DelfiScan C70. Programming Manual

Similar documents
2D BARCODE SCANNER CA-SC-20200B

Configure Your FuzzyScan

BARCODE SCANNER. FUZZYSCAN FAMILY Quick Start Guide

BARCODE IMAGER. Programming Manual International Edition, Rev. B7

BARCODE IMAGER. Programming Manual International Edition, Rev. C6

Getting Familiar with Your FuzzyScan

BARCODE SCANNER. Configuration Guide - 1 -

FIXED MOUNT SCANNER. Programming Manual International Edition, Rev. B1

NC-1200 BARCODE SCANNER. Configuration Guide - 1 -

BARCODE IMAGER. Programming Manual International Edition, Rev. D7

Table of Contents Sleep Settings How to Configure the Scanner. 7 Chapter 2 System Setup

PureScan - ML1. Configuration Guide. Wireless Linear Imager Wireless Laser scanner - 1 -

International Edition, Rev. D13

WIRELESS IMAGER. Reference Manual. International Edition, Rev. A9

Start Configuration. Chap.1 System Information. Set All default

Hand Held Linear Imager

International Edition, Rev. D15

COPYRIGHT 2009,SCSC. Manual P/No: SCCM - 80S-01A Released Date: Oct 31, 2009

User s Guide. Linear Imager

Flow chart of bar code reader setting

MK D Imager Barcode Scanner Configuration Guide

User s Manual. Xi3000 Scanner. Table of Contents

GS100. CCD Barcode Scanner. User Manual

Setup Procedures 2 Batch Setup 3. Bar Code Setup Menu 5. 1 Device Selection and Default. 2 Beep and Delay Keyboard Wedge..

Xi2000-BT Series Configuration Guide

USER'S GUIDE HANDHELD SCANNER IMS-3190

International Edition, Rev. C8

marson MT8200S 2D Handheld Scanner User Manual V / 6 / 25 - I -

2D Barcode Reader User Guide V 1.2.1

WIRELESS IMAGER Reference Manual

FD-011WU. 2D Barcode Reader User Guide V1.6CC

Table of Contents. Introduction Installation Pin Assignments Method of Programming Setup Commands... 9

Installation- Keyboard Wedge

Configuration Manual PULSAR C CCD SCANNER. Table of Contents

CCD-BARCODE SCANNER. Programming Manual. To program the device, scan the following codes: FIRST: start configuration %$ + / 0

ZB-8150/ZB-8110/ZB-8210 CCD BARCODE SCANNER. User s Manual. ZBA Inc 249 Homestead Rd Unit 12 Hillsborough NJ 08844

BD-6500BT Bluetooth 2D Barcode Scanner Configuration Guide

Introduction. Installation- Keyboard Wedge

Product Engineering Specification Scan Utility

NCR Realscan 7837 High-Performance Scanners. User s Guide Issue A

Laser Barcode Scanner ARP Nr User s Manual

Preliminary draft_1. Prefix Scanned Data Suffix. Intercharacter Delay. Intercharacter Delay

Getting Started Setup Procedures

MD5 Series Barcode Scanner

MD22xx Barcode Scanner

NOTICE: respective owner. Note: Specification is subject to changes without. notice.

SPEECHMIKE TM PHI BARCODE READER PROGRAMMING MANUAL PRO READER

BAR CODE. SYMBOLOGY PROGRAMMING for POCKET SCANNERS

DLL2020. Software Configuration Manual

Area Imager Bar Code Scanner 2 D C O N F I G U R A T I O N G U I D E

ZBX P/N : MUL LASER LIGHT CAUTION DO NOT STARE INTO BEAM

Specification or version may be subject to change without notice. The actual specification and version are based on the product delivered.

If you want to do other configurations please refer to below programming barcodes.

Manual de Programación

广州虹源电子有限公司. Guangzhou Hong yuan Electronic co.,ltd. Configuration Manual

2D barcode scanner User Manual

510-2d Complete Configuration Guide Worth Data Inc. 05/2010

1.1 Notice Introduction Codes Read Installation Pin Assignment Specification... 8

If you want to have other configurations please refer to below programming barcodes. Check Scanner Version

CCD - 75 USB. Programming Manual. GOMARO s.a. - Z.I. La Rosaire 5 - CH Aclens

Introduction FCC Statement

Manuel de programmation du lecteur LDT75C ver 2.1

Nuscan 3200 Optical Laser Barcode Scanner

Manual POSline SC2120/SC2130/SC2140 1D & 2D Barcode Reader User's

Wireless 2D Pocket barcode scanner

IPDA014-2D. Embedded 2D Barcode Scan Engine. User Guide

MD65xx Image Barcode Scanner

QuickScan QS2500 Handheld Bar Code Scanner

XB-8200 Hand Free Area Image Scanner Configuration Guide

MD22xx Barcode Scanner

User s Manual. Addendum to. Ranger Wedge Interface. Part No. 25-WEDGE-06A Ver. April 1999

Wired Laser Barcode Scanner User Manual V:1509

WLR 8900/8905 Programming Guide

ValueScan II TM Barcode Scanner. User s Manual rev.a

GS500 2D Area-Imaging Scanner. User Manual

Setting code User Manual

MP80xx Image Platform

AsReader Gun(ASR-R250G) AsReader Combo(ASR-023xD/ASR-0240D) Barcode Setting Manual

Omni-Directional Barcode Scanner Model No. OM7120

User s Manual WARNING CIPHER 1000 CCD SERIES

Programming with barcodes

Advanced Handheld High-Speed Laser Scanner

International Edition, Rev C9

C O N F I G U R A T I O N G U I D E

Table of contents. Change scanner settings Factory default settings Default message format Programming flow chart

Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon Telephone: (541) Fax: (541)

Wireless 2D Pocket barcode scanner

IDM1xx Bluetooth Hand-held Scanners

Delivery content * Pocket Barcode scanner x 1 * Mini USB cable x 1 (for charging only) * Quick instructions x 1 * Strap x 1

Wearable 2D Pocket barcode scanner

If you want to do other configurations please refer to below programming barcodes.

MP168 Screen Barcode Image Platform

2D Wired Barcode Scanner Overview

User s Manual. MS140-3 or MS140I-3 Keyboard Wedge Slot Reader. PC Keyboard Wedge Setup Label

Disclaimer All rights reserved.

Z3S. Quick Setup Guide V Connection Mode. Working via Bluetooth. Barcode Programming. Working via USB cable

MP720 Presentation Imager

2D Wired Barcode Scanner Overview. Keyboard Language In order to let scanner upload the codes in a correct way, you have to set the keyboard language.

C O N F I G U R A T I O N G U I D E

Installation- Keyboard Wedge

Transcription:

DelfiScan C7 Programming Manual

Table of Contents Getting Started Getting Familiar with your DelfiScan Connecting/Disconnecting Cable Connecting Host Interface 4 Configure Your DelfiScan Bar Code Programming Manual 5 Programming Procedures 6 Host Interface Selection Symbology Reading Control Keyboard Interface Control 6 Serial Interface Control Wand Emulation Control Operation Control 4 Condensed DataWizard Appendix Keyboard Function Code Table 45 ASCII Input Shortcut 46 Host Interface Quick Set / Operation Mode Quick Set 47 Option Codes 48 System Commands 49 Regulatory FCC part 5B EN55, EN554, EN6--, EN6-- CNS48 Industry Canada ICES- LED Eye Safety IEC685-

Getting Started Getting Familiar with your DelfiScan Thank you for choosing DelfiScan Imager. All DelfiScan Imagers deliver world-class performance for a broad range of market applications to unleash your productivity. This document provides installation and programming instructions for DelfiScan Imagers. C7 Series. Power Indicator. Status Indicator. Trigger 4. Scan Window 5. Beeper 6. Cable Release Hole Connecting/Disconnecting Cable DelfiScan imagers provide PS/(DOS/V) Keyboard Wedge, RS- Serial, USB interfaces capability. To disconnect the cable, please straighten one end of a paper clip, then insert it into the cable release hole and press in. After that, you can release the cable and pull the cable out easily. C7 Series

Connecting Host Interface DelfiScan imagers have capability to connect different host devices by PS/(DOS/V) Keyboard Wedge, RS- Serial and USB interfaces. Please choose one of the interface cables to connect your host device by referring to the illustrations below. PS/(DOS/V) Keyboard Wedge RS Serial USB 4

Bar Code Programming Menu The DelfiScan bar code commands are specially designed Proprietary bar code labels which allow you to set the DelfiScan internal programming parameters. There are System Command, Family Code and Option Code for programming purpose. Each programmable family and bar code command label is listed on the same page with major system commands. The detailed explanations and special programming flowchart are printed on facing or following pages. You can read the explanation and set the DelfiScan concurrently. A supplemental bar code command menu incorporates the bar code command labels of System Command and Option Code. As you set the DelfiScan, open the bar code command menu to find the option code page. You may scan the desired family code and option code to set DelfiScan. If you want to change the programming family for multiple settings, you need only turn over the programming page to find next desired programming family. System Command The System Command is the highest level bar code command which directs DelfiScan to perform immediate operations, such as entering programming mode (), exiting programming mode (EXIT), listing system information (SYSLIST), recovering to factory preset configurations (), and so on. Please note that all system commands will take a few seconds to complete the operations. User must wait for the completion beeps before scanning another bar code. Family Code The Family Code is scanned to select the user desired programming family. DelfiScan has already provided more than one hundred programming families to meet any specific requirements. Option Code The Option Codes is a set of bar code commands represented by 9, A F and finishing selection (). For most setting, you must select at least one option code following the family code selection to set the desired parameter for the selected programming family. 5

Programming Procedures As you scan the bar code command to select the desired parameters, information about the final selected parameters represented by the bar code commands are stored in the DelfiScan s internal Flash Memory ASIC or non-volatile memory. If you turn off the unit, the Flash Memory ASIC or non-volatile memory retains all programming options. You need not re-program the DelfiScan if you want to keep the existing configurations in the next power on. The programming procedures of DelfiScan are designed as simple as possible for ease of setting. Most programming families take the Single Scan Selection programming procedure. But several programming families have more complex and flexible programmable options, and you must take Multiple Scans Selection, Cycling Scan Selection or Dual Level Selection to complete their programming procedures. Each kind of programming procedure is listed in the following pages for your reference. Please give careful attention to become familiar with each programming procedure. If the programming family must take multiple scans selection, cycling scan selection, or dual level selection procedures, the family of the programming menu will be marked with the matched representing symbol of Programming Category (P.C.) in bold font listed in the following table. You can easily find the bold mark in the programming menu, and refer to their flowcharts for details. Before setting the DelfiScan, please also refer to the Beeping Indications listed in Appendix to understand the details of programming beeping indications. It will be very helpful for you to know the existing status while you are programming the DelfiScan. Conventions of Programming Menu Conventions P.C. Factory Default Value Descriptions Programming Category : Single scan selection : Multiple scans selection CS : Cycling scan selection DS : Dual level scan selection ( ) Necessary Option Code [ ] Selectable Option Code 6

Program & End Scan DelfiScan will enter programming mode, and inhibit all non-programming functions. Scan END DelfiScan will exit programming mode, and store all parameters in Flash Memory ASIC or non-volatile memory, then issue the completion beeping. Please note that the DelfiScan will take -4 seconds to store parameters in internal Flash Memory ASIC or non-volatile memory after you scan the END. Please don t turn off the power before the completion beeping. It may destroy all configured parameters. System List, Group & Master Default Scan SYSLIST DelfiScan will list the product information and revision number to host via selected host interface, then issue the completion beeping. Scan DelfiScan will recover all programmable parameters into factory preset configurations, then issue the completion beeping. 7

Single scan selection Scan Enter programming mode. Scan One of Family Codes Select one of desired programming families. Scan One of Option Codes Select one option code of desired parameter. Yes Repeat Selection Want to select another programming family? Scan END No Exit programming mode. 8

Multiple scans selection Scan Enter programming mode. Scan One of Family Codes Select one of desired programming families. Scan One or Several Option Codes. Select one or several option codes to select desired parameters. Yes Repeat Selection No Scan END. If it s necessary, scan to terminate option code selection. Want to select another programming family? Exit programming mode. 9

Cycling scan selection Scan Enter programming mode. Scan One of Family Codes Select one of desired programming families. Scan One of Option Codes Cycling select one or several option codes of desired parameters as Single or Multiple scans selection. Yes Scan Repeat Selection No Scan END Finish cycling selection. (If necessary) Want to select another programming family? Exit programming mode.

Dual level selection Scan Enter programming mode. Scan One of Family Codes Select one of desired programming families. Yes (st) Scan Several Option Codes (nd) Scan One or Several Option Codes Repeat Selection No Scan END Select several option codes of desired parameters.. Select one or several option codes of desired parameters.. If it s necessary, scan to terminate option code selection. Want to select another programming family? Exit programming mode.

Host Interface Selection Family Code Selection P.C Parameter Selection Option Code Host Interface Selection Standard/TTL RS- peer-to-peer serial interface Wand emulation interface PC/AT, PS/ keyboard replacement interface (without external keyboard) General Notebook PC keyboard wedge interface (with external keybaord) USB keyboard interface (for Microsoft Windows 98,, XP, Vista and Apple imac) IBM PS/55 5576- (code set 8) keyboard wedge interface IBM PS/55 5576- (code set 8) keyboard wedge interface IBM PS/55 5576- (code set 8) keyboard wedge interface IBM PS/55 5576-A (code set ) keyboard wedge interface IBM PS/55 5576- (code set 8A) keyboard wedge interface IBM PS/55 5576- (code set 8A) keyboard wedge interface IBM PS/55 5576- (code set 8A) keyboard wedge interface IBM PS/V PC, 5576- (code set 8) keyboard wedge IBM PS/V PC, 5576- (code set 8) keyboard wedge IBM PS/V PC, 5576- (code set 8) keyboard wedge IBM PS/V PC, 5576-A (code set ) keyboard wedge DOS/V keyboard direct link 6 8 8 7 7 7 7 74 75 76 77 78 79 8 85

Symbology Reading Control User Defined Symbol ID Family Code Selection P.C Parameter Selection Option Code nd Option Code Symbol ID : character DS Code 8 (default=b) UCC/EAN-8 (default=c) UPC-A (default=a) EAN/JAN/CAN- (default=f) Codabar/NW-7 (default=d) Code 9/Code (default=g) Code 9 (default=h) Standard/Industrial of 5 (default=i) Interleaved of 5 (default=j) Matrix of 5 (default=k) China Postal Code (default=l) German Postal Code (default=m) ATA (default=o) Code (default=p) I/Plessey (default=r) UK/Plessey (default=s) Telepen (default=t) Symbol ID : character DS UPC-E (default=e) EAN-8 (default=ff) UPC/EAN with 5 Supplement (default=u) UPC/EAN with Supplement (default=v) 4 5 6 7 8 9 4 5 6 7 ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) ( character) [- characters],[] [- characters],[] [- characters],[] [- characters],[]

Symbology Reading Control Symbology ID Trans., Readable Bar Code Setting Family Code Selection P.C Parameter Selection Option Code Symbology ID Transmission Disable symbology ID transmission Enable prefix symbology ID transmission Enable suffix symbology ID transmission Enable both prefix and suffix symbology ID transmission Readable Symbology Setting Automatic discrimination CS Code 8, UCC/EAN-8 CS UPC-A CS UPC-E CS EAN/CAN/JAN- 4 CS EAN/CAN/JAN-8 5 CS Codabar/NW-7 6 CS Code 9/Code, HIBC 7 Remember to scan to terminate CS Code 5 Family, IATA 8 this selection. But if you select the CS Code 9 9 Automatic discrimination, CS Code C7 will terminate this selection CS I/Plessey automatically. CS UK/Plessey CS Telepen CS GS DataBar (R-4) 4 If your application is reading known, limited bar code symbologies, you may increase the reading speed and decrease the reading error possibility by selecting those known symbologies only. Furthermore, to add the Symbology ID into the transmitted data is also helpful for applications to identify the specific symbology ID. 4

Symbology Reading Control Code 9/Code Setting Family Code Selection P.C Parameter Selection Option Code Select Standard Code 9 as primary format Code 9 Family Setting Select Full ASCII Code 9 as primary format Select Code (Italian Pharmaceutical) as primary format Disable start/stop symbol transmission Enable start/stop symbol transmission 4 Disable Code leading A transmission 5 Enable Code leading A transmission 6 Disable MOD 4 check digit verification 7 Enable MOD 4 check digit verification 8 Disable check digit transmission 9 Enable check digit transmission A Code 9 Append Off B Code 9 Append On C Code 9 Min. Length Default (4) -Maximum Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. Code 9 Max. Length Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. 5

Symbology Reading Control Codabar/NW-7 Setting Family Code Selection P.C Parameter Selection Option Code Codabar Setting Select Codabar standard format Select Codabar ABC format Select Codabar CLSI format Select Codabar CX format Disable start/stop symbol transmission Enable ABCD/ABCD start/stop symbol transmission Enable abcd/abcd start/stop symbol transmission Enable ABCD/TN*E start/stop symbol transmission Enable abcd/tn*e start/stop symbol transmission Disable check digit verification Enable check digit verification Disable check digit transmission Enable check digit transmission 4 5 6 7 8 9 A B C Codabar min. Length Default (4) -Maximum Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. Codabar Max. Length Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. 6

Symbology Reading Control UPC-A & UPC-E Setting Family Code Selection P.C Parameter Selection Option Code UPC Family Setting Disable UPC-E expansion Enable UPC-E expansion Disable UPC standardization Enable UPC standardization Disable UPC numeric system 4 Enable UPC numeric system Disable UPC-A check digit transmission 5 6 Enable UPC-A check digit transmission Disable UPC-E check digit transmission 7 8 Enable UPC-E check digit transmission 9 Disable UPC leading portion Enable UPC leading portion A B Select UPC without supplement digits UPC Supplement Setting Select UPC with only supplement digits Select UPC with only 5 supplement digits Select UPC with /5 supplement digits Disable force supplement digits output 4 Enable force supplement digits output 5 UPC Family Addenda Separator Off 6 UPC Family Addenda Separator On 7 UPC-E & EAN-8 Expansion: UPC-A/E Standardization: UPC Lead Numeric System: Expand the 7-digit UPC-E, 8-digit ENA-8 to -digit UPC-A and -digit EAN-. Expand the 7-digit UPC-E and -digit UPC-A to 8-digit UPC-8 to -digit EAN- with zero insertion. Enable to read UPC leading with the numeric system, you must enable this option. 7

Symbology Reading Control UPC-A & UPC-E Setting WPC Selection (UPC/EAN/JAN/CAN) Basic Length Disable Check Digit Disable Numeric System With -digit Addendum With 5-digit Addendum Enable Standardization Enable Expansion UPC-A - - + + 5 + UPC-E 7 - - + + 5 + + 5 EAN/JAN/CAN- - NC + + 5 NC EAN/JAN/CAN-8 8 - NC + + 5 NC + 5 8

Symbology Reading Control EAN/JAN/CAN & IATA Setting Family Code Selection P.C Parameter Selection Option Code EAN/CAN/JAN Setting Disable EAN-8 expansion Enable EAN-8 expansion Disable EAN- check digit transmission Enable EAN- check digit transmission Disable EAN-8 check digit transmission 4 Enable EAN-8 check digit transmission 5 Disable ISBN/IN Conversion reading check 6 Enable ISBN/IN Conversion reading check 7 EAN/CAN/JAN Supplement Setting Select EAN without supplement digits Select EAN with only supplement digits Select EAN with only 5 supplement digits Select EAN with /5 supplement digits Disable force supplement digits output Enable force supplement digits output EAN/JAN Addenda Separator Off 4 5 6 IATA Setting EAN/JAN Addenda Separator On Select 5-digit fixed length IATA checking 7 Select variable length IATA Disable check digit verification Enable check digit automatic verification Enable S/N checking digit verification only 4 Enable CPN checking digit verification only 5 Enable CPN, Airline and S/N check digit verification 6 Disable start/stop symbol transmission 7 Enable start/stop symbol transmission 8 Disable check digit transmission 9 Enable check digit transmission A 9

Symbology Reading Control Code 5 Family & German Post Code Setting Family Code Selection P.C Parameter Selection Option Code Code 5 Setting Select any Code 5 Select Standard/Industrial of 5 only Select Matrix of 5 only Select Interleaved of 5 only Select Interleaved of 5 S Code only 4 Select IATA only 5 Select China Postal Code only 6 Disable check digit verification 7 Enable check digit verification 8 Disable check digit transmission 9 Enable check digit transmission A Code 5 Min. Length Default (6) -Maximum Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. Code 5 Max. Length Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. German Postal Setting Disable Enable The DelfiScan can decode almost all Code 5 symbologies automatically. But we recommend that you select only one kind of Code 5 for reading, or set limited maximum and minimum reading length for reading, because the encoding algorithm of Code 5 isn t very good. To decode all Code 5 automatically or to read variable length Code 5 will increase the error reading rate.

Symbology Reading Control Code & Code 9 Setting Family Code Selection P.C Parameter Selection Option Code Code Setting Select -check digit verification Select -check digit verification Disable check digit transmission Enable -check digit transmission Enable -check digit transmission 4 Code Min.Length Code Max. Length Code 9 Setting Default (4) -Maximum Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. Disable check digit transmission Enable check digit transmission Code 9 Min. Lenght Default () -Maximum Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. Code 9 Max. Lenght Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.

Symbology Reading Control I/Plessey, Code 8 & UCC/EAN 8 Setting Family Code Selection P.C Parameter Selection Option Code I/Plessey Setting Select MOD check digit Select MOD - check digit Select MOD - check digit Disable check digit transmission Enable -check digit transmission Enable -check digit transmission 4 5 I/Plessey Min. Length I/Plessey Max. Length Code 8/EAN-8 Setting Default (4) -Maximum Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. Disable check digit transmission Enable check digit transmission ISBT Concatenation On ISBT Concatenation Off Code 8/EAN-8 Min. Length Default (4) -Maximum Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. Code 8/EAN-8 Max. Length Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.

Symbology Reading Control UK/Plessey & Telepen Setting Family Code Selection P.C Parameter Selection Option Code UK/Plessey Setting Select UK/Plessey Standard Format Select UK/Plessey CLSI Format Disable Convert X to A-F Enable Convert X to A-F Disable check digit transmission Enable check digit transmission 4 5 UK/Plessey Min. Length UK/Plessey Max. Length Telepen Setting Default (4) -Maximum Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. Select Telepen Numeric mode Select Telepen Full ASCII mode Disable check digit transmission Enable check digit transmission Telepen Min. Length Default (4) -Maximum Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. Telepen Max. Length Default (98) 98-Minimum Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically.

Symbology Reading Control GS DataBar Setting Family Code Selection P.C Parameter Selection Option Code GS DataBar (R-4) Setting Disable GS DataBar (R-4) decoder Enable GS DataBar (R-4) decoder Disable limited GS DataBar (R-4) decoder Enable limited GS DataBar (R-4) decoder Disable expanded GS DataBar (R-4) decoder Enable expanded GS DataBar (R-4) decoder 4 5 4

Keyboard Interface Control Keyboard Layout (Language) Setting Family Code Selection P.C Parameter Selection Option Code Keyboard Laybout USA (QWERTY) France (AZERTY) Germany (QWERTZ) United Kingdom - UK (QWERTY) Canadian French (QWERTY) Spain (QWERTY) Sweden/Finland (QWERTY) Portugal (QWERTY) Norway (QWERTY) Latin America (QWERTY) Italy (QWERTY) Netherlands (QWERTY) Denmark (QWERTY) Belgium (AZERTY) Switzerland-Germany (QWERTY) Iceland (QWERTY) Japan (DOS/V) Universal * (see note) 4 5 6 7 8 9 4 5 6 99 The Universal Selection is only for PC/AT, PS/VP, PS/ and compatible ones in DOS or Windows environment which can perform unique output without Caps Lock on/off (Output Style) concern. All transmitted data will follow the original full ASCII form. You also need not worry about the upper/lower case control. Please refer to the ASCII/HEX Table listed in the Appendix to determine HEX codes for characters, symbols, and functions to be used as premble or postamble. To set preamble or postamble as function key output, you must enable the Function Key Emulation feature as listed in page -5 first. Keyboard Interface Message String : Preamble Data Length Prefix Symbol ID Scanned Data Suffix Symbol ID Postamble Record Suffix -5 characters - digits or characters Variable length or characters -5 characters character 5

Keyboard Interface Control Record Suffix, Preamble, Postamble & Caps Lock Family Code Selection P.C Parameter Selection Option Code Record Suffix None RETURN TAB SPACE ENTER (Numeric Key Pad) User defined character ( character) 4 5, (-7F) Preamble None -5 characters [-7f], [] Maximum 5-character input; scan to terminate this selection. Postamble None -5 characters [-7f], [] Maximum 5-character input; scan to terminate this selection. Caps Lock Control Caps Lock Off State Caps Lock On State Auto Detect (PC/AT, PS/, Keyboard Replacement and DOS/V Machines only) Caps Lock Release Control Caps Lock On, Caps Off Caps Lock On, Shift Off The function of Caps Lock Control and Key Pad Emulation are only available for IBM PC/AT, PS/VP, PS/ series personal computers and compatible machines. While selecting the other host interfaces, these selections don t perform the above functions for you. Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select Caps Lock Off state, then C7 will perform normal data transmission. If the Caps Lock state is on, select Caps Lock On state. Select Auto Detect, C7 will perform special transmission handshaking without changing the status of Caps Lock switch. 6

Keyboard Interface Control Delay Setting Family Code Selection P.C Parameter Selection Option Code Character Frame Control None -99 msec. Scan digits from the option code chart in Appendix, then C7 will terminate this selection automatically. Intermessage Delay None -99 (x5) msec. Scan digits from the option code chart in Appendix, then C7 will terminate this selection automatically. Intercharacter Delay None -99 (x5) msec. Scan digits from the option code chart in Appendix, then C7 will terminate this selection automatically. Interfunction Delay None -99 (x5) msec. Scan digits from the option code chart in Appendix, then C7 will terminate this selection automatically. Character Frame Control is used to adjust timing gap between bytes within one character data output by C7. Intermessage Delay is a time delay between messages output by C7. Increasing this delay will help host applications process the incoming data on time. Intercharacter Delay is a time delay between data characters output by C7. These two parameters are used to synchronize data communication when : ) the data transmission speed is too fast, characters may be skipped; ) multitasking operation system or host computers in a network may slow down the keyboard handling; ) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safty margin when adjusting these two parameters. Interfunction Delay is a time delay between the transmission of each segment of the message string. 7

Keyboard Interface Control Emulation Setting & Upper/Lower Case Setting Family Code Selection P.C Parameter Selection Option Code Function Key Emulation Enable ASCII - code as keyboard function code output Ctrl-Output Refer to Appendix Keyboard Function Code Table for details. Key Pad Emulation Disable key pad emulation Enable numeric output as key pad (Num Lock On) output Upper/Lower Case Normal case (neglect the upper/lower case control) Inverse case (change all characters output to inverse case) Upper case (force all characters output as upper case) Lower case (force all characters output as lower case) 8

Serial Interface Control Record Suffix, Preamble,Postamble Setting Family Code Selection P.C Parameter Selection Option Code STX/ETX Control Disable STX/ETX transmission Enable STX/ETX transmission STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface. Record Suffix None CR (DH) LF (AH) CRLF (DAH) TAB (9H) SPACE (H) User defined character ( character) 4 5 6, (-7F) Preamble None -5 characters [-7f], [] Maximum 5-character input; scan to terminate this selection. Postamble None -5 characters [-7f], [] Maximum 5-character input; scan to terminate this selection. Serial Interface Message String (RS, USB COM) : STX Preamble Data Length Prefix Symbol ID Scanned Data Suffix Symbol ID Postamble ETX Record Suffix character -5 characters - digits or characters Variable length or characters -5 characters character character 9

Serial Interface Control Delay Setting Family Code Selection P.C Parameter Selection Option Code Intermessage Delay None -99 (x5) msec. Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. Intercharacter Delay Interfunction Delay None -99 (x5) msec. Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. None -99 (x5) msec. Scan digits from the option code chart in Appendix, then DelfiScan will terminate this selection automatically. Intermessage Delay is a time delay between messages output by C7. Increasing this delay will help host applications process the incoming data on time. Intercharacter Delay is a time delay between data characters output by C7. These two parameters are used to synchronize data communication when : ) the data transmission speed is too fast, characters may be skipped; ) multitasking operation system or host computers in a network may slow down the keyboard handling; ) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safty margin when adjusting these two parameters. Interfunction Delay is a time delay between the transmission of each segment of the message string.

Serial Interface Control Protocol, Baud Rate, Data Frame & Time Out Setting Family Code Selection P.C Parameter Selection Option Code Handshaking Protocol None (free running mode) RTS/CTS (hardware handshaking) ACK/NAK (software handshaking) Xon/Xoff (software handshaking) Baud Rate (BPS) 8.4K BPS 9.K BPS 96 BPS 48 BPS 4 BPS BPS 6 BPS BPS 4 5 6 7 Data Frame 8, None, 8, Odd, 8, Even, 8, Space, 8, Mark, 8, None, 7, Odd, 7, Even, 7, Space, 7, Mark, 7, None, 7, Odd, 7, Even, 7, Space, 7, Mark, 4 5 6 7 8 9 A B C D E Time Out Control None mseconds 5 mseconds second seconds 5 seconds User defined value (seconds) 4 5 6, When the RTS/CTS Hardware Handshaking option is selected, the RTS (request to send) and CTS (clear to send) signals will be issued before normal data communication. This option is very helpful to ensure the reliability of data communication. When the ACK/NAK Software Handshaking option is selected, the C7 waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after each data transmission. If the NAK is received, C7 will re-send the data until receiving ACK. The Time Out Control is a pre-defined delay time for C7 to wait for handshaking, acknowledgment or nonacknowledgment from the host computer.

Wand Emulation Control Output Polarity, Signal State, Margin/Module Time, etc. Family Code Selection P.C Parameter Selection Option Code Output Polarity High level (5Vdc) on Bar (low level on Space) Low level (Vdc) on Bar (high level on Space) Determine the output voltage level for both bar and space. Initial Signal State High Level (5Vdc) Low Level (Vdc) Determine the initial state of output voltage level. Margin Time msec. 5 msec. msec. 5 msec. msec. 5 mssec. mseconds Delay time before data transmission 4 5 6 Module Time Extremely short Short Medium Long Time base of minimum narrow bar Narrow/Wide Ratio : :.5 : Code 9 Emulation Disable standard Code 9 emulation Enable standard Code 9 skip emulation Enable standard Code 9 replace emulation [ Code 9 Skip ] : When this option is selected, all scanned data will be translated as Standard Code 9 wand emulation output. If any lower case characters are read, they will be translated to upper case characters. Any other characters that are not available in Code 9 symbology set will be skipped. [ Code 9 Replace] : Any character not normally available in the standard Code 9 symbology set, will be translated as Space.

Operation Control Operation Control Operation Mode Setting Family Code Selection P.C Parameter Selection Option Code Operation Mode Low Power mode (Low Power triggering) Trigger mode/serial mode (External triggering) Presentation mode (Auto detection) Alternative mode (Periodic power off) Flash mode (Pulse driven reading) Force mode (Continued power on) Toggle mode (Repeat reading) Diagnostic mode (Test reading) 4 5 6 7 Lower Power Mode (Low Power Triggering): The scanner goes into idle state after scanning the bar code. You must press the trigger to wake up the scanner for operation. It is very helpful for mobile data collection and application, which are concerned with power savings. Trigger Mode/Serial Mode (External Triggering): The scanner goes into standby state after scanning the bar code. You must press the trigger to turn on the light source of the scanner before scanning the bar code. Presentation Mode (Auto Detection):: Presentation mode uses ambient light to detect bar codes. The LEDs are off for ambient conditions until a change occurs in the imager s field of view. Then the LEDS turn on automatically to read the bar code. If the light level in the room is not high enough, Presentation Mode may not work properly. Alternative Mode (Periodic Power Off): The scanner keeps the light source of the scanner turned on and disables the infrared sensor till the pre-defined auto power off duration is up. After the scanner turns off the light source, you must press the trigger to turn on the light source again. After each good read, the auto power off timer counter is reset. You do not have to press the trigger frequently, it is very convenient for multiple scanning. Flash Mode (Pulse Driven Reading):: The scanner flashes the light source of the scanner without using the trigger. If the scanner detects an image which is similar to a bar code, the scanner forces on the light source automatically and scans the bar code. Pulse Driven Duty Cycle adjustment can change the frequency of the blinking. Force Mode (Continued Power On):: The light source of the scanner is forced on for continued operation without pressing the trigger switch. This mode is convenient for high speed bar code reading. Toggle Mode (Repeat Reading): The toggle mode is very similar to the Alternative Mode without the pre-defined auto power off duration concern. You must press the trigger to turn on the light source of the scanner to scan. The scanner keeps the light source turned on until you press the trigger again. Diagnostic Mode (Test Reading): This operation mode is specifically designed for diagnostic purposes. When this operation mode is selected, the light source of the scanner is force on without regard for other programmable parameters, such as double scan verification, redundancy, and so forth.

Operation Control Buzzer, Indicator, Vibrator, Inverse Reading, Buzzer Tone Adjust Power On Indicator Dollar Sign P.C Parameter Selection Option Code Buzzer tone - mute Buzzer tone - low Buzzer tone - medium Buzzer tone - high Buzzer tone - extremely high 4 Good-read beep before data transmission 5 Good-read beep after data transmission 6 Power-on beep 7 No power-on beep 8 Disable (Power on, LED off) Enable (Power on, LED on as normal) Unavailable for FBC6 series. Vibrator Disable Enable Unavailable for FBC6 series. Inverse Reading Disable Enable Dollar Sign Control Dollar sign output as $ Dollar sign output as Dollar sign output as 4

Operation Control Pulse Driven Duty, Redundancy, Delay Setting Family Code Selection P.C Parameter Selection Option Code Pulse Driven Duty / duty cycle / duty cycle /4 duty cycle 4/5 duty cycle Redundancy (Scan Voting) None time times times 4 times 5 times To prevent potential miss reading. 4 5 Reread Delay Disable Immediate time out Short time out Medium time out Long time out Force verification 4 5 Good Read Delay None msec. 5 msec. sec..5 sec. sec. sec. 4 5 6 The Pulse Driven Duty is designed to control the flashing frequency of the light source. The Redundancy is the number of times the same bar code label has to be decoded before it is transmitted. The Reread Delay is designed to inhibit DelfiScan from reading the same bar code label twice in pre-defined short duration. Force Verification will not allow reading of the same bar code twice. This Good Read Delay is the minimum amount of time before the imager can read another bar code. 5

Operation Control Time-out Setting, Good Read Duration Family Code Selection P.C Parameter Selection Option Code Auto Power Off Duration Short Medium Long Extremely long Hands Free Time-out Short Medium Long Extremely long Good Read Duration Short Medium Long Extremely long The Auto Power Off Duration is a pre-defined power off time out counter for Automatic Mode. You can adjust this parameter to meet your own application requirement. The Force Mode and Presentation Modes are referred to as hands free modes. If the imager s trigger is pulled when using a hands free mode, the imager changes to manual trigger mode. You can set the time for imager to remain in manual trigger mode by setting the Hands Free Time-Out. Once the time-out value is up (if there have been no further trigger pulls), the imager reverts to the original hands free mode. The Good Read Duration is a pre-defined duration of the LED and beep the imager emit on a good read. 6

Condensed DataWizard Preamble, Postamble, Data Length & Symbol ID Trans. M DEFAULT Family Code Selection P.C Parameter Selection Option Code Preamble None -5 characters [-7f], [] Maximum 5-character input; scan to terminate this selection. Postamble None -5 characters [-7f], [] Maximum 5-character input; scan to terminate this selection. Data Length Transmission Disable Enable digits data length transmission If data length exceeds 99, -digit data length will be transmitted. Symbology ID Transmission Disable symbology ID transmission Enable prefix symbology ID transmission Enable suffix symbology ID transmission Enable both prefix and suffix symbology ID transmission DataWizard is the most powerful, Artificial-Intelligence based data editing expert system provided specially for the DelfiScan family bar code readers. Through DataWizard, you can process the scanned data prior the transmissions in many ways as: Insert, Delete, Match, Verify, Replace, Reorganize, and Repeat Transmission. It will help you to arrange the transmission of scanned data to any specific format without software modification. Due to the resources used by this system, Full-feature DataWizard is only supported by PowerTool. Through the PowerTool, all settings and configurations can be done on-screen, under Windows 95/98/NT//XP environment. A Condensed Version DataWizard is provided by each DelfiScan series. Through this menu, the condensed DataWizard can be utilized via bar code menu readings with ease. Please note that all Character input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value. If you have any problem to use DataWizard, please refer to following pages for details and consult your local DelfiScan vendor or our web site for any assistance. 7

Condensed DataWizard Data Formatter Setting Family Code Selection P.C Parameter Selection Option Code nd Option Code Formatter Control Disable Select one bar code symbology Select all bar code symbologies automatic termination automatic termination st Insertion DS Disable Enable -digits identified position; max. insertion characters position [- characters], [] nd Insertion DS Disable Enable -digits identified position; max. insertion characters position [- characters], [] rd Insertion DS Disable Enable -digits identified position; max. insertion characters position [- characters], [] 4 th Insertion DS Disable Enable -digits identified position; max. insertion characters position [- characters], [] The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for formatter control, and provides Multiple Position Insertion and Multiple Character Insertion (max three characters) in the identified position. While the Data Formatter is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbolology ID or Record Suffix. All of the above programmable parameters perform the same function depending on your setting. Regarding the Bar Code Selection and Position Calculation of data formatter, please refer to page 4 for details. Please note that all Character input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value. 8

Condensed DataWizard Data Verifier Setting Family Code Selection P.C Parameter Selection Verifier Control Disable Select one bar code symbology Select all bar code symbologies Option Code nd Option Code automatic termination automatic termination Identified Data Length DS Disable Enable Determine the identified data length for verification. st Indetified Character DS Disable Enable [-7F] -digits checking position; identified character position nd Indetified Character DS Disable Enable -digits checking position; identified character position [-7F] rd Indetified Character DS Disable Enable -digits checking position; identified character position [-7F] The Data Verifier is used to provide advanced verification for error-free scanning and to work as an Embedded Data Transmitting Filter. All data must conform to the Identified Bar Code Symbologies, Identified Data Length, and one to three Identified Characters in the checking position. Otherwise, the DelfiScan will not transmit the data to the host computers or terminals, but will instead issue long beeps for verification error and skip the scanned data. The Data Verifier checks only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix. Regarding the Bar Code Selection and Position Calculation of Data Verifier, please refer to page 4 for details. Please note that all Character input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value. 9

Condensed DataWizard Data Replacer Setting Family Code Selection P.C Parameter Selection Replacer Control Disable Select one bar code symbology Select all bar code symbologies Option Code nd Option Code automatic termination automatic termination st Replacement DS Disable Enable [-7F] -digits identified position; replacement character position nd Replacement DS Disable Enable [-7F] -digits identified position; replacement character position rd Replacement DS Disable Enable [-7F] -digits identified position; replacement character position The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for replacer control, and provides Multiple Position Replcement in the identified position. All data must conform to the Identified Bar Code Symbologies, and one to three Identified Characters in the identified position While the Data Replacer is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix. Regarding the Bar Code Selection and Position Calculation of Data Replacer, please refer to page 7 for details. Please note that all Character input should be referred to the ASCII/HEX Table listed in Appendix to find mathced HEX value. 4

Condensed DataWizard Data Organizer Setting Family Code Selection P.C Parameter Selection Option Code nd Option Code Organizer Control Disable Select one bar code symbology Select all bar code symbologies automatic termination automatic termination st Organization DS Disable Enable -digits identified position; Forward/backward data transmission setting position direction (Forward) (Backward) nd Organization DS Disable Enable -digits identified position; Forward/backward data transmission setting position direction (Forward) (Backward) Include/Exclude Control DS Transmitted data excluded the data of identified position Transmitted data included the data of identified position The Data Organizer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for organizer control, and provides maximum two identified positions to send the data forward or backward. It also allows you to control the transmitted data including or excluding the data of identification position. Please refer to the application example listed in page 7 for details. While the Data Organizer is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix. Reagrding the Bar Code Selection and Position Calculation of Data Organizer, please refer to page 4 for details. Please note that all Character input should be referred to the ASCII/HEX Table. 4

Select a Bar Code Symbology You can select one or all types of bar code symbologies to use Condensed DataWizard for advanced transmission arrangement. If you scan to select all types, the DelfiScan will arrange all incoming data to meet your pre-defined format. If you want to select only one type bar code, please select one of the option code listed below. UPC-E: UPC-A: EAN/CAN/JAN-8: 5 EAN/CAN/JAN-: 4 Code : 7 HIBC: 7 Telepen : Code 8 : UCC/EAN 8 : Code 9 : 7 Code 9 : 9 GS Data Bar : 4 Codabar/NW-7 : 6 Code 5 Family : 8 IATA : 8 Code : UK/Plessey : I/Plessey : Position Calculation [Data Formatter] If there is a 5-character input data string, refer to the following to calculate the actual position for insertion: X X X X X 4 5 Application Example If your bar code label is a 6-digit Interleaved of 5 which includes the information of 6-digit date code, 6- digit serial number and 4-digit unit price, you want the DelfiScan do the following for you without software modification: Apply only Interleaved of 5 to the condensed DataWizard. Check bar code is actually with 6-digit length. Allow bar code output whose date code is leading with 9. Three outputs with TAB suffix. The date code output should skip 9 and replaced it by A. The serial number output should be led with SN. The unit price output should be skipped the first digits. Test Bar Code: 9 8 5 4 5 6 9 8 7 6 Actual Output : A85[TAB]SN456[TAB]76[TAB] [Data Verifier, Data Replacer, Data Organizer] If there is a -character data string, please refer to the following to calculate the actual position for identification. X X X X X X X X X X X 4 5 6 7 8 9 4

Programming Procedure [Data Verifier] Scan Program to enter the programming mode. Scan Verifier Control and set bar code symbology to 8 (Interleaved of 5). Scan Identified Data Length and set the length to 6. Scan st Identified Character and set the identified position to, then set the identified character to 9 (Hex Code of 9). [Data Formatter] Scan Formatter Control and set bar code symbology to 8. Scan st Insertion and set the identified position to 6, then inserted characters to 9 (Hex Code of TAB), 5 (Hex Code of S), 4E (Hex Code of N). Scan nd Insertion and set the identified position to, then inserted character to 9. In the final, you must scan (Finish) code to terminate this selection. Scan rd Insertion and set the identified position to 6, then inserted character to 9. In the final, you must scan (Finish) code to terminate this selection. [Data Replacer] Scan Replacer Control and set bar code symbology to 8. Scan st Replacement and set the identified position to, then replaced character to 4 (Hex Code of A). [Data Organizer] Scan Organizer Control and set bar code symbology to 8. Scan st Organization and set the identified position to 6, then set the data transmission to (forward). Scan nd Organization and set the identified position to 7, then set the data transmission to (backward). Scan END (Exit) to terminate the programming. [Important Notice] Please note that Condensed DataWizard will follow the preset working flow as below: Verifier Formatter Replacer Organizer So when you set the identified position in Data Organizer, you must consider the inserted data which you already set via Data Formatter. 4

Keyboard Function Code Table No. ANSI ASCII Key Function No. ANSI ASCII Key Function NUL H RESERVED 6 DLE H F7 SOH H CTRL (Left) 7 DC H F8 STX H ALT (Left) 8 DC H F9 ETX H SHIFT 9 DC H F 4 EOT 4H CAPS LOCK DC4 4H F 5 ENQ 5H NUM LOCK NAK 5H F 6 ACK 6H ESC SYN 6H INS (Insert) (Edit) 7 BEL 7H F ETB 7H DEL (Delete) (Edit) 8 BS 8H BACK SPACE 4 CAN 8H HOME (Edit) 9 HT 9H TAB 5 EM 9H END (Edit) LF AH F 6 SUB AH PAGE UP (Edit) VT BH F 7 ESC BH PAGE DOWN (Edit) FF CH F4 8 FS CH UP (Edit) CR DH ENTER (CR) 9 GS DH DOWN (Edit) 4 SO EH F5 RS EH LEFT (Edit) 5 SI FH F6 US FH RIGHT (Edit) : High Byte of HEX Value : Low Byte of HEX Value To emulate the keyboard function key input for user definable parameters, user must configure actual content using the Reserved ASCII characters, and also Enable the Function Key Emulation. Otherwise, the Ctrl ouput will be done by the scanner. Please refer to the above Keyboard Function Code Table which is for IBM PC/XT/AT, PS/, PS/VP, COMPAQ PC, HP Vectra PC, Notebook PC, APPLE and PowerMac, and WYSE PC Enhanced or fully compatible machines. 44

ASCII Input Shortcut To configure the user definable parameters of DelfiScan via programming menu, DelfiScan will ask you to scan your desired ASCII value in HEX form. You have to refer to the HEX/ASCII Table for details. Example: If you want the scanned data output leading with a Dollar Sign, you have to set the Preamble to $. The configuration procedure is listed below for reference. Scan the system command listed on page -4 to enter programming mode. Scan family code PREAMBLE to select this family. Refer to the Hex/ASCII Table, you will find the HEX value of $ is 4. Scan the option code listed on the fold out back cover. Scan the option code 4 listed on the fold out back cover. Scan the system command (Finish) to terminate Preamble setting. Scan the system command End to exit the programming mode for normal operation. HEX/ASCII Reference Table H L 4 5 6 7 NUL DLE SPACE @ P ` p SOH DC! A Q a q STX DC " B R b r ETX DC # C S c s 4 EOT DC4 $ 4 D T d t 5 ENQ NAK % 5 E U e u 6 ACK SYN & 6 F V f v 7 BEL ETB ' 7 G W g w 8 BS CAN ( 8 H X h x 9 HT EM ) 9 I Y i y A LF SUB * : J Z j z B VT ESC + ; K [ k { C FF FS, < L \ l D CR GS - = M ] m } E SO RS. > N ^ n ~ F SI US /? O _ o DEL Example : ASCII A HEX 4 ; ASCII a 6 : High Byte of HEX Value : Low Byte of HEX Value 45

Host Interface Quick Set PS/ (DOS/V) Keyboard Wedge RS Serial Interface USB HID Interface Keyboard Replacement USB COM Interface Operation Mode Quick Set Lower Power Mode Force Mode Alternative Mode Trigger Mode Toggle Mode Flash Mode Presentation Mode Diagnostic Mode 46

Option Codes 8 4 C 9 5 D A 6 E B 7 F 47

System Commands (Enter Programming Mode) System Information List (SYSLIST) Save User Default (Finish) Factory Default () User Default END (Exit Programming Mode) PowerTool Host Link 48