Compact Speed Monitoring and Overspeed Protection System

Similar documents
T500 DUALTACH. JAQUET T500 DualTach. 2 channel measurement & monitoring instrument 2 CHANNEL TACHOMETER I N C H A R G E O F S P E E D.

SWTD-1000 Speed Switch / Transmitter Operating Manual

CSI 6300 SIS Overview

Valve and Case Expansion Monitor Specifications

SWT-2000 Frequency Measurement and Switching Instrument Operating Manual

Amplifiers, Counters, Timers & Controls

Faults on the system Proximity switch connection technology:

3500/53 Electronic Overspeed Detection System

Protection Cards for AMS 6500 Classic Systems

JAQUET SYSTEMS. Digital Analog Converters Switches Sense Measure Control Protect. We do it all - we do it now. We are ready for your signal.

T600 TACHOMETER MultiTasker - a measurement & monitoring instrument with 2 frequency and 1 analog inputs

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Frequency Measurement and Switching Instruments T401 / T402

FEATURES DESCRIPTION SPECIFICATIONS

RT4F-48V/50A-WAC RECTIFIER

Tachometer Panel, PE3

CPU 224. The compact high-performance CPU With 24 inputs/outputs on board Expandable with up to 7 expansion modules Design

FACTORY AUTOMATION. Manual Speed Monitor KFU8-DW-1.D

DISOMAT T Weigh Transmitter

Contact protection relay

Voltage Transducer UMT516 / MT516

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

Rotary Measuring Technology

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

CPU Units with 20 I/O points

FEATURES DESCRIPTION FEATURES

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Digital Overspeed Protection System with PROFIBUS -DP interface DOPS, DOPS AS, DOPS TS

CALEC energy master The benchmark in energy measurement

Rotary Measurement Technology Absolute Encoders, Singleturn

Supply voltage. Input current. Encoder supply. Memory

IRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A)

RT12-240V/2.4kW Rectifier Specification

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

Frequency Measurement and Switching Instrument Multitasker T601

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Intrinsically Safe Barriers

General information. Display. Supply voltage. Input current. Encoder supply. Output current

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

SINGLE-CHANNEL PROCESS INDICATOR series 8001

Product Specifications

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

RT4F-120V/20A-WAC RECTIFIER

Earth-fault Relay SPAJ 110 C. Product Guide

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

3500/50E Tachometer Module

Model Number Structure

Product Information on the Manual

General information. Display. Supply voltage. Input current

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

General information. Display. Supply voltage. Input current. Encoder supply. Output current

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

RT4F-110V/25A RECTIFIER

CPU 1214C. Overview. Design. The compact CPU 1214C has:

InReg Volume flow controller Pa

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

RT4B-110V/12A RECTIFIER

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track

Display and Monitoing Units

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

02/11/2015

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

LCI User Manual mantracourt.com

Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details

JAQUET SYSTEMS. Digital Analog Converters Switches Sense Measure Control Protect. We do it all - we do it now. We are ready for your signal.

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000

DRTS 33. The new generation of advanced three phase relay test set

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

signo 727 SSI operating instructions

General information. Display. Supply voltage. Input current. Encoder supply. Output current

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

Rotary Measuring Technology Absolute singleturn encoder shaft version

Despite its ultra-slim design, a CPM2C system can provide up to 192 I/O points!

General information. Display. Supply voltage. Input current. Encoder supply. Output current

DINALOG A 144 x 36 A1400 Light-Strip Indicator

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

MIC-2 Multi-instrument DATA SHEET

INTECONT PLUS for Measuring Systems

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

PHOENIX CONTACT - 01/2007

Multi-Point Gas Detection and Control System

Transcription:

Compact Speed Monitoring and Overspeed Protection System FT 3000 Features Designed for 2 from 3 overspeed protection Configuration via PC Standard unit includes Speed measurement Speed relays Sensor monitoring Direction discriminator Test frequency generator Supply monitoring Isolated control lines Modular system expansion to include Isolated analog outputs with independent ranges Intrinsically safe input card (Ex) 2 from 3 selection Redundant power supply Display in the rack Configuration stored in EEPROM Period measurement principle Input directly in machine units eg speed, % etc. Module for remote diagnostics 008.E.02.98

Overspeed protection Application The Jaquet FT 3000 system has been specially developed for high integrity overspeed protection of gas or steam turbines and other similar primary drives. The FT 3000 has been developed as a true 3 channel system that permits machine protection with 2 from 3 voting control at a favourable price. It provides a cost effective solution to monitoring safety critical installations. Maximum availability and high system integrity is achieved through complete redundancy of all functions, along with continuous self checking and test possibilities at each stage in the channel. The clear and open system architecture, using a bus interface, enables the FT 3000 to be used with a master control system so that it provides independent monitoring and machine protection, whilst being part of an integrated system. The system conforms to American Petroleum Institute (API) regulations together with all appropriate European (EN) standards. FT 3000 Basic version 2

Wide range of applications Operation Each channel in an installation is built up separately using Compact Modules. A Compact Module comprises of a FTFU 3024 motherboard plus optional plug in expansion cards (frequency to current converter FTW 3013, relay module FTV 3090). Thanks to large scale hardware integration the system has a minimal space requirement. The FT 3000 monitors 4 set points per channel. The installation can be configured for 2 from 3 voting of the set points. The alarm signals can also be fed to an external system for 2 from 3 voting control. Since the motherboard can be equipped with intrinsically safe input circuits for connection to numerous speed or eddy current sensors, there are no external restrictions on the number of applications for this system. The system provides independently scalable analog outputs and carries out a variety of mathematical functions, such as maximum values (also stored) and the calculation of average values together with acceleration. The FT 3000 permanently checks its system integrity. A test generator integrated on the motherboard enables live testing of each entire channel. The sensor watchdog permanently monitors the sensor for correct operation. 3

3 1 3 1 +V1 An1 An2 An3 I +V1 I K4 +V1 An1 An2 An3 I +V1 I K4 +V1 An1 An2 An3 I +V1 I K4 RS232 I RS232 I Application examples Example 1: FT 3000 without 2 from 3 logic, supply modules or analog card Sensor DS0 DS0 DS0 A1 A2 A3 A4 FT072 A1/Fout A2/Fout A3/Fout 1 2 3 24VDC 24VDC FTZ3069 FTZ3069 channel1 channel2 channel3 I + 24V - + 24V - E178 Example 1 shows a basic FT 3000 configuration. 3 channels are each independently monitored by a FTFU 3024 motherboard. It is assumed that the customer already has a secure power supply and that the 2 from 3 logic for the alarm signals is executed in a higher level system. There is no speed proportional analog output but sensor monitoring, numerous test possibilities along with a communications interface to higher level systems are naturally included. In contrast, example 2 shows an installation that has 3 analog signals per channel in addition to the user programmable limit values. Extensive mathematical functions are available to define these signals. With the addition of FTV 3090 modules, the set point signals are combined to provide 2 from 3 voting within the system. To achieve redundancy in the power supply, 2 supply modules provide an uninterrupted supply to the operating modules. The communications module provides an interface to the outside world and is used for system programming, monitoring and diagnosis via a PC or higher level system. Example 2: FT 3000 with internal 2 from 3 logic, analog outputs and 2 supply modules Sensor DS0 DS0 DS0 Testchannel1 A1..A3 Testchannel2 A4..A6 Testchannel3 A7..A9 Under/Over Reset A10 FT072 PowerOK PowerOK PowerOK Analog A1/Fout Analog A4/Fout Analog A7/Fout A3/An1 n<nmin A6/An1 n<nmin A9/An1 n<nmin A3/An2 n>0.25no A6/An2 n>0.25no A9/An2 n>0.25no A3/An3 A6/An3 A9/An3 n>1.25no n>1.25no n>1.25no 1 2 3 110VDC 230VAC A16 A19 FTZ3065 FTZ3061 channel1 channel2 channel3 I + 24V - + 24V - E179 4

Programming Programming With the FT 3000, Jaquet has set new standards for the definition of operating and configuration parameters. Dedicated Windows software provides a clear system overview and easy programming of multiple values. Parameter sets can be processed and stored on or off-line and the software allows current system status to be continuously monitored. Configuration software For security reasons, 3 level password access is provided to crucial data. The communications module provides a bidirectional interface for data and parameters. Used together with a modem, this allows remote diagnostics of data, alarms and configuration. Functions and configurations can be printed out for archiving and subsequent system comparisons. These printouts can also form part of the commissioning and hand-over documentation, showing the system parameters defined. Extract from the parameter list. 5

Modul overview FTFU 3024 Monitoring module (motherboard) This card is used for montoring a speed (function frequency relay and/or speed detector), the speed direction as well as the correct functioning of the connected speed sensor. For test purposes the instrument is equipped with an integral frequency generator. The monitoring module is a plug-in unit with a width of 4 rack units. Period measurement principle The frequency relay is microprocessor based and works according to the period measurement principle with subsequent computing of the reciprocal value (calculating principle). The sensor frequency is measured continuously. The number of periods considered for one measurement depends on the minimum measuring time (= Fix Time) and the input frequency corresponding to the limit to be monitored. Limits After entering the machine factor M = f/n with f [Hz] = signal frequency of the sensor at a known machine speed and n [RPM] = machine speed, the limit can be entered directly in RPM. Alternatively, the number of poles of the pole wheel (= number of impulses per revolution) and the nominal speed (= 100%) can be entered. The limits are then entered in % of the nominal value. The switch on point (= upper limit = limit high) and the switch off point (= lower limit = limit low) can be entered separately for each alarm so that almost any hysteresis can be realised. The measuring result is used for: monitoring of 4 limit values controlling 3 independently configurable analog outputs as well as for the processing and display of: measured value maximum value acceleration Further input frequencies from 1 or 2 redundant speed sensors can be measured and processed in the following way: Mean value of 2 or 3 measuring channels Maximum value of 2 or 3 measuring channels Selection of 2 out of 3 with error message (dynamic sensor monitoring) On request three of the four limit values can be monitored with a min. measuring time of 1 ms by three speed detectors (realised in hardware). Parameter input The input of all parameters is via an interface. A PC solution with configuration program is available from JAQUET. The input parameters are entered according to the matrix principle. The parameters are stored independent of the power supply by an EEPROM. Technical Data Frequency inputs Frequency input 1 Floating, dielectric proof 500 V, 50 Hz against electronic und protective earth, i.e. against front panel and module. A selection of plug-in modules are available to cater for the various requirements of input sensitivity and supply of speed sensors. The variants are marked with an additional number in the type designation on the label (see overview of the technical data). For test purposes the input trigger level is adjustable at the front panel, together with the permissible min./max. and effective sensor current. Frequency input 2 and 3 dc-coupled, with negative pole of power supply as reference potential. U low : 0 +3 V resp. open; U high : +10 +33 V I source = 4 ma; frequency measurement with redundant speed sensors. Binary inputs The six binary inputs provide configurable test and monitoring functions, e.g. switching over (shift) of limit values input and selection of two internally generated test frequencies resetting the system alarm and limit outputs To store a new configuration the reset input has to be activated for a short-time after switching on the mains supply and also after any occurance of an error message due to the actuation of the start-up bridging, of the sensor monitor or the microprocessor watchdog, before the collective alarm and the binary outputs again correspond to the actual measured values. Binary inputs 1 to 4: Floating, dielectric proof 500 V, 50 Hz against each other and against electronic and protective earth, i.e. against front panel and module. U low : 0 +5 V bzw. open; U high : +10 +33 V; I source = 4 ma max. Binary inputs 5 and 6: With the negative pole of the rack supply of 24V as reference potential U low : 0 +1 V, I sink = 1 ma max. U high : +3.5 +33 V resp. open 6

Modul overview Limits You can define three lots ( A, B, C ) of each 4 limits with the following parameters: lower switching point (LIMIT low) upper switching point (LIMIT high) Function (LIMIT mode) = normal or inverse Status (LIMIT status) = on or off When exceeding the upper limit at normal and on the corresponding output is activated resp. the assigned relay is energized. When falling below the lower limit the output is inactive resp. the assigned relay is de-energized. At inverse and on the status above described are inverted. At off the corresponding output is always inactive resp. the relay de-energized. The status for limit exceeded/fallen below are signalled by four red/green LED-pairs. The assignment of the colour to the relevant status of each limit is done in a user configuration. Relay outputs Each of the three relays in the module can be assigned to any limit or monitoring function. At collective alarm (due to the system monitoring and/or the sensor monitoring) the relays are de-energized. The maximum reaction time is equal to double the selected minimum measuring time (Fix Time) +1 period of the input frequency +2.5 ms computing time. For the Fix Time the following values can be selected: 5/10/20/50/100/200/500 ms /1/2/5 s With a Fix Time of 5ms and a switching frequency >2000 Hz, the reaction time of the relay outputs is max. 14.5 ms and typ..0 ms for de-energizing respectively max. 21.0 ms and typ. 18.5 ms for energizing. System monitoring A failure is signalled in case of the following events: Microprocessor self-test error Run-out of the Watchdog-Timer Supply voltage failure Interruption of power supply fuse Mains failure A green LED is on as long as there are no failures. Two frequency outputs Frequency output 1 Impulse output, with negative pole at reference potential Push-pull circuit: Impulse amplitude +10 Vp output resistance 100 Ω Output current: 50 ma continuous 100 ma temporary (10% duty cycle) Frequency output 2 Floating impulse output Dielectric proof 500 V, 50 Hz against electronic and protective earth, i.e. against front panel and module. Push-pull circuit: Impulse amplitude 15 Vpp Output resistance 100 Ω Output current: 50mA continuous 100 ma temporary (10% duty cycle) 7

Modul overview FTW 3013 Frequency-current converter (supplementary module) This instrument is used together with the monitoring module FTFU 3024 for measurement of a frequency resp. a frequency proportional speed. The converter is mounted as supplementary module on the module FTFU 3024 and represents thus a plug-in module with a total width of 8 rack units. Analog outputs The three D/A-Converters in the FTW 3013 permit the display of three frequency ranges or of mean values, maximum values or 2 of 3 majority values on three current output ranges, independent of each other. Measurement The number of periods considered for one measurement depends on the selected measuring time (= Fix Time) and the input frequency. The initial and end values of each measuring range can be entered as speed value in RPM after input of the machine factor M=f/n with f [Hz] = signal frequency of the sensor at a known machine speed and n [RPM] = machine speed. Alternatively, the number of poles of the pole wheel (= number of impulses per revolution) and the nominal speed (= 100%) can be entered. The input of the initial and end value of the measuring range is then directly entered in percent of the nominal value. For each measuring range the inital and end value as well as the corresponding current output can be entered separately. The three current outputs show 0 ma in case of a collective alarm (due to the system monitoring and/or the sensor monitoring). FTV 3090 Relay module (supplementary module) This instrument is used for monitoring a frequency resp. a frequency proportional speed together with the monitoring module FTFU 3024. With four separate relays it permits the simultaneous switching of several galvanically isolated loads. The relay module FTV 3090 is fixed as a supplementary module on the monitoring module and represents thus a plug-in module with a total width of 8 rack units. It can alternatively be fixed with the monitoring module and the supplementary module FTW 3013 and represents thus a plug-in module with a total width of rack units. Functions Each of the 4 relays of the module may perform the same functions as the 3 relays of the monitoring module FTFU 3024. Parameter input All additional parameters are entered with a interface accessible at the rear of the monitoring module and according to the matrix principle. The parameters are stored independent of the power supply by an EEPROM. Parameter input The input of all parameters is made at the FTFU 3024 with the interface accessible at the rear and according to the matrix principle. The parameters are stored independent of the power supply by an EEPROM. Technical Data FTW 3013 Setting time (1% difference to the final value.) The maximum setting time is equal to double the selected minimum measuring time (Fix Time) + 1 period of the input frequency + 2.5 ms computing time + 5.0 ms transient time. For the Fix Time the following values can be selected: 5/10/20/50/100/200/500 ms /1/2/5 s With a Fix Time of 5ms the setting time of the analog outputs for circuit frequencies > 2000 Hz is max. 18 ms and typical 16.5 ms. The current at the moment of switching on is equal to the initial value of the range. 8

FTK 3072 Communication module The communication module FTK 3072 is used for communications between the rackbus, i.e. interface accessible at the rear of the monitoring module FTFU 3024 (max. 31 modules) and a host computer, PC or a memory programmable controller. All parameters for the modules are then entered through the master system. FTZ 2061/3061 power supply unit Input voltage 115/230 V AC, -20%, +15% FTZ 2062/3062 power supply unit FTZ 2065/3065 power supply unit Input voltage 88 372 V DC, 85 264 V AC Common data for power supplies: Input voltage: galvanic isolation, dielectric proof 2000 V, 50 Hz 1 min., against protective earth, i.e. front panel, module and output. Output voltage nominal: 24 V DC, (5% min. 18 V DC/2 A/36 W max. 33 V DC/1.3 A/43 W. With an output voltage of 18 33 V DC control LEDs are illuminated. FTZ 2069 Mains filter Without front panel, width rack units. Necessary, if the plug-in modules are directly supplied with 24 V DC. Input voltage 24/48 V AC, -20%, +15% FTZ 2064/3064 power supply unit Input voltage 14 70 V DC Input/Output of the Modules Chart 1: Input/output of the modules Sensor input Test frequency Binary input Relay drive Current output Binary output Relay/Contact Frequency output FTFU 3024 Monitoring module 1+2 2 4+2 4 3 2 FTW 3013 Frequency-current converter 3 FTV 3090 Relay module 4 FTK 3072 Communication module FTU 2045/3045 Mains control* 2 2 FTU 2020/3020 Key* 4 *) Modules from FT 2000 which are compatible with FT 3000 9

Technical data of modules Chart 2: Technical data of modules FTU 3024 FTW 3013 FTV 3090 FTK 3072 FTZ 306X Rack mounting Plug-in 19 rack mounting modules, Europa card size Height: 3 units = 132.5 mm, width: 4 units = 20.32 mm Height: 3 units = 132.5 mm, width: units = 60.96 mm Height: 3 units = 132.5 mm, width: 20 units = 101.60 mm Precision 0.1% according to DIN/VDE 0410, referring to the corresponding limit value Resolution of 4 decades resp. 0.1% the limit input Temperature drift max. 50 ppm/ K referring to the corresponding limit value Max. 150 ppm/ K Power supply 18 33 V DC, typ. 1.8 W/max. 3 W Voltage is stabilized on +5V with a regulator and if necessary galvanically separated through oscillation transformers. Protection Mains voltage failure bridged up to 50 ms against mains without mulfunction volt. failure Ambient 0 +60 C, +70 C during max. 2 hours temperature over 60 C without functioning liquid crystal display ( 4 lines of 16 figures each). Storage temperature -20 +85 C Frequency range 0.050 Hz 29.99 khz lowest: 0 0.9990 Hz highest: 0 29.99 khz The range may be passed as long and as high as you like (max. 50 khz), without mulfunction or damage of the instrument. Frequency potential free, dielectric proof 500V, 50Hz against input 1 electronics and protective earth, i.e. against front panel and rack frame.respond sensitivity and sensor supply depending on the used module. FTFU 3024-01: 50 mveff/ V Sensor supply, max. 25 ma/ex i FTFU 3024-02: 50 mveff/ V Sensor supply, max. 50 ma/not Ex i FTFU 3024-03: programmable acc. to Standard API 670 Frequency DC-coupled, negative pole of the power supply input as reference potential 2 and 3 U low : 0 +1V, I sink = 1 ma max U high : +3.5 V +33 V resp. open Binary input DC-coupled, potential free, dielectric proof 500 V, 50 Hz 4 1 4 against electronics and protective earth, i.e. against front panel and rack frame. active low: I sink = 1 ma high: U = +3.5 V +33 V resp. open Binary input DC-coupled, negative pole of the power supply 5 and 6 as reference potential U low : 0 +1 V, I sink = 1 ma max. U high : +3.5 V +33 V resp. open 10

Technical data of modules cont. p. 10 FTU 3024 FTW 3013 FTV 3090 FTK 3072 FTZ 306X Frequency Impulse output with negative pole of power supply output 1 as reference potential Push-pull circuit: Amplitude +10 Vs; impedance 100 Ω Output current: ±50 ma continuously admissible; ±100 ma temporary (10% duty cycle) Frequency DC-coupled, potential free, dielectric proof 500 V,50 Hz output 2 against electronics and protective earth, i.e. against front panel and rack frame. Other data according to frequency output 1 Relay outputs potential free change-over contacts, max. 250 V, 1 A, 50 W. 3 4 At inductive load external spark suppression is necessary. A green LED signals relay energized. Functions: limit value 1,2,3 or 4 Sensor monitoring Sensor AND Module monitoring logically combined Module monitoring Supply monitoring Supply AND Module monitoring logically combined Direction of rotation on/off Current output 0 20 ma resp. 4 20 ma; selectable for rising or falling transfer function. Maximum load 500 Ω corresponding to a maximum of 10 V; maximum open-circuit voltage 20 V; potential free, dielectric proof 500 V, 50 Hz against each other and against electronics and protective earth and against front panel and rack frame. Resolution Bit corresponding to 1:4096 Linearity error: max. 0.1% Electromagnetic power supply circuit: input and output circuits: compatibility IEC 255-4 common mode: (EMC) 2,5 kvs 2,8 kvs IEC 255-4 series mode: 1,0 kvs IEC 801-4 common mode: 2,0 kvs 1,0 kvs Interface Local Bus (Standard for all Modules FT 3000) Rack-Bus (interface, with negative pole of dc power supply 18 33V as reference potential, dielectric proof 500V, 50Hz against protective earth, against front panel and rack frame. Men/machine via key buttons 11