 8 connected energy meters 4 5691.00 EXM1000 Expansion modules for DMED310T2 and DMECD (modular design DIN rail mountable) EXM1000 2 digital inputs and 2 static outputs, opto-isolated 2 2319.00 EXM1001 2 opto-isolated digital inputs and 2 relay outputs (5A 250 VAC) 2 2319.00 EXM1010 opto-isolated USB interface 2 2319.00 EXM1011 opto-isolated RS232 interface 2 2319.00 EXM1012 opto-isolated RS485 interface 2 2319.00 EXM1013 opto-isolated Ethernet interface with Web server function 2 4593.00 EXM1020 opto-isolated RS485 interface and 2 relay outputs (5A 250 VAC) 2 3320.00 EXM1030 data storage, clock-calendar (RTC) with backup for data logging 2 5411.00 E-1 Above s do not include VAT. E&OE

DMG series digital multimeters / Power analysers new DMG digital multimeters and power analysers are equipped with a digital LCD display providing extremely clear, intuitive and flexible viewing of all electrical parameters in an installation. DMG digital multimeters in a modular housing (4 modules wide) Modular DIN rail mounting (aligns with standard MCB 45mm cutout) Accuracy: Voltage/Current: ±0.5% (True RMS measurements) Power: ±1% f.s. Frequency: ±0.05% Active energy: Class 1 Metering DMG100 Main measurements: - Voltage: phase, line and system values - Current: phase values (neutral current calculated) - Power: apparent, active and reactive phase and total values - Power Factor (PF) per phase and total - Frequency of measured voltage value - HIGH-LOW-AVERAGE value functions of all measurements - Maximum demand of power and current values - Asymmetric voltage and current - Total harmonic distortion (THD) of voltage and current values - Energy meters for active, reactive and apparent values - Hour counter (total and partial) type description module width x 18 mm DMG200 DMG100 series LCD multimeters economical with icon display Auxiliary power supply: 100-240 VAC / 120-250 VDC Input current: CT - 1A or 5A Voltage measurement: 50-720 VAC L-L Harmonic analysis of V and I up to the 15th order DMG100 modular power analyser 4 3410.00 DMG110 modular power analyser with RS485 interface 4 3956.00 DMG200 series LCD multimeters Auxiliary power supply: Input current: Voltage measurement: with graphic backlight LCD display 100-240 VAC / 110-250 VDC CT - 5A 20-830 VAC L-L DMG300 DMG200 modular power analyser 4 4547.00 DMG210 modular power analyser with RS485 interface 4 5911.00 DMG300 series (expandable) with graphic backlight LCD display Auxiliary power supply: 100-240 VAC / 110-250 VDC Input current: CT - 1A or 5A Voltage measurement: 20-830 VAC L-L /10-480 VAC L-N Optional communication ports: USB, RS232, RS485, Ethernet Harmonic analysis of voltage and current up to the 31 order Energy meters for active, reactive, apparent power with programmable tariff function Accuracy: voltage/current ±0.2% power/power factor ±0.5% frequency ±0.05% active energy class 0.5S (IEC/EN 62053-22) EXM1000 DMG300 modular power analyser (up to 344 measured quantities) 4 6820.00 Accepts EXM...(up to 3) plug-in optic expansion modules Expansion modules and accessories for DMG300 EXM8004 sealable terminal cover for DMG200/210/300 2 75.00 EXM1010 EXM1000 2 digital inputs and 2 static outputs, opto-isolated 2 2319.00 EXM1001 2 opto-isolated digital inputs and 2 relay outputs (5A 250 VAC) 2 2319.00 EXM1010 opto-isolated USB interface 2 2319.00 EXM1011 opto-isolated RS232 interface 2 2319.00 EXM1012 opto-isolated RS485 interface 2 2319.00 EXM1013 opto-isolated Ethernet interface with Web server function 2 4593.00 EXM1020 opto-isolated RS485 interface and 2 relay outputs (5A 250 VAC) 2 3320.00 EXM1030 data storage, clock-calendar (RTC) with backup for event logging 2 5411.00 Above s do not include VAT. E&OE E-2

DMG series digital multimeters / Power analysers new Flush mounting expandable digital multimeters (96 x 96 mm) Rear expansion slots accept plug-in modules suitable for numerous applications True RMS measurements of voltage and current values Main measurements and functions : DMG 600 - Voltage: phase, line and system values - Current: phase values (neutral current calculated) - Power: apparent, active and reactive phase and total values - Power Factor (PF)per phase and total - Frequency of measured voltage value - HIGH-LOW-AVERAGE value functions for all measurements - Maximum demand of power and current values - Voltage and current asymmetry - Total harmonic distortion (THD): voltage and current - Energy meters with programmable tariff functions - Hour counter for programmable total and partial hours type description expansion slots DMG600 series economical with backlit LCD icon display Harmonic analysis of voltage and current up to the 15 order Auxiliary power supply: 90-484 VAC / 94-300 VDC Input current: CT - 1A or 5A Voltage measurement: 50-720 VAC L-L Accuracy: Voltage/current ±0.5% Power/power factor ±1% f.s. Frequency ±0.05% Active energy Class 1 (IEC/EN 62053-21) Reactive energy Class 2 (IEC/EN 62053-23) DMG600 digital panel mount power analyser 1 3865.00 DMG610 digital panel mount power analyser (with RS485 port) 1 4547.00 Expandable with EXP module (1) DMG700 series with backlit graphic LCD display DMG 700 Auxiliary power supply: 100-440 VAC / 94-300 VDC Input current: CT - 5A Voltage measurement: 20-830 VAC L-L / 10-480 VAC L-N Pulse counter for consumption of water, gas, etc., (only with expansion module) Accuracy: Voltage/current ±0.5% Power ±1% f.s. Frequency ±0.05% Active energy Class 1 (IEC/EN 62053-21) Reactive energy Class 2 (IEC/EN 62053-23) DMG700 panel mount power analyser 4 4774.00 Expandable with EXP module (up to 4 modules) DMG800 series with backlit graphic LCD display Graphic LCD display Harmonic analysis of voltage and current up to the 31 order Auxiliary power supply: 90-484 VAC / 94-300 VDC Input current: CT - 1A or 5A Voltage measurement: 20-830 VAC L-L / 10-480 VAC L-N Accuracy: Voltage/current ±0.2% Power/power factor ±0.5% Frequency ±0.05% Active energy Class 0.5S (IEC/EN 62053-22) Reactive energy Class 2 (IEC/EN 62053-23) DMG800 panel mount power analyser 4 6820.00 DMG 800 DMG800D048 (as above but with 9-70 VDC supply) 4 8184.00 Expandable with EXP module (up to 4 modules) E-3 Above s do not include VAT. E&OE

DMG series digital multimeters / Power analysers DMG900 Flush mounting expandable digital multimeters (96 x 96 mm) Graphic touch-screen LCD display for extremely simple interaction Rear expansion slots accept plug-in modules suitable for numerous applications True RMS measurements of voltage and current values Main measurements and functions : - Voltage: phase, phase-neutral and ground neutral-earth - Current: phase values - Neutral current calculated and true values - Power: apparent, active and reactive phase and total values - P.F. Power Factor per phase and total - Cosφ per phase - Frequency of measured voltage value - Voltage and current asymmetry - Total harmonic distortion (THD) of voltage and current - Harmonic analysis of voltage and current up to the 63 order - HIGH-LOW-AVERAGE value functions for all measurements - Maximum demand of power and current values - Energy meters with programmable tariff functions - Hour counter for programmable total and partial hours - Pulse counter for consumption of water, gas, etc., (only with expansion module) - Energy quality analysis to EN 50160 (only with expansion module) Metering type description expansion slots DMG900T DMG900 series Graphic touch-screen LCD display Auxiliary power supply: 100-440 VAC /110-250 VDC Input current: CT - 1A or 5A Voltage measurement: 20-830 VAC L-L / 10-480 VAC L-N Accuracy: voltage/current ±0.2% power/power factor ±0.5% f.s. frequency ±0.05% active energy Class 0.5S (IEC/EN 62053-22) reactive energy: Class 2 (IEC/EN 62053-23) DMG900 panel mount power analyser 4 13640.00 DMG900D048 (as above but with 9-70 VDC supply) 4 22328.00 DMG900T DIN rail mount measurement transducer (expandable) DIN rail mounting measurement transducer for chassis mounting, incorporating 4 expansion slots to accommodate expansion modules for added I/O's or communication requirements. DMG900T panel mount power analyser 4 16902.00 DMG900TD048 (as above but with 9-70 VDC supply) 4 20308.00 DMG900RD remote panel mount (96 x 96 mm) touch screen display for above DMG900T 6905.00 Expansion modules and accessories for DMG700/800/900 (up to 4 per meter) DMG900RD Inputs and outputs EXP1000 4 digital opto-isolated inputs 1221.00 EXP1001 4 static opto-isolated outputs 1221.00 EXP1002 2 digital inputs and 2 static outputs, opto-isolated 1465.00 EXP1003 2 output relays (5A 250 VAC) 1465.00 EXP1004 2 analog opto-isolated inputs 0/4-20mA or 0-5/10V (only for DMG800/900) 4393.00 EXP1005 2 analog opto-isolated outputs 0/4-20mA or 0-5/10V (only for DMG800/900) 4393.00 Communication ports EXP1010 opto-isolated USB interface 2197.00 EXP1011 opto-isolated RS232 interface 2197.00 EXP1012 opto-isolated RS485 interface 2197.00 EXP1013 opto-isolated Ethernet interface 4381.00 EXP1014 opto-isolated Profibus-DP interface (only for DMG800/900) 6820.00 EXP1015 GPRS/GSM modem without antenna 5271.00 EXP1030 data storage, clock-calendar (RTC) with backup for data logging 5153.00 EXP1031 as above with energy quality (EN 50160) (only for DMG900/900T) 10981.00 Software and accessories for DMG300/700/800/900 EXP1000 C2 PC - RS232 connecting cable (1.8m) 697.00 C5 RS232 analog modem cable (1.8m) 798.00 C9 cable PC - analog modem cable (1.8m) 913.00 CX03 GSM Quad-band antenna for EXP1015 (850/900/1800/1900/2100MHz) 944.00 Above s do not include VAT. E&OE E-4

Digital meters (measuring and monitoring instruments) DMK modular digital monitoring devices Modular DIN rail mounting (3 modules 54 mm wide) Auxiliary supply: 220-240 VAC Memorises minimum and maximum measured values (since last reset) Instantaneous or preset trip delays (0-900sec) 1 changeover relay output (8A 250 VAC) type description monitored range DMK80R1 Voltage monitors (measures and displays single and three phase voltages) Overvoltage range: Off / 102-120% (delay 0-900sec) Undervoltage range: Off / 70-98% (delay 0-900sec) Voltage/phase loss or failure: Off / 5-85% (delay 0-900sec) Programmable PT ratio : 1.00-500.00 (accuracy: ±0.25% f.s. ±1digit) DMK80R1 1-phase over/under voltage meter/monitor 15-660 VAC 1588.00 DMK70R1 3-phase over/under voltage meter/monitor 15-660 VAC 1767.00 Current monitors (measures and displays single and three phase currents) Measurement range: 0.05A - 5.75A (CT ratio: 5-10.000A) ±0.5% Overcurrent range: Off / 102-200% (delay 0-900sec) Undercurrent range: Off / 5-98% (delay 0-900sec) Instantaneous tripping: Off / 110-600% DMK81R1 1-phase over/under current meter/monitor 0.05A - 5.75A 1646.00 DMK71R1 3-phase over/under current meter/monitor 0.05A - 5.75A 1900.00 DMK81R1 Frequency monitors (measures and displays line frequency) Measurement range: 0.05A - 5.75A (CT ratio: 5-10.000A) ±0.5% DMK83R1 frequency meter/monitor 45-65Hz 2230.00 Three-phase multi-measurement instrument Measurement range: Voltage Phase loss or failure: Off / 5-85% 35-660 VAC Maximum voltage: Off / 102-120% Minimum voltage Off / 70-98% Asymmetry: Off / 2-20% Phase sequence: Off / L1-L2-L3 / L3-L2-L1 DMK83R1 Current Current loss: Off / 2-100% 0.05-5.75A Maximum current: Off / 102-200% Maximum current instantaneous trip: Off / 110-600% Power Rated power: 1-10.000 Maximum power: Off / 101-200% Max power instantaneous trip: Off / 110-600% Minimum power: Off / 10-99% Frequency Maximum frequency: Off / 101-110% 45-65Hz Minimum frequency: Off / 90-99% DMK75R1 3-phase multi measurement digital meter/monitor 2683.00 DMK75R1 E-5 Above s do not include VAT. E&OE

Digital panel meters (measuring and monitoring instruments) DMK00R1 Digital panel meters Panel mount (H) 48 x (W) 96 mm Auxiliary supply 220-240 VAC (others on request) True RMS measurements Class 0.5 (±0.25% full scale ± 1 digit) Memory storage of maximum and minimum values 1 changeover relay output 8A 250 VAC 1 Flush 96 x 48 mm panel mounting Programmable time delay for max, min or voltage/current loss (0-900 sec) Metering type description output Voltmeters (panel mounting 96 x 48 mm) Voltage measurement range: 15-660 VAC Operating frequency range: 45-65Hz Programmable VT ratio: 1.00-500.0 Accuracy: ±0.25% f.s. ±1 digit monitored range DMK00 single phase digital voltmeter meter only 15-660 VAC 1534.00 DMK10 three phase digital voltmeter meter only 15-660 VAC 1677.00 Voltmeter / monitor 1 changeover relay output time delay DMK10R1 Settings Voltage loss or failure: 102-120% Ue (0-900sec) Maximum voltage: 5-85% Ue (0-900sec) Minimum voltage: 70-98Ue (0-900sec) DMK00R1 single phase digital voltage monitor relay out 15-660 VAC 1790.00 DMK10R1 three phase digital voltage monitor relay out 15-660 VAC 1932.00 Ammeters accuracy: ± 0.5% full scale ± 1 digit Current measurement range: 0.05-5.75A Operating frequency range: 45-65Hz Programmable CT ratio: 5-10.000 Accuracy: ±0.5% f.s. ±1 digit DMK01 single phase digital ammeter only meter only 0.05-5.75A 1534.00 DMK11 three phase digital ammeter only meter only 0.05-5.75A 1677.00 DMK01R1 Ammeter / monitor 1 changeover relay output time delay Settings Current loss: Off / 2-100% (0-900sec) Maximum current: Off / 102-200% (0-900sec) Instantaneous trip:: Off / 110-600% Minimum current: Off / 5-98% (0-900sec) DMK01R1 single phase digital current monitor relay out 0.05-5.75A 1790.00 DMK11R1 three phase digital current monitor relay out 0.05-5.75A 1932.00 Frequency meter Measurement input: Frequency measure range: Accuracy: accuracy: ± 1 digit 15-660 VAC 15-65Hz ±1 digit DMK03R1 DMK03 digital frequency meter only meter only 15-65Hz 1534.00 Frequency meter / monitor 1 changeover relay output time delay Settings: Maximum frequency: Off / 101-110% (0.5-900sec) Minimum frequency: Off / 90-99% (0.5-900sec) DMK03R1 digital frequency monitor relay output 15-65Hz 1790.00 Multi-meter combination voltage, current, power factor Voltage: phase-to-phase values Power factor Current: 3 phase Frequency Active, reactive, apparent power and energy Hour counter DMK11R1 Voltage measurement range: 35-660 VAC Current measurement range: 0.05-5.75A Operating frequency range: 45-65Hz Programmable VT ratio: 1.00-500.0 Programmable CT ratio: 5-10.000 DMK16 three-phase multi-meter only meter only multi-meter 2942.00 DMK16R1 three-phase multi-meter and monitor relay out multi-meter 3148.00 Above s do not include VAT. E&OE E-6

COUNTIS active energy meters (kwh meters) COUNTIS Active energy meters (kwh meters) Energy meters are digital instruments for the measurement of electrical anergy consumption in single and three phase systems with direct connection or via a current transformer (CT) type current reading RS485 dual width in description modbus tariff 17.5 mm 4850 3019 Single phase direct connection kwh meters (modular design DIN rail mounting) LCD display Measurement accuracy: 1 % Rated supply voltage: 230 VAC Pulse output: 100Wh Active energy: Class 1 (IEC/EN 62053-21) class B (EN 50470) 4850 3043 4850 3054 new 4850 3019 E00 32A direct no no single phase kwh meter 1 910.00 4850 3039 E03 40A direct yes yes single phase kwh meter 1 1397.00 4850 3000 E10 63A direct no no single phase kwh meter 3 1401.00 4850 3001 E11 63A direct no yes single phase kwh meter 3 1631.00 4850 3043 E13 80A direct yes yes single phase kwh meter 3 3183.00 4850 3047 E17 80A direct no yes single phase kwh meter 2 7384.00 Ethernet web server embedded Three phase kwh meters (modular design DIN rail mounting) Backlit LCD display Rated supply voltage: 230-400 VAC Pulse output: 100Wh Phase/neutral inversion protection Detection of connection errors Measurement accuracy: 1 % Bidirectional (energy consumption and production) E27, E33, E45 only Active energy: Class 1 (IEC/EN 62053-21) class B (EN 50470) 4850 3003 E20 63A direct no no three phase kwh meter 4 3179.00 4850 3004 E21 63A direct no yes three phase kwh meter 4 3574.00 4850 3050 E23 80A direct yes yes three phase kwh meter 4 3983.00 4850 3054 E27 80A direct no yes three phase kwh meter 4 8837.00 4850 3005 E30 100A direct no no three phase kwh meter 7 3806.00 4850 3006 E31 100A direct no yes three phase kwh meter 7 4113.00 4850 3012 E33 100A direct yes via com three phase kwh meter 7 4788.00 Ethernet web server embedded Note MID compliant devices available on request. CT operated.../5a 4850 3012 4850 3008 E40../5A CT no no three phase kwh meter 4 2665.00 4850 3017 E43../5A CT yes via com three phase kwh meter 4 3492.00 4850 3027 E45../5A CT yes via com three phase kwh meter 4 4225.00 Mbus Pulse concentrator (modular design DIN rail mounting) COUNTIS ECi2 multi-utility pulse concentrator allows for up to 7 pulse inputs from water, gas, compressed air and electricity meters to be registered and stored. All data can be centralised via RS485 communication using MODBUS protocol. 4853 0000 Load curves are available for each of the 7 logical inputs Partial, total, daily, weekly or monthly kwh or other types of data (litres, m 3 ) Customisation by selection of the measuring unit: kwh, m 3, litres Generate event alarms (1 dedicated relay output) 230-400 VAC supply 4853 0000 ECi2 yes pulse concentrator for up to 7 inputs 4 4720.00 E-7 Above s do not include VAT. E&OE

DIRIS multi-function meters (PMD) DIRIS multi-function meters Compact and ergonomic, the DIRIS multifunction meter specially adapted for monitoring and managing electrical energy. Its communication function allows the analysis of data collected via a PLC energy management software. Compact: Compliant: Advanced: RS485: Ease of use: Panel or Din rail mount options enables easy integration into any type of electrical cabinet IEC61557-12 high-level standard for all PMDs (Performance Monitoring Devices) Programmable input and output as standard including pulse metering, alarm report and pulse output Communication permits the extraction of data and device configuration remotely. Permits easy navigation via direct keys and easy to read backlit LCD screen display Metering new Multi-measurement (model dependant) Current - Instantaneous and maximum average I1, I2, I3, In Voltage and frequency - Instantaneous V1, V2, V3, U12, U23, U31,F Frequency - 45~65 Hz Power - Instantaneous and maximum average 3P, ΣP, 3Q, ΣQ, 3S, ΣS Power factor - Instantaneous 3PF, ΣPF and maximum average Energy - Active energy: +/- kwh Reactive energy: +/- kvarh - hours Harmonic analysis - THD Current, voltage, phase-to-phase voltage Events - Alarms on all electrical values Energy accuracy - Active energy class 0.55 4825 0010 auxiliary number type power plug-in description supply modules DIRIS A10 multi-function meter DIN rail mount The DIRIS A10 is a modular multifunction meter for measuring electrical values in low voltage networks. It allows all electrical parameters to be displayed and utilised for communication and/ or output functions. Navigation is via 5 direct access keys and easy to read screen display Harmonic analysis up to (level 51) Integrated temperature sensor Detects wiring errors to automatically correct CT installation errors Dual tariff selection Dimensions: 72 x 90 mm x 64 mm deep 4825 0010 110-277 VAC 4 A10 72 x 90 mm DIN rail mount multifunction meter 2818.00 4825 0011 110-277 VAC 4 A10 as above with RS485 MODBUS comms 2991.00 Available in light grey on request DIRIS A14 multi-function meter DIN rail mount 4825 0020 DIRIS A14 with MID certification provide the guaranteed accuracy required for applications in which sub-billing of the electrical energy consumed is necessary. A14 Bi-directional metering (four quadrants) function is for measuring energy production or consumption. Auxiliary power supply : Self supply Display of electrical values ( I,U,V, ΣP, ΣQ, ΣQ, ΣS, PF) and P + load curve Over a 7 day period via communication Total and partial metering +/- Kwh +/- Kvarh Harmonic analysis (via comm) up to level 63 Multi traffic functions (via comm.) selection of one our of four billing tariffs Dimensions: 72 x 90 mm x 64 mm deep 4825 0020 50 to 460 VAC +/- 15% 4 A14 72 x 90 mm MID + RS485 MODBUS comm. 3956.00 DIRIS A17 multi-function meter panel mount The DIRIS A17 compact meter includes a programmable input and output as standard on all versions, functions include pulse metering, alarm report and pulse output. Navigation is via 4 direct access keys and easy to read screen display Harmonic analysis up to (level 31) Dimensions: 72 x 72 mm x 60 mm deep 4825 0101 4825 0101 220-277 VAC A17 72 x 72 mm panel mount multifunction meter 2811.00 4825 0102 220-277 VAC A17 as above with RS485 MODBUS comms 3390.00 Above s do not include VAT. E&OE E-8

DIRIS multi-function meters (PMD) auxiliary number type power plug-in description supply modules DIRIS A20 multi-function meter panel mount DIRIS A20 multifunction meters are panel mounted measurement units which ensure the user has access to all the measurements required for successfully carrying out energy efficiency projects and ensuring the electric distribution is monitored. 4825 0200 Detects wiring errors to automatically correct CT installation errors Hours metering Harmonic analysis up to (level 51) Accepts 1 x functional plug-in module for 1 x output or RS485 MODBUS communication Dimensions: 96 x 96 mm x 60 mm deep 4825 0200 110-400 VAC 1 A20 96 x 96 mm panel mount multi-function meter 2959.00 DIRIS A40/41 multi-function meter panel mount The Diris A40/41 series provides access to all measurements required for successfully carrying out energy efficiency projects for electrical distribution monitoring, the units are easily customisable or upgradeable through optional plug-in modules (up to 4). A41 has CT current input for measuring neutral current as well Provides accurate instantaneous, average and maximum levels of most important measurements Metering Active, reactive and apparent energy with hours Harmonic analysis up to (level 53) Provide load curves of Active/Reactive power with voltages and frequency Internal temperature and external temperature (via 3 PT100 sensors) Accepts 4 x functional plug-in modules Dimensions: 96 x 96 mm x 60 mm deep 4825 0201 110-400 VAC 4 A40 96 x 96 mm panel mount multi-function meter 5229.00 4825 0202 110-400 VAC 4 A41 as above with neutral monitoring 7537.00 4825 1201 12-48 VDC 4 A40 96 x 96 mm panel mount multi-function meter 8239.00 4825 1202 12-48 VDC 4 A41 as above with neutral monitoring 10841.00 4825 0201 DIRIS A60 multi-function meter energy monitoring and event analysis The Diris A60 incorporates all functions of the A40 with additional enhanced data logging functions, recording curves for quality events. All information can be analysed remotely using freely downloadable analysis software from the SOCOMEC website. Indicates current and voltage imbalances and tangent φ Stores load curves (60 days with intervals of 10 mins) for active, reactive, apparent power Detects and stores last 40 events - overvoltage, voltage dips, cut-offs, overcurrent for each stored event A60 records the relevant RMS 10ms interval curves Dimensions: 96 x 96 mm x 60 mm deep 4825 0207 110-400 VAC 4 A60 96 x 96 mm panel mount multi-function meter 8639.00 Accessories for DIRIS meters Plug-modules (for customisation or upgrading of meters) type function description for model 4825 0080 1 x output plug-in optional modules A20 335.00 4825 0082 RS485 MODBUS comms plug-in optional modules A20 481.00 4825 0094 4825 0090 2 configurable pulse outputs plug-in optional modules A40/41/A60 481.00 4825 0092 RS485 MODBUS comms plug-in optional modules A40/41/A60 682.00 4825 0093 2 Analog outputs plug-in optional modules A40/41/A60 1349.00 4825 0094 2 inputs / 2 outputs plug-in optional modules A40/41/A60 755.00 4825 0205 Sub D9 PROFIBUS DP comm plug-in optional modules A40/41 4459.00 4825 0097 Memory plug-in optional modules A40/41 682.00 4825 0203 Ethernet communication with Embedded Webserver function A40/41/A60 2728.00 4825 0204 Ethernet + RS485 MODBUS with Embedded Webserver function A40/41/A60 3183.00 4825 0089 IP65 protection IP65 protection cover for DIRIS meters A40/41/A60 255.00 E-9 Above s do not include VAT. E&OE

Introducing Digiware (measurement and monitoring for electrical installations) The DIRIS Digiware is a multi-circuit power monitoring device that is the most effective solution for metering consumption. Measuring and monitoring the quality of electrical energy in industrial and commercial applications. Can monitor several circuits via a single current measurement module thanks to independent current inputs Implementation in a quarter of the time vs existing metering technologies Accuracy as per standard IEC 61557-12 (Class 0.5) Installation of measurement modules and current sensors at the closest point to the load Compact and flexible design: suitable for new and existing installations including panels with space restrictions Build a system: Metering Display/ No display module Voltage measurement module Multiple current measurement modules Current sensors The solution for Industry Building Infrastructure Local authority Advantages Multi-circuit Global accuracy class 0.5 Cost effective and flexible Plug & play 4829 0101 new 4829 0201 type Control and power supply interface description Power supply 24 VDC (required see page B-56) Communication via RS485 Modbus and Digiware BUS C-31 data Interface system No-display mode Centralises all of the systems' data on MODBUS RS485 module width 4829 0101 modular centralisation unit 18 mm 1809.00 D-40/50 centralisation and display of data panel mount 96 x 96 mm High-resolution LCD display Local view of data from the voltage and current modules Keys on the front face for direct access to, measurement data,circuit selection,device configuration Power supply 24 VDC (required see page B-56) D-40 4829 0199 centralisation unit with multi-point display and RS485 output 4650.00 D-50 4829 0201 centralisation unit with multi-point display and Ethernet communication (Modbus TCP) 5125.00 C-32 range extending repeater Required when Digiware bus length exceeds 100m Maximum bus length 300m (2 repeaters) Power supply 24 VDC (required see page B-56) 4829 0103 range extending repeater 18 mm 2171.00 Note: For RJ45 connecting cables for above see E-12 E-10

Digiware power monitoring / energy management new Voltage measurement modules 1 single voltage measurement point for the entire system. A complete,dedicated solution for : metering,voltage monitoring,quality analysis of the voltage RJ45 bus allows you measurement of voltage as well as supply power to all connected devices 3 phase voltage and frequency monitoring type description module width 4829 0106 U-10 metering module 4829 0105 modular voltage measurement metering module 18 mm 2026.00 U-20 monitoring module (as above but with additional 3ph THDu monitoring) 4829 0106 modular voltage measurement monitoring module (harmonics) 18 mm 2713.00 U-30 analysis module (all electrical parameters including history of average values) 4829 0102 modular voltage measurement analysis module 18 mm 3083.00 Current measurement modules 4829 0112 TE... Allocates the load to be measured or to monitor independent current inputs i.e three-phase load and 3 single-phase loads. A complete,dedicated solution for : metering,voltage monitoring,quality analysis of the voltage RJ45 and RJ12 rapid connection and automatically configures connected current sensors Wiring errors are also prevented and implementation is simplified Metering: ± kwh, ± kvarh, kvah Multi-measurement: I1, I2, I3, In, ΣP, ΣQ, ΣS, ΣPF type I-30/60 metering modules description current inputs module width 4829 0110 I-30 modular current measurement metering module 3 18 mm 2171.00 4829 0112 I-60 modular current measurement metering module 6 36 mm 3627.00 I-31/61 metering and load curve modules 4829 0111 I-31 modular current measurement metering module 3 18 mm 3024.00 4829 0113 I-61 modular current measurement metering module 6 36 mm 5065.00 I-35/45 analysis module (all electrical parameters including history of average values) 4829 0130 I-35 modular current measurement analysis module 3 18 mm 4174.00 4829 0131 I-45 modular current measurement analysis module 4 27 mm 7959.00 Current sensors TE 90 Various types of current sensors can be connected to the Solid TE,split-core TR,TF current sensors. These sensors automatically recognizes the sensor size and type and can be adapted to all types of new and existing installations. Plug and play RJ12 connections (for ease of wiring preventing wiring errors) Automatic detection of sensor type and current rating type model nominal pitch hole size description current (A) (mm) (mm) TR... TF... TE - solid current sensors Suitable for new installations - match the pitch of protective devices 4829 0500 TE-18 5 20 solid current sensor 18 Ø 8.6 377.00 4829 0501 TE-18 25 63 solid current sensor 18 Ø 8.6 387.00 4829 0502 TE-25 40 160 solid current sensor 25 13.5 435.00 4829 0503 TE-35 63 250 solid current sensor 35 21 484.00 4829 0504 TE-45 160 630 solid current sensor 45 31 677.00 4829 0505 TE-55 400 1000 solid current sensor 55 41 869.00 4829 0506 TE-90 600 2000 solid current sensor 90 64 1584.00 TR - split-core current sensors 4829 0551 TR-10 25 75 split-core current sensors Ø 10 1174.00 4829 0552 TR-16 32 100 split-core current sensors Ø 16 1401.00 4829 0553 TR-24 63 200 split-core current sensors Ø 24 1785.00 4829 0554 TR-36 200 600 split-core current sensors Ø 36 2027.00 TF - flexible current sensors (Rogowski coil) 4829 0570 TF-55 150 600 flexible current sensors Ø 55 3952.00 4829 0571 TF-120 400 2000 flexible current sensors Ø 120 4434.00 4829 0572 TF-300 600 16000 flexible current sensors Ø 800 4916.00 E-11 Above s do not include VAT. E&OE

Digiware power monitoring / energy management new type model description Cables and accessories for current sensor RJ12 current sensor connection Automatic detection of ratings Identification of cables by colour-coding Disconnection of the current sensor secondary under load cable length pack size Metering RJ12 RJ45 4829 0581 RJ12 current sensor connection cable 0.2 m (3x cables) 158.00 4829 0595 RJ12 current sensor connection cable 0.5 m (3x cables) 189.00 4829 0583 RJ12 current sensor connection cable 1.0 m (3x cables) 237.00 4829 0584 RJ12 current sensor connection cable 2.0 m (3x cables) 349.00 4829 0593 RJ12 current sensor connection cable 1.0 m (6x cables) 478.00 4829 0594 RJ12 current sensor connection cable 2.0 m (6x cables) 697.00 4829 0601 RJ12 current sensor cable + 50 connectors 50 m (cable roll) 3284.00 RJ45 current sensor connection Interconnection of I and U modules via Digiware bus Auto-configuration of parameters: Network and load type - addressing of devices connected to the bus 4829 0181 RJ45 Digiware bus connection cable 0.1 m 59.00 4829 0182 RJ45 Digiware bus connection cable 0.5 m 84.00 4829 0183 RJ45 Digiware bus connection cable 1.0 m 111.00 4829 0184 RJ45 Digiware bus connection cable 2.0 m 171.00 4829 0185 RJ45 current sensor cable + 50 connectors 50 m (cable roll) 5343.00 Maximum cable distance between current measurement modules and current sensors is 10 m 4829 0599 5A/CT adapter (measurement >1000 A) 677.00 4829 0598 coupling link for interconnecting sensors staggered or linear mounted (30pcs) 422.00 4829 0600 sealable cover (guarantees the immunity of sensor connection) (20pcs) 422.00 4829 0302 Communication gateways wireless and cabled RS485 to Ethernet DIRIS G communication gateways communicate all information from metering and measurement devices wirelessly or via RS485 bus, centralised in a single device and made available on the Ethernet network via Modbus TCP. The gateway has an embedded WEBVIEW web server, permitting real time monitoring of electrical values and analysis of consumption data. Plug and Play automatic detection and addressing of measurement and metering devices Automatic recording and storage of measurements and consumption data, sending of alarms Ethernet/RS485 Modbus communication with embedded WEBVIEW power monitoring type description module width Consumption history (Webview) DIRIS G-50 4829 0302 power and energy monitoring communication gateway 62 mm 12206.00 DIRIS G-60 wireless (radio frequency) and cabled RS485 to Ethernet 4829 0303 power and energy monitoring communication gateway 62 mm 14099.00 Power monitoring device (stand alone unit) The DIRIS B-30 is a PMD in modular format that communicates wirelessly or via RS485. The 4 RJ independent current inputs allows it to manage several types and number of circuits i.e 4 single-phase loads or 1 three phase load + 1 single-phase load (compatible G-50 /60). 4829 0000 B-30 RS RS485 MODBUS communication 54 mm 5886.00 4829 0002 B-30 RF Radio Frequency communication (wireless) 54 mm 6857.00 B-30 RS 4829 0200 D-30 single point display for B-50 panel mount 96 x 96 mm 2713.00 4829 0280 RJ9 cable for above D-30 display unit 1.5m 89.00 4829 0281 RJ9 cable for above D-30 display unit 3.0m 131.00 Above s do not include VAT. E&OE E-12

Current transformers Made in Germany General specifications Nominal frequency: Isolation class: Nominal thermal short-time current: Maximum operating voltage: Over-current limiting factor: 50Hz (others on request) E Ith = 60 x In Um 0.72 kv FS 5 up to 1500 A nominal current MBS AG conform fully to: DIN VDE 0414/1 - DIN 42600 - IEC 61869/1+2 - VBG 4 ASR 20.3 type ratio description class VA dimensions (mm) (H) (W) (D) Tube/ring type 5A secondary - class 1 ASR 20.3 tube Ø round conductor: 21 mm 26027 50/5A tube current transformer 1 1 65 45 30 264.00 26029 60/5A tube current transformer 1 1.25 65 45 30 264.00 26031 75/5A tube current transformer 1 1.5 65 45 30 264.00 26035 100/5A tube current transformer 1 2.5 65 45 30 264.00 26041 150/5A tube current transformer 1 3.75 65 45 30 264.00 26051 200/5A tube current transformer 1 3.75 65 45 30 264.00 26046 250/5A tube current transformer 1 5 65 45 30 264.00 55013 DIN rail adaptor for above 73.00 ASK 31.3 Busbar mounted 5A secondary - class 1 ASK 31.3 Primary bar conductor: 30 x 10 / 20 x 20 mm Ø round conductor: 26 mm 7038 50/5A std current transformer 1 1 76 61 48 264.00 7039 60/5A std current transformer 1 1 76 61 48 264.00 7041 75/5A std current transformer 1 1.5 76 61 48 264.00 7045 100/5A std current transformer 1 2.5 76 61 48 264.00 7047 150/5A std current transformer 1 2.5 76 61 48 264.00 7050 200/5A std current transformer 1 5 76 61 48 264.00 7053 250/5A std current transformer 1 10 76 61 48 264.00 55011 DIN rail adaptor for above 73.00 ASK 41.4 ASK 41.4 Primary bar conductor: 40 x 10 / 30 x 10 mm Ø round conductor: 32 mm 13044 100/5A std current transformer 1 2.5 86 71 58 223.00 13048 150/5A std current transformer 1 5 86 71 58 223.00 13050 200/5A std current transformer 1 5 86 71 58 223.00 13054 250/5A std current transformer 1 10 86 71 58 223.00 13057 300/5A std current transformer 1 10 86 71 58 223.00 13062 400/5A std current transformer 1 15 86 71 58 223.00 13066 500/5A std current transformer 1 15 86 71 58 223.00 13070 600/5A std current transformer 1 15 86 71 58 223.00 13073 750/5A std current transformer 1 15 86 71 58 223.00 13077 800/5A std current transformer 1 30 86 71 58 223.00 55012 DIN rail adaptor for above 73.00 ASK 51.4 Primary bar conductor: 50 x 10 / 40 x 20 mm Ø round conductor: 44 mm ASK 51.4 16055 400/5A std current transformer 1 10 99 86 58 282.00 16060 500/5A std current transformer 1 15 99 86 58 282.00 16064 600/5A std current transformer 1 15 99 86 58 282.00 16068 750/5A std current transformer 1 15 99 86 58 282.00 16071 800/5A std current transformer 1 15 99 86 58 282.00 16075 1000/5A std current transformer 1 15 99 86 58 282.00 E-13 Above s do not include VAT. E&OE

Current transformers Made in Germany type ratio description class VA dimensions (mm) (H) (W) (D) ASK 61.4 Primary bar conductor: 60 x 10 / 50 x 20 mm Ø round conductor: 44 mm 19065 600/5A std current transformer 1 15 106 96 58 287.00 19069 750/5A std current transformer 1 15 106 96 58 287.00 19073 800/5A std current transformer 1 15 106 96 58 287.00 19076 1000/5A std current transformer 1 30 106 96 58 287.00 19085 1250/5A std current transformer 1 30 106 96 58 287.00 Metering ASK 61.4 Standard 5A secondary - class 1 ASK 81.4 Primary bar conductor: 80 x 10 / 60 x 30 mm Ø round conductor: 55 mm 21045 600/5A std current transformer 1 10 124 120 58 469.00 21049 750/5A std current transformer 1 15 124 120 58 469.00 21053 800/5A std current transformer 1 15 124 120 58 469.00 21056 1000/5A std current transformer 1 15 124 120 58 469.00 21064 1250/5A std current transformer 1 15 124 120 58 469.00 21072 1600/5A std current transformer 1 30 124 120 58 469.00 ASK 103.41 ASK 101.4 Primary bar conductor: 100 x 10 / 80 x 30 mm Ø round conductor: 70 mm 22055 1250/5A std current transformer 1 30 144 130 40 532.00 22062 1600/5A std current transformer 1 30 144 130 40 532.00 22070 2000/5A std current transformer 1 30 144 130 40 532.00 ASK 103.3 Primary bar conductor: 100 x 30 / 80 x 50 mm Ø round conductor: 85 mm 23058 1600/5A std current transformer 1 30 188 172 52 578.00 23062 2000/5A std current transformer 1 30 188 172 52 578.00 23066 2500/5A std current transformer 1 30 188 172 52 578.00 23070 3000/5A std current transformer 1 30 188 172 52 578.00 Rectangular shaped 5A secondary - class 1 ASK 41.4 ASK 103.41 Primary bar conductor: 103 x 41 mm Ø round conductor: 40 mm 97054 500/5A std current transformer 1 5 150 99 40 1343.00 97056 600/5A std current transformer 1 5 150 99 40 1382.00 97058 750/5A std current transformer 1 5 150 99 40 1421.00 97060 800/5A std current transformer 1 10 150 99 40 1464.00 97062 1000/5A std current transformer 1 15 150 99 40 1503.00 97066 1250/5A std current transformer 1 15 150 99 40 1556.00 ASK 128.4 Primary bar conductor: 128 x 38 mm Ø round conductor: 38 mm 94056 1250/5A std current transformer 1 15 178 100 40 1655.00 94058 1500/5A std current transformer 1 30 178 100 40 1846.00 94060 2000/5A std current transformer 1 30 178 100 40 1928.00 94062 2500/5A std current transformer 1 30 178 100 40 1928.00 ASK 103.3 Above s do not include VAT. E&OE E-14

Current transformers Made in Germany type ratio description class VA dimensions (mm) (H) (W) (D) ASK 41.4 Class 0.5 5A secondary ASK 41.4 (class 0.2 available on request) Primary bar conductor: 40 x 10 / 30 x 10mm Ø round conductor: 32 mm 13085 200/5A std current transformer 0.5 5 86 71 40 492.00 13086 250/5A std current transformer 0.5 5 86 71 40 492.00 13087 300/5A std current transformer 0.5 10 86 71 40 492.00 13088 400/5A std current transformer 0.5 10 86 71 40 492.00 13089 500/5A std current transformer 0.5 15 86 71 40 492.00 13090 600/5A std current transformer 0.5 15 86 71 40 492.00 ASK 51.4 Primary bar conductor: 50 x 10 / 40 x 20mm Ø round conductor: 44 mm 16154 600/5A std current transformer 0.5 15 99 86 58 605.00 16203 750/5A std current transformer 0.5 15 99 86 58 605.00 16033 800/5A std current transformer 0.5 15 99 86 58 605.00 16036 1000/5A std current transformer 0.5 15 99 86 58 605.00 ASK 61.4 Primary bar conductor: 60 x 10 / 50 x 20mm Ø round conductor: 44 mm 19031 800/5A std current transformer 0.5 15 106 96 58 669.00 19034 1000/5A std current transformer 0.5 15 106 96 58 669.00 19040 1250/5A std current transformer 0.5 15 106 96 58 669.00 ASK 103.3 ASK 81.4 Primary bar conductor: 80 x 10 / 60 x 30mm Ø round conductor: 55 mm 21023 1000/5A std current transformer 0.5 15 124 120 58 905.00 21029 1250/5A std current transformer 0.5 15 124 120 58 905.00 21035 1600/5A std current transformer 0.5 15 124 120 58 905.00 ASK 103.3 Primary bar conductor: 100 x 30 / 80 x 50mm Ø round conductor: 85 mm 23026 1600/5A std current transformer 0.5 15 188 172 35 1433.00 23029 2000/5A std current transformer 0.5 30 188 172 35 1433.00 23032 2500/5A std current transformer 0.5 30 188 172 35 1433.00 23035 3000/5A std current transformer 0.5 30 188 172 35 1433.00 WSK 40 Primary wound 5A secondary - class 1 WSK 30 primary wound 30022 5/5A wound current transformer 1 5 79 61 35 737.00 30024 10/5A wound current transformer 1 5 79 61 35 737.00 30026 15/5A wound current transformer 1 5 79 61 35 737.00 30028 20/5A wound current transformer 1 5 79 61 35 737.00 WSK 40 primary wound 31070 25/5A wound current transformer 1 10 89 71 45 860.00 31074 30/5A wound current transformer 1 10 89 71 45 860.00 Summation 5A secondary - class 1 KSU 2/3 summation 41015 5+5/5A wound current transformer 1 10 94 127 57 1210.00 41031 5+5+5/5A wound current transformer 1 10 94 127 57 1914.00 SUSK 4 SUSK 4 summation 40027 5+5+5+5/5A wound current transformer 1 10 137 156 65 2394.00 E-15 Above s do not include VAT. E&OE

Current transformers Made in Germany type ratio description class VA dimensions (mm) (H) (W) (D) ASK 41.4 Class 1 ASK 41.4 1A secondary Primary bar conductor: 40 x 10 / 30 x 10 mm Ø round conductor: 32 mm 13239 75/1A std current transformer 1 2.5 86 71 40 346.00 13244 100/1A std current transformer 1 2.5 86 71 40 346.00 13248 150/1A std current transformer 1 5 86 71 40 346.00 13250 200/1A std current transformer 1 5 86 71 40 346.00 13254 250/1A std current trans former 1 10 86 71 40 346.00 13257 300/1A std current transformer 1 10 86 71 40 346.00 13262 400/1A std current transformer 1 15 86 71 40 346.00 13266 500/1A std current transformer 1 15 86 71 40 346.00 13270 600/1A std current transformer 1 15 86 71 40 346.00 Metering ASK 61.4 ASK 103.3 55012 DIN rail adaptor for above 73.00 ASK 51.4 Primary bar conductor: 50 x 10 / 40 x 20 mm Ø round conductor: 44 mm 16260 500/1A std current transformer 1 15 99 86 58 282.00 16264 600/1A std current transformer 1 15 99 86 58 282.00 16268 750/1A std current transformer 1 15 99 86 58 282.00 16271 800/1A std current transformer 1 15 99 86 58 282.00 16275 1000/1A std current transformer 1 15 99 86 58 282.00 ASK 61.4 Primary bar conductor: 60 x 10 / 50 x 20 mm Ø round conductor: 44 mm 19265 600/1A std current transformer 1 15 106 96 58 287.00 19269 750/1A std current transformer 1 15 106 96 58 287.00 19273 800/1A std current transformer 1 15 106 96 58 287.00 19277 1000/1A std current transformer 1 30 106 96 58 346.00 19285 1250/1A std current transformer 1 30 106 96 58 287.00 ASK 81.4 Primary bar conductor: 80 x 10 / 60 x 30 mm Ø round conductor: 55 mm 21253 800/1A std current transformer 1 15 124 120 40 795.00 21256 1000/1A std current transformer 1 15 124 120 40 795.00 21264 1250/1A std current transformer 1 15 124 120 40 795.00 21272 1600/1A std current transformer 1 30 124 120 40 795.00 ASK 103.3 plug-in Primary bar conductor: 100 x 30 / 80 x 50 mm Ø round conductor: 85 mm 23251 1250/1A std current transformer 1 30 188 172 35 673.00 23258 1600/1A std current transformer 1 30 188 172 35 673.00 23262 2000/1A std current transformer 1 30 188 172 35 673.00 23266 2500/1A std current transformer 1 30 188 172 35 673.00 23270 3000/1A std current transformer 1 30 188 172 35 673.00 Above s do not include VAT. E&OE E-16

Current transformers Made in Germany The CTB range with "cage clamp " termination (uneffected by vibration and shock) offers a higher maximum operating voltage (Um < 1,2 kv) and increased isolation test voltage (6 kv Ueff, 1 min., 50 Hz) as well as increased ambient temperature range (-5 C < T < +50 C). cage clamp General specifications Nominal thermal current Icth: 1.2 x In (continuous) Therm. nominal short-time current Ith: 60 x In, 1 sec. Maximum operating voltage Um: 1.2 kv Isolation test voltage: 6 kv, Ueff, 50 Hz, 1 min. Nominal rated frequency: 50 Hz Isolation class: E UL-zertifiziert - Certificate Number - 20100426-E336996, DIN EN 61869 part 1+2 Ø round dimensions (mm) type ratio description class VA conductor (H) (W) (D) Current transformers with screwless connection technology CTB 31.35 5A secondary class 1 CTB 31.35 Primary bar conductor: 30 x 10 / 25 x 12 / 20 X 20 mm 50-0002 100/5A 25.7 mm std current transformer 1 2.5 81 60 52 287.00 50-0004 150/5A 25.7 mm std current transformer 1 5 81 60 52 287.00 50-0005 200/5A 25.7 mm std current transformer 1 5 81 60 52 287.00 50-0006 250/5A 25.7 mm std current transformer 1 5 81 60 52 287.00 50-0008 300/5A 25.7 mm std current transformer 1 10 81 60 52 287.00 50-0010 400/5A 25.7 mm std current transformer 1 10 81 60 52 287.00 50-0012 500/5A 25.7 mm std current transformer 1 10 81 60 52 287.00 50-0014 600/5A 25.7 mm std current transformer 1 10 81 60 52 287.00 CTB 41.35 5A secondary class 1 CTB 41.35 Primary bar conductor: 40 x 10 / 30 x 15 mm 50-0058 400/5A 31.8 mm std current transformer 1 5 91 70 52 337.00 50-0060 500/5A 31.8 mm std current transformer 1 10 91 70 52 337.00 50-0062 600/5A 31.8 mm std current transformer 1 10 91 70 52 337.00 50-0064 750/5A 31.8 mm std current transformer 1 10 91 70 52 337.00 50-0066 800/5A 31.8 mm std current transformer 1 10 91 70 52 337.00 50-0068 1000/5A 31.8 mm std current transformer 1 10 91 70 52 337.00 CTB 51.35 5A secondary class 1 CTB 61.35 Primary bar conductor: 50 x 10 / 40 x 30 mm 50-0113 750/5A 43.7 mm std current transformer 1 10 105 85 52 387.00 50-0115 800/5A 43.7 mm std current transformer 1 10 105 85 52 387.00 50-0117 1000/5A 43.7 mm std current transformer 1 10 105 85 52 387.00 50-0119 1250/5A 43.7 mm std current transformer 1 10 105 85 52 387.00 CTB 61.35 5A secondary class 1 Primary bar conductor: 63 x 10 / 50 x 30 mm 50-0159 800/5A 43.7 mm std current transformer 1 10 115 95 52 455.00 50-0161 1000/5A 43.7 mm std current transformer 1 10 115 95 52 455.00 50-0163 1250/5A 43.7 mm std current transformer 1 10 115 95 52 455.00 50-0167 1600/5A 43.7 mm std current transformer 1 10 115 95 52 455.00 CTB 81.35 CTB 81.35 5A secondary class 1 Primary bar conductor: 80 x 10 / 60 x 30 mm 50-0198 1000/5A 54.7 mm std current transformer 1 10 135 120 52 578.00 50-0200 1250/5A 54.7 mm std current transformer 1 10 135 120 52 578.00 50-0204 1600/5A 54.7 mm std current transformer 1 10 135 120 52 578.00 50-0206 2000/5A 54.7 mm std current transformer 1 10 135 120 52 578.00 CTB 101.35 5A secondary class 1 Primary bar conductor: 100 x 10 / 80 x 30 mm 50-0240 1250/5A 70 mm std current transformer 1 10 147 130 52 746.00 50-0244 1600/5A 70 mm std current transformer 1 15 147 130 52 746.00 50-0246 2000/5A 70 mm std current transformer 1 15 147 130 52 746.00 50-0248 2500/5A 70 mm std current transformer 1 15 147 130 52 746.00 CTB 101.35 Accessories for above CTB 55015 DIN rail mounting adaptor for CTB 31+41 73.00 55021 quick fix quick action busbar fastening support clip all CTs 46.00 E-17 Above s do not include VAT. E&OE

Splitcore current transformer Made in Germany The split measuring system facilitates a simple installation into existing panel boards without additional mounting requirements. Simply open the locking mechanism of the current transformer place around the primary conductor and lock ensuring that the circuit is closed. Once the secondary conductors are connected, the unit is ready for operation. General specifications Nominal frequency: Isolation class: Nominal thermal short-time current: Maximum operating voltage: Over-current limiting factor: 50Hz (others on request) E Ith = 60 x In Um 0.72 kv FS 5 up to 1500 A nominal current Metering MBS AG conform fully to: DIN VDE 0414/1 - DIN 42600 - DIN EN 60044/1 - VBG 4 type ratio round conductor description class VA KBU 23 split core 5A secondary - class 1/3 KBU 23 Dimensions: Primary bar conductor: Round conductor: (H) 106 x (W) 93 x (D) 58 mm 20 x 30 mm max. Split core 80048 100/5A split core split-core current transformer 3 1.25 1363.00 80030 150/5A split core split-core current transformer 3 1.5 1363.00 80031 200/5A split core split-core current transformer 3 1.5 1363.00 80044 250/5A split core split-core current transformer 1 1.5 1363.00 KBU 58 split core 5A secondary - class 1 Dimensions: Primary bar conductor: (H) 158 x (W) 125 x (D) 58 mm 50 x 80 mm max. KBU 58 80061 250/5A split core split-core current transformer 1 1.5 1586.00 80062 300/5A split core split-core current transformer 1 2.5 1586.00 80063 400/5A split core split-core current transformer 1 2.5 1586.00 80064 500/5A split core split-core current transformer 1 5 1586.00 80065 600/5A split core split-core current transformer 1 5 1586.00 80067 800/5A split core split-core current transformer 1 7.5 1586.00 80068 1000/5A split-core split-core curren t transformer 1 10 1586.00 KBU 812 split core 5A secondary - class 1 Dimensions: Primary bar conductor: (H) 198 x (W) 155 x (D) 58 mm 80 x 12 mm max. 80098 1000/5A split core split-core current transformer 1 10 1880.00 80100 1250/5A split core split-core current transformer 1 15 1880.00 KBU 816 split core 5A secondary - class 1 Dimensions: Primary bar conductor: (H) 243 x (W) 195 x (D) 79 mm 80 x 160 mm max. KBU 816 80147 1600/5A split core split-core current transformer 1 15 2216.00 80149 2000/5A split core split-core current transformer 1 15 2216.00 80151 2500/5A split core split-core current transformer 1 15 2216.00 80153 3000/5A split core split-core current transformer 1 30 2216.00 80155 4000/5A split core split-core current transformer 1 30 2216.00 80157 5000/5A split core split-core current transformer 1 30 2216.00 Above s do not include VAT. E&OE E-18

Split-core JS series split-core 5A or 1A secondary from sensed primary current for metering applications. They can be used for power meters, distribution systems, control panels, switchgear and other equipment. Designed to install to live power lines without disconnection of the power source. Built-in over voltage protection provides a safe, fast and cost-effective installation. Light weight, compact dimensions Simple installation Built-in over-voltage protection Incorporated cable tie support for securing to cable Accuracy : class 0.5/1.0/3.0 Output terminals : 2 x M3 screw terminals with terminal cover Overload withstand : 720V (0.72 kv) Compliant with : IEC/EN60044-1 & IEC61010-1 Operating temperature : -24 C to 55 C Test voltage : 3kV for 1 minute type ratio round conductor description class VA Miniature split-core 5A secondary JS24S dimensions: (H) 74.5 x (W) 45 x (D) 33.7 mm JS24S-100/5A 100/5A Ø 24 mm mini split-core current transformer 3 1.5 861.00 JS24S-150/5A 150/5A Ø 24 mm mini split-core current transformer 3 1.5 861.00 JS24S-200/5A 200/5A Ø 24 mm mini split-core current transformer 1 0.5 861.00 JS24S-250/5A 250/5A Ø 24 mm mini split-core current transformer 1 0.5 861.00 JS24S-300/5A 300/5A Ø 24 mm mini split-core current transformer 1 0.5 861.00 JS24S-400/5A 400/5A Ø 24 mm mini split-core current transformer 1 0.5 861.00 JS17S JS36S dimensions: (H) 91.4 x (W) 57.1 x (D) 40.2 mm JS36S-400/5A 400/5A Ø 36 mm mini split-core current transformer 1 2.5 1133.00 JS36S-500/5A 500/5A Ø 36 mm mini split-core current transformer 1 2.5 1133.00 JS36S-600/5A 600/5A Ø 36 mm mini split-core current transformer 1 5.0 1133.00 Miniature split-core 1A secondary JS17S dimensions: (H) 64 x (W) 33 x (D) 35.8 mm JS17S-60/1A 60/1A Ø 17 mm mini split-core current transformer 3 0.2 820.00 JS17S-75/1A 75/1A Ø 17 mm mini split-core current transformer 3 0.5 820.00 JS24S dimensions: (H) 75 x (W) 45 x (D) 34 mm JS24S-100/1A 100/1A Ø 24 mm mini split-core current transformer 3 1.0 820.00 JS24S-125/1A 125/1A Ø 24 mm mini split-core current transformer 3 1.0 820.00 JS24S-150/1A 150/1A Ø 24 mm mini split-core current transformer 3 1.0 820.00 JS24S-200/1A 200/1A Ø 24 mm mini split-core current transformer 1 0.5 820.00 JS24S-250/1A 250/1A Ø 24 mm mini split-core current transformer 1 1.0 820.00 JS24S-300/1A 300/1A Ø 24 mm mini split-core current transformer 1 1.5 820.00 JS24S JS36S dimensions: (H) 91 x (W) 57 x (D) 40.2 mm JS36S-400/1A 400/1A Ø 36 mm mini split-core current transformer 0.5 0.5 1072.00 JS36S-500/1A 500/1A Ø 36 mm mini split-core current transformer 0.5 0.5 1072.00 JS36S-600/1A 600/1A Ø 36 mm mini split-core current transformer 0.5 0.5 1072.00 RMS series - output current transducers (4-20mA) RMS Series Split-core Current Transducers are designed for energy management with a convenient connection to electronic submeters, current measurement in distributed power line carriers (PLCs) or remote controls such as SCADA software for automation and supervision. Max. permissable current : 120% (continuous), 150% (1 min.) Output : 4-20mA (average)/0-rated current (load resistance: 600Ω at P/S : 24V) Accuracy / linearity : ±2% FS. Dynamic range 1:100 at 50/60Hz sinewave Output terminals : 2 x M3 screw terminals with terminal cover Sensor supply voltage : 24 VDC loop power Operating condition : -20 C to 50 C 85% RH (any direction installable) JC16F dimensions: (H) 55 x (W) 29.5 x (D) 31 mm JC16F-5-RMS 0-5A Ø 16 mm 4-20mA split-core current transducer 1761.00 JC16F-10-RMS 10A Ø 16 mm 4-20mA split-core current transducer 1761.00 JC16F-25-RMS 25A Ø 16 mm 4-20mA split-core current transducer 1761.00 JC16F-50-RMS 50A Ø 16 mm 4-20mA split-core current transducer 1761.00 JC16F-100-RMS 100A Ø 16 mm 4-20mA split-core current transducer 1761.00 JS36S JC24S dimensions: (H) 75 x (W) 45 x (D) 34 mm JC24S-250-RMS 250A Ø 24 mm 4-20mA split-core current transducer 2680.00 JC36S dimensions: (H) 91 x (W) 57 x (D) 40.2 mm JC36S-500-RMS 500A Ø 36 mm 4-20mA split-core current transducer 3292.00 E-19 Above s do not include VAT. E&OE

Current transformers / DC shunts IMN1... IRB1... IRB3... type ratio description class VA IMN1 ring type transformers Ø round conductor: 32 mm dimensions (mm) (H) (W) (D) IMN1/05 50/5A ring current transformer 3 1.3 87 64 42 128.00 IMN1/06 60/5A ring current transformer 3 1.3 87 64 42 128.00 IMN1/07 75/5A ring current transformer 3 1.3 87 64 42 130.00 IMN1/10 100/5A ring current transformer 1 2.5 87 64 42 130.00 IMN1/12 125/5A ring current transformer 1 2.5 87 64 42 130.00 IMN1/15 150/5A ring current transformer 1 3.8 87 64 42 131.00 IMN1/16 160/5A ring current transformer 1 3.8 87 64 42 131.00 IMN1/20 200/5A ring current transformer 1 5 87 64 42 135.00 IMN1/25 250/5A ring current transformer 1 7.5 87 64 42 138.00 IMN2 Primary bar conductor: 40 x 12.5 mm Ø round conductor: 38 mm IMN2/16 160/5A ring current transformer 1 10 99 75 42 159.00 IMN2/20 200/5A ring current transformer 1 10 99 75 42 159.00 IMN2/25 250/5A ring current transformer 1 10 99 75 42 159.00 IMN2/30 300/5A ring current transformer 1 15 99 75 42 162.00 IMN2/40 400/5A ring current transformer 1 25 99 75 42 168.00 IMN2/50 500/5A ring current transformer 1 30 99 75 42 174.00 IMN2/60 600/5A ring current transformer 1 30 99 75 42 181.00 IBR1 Primary bar conductor: 60 x 20 mm Ø round conductor: 60 mm IBR1/06 600/5A ring current transformer 0.5 7.5 115 104 45 253.00 IBR1/08 800/5A ring current transformer 0.5 15 115 104 45 266.00 IBR1/10 1000/5A ring current transformer 0.5 30 115 104 45 280.00 IBR1/12 1250/5A ring current transformer 0.5 30 115 104 45 297.00 IBR3 Primary bar conductor: 100 x 30 mm Ø round conductor: 110 mm IBR3/12 1250/5A ring current transformer 0.5 15 170 152 45 367.00 IBR3/16 1600/5A ring current transformer 0.5 30 170 152 45 382.00 IBR3/20 2000/5A ring current transformer 0.5 30 170 152 45 417.00 IBR3/25 2500/5A ring current transformer 0.5 30 170 152 45 446.00 IBR3/30 3000/5A ring current transformer 0.5 30 170 152 45 475.00 IBNP primary wound IBNP/05 5/5A primary wound CT 0.5 5 111 68 43 244.00 IBNP/10 10/5A primary wound CT 0.5 5 111 68 43 244.00 IBNP/15 15/5A primary wound CT 0.5 5 111 68 43 244.00 IBNP/20 20/5A primary wound CT 0.5 5 111 68 43 244.00 IBNP/25 25/5A primary wound CT 0.5 5 111 68 43 244.00 IBNP/30 30/5A primary wound CT 0.5 5 111 68 43 254.00 IBNP/40 40/5A primary wound CT 0.5 5 111 68 43 358.00 Metering ACN10-5 ACN30-5 B C D E A ACN60-5 Above s do not include VAT. E&OE DC shunts 50mV output Accuracy: 0.5% Overload: 120% continuously, 1000% for 5 seconds dimensions (mm) A B C D E ACN01-5 10A 50mV 105 25 35 14.3 5.5 376.00 ACN02-5 20A 50mV 105 25 35 14.3 5.5 376.00 ACN03-5 30A 50mV 105 25 35 14.3 5.5 376.00 ACN04-5 40A 50mV 105 25 35 14.3 5.5 376.00 ACN05-5 50A 50mV 105 25 35 19 9.5 421.00 ACN06-5 60A 50mV 105 25 35 19 9.5 421.00 ACN08-5 80A 50mV 105 25 35 19 9.5 421.00 ACN10-5 100A 50mV 105 25 35 19 9.5 421.00 ACN15-5 150A 50mV 105 25 35 19 14.3 485.00 ACN20-5 200A 50mV 105 25 35 24.5 16 549.00 ACN25-5 250A 50mV 135 40 50 50.8 12.7 888.00 ACN30-5 300A 50mV 135 40 50 50.8 12.7 888.00 ACN40-5 400A 50mV 135 50 50 38 31.5 1192.00 ACN50-5 500A 50mV 135 50 50 38 31.5 1501.00 ACN60-5 600A 50mV 135 65 50 38 31.5 1501.00 ACN75-5 750A 50mV 135 65 50 38 31.5 1938.00 ACN80-5 800A 50mV 135 75 50 38 31.5 1938.00 ACN100-5 1000A 50mV 135 105 50 38 31.5 2373.00 Intermediate and larger sizes up to 10.000A available on request E-20

Analog panel instruments type range description 48mm² 72mm² 96mm Ammeters (AC) moving iron (overscale 2 x In) (90º movement) BEA01A 1A direct reading AC ammeter 230.00 203.00 230.00 BEA05A 5A direct reading AC ammeter 204.00 178.00 204.00 BEA10A 10A direct reading AC ammeter 204.00 178.00 204.00 BEA15A 15A direct reading AC ammeter 204.00 178.00 204.00 BEA25A 25A direct reading AC ammeter 204.00 178.00 204.00 BEA40A 40A direct reading AC ammeter 204.00 178.00 204.00 BEA40A BEA01AT 1A CT operated AC ammeter 230.00 203.00 230.00 BEA05AT 5A CT operated AC ammeter 211.00 190.00 218.00 Voltmeters (AC) moving iron (90 movement) BEV25A 250V direct reading AC voltmeter 302.00 198.00 222.00 BEV40A 400V direct reading AC voltmeter 302.00 198.00 222.00 BEV50A 500V direct reading AC voltmeter 302.00 198.00 222.00 BEV60A 600V direct reading AC voltmeter 302.00 198.00 222.00 BEV40A BEF50AP Frequency meters (90º movement) BEF50AP 45-55Hz frequency (pointer type) 110-380V 642.00 694.00 BEF50AR 47-53Hz frequency (vibrating reed) 110-230V 642.00 694.00 BEF50AR 3 47-53Hz frequency (vibrating reed) 380-500V 642.00 694.00 Maximum demand ammeters (90 movement) delay time: 15 min (standard) ERB01A /1A maximum demand ammeters 770.00 816.00 ERB05A /5A maximum demand ammeters 714.00 762.00 Combination maximum demand ammeters ERBC01A /1A com. Max. demand ammeters 1044.00 1104.00 ERBC05A /5A com. Max. demand ammeters 934.00 989.00 Power factor indicator (90 movement) 230-380V BEP05A /5A power factor indicator (0.5-1 - 0.5) 1002.00 1002.00 BEF50AR Ammeters (DC) moving coil (90 movement) BEA05D 5A direct reading DC ammeter 306.00 355.00 372.00 BEA10D 10A direct reading DC ammeter 306.00 355.00 372.00 BEA15D 15A direct reading DC ammeter 306.00 355.00 372.00 BEA20D 20A direct reading DC ammeter 306.00 355.00 372.00 BEA25D 25A direct reading DC ammeter 306.00 355.00 372.00 BEA30D 30A direct reading DC ammeter 306.00 355.00 372.00 BEV50MVD 50mV shunt operated ammeter 314.00 367.00 386.00 BEA01MAD 1mA DC (low current) ammeter 346.00 396.00 410.00 BEA20MAD 4-20mA DC (low current) ammeter 346.00 396.00 410.00 For DC shunts please refer to page E-20 BEMC01A Voltmeter (DC) (90 movement) BEV03D 0-30V DC voltmeter 306.00 355.00 372.00 BEV15D 1-150V DC voltmeter 306.00 355.00 372.00 BEV60D 150-600V DC voltmeter 306.00 355.00 372.00 BEHCD BEHCA4 Extra charges and accessories Running hour meters 144 mm² housing (90 movement) add to 96 mm² 283.00 coloured bezels R / W / B for instruments 20.00 IP65 housing front protection 288.00 spare glass 54.00 BEHCA AC running hour meter 24/110/230/380 VAC 222.00 541.00 582.00 BEHCD DC running hour meter 10-80 VDC 403.00 667.00 732.00 4 = 48 x 48 mm / 7 = 72 x 72 mm / 9 = 96 x 96 mm E-21 Above s do not include VAT. E&OE

Portable network analyser / Supervision and energy management M85050 Canvas carrying bag A portable high-performance recorder designed for energy audits. The compact design and ease of operation is ideal for analysis of networks with power quality supply. Most portable recorders follow highly complex parameter configuration and start-up processes the CIRe+ has been designed to simplifying the setup and execution of measurements and, as a consequence, the analysis of energy and audit studies. Measures main and three-phase electrical networks in 2 quadrants Measure (TRMS) true root mean square Energy meter (4 quadrants) 4 voltage and 3 current circuits Configurable via a PC application - Compatible with PowerVision software EN 50160 Recording of parameters and quality events on SD card (up to 2 GB) Compact size, allowing the unit to be installed in standard double insulation boxes Light and easy to transport Self-detection of current clamps Magnetic attachment to facilitate fastening to an electric panel or metal supports 128 samples per gate (used to calculate data over selected recording period) Metering CIRe+ 3 phase economy portable network analyser type description Voltage : 100-400 VAC, 70-315 VAC Operating temperature: 10ºC - 65ºC Standard: IEC 60664-1, IEC61010-1, IEC62053-21, UL94, VDE 110 Accuracy : Voltage : 0.5% M85050 Analyzer supplied complete with: 52690.00 CP E-Flex 20/54 cm 200/2000/20000 Amp Voltage leads SD memory card and USB/SD card reader (1GB) PC software Canvas carrying bag is a remote control and supervision software for LOVATO Electric devices equipped with communication capabilities via serial ports, Ethernet or modem in a simple and reliable way. The supported protocols are Modbus-RTU, Modbus-ASCII and Modbus-TCP. Its structure and applications are based on MS SQL Express that uses a MS IIS Express web server to control the user interface. The software is capable of: Managing multiple communication channels simultaneously Connecting the devices to the various channels Collecting data from all the devices and storing them in a database Displaying collected data in graphical pages and tables Allowing access to the devices and their data according to the rights of the different users type description SYN1SET supervision and energy management software (parameterising, measurement, 26517.00 monitoring, control, web server, e-mail and FTP file transfer) + enablement of monitoring on 1 LOVATO Electric device. SYN1S005 enable licence of supervision function for 5 additional devices. 10312.00 SYN1S020 enable licence of supervision function for 20 additional devices 30936.00 SYN1S050 enable licence of supervision function for 50 additional devices 61999.00 Above s do not include VAT. E&OE SYN1S100 enable licence of supervision function for 100 additional devices 105192.00 Note: For the number of licences, only devices equipped with communication ports can be considered. E-22

Power analyser DIRIS Q800 is a high-end power quality analyser, able to monitor and record the major power quality parameters. Operating as an event/fault recorder, capable to store a high number of voltage events and disturbances, frequency variations, inrush current, etc. Additional PQ data can be recorded, such as Flicker, Unbalance, Harmonics and Inter harmonics, Mains Signalling. It also provides standard power measurement data for three-phase systems. Extra voltage and current measurement channels give the possibility to monitor Neutral Potential and Earth Leakage current. Main benefits: Embedded Web Server Large colour touch screen with user-friendly instrument web interface Fast simultaneous sampling on 9 channels at 1024 samples / cycle Voltage event recording (sags,swells,interruptions) with storage of 1/2 cycle RMS values and waveforms Frequency variation monitoring and recording with of 1/2 cycle RMS values and waveforms Overcurrent recording on three-phase channels with storage of 1/2 cycle RMS values and waveforms Continuous monitoring of the power quality and Class A certified measurements for voltage characteristics Simultaneous recording of events, Min/Avg/Max LOG and energy counters Analyser software is provided to perform analysis on recorded data according to EN50160 PQ standard Export standard file formats (PQDIF and CSV) to allow quick view and analysis on all stored data Specifications: Power supply: Backup Battery: Recording Memory: 85...285 VAC, 50/60 Hz / 65...250 VDC Li-Ion,2500 mah (>15 min autonomy) 4 GB (16 GB Optional) new DIRIS Q800 Measurement inputs: - Direct voltage measurement input: P-N: max 580 V RMS CAT III, L-L: max 1000 V RMS CAT III - U4 Direct voltage measurement input: Max 580 V RMS CAT III Accuracy: - Three-phase voltage: ±0.1% Un over 10... 150% Un range - U4 voltage: ±0.2% measurement - Currents: ±0.2% measurement (device) - Powers: ±0.2% measurement - Frequency: ±8 mhz - Harmonics: Class 1 (IEC/EN 61000-4-7) - Realtime clock (RTC): <1s in 24h without synchronisation; <5ms with GPS synchronisation - Active energy: Class 0.5S, compliant to IEC/EN 62053-22 - Reactive energy: Class 1, compliant to IEC/EN 62053-23 Communication: - Ethernet ports: 2 x Auto MDIX RJ45 10/100 Base Ethernet - RS485 port (slave): 1 x Optoisolated, 0.5UL, 2400...115200bps - WIFI antenna: 1 x Passive antenna, SMA connector on rear panel - GPS antenna: Active patch antenna, remote powered, SMA connector - Protocols: HTTP, HTTPS, FTP, SFTP, NTP, NMEA, Modbus TCP, Modbus RTU - USB port: 1 x USB 2.0 A type socket, high speed 480 Mbit/s Standard: - Product compliance: IEC/EN 62586-1, IEC/EN 62586-2 - Certification: Class A, IEC/EN 61000-4-30:2015 Ed.3 for voltage type operating temperature DI DO AI memory description DIRIS Q800 multifunction network quality analyser 4826 0100-25... +55 C 4 4 4 4 GB (16 GB optional) network quality analyser 120000.00 E-23 Above s do not include VAT. E&OE

Notes